Tfs402.doc Version 4.0 VI TELEFILTER Filter Specification 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances in fc: 25 °C 0 dBm for input: for output: 12.02.2002 TFS 402 1/5 50 Ω 0 pF. 50 Ω 0 pF. 2. Characteristics Remark: The reference level for the relative attenuation arel of TFS 402 is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 6 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 402,76 MHz without tolerance. Data typ. value Insertion loss (Reference level) Nominal frequency ae tolerance / limit max 24 fN dB 402,76 MHz Reference frequency fc at ambient temperature (fCTA) 402,76 ± 1 Pass band (-1 dB): MHz fN - 15,25 MHz ... fN + 15,25 MHz Amplitude ripple in pass band (p-p): with sliding interval 1 MHz in pass band (p-p): Relative attenuation - max. 1,0 dB - max. 0,5 dB arel fN MHz fN ± 15,25 MHz - max. 1 dB fN ± 24,5 fN - 401 fN ± 100 fN - 100 MHz - min. 38 dB MHz MHz - min. 25 dB fN + 100 MHz fN + 600 MHz min. 25 dB Group delay 470 µs Deviation from linear phase in pass band (p-p): The part will not show any critical pyroelecric effect for temperature changes of Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature T: max. 4,5 ° 0,5 °C / min - 72 ppm/°C ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz) Operating temperature range - 40 °C ... + 85 °C Storage temperature range - 40 °C ... + 85 °C Generated: Checked / approved : VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs402.doc Version 4.0 VI TELEFILTER Filter Specification 3. Package, pin grid 2,54 mm 5,0Max. 8 9 10 9,3 Max. 6 7 5 1 2 3 4 5 6 7 8 9 10 4 3 4 10 9 5 7 0,8 7,1 Package Ground Package Ground Package Ground Output RF Return Output Package Ground Package Ground Package Ground Input Input RF Return Datecode: M N P ... 2,8 2,54 ± 0,1 1,8 Max. 2 2,54 ± 0,12,54 ± 0,1 0,10 ° 60 1 2 3 8 2/5 (All dimensions in mm) TFS 402 P04 1 TFS 402 12.02.2002 6 Year+week 2000 2001 2002 4. 50 Ω - Matching network: 9 Input 50 Ohm 5 SAW Output 50 Ohm 1, 2, 3, 4, 6, 7, 8, 10 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs402.doc Version 4.0 VI TELEFILTER Filter Specification 12.02.2002 TFS 402 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W : Po Do E F 16 ± 0,3 : 4 ± 0,1 : : 1,5 + 0,1 1,75 ± 0,1 : 3000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Do Po P2 E Ao 7,5 ± 0,1 G (min) : 0,60 P2 : P1 : D1(m in) : 2 8 1,5 Ao : 5,30 Bo : 9,70 ± 0,1 CT : 13,5 ± 0,1 F D1 ± 0,1 ± 0,1 W Bo CT G ± 0,1 P1 COVER TAPE W2 Reel (all dimensions in mm): A : W1 : W2 (max) : 330 16,40 +2,0 22,4 N (min) : 50 C : 13,0 + 0,5/-0.2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs402.doc Version 4.0 VI TELEFILTER Filter Specification TFS 402 12.02.2002 4/5 5. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs402.doc Version 4.0 VI TELEFILTER Filter Specification 12.02.2002 TFS 402 5/5 History Version Reason of Changes 2.0 (former development specification version1.2 changed) Steiner - insertion loss, 23dB24dB - weekly date code introduced - pass band spec and stopband attenuation spec changed to be valid at room temperature only (frequency drift already included in customer limit scheme) 17.04.2000 3.0 new package with Pin 1 marking introduced Steiner 24.01.2002 4.0 definition of performance over temperature redefined Steiner 12.02.2002 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Name Date Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information