TRUMPower 110 WATT MEDICAL POWER ADAPTERS TMP110 SERIES D E SCR IPTION (MDD) The TMP110 series of AC/DC switching power adapters are for 110 watts of continuous output power. They are enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC 320 inlet to mate with interchangeable cord for world-wide use. An on/off switch can be added at request. All models meet CISPR 11 and FCC class B emission limits, and are designed for medical applications. F EATU R E S ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ D u a l , t r i p l e o r q u a d r u p l e o u t p u ts Optional output connectors Optional on/off sw itch Optional Power Fail Detect (PFD) signal 100% burn-in W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C Input surge current protection O v e r v o l ta g e p r o t e c t i o n ‧ Overcurrent protection Saf et y Sta n da rd A ppr o va ls: UL 2601-1 CSA C22.2 No. 601.1 TÜV EN60601-1 IN PUT S PE C IF ICAT ION S E N V IR O N M ENTA L SP E C IF ICATI O N S I n p u t v o l ta g e : 8 5 t o 2 6 4 VA C Input frequency: 47 to 63 Hz Input current: 3 . 2 0 A ( r m s ) f o r 11 5 VA C 1 . 8 0 A ( r m s ) f o r 2 3 0 VA C L e a k a g e c u r r e n t : 9 0 µ A m a x . @ 11 5 VA C , 6 0 H z 1 5 0 µ A m a x . @ 2 3 0 VA C , 5 0 H z Operating temperature: Storage temperature: Relative humidity: Derating: OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Output voltage/current: See rating chart Switching frequency: 20KHz to 250KHz, varies with load and line Total output power: 110 watts maximum Efficiency: Ripple and noise: 1% peak to peak maximum Overvoltage protection: Provided on output #1 only; set at 112-132% of its nominal output voltage Overcurrent protection: All outputs protected to short circuit conditions Temperature coefficient: All outputs ±0.04%/ºC maximum Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500us after a 25% step load change PFD signal (optional): TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1ms prior to +5V output dropping 5% below its nominal value. This signal also provides a minimum delay of 100ms after +5V is within regulation. Hold-up time: Line regulation: 0ºC to +70ºC -40ºC to +85ºC 5% to 95% non-condensing Derate from 100% at +50ºC linearly to 50% at +70ºC 70% minimum on single output models with Vo ≥12V, 65% minimum on the others 12 msec minimum at 110VAC ±0.5% maximum at full load Inrush current: 15 amps @ 115VAC, or 30 amps @230VAC, at 25ºC cold start Withstand voltage: 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF: 550,000 hours minimum at full load at 25ºC ambient, calculated per MIL-HDBK-217F, excluding DC fan. EMC Performance (EN60601-1-2: 2001) E N 5 5 0 11 : Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class A EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8KV air and ±6KV contact EN61000-4-3: Radiated immunity, 3V/m for 80~2500MHz EN61000-4-4: Fast transient/burst, ±2KV EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 3A/m E N 6 1 0 0 0 - 4 - 11 : Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com MEDICAL GRADE TMP110 SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Product No. Output #1 Output #2 (1) Output #3 Vnom. Imin. Imax. Tol. Vnom. Imin. Imax. Ipeak Tol Vnom. Imin. Imax. Tol Output Output #4 Vnom. Imin. Imax. Tol. Power TMP110-D23 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% TMP110-T31 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% TMP110-T32 +5V 0.8A 10A 5% +15V 0A 4A 7.5A 5% -15V 0A 2A 5% TMP110-Q40 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% -5V 0A 2A 5% 110W TMP110-Q41 +5V 0.8A 10A 5% +15V 0A 4A 7.5A 5% -15V 0A 2A 5% +24V 0A 2A 5% 110W TMP110-Q42 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% +12V 0A 2A 5% 110W TMP110-Q45 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% +24V 0A 2A 5% 110W TMP110-Q45-1 +5V 2.0A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% +24V 1.5A 3A 10% 110W TMP110-Q45-2 +5V 0.8A 10A 5% +24V 0A 3A 5.0A 5% -12V 0A 2A 5% +12V 0A 2A 5% 110W TMP110-Q46 +5V 0.8A 10A 5% +15V 0A 4A 7.5A 5% -15V 0A 2A 5% -5V 0A 2A 5% 110W Notes: (N/A) (N/A) 110W (N/A) 110W (N/A) 110W (1) Peak output current with 10% maximum duty cycle for less than 60 seconds. Total peak power must not exceed 130 watts. (2) The output #1 of model TMP110-Q45-1 needs a minimum current of 2A to support the other outputs at their maximum rated loads. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 1.40 Kgs (3.08 Lbs.) approx. 4. Standard output connector is an 8-pin at 270º male DIN plug. For other output connector options, please consult factory. 5. To order a model with on/off switch, add suffix “S” to the product number. e.g. TMP110-T31-S. 6. To order a model with PFD signal, add suffix “PF” to the product number, e.g. TMP110-T31-PF. PIN CHART PIN Product No. TMP110-D23 TMP110-T31 TMP110-Q40 TMP110-Q42 TMP110-Q45-1 TMP110-Q46 TMP110-T32 TMP110-Q41 TMP110-Q45 TMP110-Q45-2 1 2 3 4 5 6 7 8 COMMON RETURN N.C. OUTPUT #1. N.C. OUTPUT #2. COMMON RETURN OUTPUT #1 N.C. or PFD COMMON RETURN OUTPUT #3 OUTPUT #1. N.C OUTPUT #2. COMMON RETURN OUTPUT #1 N.C. or PFD COMMON RETURN OUTPUT #3 OUTPUT #1. OUTPUT #4 OUTPUT #2.. COMMON RETURN OUTPUT #1 N.C. or PFD. Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com