www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 FEATURES D D D D D D D D D D D D DESCRIPTION Wide Input Supply Range: −20 V to −80 V The TPS2392 and TPS2393 integrated circuits are hot swap power managers optimized for use in nominal −48-V systems. They operate with supply voltage ranges from −20-V to −80-V, and are rated to withstand spikes to −100 V. In conjunction with an external N-channel FET and sense resistor, they can be used to enable live insertion of plug-in cards and modules in powered systems. Each device provides load current slew rate control and peak magnitude limiting. Undervoltage and overvoltage shutdown thresholds are easily programmed via a three-resistor divider network. In addition, two active-low, debounced inputs provide plug-in insertion detection. A power good (PG) output enables downstream converters. The TPS2392 and TPS2393 also provide the basic hot swap functions of electrical isolation of faulty cards, filtered protection against nuisance overcurrent trips, and single-line fault reporting. The 44-pin part supports designs where telecomm creepage and clearance requirements must be followed. Transient Rating to −100 V Programmable Current Limit Programmable Current Slew Rate Programmable UV/OV Thresholds/Hysteresis Debounced Insertion Detection Inputs Open-Drain Power Good (PG) Output Fault Timer to Eliminate Nuisance Trips Open-Drain Fault Output (FAULT) Enable Input (EN) 14-Pin TSSOP package 44-Pin TSSOP Package for Creapage/Clearance APPLICATIONS D −48-V Distributed Power Systems D Central Office Switching D Wireless Base Station R1 200 kΩ 1% GND The TPS2392 latches off in response to current faults, while the TPS2393 periodically retries the load in the event of a fault. DC/DC CONVERTER R2 4.99 kΩ 1% VIN+ C4 100 µF 100 V R6 10 kΩ R3 3.92 kΩ 1% TPS2392/TPS2393 R5 100 kΩ D2 5.6 V C3 1500 pF −48V C2 0.1 µF C1 3900 pF UVLO OVLO 14 2 INSA DRAINSNS 13 3 INSB 4 FAULT 5 EN GATE 10 6 FLTTIME ISENS 7 IRAMP VOUT+ COUT EN VIN− 1 VOUT+ VDD VOUT− VOUT− D1 BAS19 PG 12 RTN 11 Q1 IRF530 VUV = 32.8 V VUV = 30.8 V VOV = 72.6 V 9 −VIN 8 R4 20 mΩ 1/4, 1% UDG−02098 . Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. !"# $ %&'# "$ (&)*%"# +"#', +&%#$ %! # $('%%"#$ (' #-' #'!$ '."$ $#&!'#$ $#"+"+ /""#0, +&%# (%'$$1 +'$ # '%'$$"*0 %*&+' #'$#1 "** (""!'#'$, Copyright 2004, Texas Instruments Incorporated www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. ORDERING INFORMATION TA FAULT OPERATION LATCH OFF PERIODIC RETRY −40°C to 85°C LATCH OFF PERIODIC RETRY PACKAGE TSSOP (PW)(1) TSSOP (PW)(1) PART NUMBER TSSOP (PW)(1) TSSOP (PW)(1) TPS2392DBT TPS2392PW TPS2393PW TPS2393DBT (1) The PW and DBT package is also available taped and reeled. Add an R suffix to the device type (i.e., TPS2392PWR) for quantities of 2,500 per reel. ABSOLUTE MAXIMUM RATINGS over operating free-air temperature range unless otherwise noted(1) TPS2392 TPS2393 Input voltage range, VI UVLO, INSA, INSB, FLTTIME, IRAMP, OVLO, DRAINSNS, GATE, ISENS(2) RTN(2) EN(2)(3) FAULT(2)(4) Output voltage range, VO UNIT −0.3 to 15 V −0.3 to 100 PG(2)(4) FAULT Continuous output current PG 10 Operating junction temperature range, TJ −55 to 125 Storage temperature, Tstg −65 to 150 mA °C C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260 (1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. (2) All voltages are with respect to −VIN (unless otherwise noted). (3) With 100-kΩ minimum input series resistance. (4) With 10-kΩ minimum series resistance. 2 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 RECOMMENDED OPERATING CONDITIONS MIN NOM MAX UNIT Input supply voltage, −VIN to RTN −80 −20 V Operating junction temperature, TJ −40 85 °C DISSIPATION RATINGS PACKAGE TA < 25°C POWER RATING DERATING FACTOR ABOVE TA = 25°C TA = 85°C POWER RATING TSSOP−14 750 mW 7.5 mW/°C 300 mW DBT PACKAGE (TOP VIEW) PW PACKAGE (TOP VIEW) UVLO INSA INSB FAULT EN FLTTIME IRAMP 1 2 3 4 5 6 7 14 13 12 11 10 9 8 OVLO DRAINSNS PG RTN GATE ISENS −VIN INSA N/C N/C N/C N/C N/C INSB N/C N/C N/C N/C N/C FAULT(BAR) EN FLTTIME IRAMP N/C N/C N/C N/C N/C −VIN 1 44 2 43 3 42 4 41 5 40 6 39 7 38 8 37 9 36 10 35 11 34 12 33 13 32 14 31 15 30 16 29 17 28 18 27 19 26 20 25 21 24 22 23 UVLO OVLO N/C DRAIN SENSE PG(BAR) N/C N/C N/C N/C N/C RTN N/C N/C N/C N/C N/C GATE ISENS N/C N/C N/C N/C 3 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 ELECTRICAL CHARACTERISTICS VI(−VIN) = −48 V with respect to RTN, VI(EN) = 2.8 V, VI(INSA) = 0 V, VI(INSB) = 0 V, VI(UVLO) = 2.5 V, VI(OVLO) = 0 V, VI(ISENS) = 0 V, all outputs unloaded, TA = −40°C to 85°C (unless otherwise noted)(1)(2) PARAMETER TEST CONDITIONS MIN TYP MAX 1050 1500 1350 1700 −16 −13 UNIT INPUT SUPPLY ICC1 ICC2 Supply current, RTN VUVLO_L Internal UVLO threshold, VIN rising VHYS Internal UVLO hysteresis VI(RTN) = 48 V VI(RTN) = 80 V To GATE pull-up −19 200 µA A V mV ENABLE INPUT (EN) VTH Threshold voltage, VIN rising ISRC_EN EN pin switched pull-up current To GATE pull-up 1.3 1.4 1.5 V −12 −10 −8 µA To GATE pull-up 1.36 1.40 1.44 V VI(UVLO) = 2.5 V VI(UVLO) = 1 V −11.7 −10.0 −8.3 µA UVLO low-level input current 1 µA Threshold voltage, VIN rising, OVLO To GATE pull-up 1.36 1.40 1.44 V −11.7 −10.0 −8.3 µA 1 µA UNDERVOLTAGE/OVERVOLTAGE COMPARATORS VTH_UV Threshold voltage, VIN rising, UVLO ISRC_UV UVLO pin switched pull-up current IIL VTH_OV ISRC_OV OLVO pin switched pull-up current IIL OVLO low-level input current VI(OVLO) = 2.5 V VI(OVLO) = 1 V −1 −1 INSERTION DETECTION VTH ISRC_INSx Threshold voltage, VIN rising, INSA, INSB To GATE pull-down 1.0 1.4 1.8 V INSA, INSB pin pull-up current VI(INSA) = 0 V, VI(INSB) = 0 V To GATE pull-up −14 −11 −8 µA 1.5 2.5 4.1 ms 11 14 17 V 5 10 tD_INS Insertion delay time, VIN falling, INSA, INSB LINEAR CURRENT AMPLIFIER (LCA) VI(ISENS) = 0 V, IO(GATE) = −10 µA VI(ISENS) = 80 mV, VO(GATE) = 5 V VO(FLTTIME) = 2 V VI(ISENS) = 80 mV, VO(GATE) = 5 V VO(FLTTIME) > 4 V VOH High-level output voltage, GATE ISINK Output sink current, linear mode IFAULT Output sink current, fault shutdown II VREF_K Input current, ISENS 0 V < VI(ISENS) < 0.2 V −1 Reference clamp voltage VO(IRAMP) = OPEN VO(IRAMP) = 2 V 33 VO(IRAMP) = 0.25 V VO(IRAMP) = 1 V −850 −600 −400 −11 −10 −9 −11 −10 −9 VIO Input offset voltage RAMP GENERATOR ISRC1 IRAMP source current, reduced rate turn-on ISRC2 IRAMP source current, normal rate VOL AV Low-level output voltage, IRAMP VO(IRAMP) = 3 V VI(EN) = 0 V Voltage gain, relative to ISENS mA 50 100 1 40 −7 µA 47 7 2 mV nA µA A mV 9.5 10.0 10.5 mV/V 80 100 120 mV 2 4 7 µs OVERLOAD COMPARATOR VTH_OL tDLY (1) (2) 4 Current overload threshold, ISENS Glitch filter delay time VI(ISENS) = 200 mV All voltages are with respect to the −VIN terminal, unless otherwise stated. Currents are positive into and negative out of the specified terminals. www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 ELECTRICAL CHARACTERISTICS (continued) VI(−VIN) = −48 V with respect to RTN, VI(EN) = 2.8 V, VI(INSA) = 0 V, VI(INSB) = 0 V, VI(UVLO) = 2.5 V, VI(OVLO) = 0 V, VI(ISENS) = 0 V, all outputs unloaded, TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VOL ICHG Low-level output voltage, FLTTIME VI(EN) = 0 V VI(ISENS) = 80 mV, VO(FLTTIME) = 2 V 5 mV −55 −50 −45 µA VFLT IDSG Fault threshold voltage 3.75 4.00 4.25 V Discharge current, retry mode TPS2393 0.38 0.61 µA D Output duty cycle TPS2393 1.0% 1.5% FAULT TIMER Charging current, current limit mode IRST Discharge current, timer reset mode POWERGOOD SENSING VTH ISRC DRAINSNS threshold voltage IOH High-level output leakage current, PG output DRAINSNS pull-up current RDS(on) Driver on-resistance, PG output VI(ISENS) = 80 mV, VO(FLTTIME) = 2 V VI(ISENS) = 80 mV VO(FLTTIME) = 2 V, VI(ISENS) = 0 V VI(DRAINSNS) = 0 V VI(EN) = 0 V, VO(PG) = 65 V 1 mA 1.20 1.35 1.50 −14 −11 −8 VI(ISENS) = 0 V, VI(DRAINSNS) = 0 V IO(PG) = 1 mA 10 50 V µA A 80 Ω 10 µA 80 Ω FAULT OUTPUT IOH High-level output leakage current, FAULT RDS(on) Driver on-resistance, FAULT (1) (2) VI(EN) = 0 V, VO(FAULT) = 65 V VI(ISENS) = 80 V, VO(FLTTIME) = 5 V IO(FAULT) = 1 mA 50 All voltages are with respect to the −VIN terminal, unless otherwise stated. Currents are positive into and negative out of the specified terminals. TERMINAL FUNCTIONS TERMINAL I/O DESCRIPTION NAME PW DBT DRAINSNS 13 41 I Sense input for monitoring the load voltage status EN 5 14 I Enable input to turn on/off power to the load FAULT 4 13 O Open-drain, active-low indication of a load fault condition FLTTIME 6 15 I/O Connection for user-programming of the fault timeout period GATE 10 28 O Gate drive for external N−channel FET INSA 2 1 I Insertion detection input pin A INSB 3 7 I Insertion detection input pin B IRAMP 7 16 I/O ISENS 9 27 I Current sense input OVLO 14 43 I Voltage sense input for supply overvoltage lockout (OVLO) protection PG 12 40 O Open-drain, active-low indication of load power-good condition RTN 11 34 I Positive supply input UVLO 1 44 I Voltage sense input for supply undervoltage lockout (UVLO) protection −VIN 8 22 I Negative supply input and reference pin Programming input for setting the inrush current slew rate 5 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 PIN ASSIGNMENTS DRAINSNS: Sense input for monitoring the load voltage status. The DRAINSNS pin determines the load status by sensing the voltage level on the external pass FET drain. DRAINSNS must be pulled low with repect to −VIN (less than 1.35 V typically) to declare a power good condition. This corresponds to a low VDS across the FET, indicating that the load voltage has successfully ramped up to the DC input level. DRAINSNS must be connected to the FET drain through a small-signal blocking diode as shown in the typical application diagram. An internal pull-up maintains a high logic level at the pin until overridden by a fully-enhanced external FET. EN: Enable input to turn on/off power to the load. The EN pin is referenced to the −VIN potential of the circuit. When this input is pulled high (above the nominal 1.4-V threshold), and all other input qualifications are met (supply above device undervoltage lockout (UVLO), UVLO pin high and OVLO pin low, INSx pins pulled low) the device enables the GATE output, and begins the ramp of current to the load. When this input is low, the linear current amplifier (LCA) is disabled, and a large pull-down device is applied to the FET gate, disabling power to the load. FAULT: Open-drain, active-low indication of a load fault condition. When the device EN is deasserted, or when enabled and the load current is less than the programmed limit, this output is high impedance. If the device remains in current regulation mode at the expiration of the fault timer, or if a fast-acting overload condition causes greater than 100-mV drop across the sense resistor, the fault is latched, the load is turned off, and the FAULT pin is pulled low (to −VIN). The TPS2392 remains latched off for a fault, and can be reset by cycling either the EN pin or power to the device. The TPS2393 retries the load at approximately a 1% duty cycle. FLTTIME: Connection for user-programming of the fault timeout period. An external capacitor connected from FLTTIME to −VIN establishes the timeout period to declare a fault condtion. This timeout protects against indefinite current sourcing into a faulted load, and also provides a filter against nuisance trips from momentary current spikes or surges. The TPS2392 and TPS2393 define a fault condition as voltage at the ISENS pin at or greater than the 40-mV fault threshold. When a fault condition exists, the timer is active. The devices manage fault timing by charging the external capacitor to the 4-V fault threshold, then subsequently discharging it to reset the timer (TPS2392), or discharging it at approximately 1% the charge rate to establish the duty cycle for retrying the load (TPS2393). Whenever the internal fault latch is set (timer expired), the pass FET is rapidly turned off, and the FAULT output is asserted. GATE: Gate drive for external N−channel FET. When enabled, and the input supply is above the UVLO threshold, the gate drive is enabled and the device begins charging an external capacitor connected to the IRAMP pin. This pin voltage is used to develop the reference voltage at the non-inverting input of the internal LCA. The inverting input is connected to the current sense node, ISENS. The LCA acts to slew the pass FET gate to force the ISENS voltage to track the reference. The reference is internally clamped at 40 mV, so the maximum current that can be sourced to the load is determined by the sense resistor value as IMAX ≤ 40 mV/RSENSE. Once the load voltage has ramped up to the input dc potential, and current demand drops off, the LCA drives the GATE output to about 14 V to fully enhance the pass FET, completing the low-impedance supply return path for the load. INSA: Insertion detection input pin A. The INSA and INSB inputs work together to provide an insertion detection function for TPS2392 and TPS2393 applications. In order to turn on the FET gate drive (the GATE output), both INSA and INSB must be pulled below the detection threshold, approximatey 1.4 V. Implementations using this feature provide a mechanism for pulling these pins directly to −VIN potential (device ground), eliminating any threshold ambiguity. An on-chip pull-up is provided at each INSx pin; no additional pull-up is needed to hold the pins high during the insertion process. The insertion inputs are debounced with a nominal 2.5-ms filter. INSB: Insertion detection input pin B. See INSA description. IRAMP: Programming input for setting the inrush current slew rate. An external capacitor connected between this pin and −VIN establishes the load current slew rate whenever power to the load is enabled. The device charges the external capacitor to establish the reference input to the LCA. The closed-loop control of the LCA and pass FET acts to maintain the current sense voltage at ISENS at the reference potential. Since the sense voltage is developed as the drop across a resistor, the load current slew rate is set by the voltage ramp rate at the IRAMP pin. When the output is disabled for any reason (e.g., EN deassertion, voltage or current fault, etc.), the capacitor is discharged and held low to initialize it for the next turn-on. 6 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 PIN ASSIGNMENTS ISENS: Current sense input. An external low-value resistor connected between this pin and −VIN is used to feed back current magnitude information to the TPS2392 and TPS2393. There are two internal device thresholds associated with the voltage at the ISENS pin. During ramp-up of the load’s input capacitance, or during other periods of excessive demand, the HSPM acts to limit this voltage to 40 mV. Whenever the LCA is in current regulation mode, the capacitor at FLTTIME is charged to activate the timer. If, when the LCA is driving to its supply rail, a fast-acting fault such as a short-circuit, causes the ISENS voltage to exceed 100 mV (the overload threshold), the GATE pin is pulled low rapidly, bypassing the fault timer. OVLO: Voltage sense input for supply overvoltage lockout (OVLO) protection. Overvoltage protection can be achieved by applying a divided down sample of the input supply voltage to this pin. In order to turn on gate drive to the external FET, the OVLO pin must be below the 1.4-V typical threshold, while all other input qualifications are met. If the OVLO pin is raised above this threshold, as with increasing supply voltage, the GATE output is pulled low, interrupting the supply to the load. An internal 10-µA pull-up is switched to this pin when the threshold is exceeded, providing a mechanism for setting the amount of OVLO hysteresis along with the trip threshold. PG: Open-drain, active-low indication of load power good condition. The TPS2392 and TPS2393 devices define power good as the voltage at the DRAINSNS pin below the power good threshold, and the voltage at the IRAMP pin being above 5 V. This assures that full programmed sourcing current is available to the load prior to declaring power good, even with very slow current ramp rates. The additional protection prevents potential discharging of the module bulk capacitance during load turn-on. RTN: Positive supply input for the TPS2392 and TPS2393. For negative voltage systems, the supply pin connects directly to the return node of the input power bus. Internal regulators step down the input voltage to generate the various supply levels used by the TPS2392 and TPS2393. UVLO: Voltage sense input for supply uvervoltage lockout (UVLO) protection. Undervoltage protection can be achieved by applying a divided down sample of the input supply voltage to this pin. In order to turn on the gate drive to the external FET, the UVLO pin must be above the 1.4-V typical threshold, while all other input qualifications are met. If the UVLO pin drops below this threshold, as with decreasing supply voltage, the GATE output is pulled low, interrupting the supply to the load. An internal 10-µA pull−up is switched to this pin when the threshold is exceeded, providing a mechanism for setting the amount of UVLO hysteresis along with the trip threshold. For proper operation, a minimum 1500-pF capacitor, connected between the UVLO and −VIN pins, is required. −VIN: Negative supply input and reference pin for the TPS2392 and TPS2393. This pin connects directly to the input supply negative rail. The input and output pins and all internal circuitry are referenced to this pin, so it is essentially the GND or VSS pin of the device. 7 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 TYPICAL CHARACTERISTICS EN (5 V/div) EN (5 V/div) VDRAIN (20 V/div) VDRAIN (50 V/div) CONTACT BOUNCE CONTACT BOUNCE CIRAMP = 3900 pF CFLT = 0.1 µF CLOAD = 50 µF ILOAD (500 mA/div) CLOAD = 100 µF t − Time − 2.5 ms / div t − Time − 1 ms / div Figure 1. Live Insertion Event − VIN = −48 V Figure 2. Live Insertion Event − VIN = −70 V TPS2392 ONLY TPS2393 ONLY VDRAIN (50 V/div) VDRAIN (50 V/div) FLTTIME (2 V/div) FLTTIME (2 V/div) ILOAD (1 A/div) ILOAD (1 A/div) FAULT (20 V/div) FAULT (20 V/div) CIRAMP = 3900 pF CFLT = 0.047 µF CIRAMP = 3900 pF CFLT = 0.047 µF t − Time − 1 ms / div Figure 3. Turn−On Into Shorted Load 8 ILOAD (500 mA/div) t − Time − 1 ms / div Figure 4. Turn−On Into Shorted Load (TPS2393) www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 TYPICAL CHARACTERISTICS CLOAD = 50 µF VUVLO_L VUVLO_H RTN (5 V/div) RTN (5 V/div) GATE (5 V/div) GATE (5 V/div) CLOAD = 50µF RLOAD = 1 kΩ t − Time − 5 ms / div t − Time − 5 ms / div Figure 5. UVLO Protection, Supply Rising Figure 6. UVLO Protection Supply Falling IRAMP (2 V/div) INSA (5 V/div) CIRAMP= 3900 pF Insertion Delay GATE (5 V/div) CIRAMP = .022 µF CIRAMP = .056 µF CFLT = 0.33 µF CLOAD = 600 µF VDRAIN (20 V/div) ILOAD (500 mA/div) t − Time − 1 ms / div Figure 7. Inertion Detection Function t − Time − 10 ms / div Figure 8. Load Current Ramp Profiles 9 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 TYPICAL CHARACTERISTICS FAULT (50 V/div) FAULT (50 V/div) CIRAMP = 3900 pF CFLT = 0.047 µF CLOAD = 100 µF RLOAD = 12.5 Ω PG (50 V/div) CIRAMP = 3900 pF CFLT = 0.047 µF CLOAD = 100 µF PG (50 V/div) FLTTIME (2 V/div) FLTTIME (2 V/div) VDRAIN (50 V/div) VDRAIN (50 V/div) ILOAD (1 A/div) ILOAD (1 A/div) t − Time − 50 ms / div t − Time − 50 ms / div Figure 9. Fault Retry Operation (TPS2393) Figure 10. Fault Recovery (Large Scale View) TPS2393 ONLY CIRAMP = 3900 pF CLOAD = 220 µF FAULT (50 V/div) CIRAMP = 3900 pF CFLT = 0.047 µF CLOAD = 100 µF PG (50 V/div) IRAMP (2 V/div) FLTTIME (2 V/div) VDRAIN (20 V/div) VDRAIN (50 V/div) PG (50 V/div) ILOAD (1 A/div) 10 t − Time − 1 ms / div t − Time − 1 ms / div Figure 11. Fault Recovery − Expanded View Figure 12. PG Output Timing, Voltage Qualified www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 TYPICAL CHARACTERISTICS SUPPLY CURRENT vs AMBIENT TEMPERATURE 1500 CIRAMP = 6800 pF CLOAD = 50 µF VTH_PG VRTN = 80 V ICC − Supply Current − µA 1200 IRAMP (2 V/div) VDRAIN (20 V/div) 900 VRTN = 48 V 600 VRTN = 36 V VRTN = 20 V 300 PG (50 V/div) 0 −40 t − Time − 1 ms / div −15 10 35 60 TA − Ambient Temperature − °C Figure 13. PG Output Timing, Current Qualified IRAMP OUTPUT CURRENT vs AMBIENT TEMPERATURE, REDUCED RATE GATE HIGH-LEVEL OUTPUT VOLTAGE vs AMBIENT TEMPERATURE VI(ISENS) = 0 V IO(GATE) = −10 µA 15 VOH − Output Voltage − V Figure 14. −500 VRTN = 80 V VRTN = 48 V ISRC1 − IRAMP Output Current − nA 16 14 13 VRTN = 36 V 12 VRTN = 20 V 11 10 −40 −15 10 35 60 TA − Ambient Temperature − °C Figure 15. 85 85 VO(IRAMP) = 0.25 V −520 VRTN = 48 V VRTN = 20 V −540 −560 VRTN = 80 V −580 −600 −620 −40 −15 10 35 60 85 TA − Ambient Temperature − °C Figure 16. 11 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 TYPICAL CHARACTERISTICS IRAMP OUTPUT CURRENT vs AMBIENT TEMPERATURE, NORMAL RATE −47 −9.0 VI(ISENS) = 80 mV VO(FLTTIME) =2V Average for VO(IRAMP) = 1 V, 3 V VRTN = 20 V to 80 V −48 ICHG − Charging Current − µA ISRC2 − IRAMP Output Current − µA TIMER CHARGING CURRENT vs AMBIENT TEMPERATURE −9.4 −9.8 −10.2 VRTN = 20 V −49 −50 −51 VRTN = 36 V −10.6 VRTN = 48 V VRTN = 80 V −52 −11.0 −40 −15 10 35 60 TA − Ambient Temperature − °C −53 −40 85 −15 TIMER DISCHARGE CURRENT vs AMBIENT TEMPERATURE 360 320 280 240 −40 −15 10 35 60 TA − Ambient Temperature − °C Figure 19. 12 60 85 FAULT LATCH THRESHOLD vs AMBIENT TEMPERATURE 4.25 TPS2393 ONLY VI(ISENS) = 80 mV VO(FLTTIME) = 2 V VI(RTN) = 20 V to 80 V VFLT − Fault Latch Threshold Voltage − V IDSG − Charging Current − nA 400 35 Figure 18. Figure 17. 440 10 TA − Ambient Temperature − °C 85 VI(RTN) = 48 V 4.15 4.05 3.95 3.85 3.75 −40 −15 10 35 60 TA − Ambient Temperature − °C Figure 20. 85 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 TYPICAL CHARACTERISTICS UVLO PIN PULL-UP CURRENT vs AMBIENT TEMPERATURE VOLTAGE COMPARATOR THRESHOLD vs AMBIENT TEMPERATURE −9.3 ISRC_UV − Charging Current − µA VTH − Voltage Comparator Threshold − V 1.44 VI(RTN) = 20 V to 48 V Undervoltage Comparator 1.42 1.40 Overvoltage Comparator VI(RTN) = 80 V 1.38 VI(UVLO) = 2.5 V VI(RTN) = 20 V to 48 V −9.5 −9.7 −9.9 −10.1 1.36 −40 −15 10 35 60 TA − Ambient Temperature − °C 85 −10.3 −40 −15 10 35 60 TA − Ambient Temperature − °C 85 Figure 22. Figure 21. INSA PIN INSERTION DELAY TIME vs AMBIENT TEMPERATURE tD_INS − INSA Insertion Delay − ms 3.0 2.9 VRTN = 20 V VRTN = 80 V 2.8 2.7 2.6 VRTN = 36 V VRTN = 48 V 2.5 Input voltage falling measured to GATE pull-up 2.4 −40 −15 10 35 60 TA − Ambient Temperature − °C 85 Figure 23. 13 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 DETAILED DESCRIPTION When a plug-in module or printed circuit card is inserted into a live chassis slot, discharged supply bulk capacitance on the board can draw huge transient currents from the system supplies. Without some form of inrush limiting, these currents can reach peak magnitudes ranging over 100 A, particularly in high-voltage systems. Such large transients can damage connector pins, PCB etch, and plug-in and supply components. In addition, current spikes can cause voltage droops on the power distribution bus, causing other boards in the system to reset. The TPS2392 and TPS2393 are hot swap power managers that limit current peaks to preset levels, as well as control the slew rate (di/dt) at which charging current ramps to the programmed limit. These devices use an external N-channel pass FET and sense element to provide closed-loop control of current sourced to the load. Input undervoltage lockout (UVLO) and overvoltage lockout (OVLO) functions control automatic turn-on when the input supply voltage is within the specified operational window, otherwise inhibiting card operation by turning off the pass FET. In addition, load power can be controlled with a system logic command via the EN input, allowing electrical isolation of faulty cards from the power bus. Two active-low inputs can be connected to provide card insertion detection. An internal overload comparator provides circuit breaker protection against short-circuits occurring during steady-state (post-turn-on) operation of the card. Load power status is continuously monitored and reported via the PG (powergood) and FAULT outputs. The TPS2392 and TPS2393 operate directly from the input supply (nominal −48 Vdc rail). The −VIN pin connects to the negative voltage rail, and the RTN pin connects to the supply return. Internal regulators convert input power to the supply levels required by the device circuitry. An input UVLO circuit holds the GATE output low until the supply voltage reaches a nominal 16-V level, regardless of the status of all other control inputs. A block of comparators monitors input supply voltage and other output enable conditions. As shown in Figure 24, the status of these five comparators is AND’d together in order to enable turning on power to the load. Two precision comparators monitor the voltage levels at the UVLO and OVLO pins. Typically, these pins are driven with a divided-down sample of the supply voltage to establish the UVLO and OVLO trip thresholds for the circuit. The UVLO input must be above the internal 1.4-V reference, and the OVLO pin must remain below the reference voltage to enable the load. Both of these inputs are provided with a small, 10-µA pull-up source, which is switched to the input pin whenever the associated comparator is tripped. These current sources provide a mechanism for user-programming of the amount of hysteresis for the UVLO and OVLO thresholds. The same comparator circuit is also available at the EN pin, providing a third precision input. A switched pull-up is also available at this pin for hysteresis programming. Alternatively, this input can be used as a logic enable command, with a nominal 1.4-V logic threshold. The INSA and INSB pins provide an optional insertion detection function to the hot swap circuit. Both these pins must be pulled low, below 1.0 -V minimum, to enable a load start-up. Internal pull-ups at these inputs maintain a HI logic level (about 6.5 V) at the device pins when floating. This eliminates the need for additional external components to maintain the HI logic level during insertion and extraction events. An external mechanism for pulling these inputs low completes the qualification for turning on power to the load. Once the device is enabled (internal EN_A signal asserted), the GATE output pull-down is turned off, and the linear control amplifier (LCA) is enabled. A current source in the ramp generator block begins charging an external capacitor connected between the IRAMP and −VIN pins. The resultant voltage ramp at the IRAMP pin is scaled by a factor of 1/100, and applied to the non-inverting input of the LCA (the VLIM signal). Load current magnitude information at the ISENS pin is applied to the inverting input. This sense voltage is developed by connecting the current sense resistor between ISENS and −VIN. As the external FET begins to conduct, the LCA slews its gate to force the ISENS voltage to track the internal reference (VLIM). Consequently, the load current slew rate tracks the linear voltage ramp at the IRAMP pin, producing a linear di/dt of current to the load. 14 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 DETAILED DESCRIPTION RTN 11 10 µA 10 µA 1.35V 13 DRAINSNS 12 PG + + INSA 2 + 10 µA Q R Q 5V + INSB S FLT 3 10 µA EN_A H=CLOSED UVLO 1 7 IRAMP 4 FAULT 6 FLTTIME 9 ISENS 10 GATE RAMP GENERATOR + VLIM FLT ON 10 µA L=CLOSED EN OVLO 14 FAULT TIMER + OC 10 µA 5 Q R R Q FT OVERCURRENT 100 mV OLC + + VLIM 1.4V −VIN S OVERLOAD H=CLOSED EN OL S LCA + EN_A 8 UDG−02116 Figure 24. Block Diagram of PW Package Under normal load and input supply conditions, this controlled current charges the module’s input bulk capacitance up to the input dc voltage level. At this point, the load demand drops off, and the voltage at ISENS decreases. The LCA now drives the GATE output to its supply rail. The 14-V typical output level ensures sufficient overdrive to fully enhance the external FET, while not exceeding the typical 20-V VGS rating of common N-channel power MOSFETs. 15 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 RTN 34 10 µA 10 µA 1.35V 41 DRAINSNS 40 PG + + INSA 1 + 10 µA Q R Q 5V + INSB S FLT 7 10 µA EN_A H=CLOSED UVLO 44 16 IRAMP RAMP GENERATOR + VLIM FLT 13 ON 10 µA L=CLOSED EN OVLO 43 FAULT TIMER + OC OL S S Q R R Q FAULT FT 15 FLTTIME 10 µA OVERLOAD OVERCURRENT H=CLOSED EN 14 27 ISENS + VLIM 1.4V −VIN 100 mV OLC + LCA + 28 GATE EN_A 22 UDG−02116 Figure 25. Block Diagram of DBT Package 16 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 DETAILED DESCRIPTION Current fault response timing and retry duty cycle are accomplished by the fault timer block in conjunction with an external capacitor connected between the FLTTIME and −VIN pins. Whenever the hot swap controller is in current control mode, such as during inrush limiting at insertion, or in response to excessive demand during operation of the plug-in, the LCA asserts the OVERCURRENT signal shown in Figure 24. This signal starts the charging of the FLTTIME capacitor. If this capacitor charges to the pin’s 4-V trip threshold, the fault is latched. A latched fault disables the LCA drive, and turns on a large pull-down device at the GATE output to rapidly turn off the external FET. The fault condition is indicated by turning on the open-drain FAULT output driver. A latched fault also causes discharge of the external capacitors at the IRAMP and FLTTIME pins, in order to reset the hot swap circuit for the next output enable event, if and when conditions permit. An internal overload comparator (OLC in Figure 24) also monitors the ISENS voltage against a nominal 100-mV threshold. This comparator provides circuit breaker protection against sudden current fault conditions, such as a load short-circuit. The OVERLOAD output of this comparator also drives the fault timer. The timer circuit applies a 4-µs deglitch filter to help reduce nuisance trips. However, if the overload condition exceeds the filter length, the fault is latched, the LCA disabled, and the FET gate rapidly pulled down, bypassing the programmed timeout period. The PG pin is an open-drain, active-low indication of a load power good status. Load voltage sensing is provided at the DRAINSNS pin. To assert PG, the device must not be in latched current fault status, the DRAINSNS pin must be pulled below the 1.35-V nominal threshold, and the voltage at the IRAMP pin must be greater than approximately 5 V. This last criteria ensures that maximum allowed sourcing current is available to the load before declaring power good. Once all the conditions are met, the PG status is latched on-chip. This prevents instances of momentary current-limit operation (e.g., due to load surges or voltage spikes on the input supply) from propagating through to the PG output. However, if input conditions are not met, or if a persistent load fault does result in fault timeout, the PG latch will be cleared. Additional details of the ramp generator operation are shown in Figure 25. To enable the generator, the large NMOS device shown in this circuit is turned off. This allows a small current source to charge the external capacitor connected at the IRAMP pin. The voltage ramp on the capacitor actually has two discrete, linear slopes. As shown in Figure 25, current is supplied from either of two sources. An internal comparator monitors the IRAMP voltage level, and selects the appropriate charging rate. Initially at turn-on, when the pin voltage is 0 V, the 600-nA source is selected, to provide a slow turn-on (or reduced-rate) sourcing period. This slow turn-on ensures that the LCA is pulled out of saturation, and is slewing to the voltage at its non-inverting input before normal rate load charging is allowed. This scheme helps reduce or eliminate current steps at the external FET on-threshold. Once the voltage at the IRAMP pin reaches approximately 0.5 V, the SLOW signal is deasserted, and the 10-µA source is selected for the remainder of the ramp period. The IRAMP pin voltage is divided down by a factor of 100, and applied to the non-inverting input of the LCA (see Figure 24). Although the IRAMP capacitor is charged to about 6.5 V, the VLIM reference is clamped at 40 mV. Therefore, current sourced to the load during turn-on is limited to a value given by IMAX ≤ 40 mV/RSENSE, where RSENSE is the value of the external sense resistor. Therefore, both load current maximum slew rate and peak magnitude are easily set with just two external components. 17 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 DETAILED DESCRIPTION 10 µA 600 nA SLOW + 0.5 V IRAMP VLIM 99R EN_A R 40mV UDG−20117 Figure 26. Ramp Generator Block Details Note that any condition which causes turn-off of the external FET (EN_A signal goes low) also causes a rapid discharge of the IRAMP capacitor. In this manner, the soft-start function is automatically reset by the TPS2392 and TPS2393, and ready for the next load enable event. Fault timer operation is further detailed in Figure 26. As described earlier, the LCA OVERCURRENT output drives the OC input signal shown in Figure 26. Overcurrent fault timing is actually inhibited during the reduced rate (slow turn-on) portion of the IRAMP voltage waveform. However, once the device transitions to the normal rate current ramp (VO(IRAMP) ≥ 0.5 V), the FLTTIME capacitor is charge by the 50-µA current source, generating a second voltage ramp at the FLTTIME pin. This voltage is monitored by the two comparators shown in the fault timer block. If this voltage reaches the nominal 4-V comparator threshold, the fault is latched, the GATE pin pulled low rapidly, and the FAULT output asserted. The filtered overload signal (OL) can also set the fault latch. Once a fault is latched, capacitor charging ceases (ON signal deasserted) and the timing capacitor is discharged. The TPS2392 latches off in response to faults. Once a fault timeout occurs, the RESET signal turns on a large NMOS device to rapidly discharge the external capacitor, resetting the timer for any subsequent device reset. The TPS2392 can be reset only by cycling power to the device, or by cycling the EN input. In response to a latched fault condition, the TPS2393 enters a fault retry mode, wherein it periodically retries the load to test for continued existence of the fault. In this mode, the FLTTIME capacitor is discharged slowly by a about a 0.4-µA constant-current sink. When the voltage at the FLTTIME pin decays below 0.5 V, the ON signal once again enables the LCA and ramp generator circuits, and a normal turn-on current ramp ensues. Again, during the load charging, the OC signal causes charging of the FLTTIME capacitor until the next delay period elapses. The sequential charging and discharging of the FLTTIME capacitor results in a typical 1% retry duty cycle. If the current-limit fault subsides (GATE pin drives to high-level output), the timing cap is rapidly discharged, duty-cycle operation stops, and the fault latch is reset. For an initial latched fault that was due to an overload condition (i.e., overload comparator response), the latching action causes charging of the timer capacitor, with GATE output already off, to initiate fault retry timing. 18 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 DETAILED DESCRIPTION 4 µs OL 50 µA FAULT S 4V OC S Q R Q + FLTTIME 0.4 µA RETRY 0.5V + RESET ON EN FAULT LOGIC R TPS2393 ONLY See block diagram on page 15 and 16 for pinout. UDG−20118 Figure 27. Fault Timer Block Operation Note that because of the timing inhibit during the initial slow ramp period, the duty cycle in practice is slightly greater than the nominal 1% value. However, sourced current during this period peaks at only about one-eighth the maximum limit. The duty cycle of the normal ramp and constant-current periods will be about 1%. The fault logic within the timer block automatically manages capacitor charge and discharge rates (RESET signal), and the operational status of other device-internal circuits (ON signal). For the TPS2393, the FAULT output remains asserted continuously during retry mode; it is only released if the fault condition clears. 19 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 APPLICATION INFORMATION setting the sense resistor value Due to the current−limiting action of the internal LCA, the maximum allowable load current for an implementation is easily programmed by selecting the appropriate sense resistor value. The LCA acts to limit the sense voltage VI(ISENS) to its internal reference. Once the voltage at the IRAMP pin exceeds approximately 4 V, this limit is the clamp voltage, VREF_K. Therefore, a maximum sense resistor value can be determined from equation (1). R SENSE v 33 mV IMAX (1) where: D RSENSE is the resistor value D IMAX is the desired current limit When setting the sense resistor value, it is important to consider two factors, the minimum current that may be imposed by the TPS2392 or TPS2393, and the maximum load under normal operation of the module. For the first factor, the specification minimum clamp value is used, as seen in equation (1). This method accounts for the tolerance in the sourced current limit below the typical level expected (40 mV/RSENSE). (The clamp measurement includes LCA input offset voltage; therefore, this offset does not have to be factored into the current limit again.) Second, if the load current varies over a range of values under normal operating conditions, then the maximum load level must be allowed for by the value of RSENSE. One example of this is when the load is a switching converter, or brick, which draws higher input current, for a given power output, when the distribution bus is at the low end of its operating range, with decreasing draw at higher supply voltages. To avoid current-limit operation under normal loading, some margin should be designed in between this maximum anticipated load and the minimum current limit level, or IMAX > ILOAD(max), for equation (1). For example, using a 20-mΩ sense resistor for a nominal 1-A load application provides a minimum of 650 mA of overhead for load variance/margin. Typical bulk capacitor charging current during turn-on ia 2 A (40 mV/20 mΩ). setting the inrush slew rate The TPS2392/93 devices enable user-programming of the maximum current slew rate during load start-up events. A capacitor tied to the IRAMP pin (C1 in the typical application diagram) controls the di/dt rate. Once the sense resistor value has been established, a value for ramp capacitor CIRAMP, in microfarads, can be determined from equation (2). C IRAMP + 11 100 R SENSE ǒdtdiǓMAX (2) where: D RSENSE is the sense resistor value in Ω D (di/dt)MAX is the desired maximum slew rate in A/s For example, if the desired slew rate for the typical application shown is 1500 mA/mS, the calculated value for CIRAMP is about 3700 pF. Selecting the next larger standard value of 3900 pF (as shown in the diagram) provides some margin for capacitor and sense resistor tolerances. As described in the Detailed Description section of this datasheet, the TPS2392 and TPS2393 initiate ramp capacitor charging, and consequently, load current di/dt at a reduced rate. This reduced rate applies until the voltage on the IRAMP pin is about 0.5 V. The maximum di/dt rate, as set by equation (2), is effective once the device has switched to the 10-µA charging source. 20 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 APPLICATION INFORMATION setting the fault timing capacitor The fault timeout period is established by the value of the capacitor connected to the FLTTIME pin, CFLT. The timeout period permits riding out spurious current glitches and surges that may occur during operation of the system, and prevents indefinite sourcing into faulted loads swapped into a live system. However, to ensure smooth voltage ramping under all conditions of load capacitance and input supply potential, the minimum timeout should be set to accommodate these system variables. To do this, a rough estimate of the maximum voltage ramp time for a completely discharged plug-in card provides a good basis for setting the minimum timer delay. Due to the three-phase nature of the load current at turn-on, the load voltage ramp has potentially three distinct phases and is seen by comparing Figure 1 and Figure 2. This profile depends on the relative values of load capacitance, input dc potential, maximum current limit and other factors. The first two phases are characterized by the two different slopes of the current ramp; the third phase, if required to complete load charging, is the constant-current charging at IMAX. Considering the two current ramp phases to be one period at an average di/dt simplifies calculation of the required timing capacitor. For the TPS2392 and TPS2393, the typical duration of the soft-start ramp period, tSS, is given by equation (3). t SS + 1183 C IRAMP (3) where: D tSS is the soft-start period in milliseconds, and D CIRAMP is given in µF During this current ramp period, the load voltage magnitude which is attained is estimated by equation (4). V LSS + iAVG 2 CL C IRAMP 100 RSENSE ǒt SSǓ 2 (4) where: D VLSS is the load voltage reached during soft-start D iAVG is 3.38 µA for the TPS2392 and TPS2393 D CL is the amount of the load capacitance D tSS is the soft−start period, in seconds The quantity iAVG in equation (4) is a weighted average of the two charge currents applied to CIRAMP during turn-on, considering the typical output values. If the result of equation (4) is larger than the maximum input supply value, then the load can be expected to charge completely during the inrush slewing portion of the insertion event. However, if this voltage is less than the maximum supply input, VIN(max), the HSPM transitions to the constant-current charging of the load. The remaining amount of time required at IMAX is determined from equation (5). t CC + CL ǒVIN(max) * VLSSǓ ǒ Ǔ V REF_K(min) R SENSE (5) where: D tCC is the constant-current voltage ramp time, in seconds D VREF_K(min) is the minimum clamp voltage, 33 mV. 21 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 APPLICATION INFORMATION With this information, the minimum recommended value timing capacitor CFLT can be determined. The delay time needed will be either tSS or the sum of tSS and tCC, according to the estimated time to charge the load. Since fault timing is generated by the constant-current charging of CFLT, the capacitor value is determined by equation (6) or (7). C FLT(min) + C FLT(min) + 55 t SS 3.75 55 (6) ǒt SS ) t CCǓ 3.75 (7) where: D CFLT(min) is the recommended capacitor value, in microfarads D tSS is the result of equation (3), in seconds D tCC is the result of equation (5), in seconds For the typical application example, with the 100-µF filter capacitor in front of the dc-to-dc converter, equations (3) and (4) estimate the load voltage ramping to −46 V during the soft-start period. If the module should operate down to −72-V input supply, approximately another 1.58 ms of constant-current charging may be required. Therefore, equation (7) is used to determine CFLT(min), and the result is approximately 0.1 µF. setting the undervoltage and overvoltage thresholds The UVLO and OVLO pins can be used to set the undervoltage (VUV) and overvoltage (VOV) thresholds of the hot swap circuit. When the input supply is below VUV or above VOV, the GATE pin is held low, disconnecting power from the load, and deasserting the PG output. When input voltage is within the UV/OV window, the GATE drive is enabled, assuming all other input conditions are valid for turn-on. Threshold hysteresis is provided via two internal sources which are switched to either pin whenever the corresponding input level exceeds the internal 1.4-V reference. The additional bias shifts the pin voltage in proportion to the external resistance connected to it. This small voltage shift at the device pin is gained up by the external divider to input supply levels. GND GND R1 200 kΩ 1% R1 R7 RTN RTN UVLO R2 4.99 kΩ 1% UVLO TPS2392/93* TPS2392/93* OVLO R2 OVLO −VIN R3 3.92 kΩ 1% −VIN R8 −48V −48V (a) (b) V UV_L + R1 ) R2 ) R3 R2 ) R3 V REF V OV_L + R1 ) R2 ) R3 R3 V REF * I SRC_UV R1 V UV_L + R1 ) R2 R2 VTH_UV V OV_L + R7 ) R8 R8 VTH_OV *Additional details omitted for clarity. See block diagram on page 15 and 16 for pinout. Figure 28. Programming the Undervoltage and Overvoltage Thresholds 22 UDG−20119 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 APPLICATION INFORMATION The UV and OV thresholds can be individually programmed with a three-resistor divider connected to it as shown in the typical application diagram, and again in Figure 27a. When the desired trip voltages and undervoltage hysteresis have been established for the protected board, the resistor values needed can be determined from the following equations. Generally, the process is simplest by first selecting the top leg of the divider (R1 in the diagram) needed to obtain the threshold hysteresis. This value is calculated from equation (8). R1 + V HYS_UV 10 mA (8) where: D VHYS_UV is the undervoltage hysteresis value For example, assume the typical application design targets have been set to undervoltage turn-on at 33 V (input supply rising), turn-off at 31 V (input voltage falling), and overvoltage shutdown at 72 V. Then equation (8) yields R1 = 200 kΩ for the 2-V hysteresis. Once the value of R1 is selected, it is used to calculate resistors R2 and R3. R2 + R3 + ȱ V UV_L 1* ȧ ǒV UV_L * 1.4Ǔ Ȳ ǒV OV_L ) 10*5 1.4 ȳ ȧ R1Ǔȴ R1 1.4 R1 VUV_L ǒV UV_L * 1.4Ǔ ǒVOV_L ) 10*5 Ǔ R1 (9) (10) where: D VUV_L is the UVLO threshold when the input supply is low; i.e., less than VUV D VOV_L is the OVLO threshold when the input supply is low; .i.e., less than VOV Again referring to the example schematic, equations (9) and (10) produce R2 = 4.909 kΩ (4.99 kΩ selected) and R3 = 3.951 kΩ (3.92 kΩ selected), as shown. For the selected resistor values, the expected nominal supply thresholds are as shown on the typical application diagram. The hysteresis on the overvoltage threshold, as seen at the supply inputs, is given by the quantity (10 µA) * (R1 + R2). For the majority of applications, this value will be very nearly the same as the UV hysteresis, since typically R1 >> R2. If more independent control is needed for the OVLO hysteresis, there are several options. One option is to use separate dividers for both the UVLO and OVLO pins, as shown in Figure 27b. In this case, once R1 and R7 have been selected for the required hysteresis per equation (8), the bottom resistors in the dividers (R2 and R8 in Figure 27b) can be found from equation (11). R XVLO + VREF ǒVXV_L * VREFǓ RTOP (11) where: D D D D RXVLO is R2 or R8 RTOP is R1 or R7 as appropriate for the threshold being set VXV_L is the under (VUV_L ) or overvoltage (VOV_L ) threshold at the supply input VREF is either VTH_UV or VTH_OV from the specification table, as required for the resistor being calculated capacitor on UVLO pin As shown in the typical application diagram, a minimum 1500 pF capacitor is required on the UVLO pin of the TPS2392 or TPS2393. For some systems, it may be desirable to slow down the response of the controller to undervoltage conditions. For example, if frequent voltage dips are anticipated due to other power events in the system, it may be beneficial to delay somewhat the response of the detection circuit. For these situations, the size of the capacitor can be increased accordingly, over the value shown. 23 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 APPLICATION INFORMATION using the PG output The PG output is an indication of the load power status. PG is asserted after a load turn-on, once the load voltage has ramped up to the input dc level, as indicated by a small VDS drop across the pass FET. The load voltage is sensed by the DRAINSNS pin, which is connected to the pass FET drain through a small-signal blocking diode. Also, the TPS2392 and TPS2393 first confirm that the full programmed sourcing current (typically 40 mV/RSENSE) is available to the load electronics prior to declaring power good. The PG status is latched once the power conditions are met, so that momentary current limiting operation due to input supply transients is not reflected in this output status. This pin can be used to enable downstream converters, provide a visual indication of load power good, or be level-translated or optocoupled to provide status reporting back to the host controller. When using PG to drive the enable input of a converter, care should be taken not to exceed the manufacturer’s maximum voltage ratings for the pin. When asserted, the output driver pulls the PG pin to the −VIN pin potential. Because this status in latched, subsequent current limit operation of the circuit could result in pulling the enable input below the brick’s VIN− potential during the fault timeout period. If the brick does not provide an internal clamp on this pin, a diode can be connected as shown in Figure 28 to externally limit the swing below VIN−. In either case, a resistor (R7 in Figure 28) should be used to limit the current pulled from this pin, protecting both the converter and the PG output. R7 should be large enough to limit the PG input current to less than 10 mA, while still allowing the brick enable to be pulled below its maximum VIL threshold. DC/DC CONVERTER VIN+ GND CIN RTN R7 43 kΩ PG TPS2392* TPS2393* EN VOUT+ VDD 10 µA D3 VIN− VOUT− D1 BAS19 DRNSNS Q1 GATE −VIN ISENS RSENSE −48 V *Additional details omitted for clarity. See block diagram on page 15 and 16 for pinout. Figure 29. TPS2392/TPS2393 Active-Low Converter Enable 24 UDG−20177 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 APPLICATION INFORMATION If the selected converter cannot tolerate any voltage excursions below VIN− potential, an alternative is to drive the enable through an optocoupler. An implementation is shown in Figure 29. DC/DC CONVERTER VIN+ VOUT+ GND VDD R7 CIN EN VIN− RTN PG TPS2392* TPS2393* 10 µA VOUT− D1 BAS19 DRNSNS Q1 GATE −VIN ISENS RSENSE −48 V *Additional details omitted for clarity. See block diagram on page 15 and 16 for pinout. UDG−20178 Figure 30. PG Driving An Optocoupler 25 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 MECHANICAL DATA PW (R-PDSO-G**) PACKAGE PLASTIC SMALL-OUTLINE 14 PINS SHOWN 0,30 0,19 0,65 14 0,10 M 8 0,15 NOM 4,50 4,30 6,60 6,20 Gage Plane 0,25 1 7 0°−ā 8° A 0,75 0,50 Seating Plane 0,15 0,05 1,20 MAX PINS ** 0,10 8 14 16 20 24 28 A MAX 3,10 5,10 5,10 6,60 7,90 9,80 A MIN 2,90 4,90 4,90 6,40 7,70 9,60 DIM 4040064/F 01/97 NOTES:A. All linear dimensions are in millimeters. B. This drawing is subject to change without notice. C. Body dimensions do not include mold flash or protrusion not to exceed 0,15. 26 www.ti.com SLUS536C − AUGUST 2002 − REVISED AUGUST 2004 MECHANICAL DATA DBT (R-PDSO-G**) PACKAGE PLASTIC SMALL-OUTLINE 30 PINS SHOWN 0,50 0,27 0,17 30 16 0,08 M 0,15 NOM 4,50 4,30 6,60 6,20 Gage Plane 0,25 1 15 0°−ā 8° 0,75 0,50 A Seating Plane 0,15 0,05 1,20 MAX 0,10 PINS ** 20 24 28 30 38 44 50 A MAX 5,10 6,60 7,90 7,90 9,80 11,10 12,60 A MIN 4.90 6,40 7,70 7,70 9,60 10,90 12,40 DIM 4073252/E 02/02 NOTES:A. B. C. D. E. All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion. Falls within JEDEC MO-153 Falls within JEDEC MO-153 27 PACKAGE OPTION ADDENDUM www.ti.com 16-Mar-2007 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty TPS2392PW ACTIVE TSSOP PW 14 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TPS2392PWG4 ACTIVE TSSOP PW 14 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TPS2392PWR ACTIVE TSSOP PW 14 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TPS2392PWRG4 ACTIVE TSSOP PW 14 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TPS2393DBT ACTIVE SM8 DBT 44 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TPS2393DBTG4 ACTIVE SM8 DBT 44 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TPS2393DBTR ACTIVE SM8 DBT 44 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TPS2393DBTRG4 ACTIVE SM8 DBT 44 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR TPS2393PW ACTIVE TSSOP PW 14 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TPS2393PWG4 ACTIVE TSSOP PW 14 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TPS2393PWR ACTIVE TSSOP PW 14 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TPS2393PWRG4 ACTIVE TSSOP PW 14 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM Lead/Ball Finish MSL Peak Temp (3) (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. Addendum-Page 1 PACKAGE OPTION ADDENDUM www.ti.com 16-Mar-2007 In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 28-Sep-2007 TAPE AND REEL BOX INFORMATION Device Package Pins Site Reel Diameter (mm) Reel Width (mm) A0 (mm) B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant TPS2392PWR PW 14 SITE 41 330 12 7.0 5.6 1.6 8 12 Q1 TPS2393DBTR DBT 44 SITE 60 330 24 6.8 11.7 1.6 12 24 Q1 TPS2393PWR PW 14 SITE 41 330 12 7.0 5.6 1.6 8 12 Q1 Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com Device 28-Sep-2007 Package Pins Site Length (mm) Width (mm) Height (mm) TPS2392PWR PW 14 SITE 41 346.0 346.0 0.0 TPS2393DBTR DBT 44 SITE 60 367.0 367.0 0.0 TPS2393PWR PW 14 SITE 41 346.0 346.0 0.0 Pack Materials-Page 2 MECHANICAL DATA MTSS001C – JANUARY 1995 – REVISED FEBRUARY 1999 PW (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PINS SHOWN 0,30 0,19 0,65 14 0,10 M 8 0,15 NOM 4,50 4,30 6,60 6,20 Gage Plane 0,25 1 7 0°– 8° A 0,75 0,50 Seating Plane 0,15 0,05 1,20 MAX PINS ** 0,10 8 14 16 20 24 28 A MAX 3,10 5,10 5,10 6,60 7,90 9,80 A MIN 2,90 4,90 4,90 6,40 7,70 9,60 DIM 4040064/F 01/97 NOTES: A. B. C. D. All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0,15. Falls within JEDEC MO-153 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security RFID www.ti-rfid.com Telephony www.ti.com/telephony Low Power Wireless www.ti.com/lpw Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2007, Texas Instruments Incorporated