ETC TXD2000MDKFLLDH

Product Data Sheet
2000 WATT
AC/DC POWER SUPPLY
TXD2000
DESCRIPTION
The TXD2000 Series is a flexible, modular, 2000 Watt
design offering two high current outputs in a 5 x 8 x 12
package. Output voltages from 2.5 VDC through 48
VDC are standard. With Power Factor Correction, EMI
compliance to FCC and CISPR22, CE Mark and
immunity to EN61000-4, the TXD2000 Series is ready
for global deployment. Standard features include
Remote Sense Compensation, Output Voltage
Adjustment, Active Current Sharing, Remote Inhibit,
Power Fail Warning, DC OK Signal and Thermal
Shutdown. An optional ORing diode is offered on
models with an output voltage of 12 VDC or above.
FEATURES
! Wide Range Input of 90-264VAC, 1000 Watts,
High Range Input of 180-264VAC, 2000 Watts,
! Harmonic Correction to EN61000-3-2
! Active Current Sharing
! No Load Operation
! Optional ORing Diode
! 70-80% Efficiencies
! FCC / CISPR 22 Class A EMI Filtering
! Self-Cooled 5”x 8”x 12” Chassis
AGENCY APPROVALS
! EN61000-4 Immunity
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369
TXD2000 2/2000 REV A
Powered by ICminer.com Electronic-Library Service CopyRight 2003
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133
Fax:+353.61.474.141
Page 1
Input Specifications
Parameters
Conditions
Min
Typ
Max
Units
Operating Range
1000W
47-63Hz
90
264
VAC
2000W
47-63Hz
180
264
VAC
120VAC, 25 C, cold start
80
Apk
240VAC, 250C, cold start
160
0
Inrush Current
Efficiency
Holdup
Power Factor
(1)
Nominal line, full load
70
Full load
20
75
Apk
80
%
m sec
Full load
0.99
Notes: (1) Harmonic currents meet EN61000-3-2
Output Voltage Modules and Maximum Rated Load
Output
Output Voltage
Voltage Code
Voltage
Output Current
(Maximum Continuous)
Output Power
(Maximum Continuous)
A
5.0
200A
1000W
B
12.0
83A
1000W
C
15.0
67A
1000W
D
18.0
55A
1000W
E
24.0
42A
1000W
F
28.0
36A
1000W
G
36.0
28A
1000W
1000W
H
48.0
21A
J
20.0
40A
800W
K
3.3
182A
600W
L
2.5
200A
500W
Output Specifications
Parameter
Conditions
Output Power
All environmental and line conditions
Min
Typ
90-264VAC
180-264VAC
Limited by output module selection
Voltage Adjustment Range
Relative to nominal output voltage
Output Regulation
Line, load or cross
Minimum Load
Max
Units
1000
Watts
2000
Watts
+0.2
%
+5
%
0
PARD
Measured at output terminals, 20MHz
Temperature Coefficient
00 to 500C
Amps
50 mv or 1%
pk-pk
%/0C
+0.2
Environmental Specifications
Parameter
Conditions
Ambient Temperature
(Operating)
Output de-rated linearly to 50% of
rated capacity between 500C and 700C
Ambient Temperature
Non-operating
Min
Typ
Max
Units
0
+70
0
C
-50
+85
0
C
Altitude (Operating)
-200
+10,000
Feet
Altitude (Non-operating)
-200
+50,000
Feet
Shock
Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test
Vibration
Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test
Cooling
The TXD2000 is provided with internal cooling fans.
Page 2
Powered by ICminer.com Electronic-Library Service CopyRight 2003
TXD2000 2/2000 REV A
Product Features
Features
Characteristic
Remote Sense
500mV compensation
Active Current Sharing
Single Wire; 5% current share if outputs are over 25% of rated load
ORing Diode
Optional (not available on modules below 12V)
OVP
125% of nominal (+7.5%)
Thermal Shutdown
Automatic Restart
DC OK Signal
Logic “1” when output is within +3% of nominal
Power Fail Warning
Transition to Logic “0” at least 5msec before loss of output regulation
Remote Inhibit
Logic “0” applied will inhibit output (referenced to –Sense terminal)
Product Compliances
Approval
Characteristic
UL and cUL
UL1950, 3rd Edition (1)
VDE
EN60950
FCC
Class A requirements for conducted emissions
CISPR 22
Class A requirements for conducted emissions
EN61000-4-2
Electrostatic Discharge, Level 4
EN61000-4-4
Electrical Fast Transients, Level 3
EN61000-4-5
Input Surge Immunity, Level 3
EN61000-3-2
Harmonic Currents, Class A
CE Mark
Low Voltage Directive
rd
Notes: (1) UL1950, 3 Edition incorporates the requirements of CSA 950.
Ordering Information
Model Designation
TXD2000
BASE MODEL
F
L
L
H
Chassis: “8” = 5” x 8” x 12”; “M” = modified
Output Voltage Module A: (see chart below)
Output Voltage Module B: (see chart below)
Standard Fan: “F”:
Remote Inhibit - TTL Logic Level “0” turns the power supply OFF:
Power Fail Warning - TTL Logic Level “0” indicates AC is LOST:
ORing Diode - “D” indicates an ORing Diode is installed in each module; “N” = None:
DC OK - TTL Logic Level “1” indicates DC is OK:
OUTPUT VOLTAGES
A = 5V
G = 36V
B = 12V
H = 48V
C = 15V
J = 20V
D = 18V
K = 3.3V
E = 24V
L = 2.5V
F = 28V
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice.
No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES
product for use in life support devices/systems or in aircraft control applications.
TXD2000 2/2000 REV A
Powered by ICminer.com Electronic-Library Service CopyRight 2003
Page 3
MECHANICAL
MODULE
CONTROL CONNECTOR
REMOTE INHIBIT
DC OK
N/C
N/C
POWER FAIL WARNING
CURRENT SHARE
+ SENSE
N/C
_ SENSE
N/C
FUNCTION
AMP NO. 87579-2 OR EQUIVALENT
PIN
NO.
1
2
3
4
5
6
7
8
9
10
.19 MAX.
AIR FLOW
12.00
6.375
1.22
.60
5.00
6.000
.95
.315 TYP.
1.85
8-32UNC-2B
25 MAX. SCREW PENETRATION
4 PLACES
1.95
ADJ
3.45
SCALE: NONE
PIN 1
6.38
V1
ADJ.
DETAIL A
8.00
ADJ.
V2
1/4-20 UNC-2A
HEX HEAD SCREW
4 PLACES
TB1
6-32 UNF-2A PHILSLOT
TORQUE TO 9 INCH/LBS. MAX
3 PLACES
1.00
1.60
Powered by ICminer.com Electronic-Library Service CopyRight 2003
TXD2000 2/2000 REV A
Page 4