TOSHIBA U30QWK2C53

U30QWK2C53
TOSHIBA Schottky Barrier Rectifier Stack Trench Schottky Barrier Type
U30QWK2C53
Switching Mode Power Supply Application
Converter&Chopper Application
·
Repetitive peak reverse voltage: VRRM = 120 V
·
Peak forward voltage: VFM = 0.85 V (max)
·
Average output recified current: IO = 30 A
·
Power surface mount device for thin flat package.
·
“TFP” (Toshiba package name)
Unit: mm
Maximum Ratings (Ta = 25°C)
Characteristics
Symbol
Rating
Unit
Repetitive peak reverse voltage
VRRM
120
V
Average output recified current
IO
30
A
Peak one cycle surge forward current
(non-repetitive, sine wave)
Junction temperature
Storage temperature range
IFSM
100 (50 Hz)
110 (60 Hz)
A
Tj
-40 to 150
°C
JEDEC
―
Tstg
-40 to 150
°C
JEITA
―
TOSHIBA
12-9B1A
Weight: 0.74 g (typ.)
Polarity
③K
*①A1
②A2
*: Common Terminal
Handling Precaution
Schottky barrier diodes are having large-reverse-current-leakage characteristic compare to other rectifier
products. This current leakage and not proper operating temperature or voltage may cause thermal runaway.
Please take forward and reverse loss into consideration when you design.
1
2003-02-17
U30QWK2C53
Electrical Characteristics (Ta = 25°C)
Characteristics
Symbol
Test Condition
Min
Typ.
Max
Unit
Peak forward voltage
VFM
IFM = 15 A
¾
¾
0.85
V
Repetitive peak reverse current
IRRM
VRRM = 120 V
¾
¾
50
mA
VR = 10 V, f = 1.0 MHz
¾
230
¾
pF
DC Total, Junction to Case
¾
¾
1.2
°C/W
Junction Capacitance
Cj
Thermal resistance
Rth (j-c)
Note: VFM, IRRM, Cj: A value of one cell.
Marking
MARK
※1
※1
30QWK2C
TYPE
U30QWK2C53
Lot Number
Month (starting from alphabet A)
※2
※2
Year (last number of the christian era)
Standard Soldering Pad
unit: mm
2.0
2.0
2.5
2.0
6.0
8.0
3.2
3.8
2
2003-02-17
U30QWK2C53
iF – vF
PF (AV) – Io
100
32
Average forward power dissipation
PF (AV) (W)
Instantaneous forward current
iF
(A)
One cell
Tj = 150°C
10
100°C
75°C
25°C
1
0.1
0.0
0.2
0.4
0.6
0.8
1.0
Instantaneous forward voltage
1.2
vF
24
16
8
0° a 360°
4
4
8
12
16
20
24
180°
90° 120°
60°
sin
Rectangular
waveform
(one cell)
80
60
40
0° a 360°
Conduction
angle a
4
8
12
16
20
Io
24
Average output rectified current
28
Io
32
100
36
(A)
80
60
40
60 Hz
50 Hz
20
0
1
36
(A)
10
100
Number of cycles
rth (j-c) – t
Cj – VR
(typical)
1000
10
One cell
f = 1 MHz
(pF)
Ta = 25°C
One cell
Cj
Junction capacitance
Transient thermal impedance
rth (j-c) (°C/W)
32
One cell
Single phase full
Sine wave
Ta = 25°C
(A)
120
a = 30°
28
Surge forward current (non-repetitive)
120
Peak surge forward current IFSM
Maximum allowable case temperature
Tc max (°C)
Conduction
angle a
Average output rectified current
140
0
0
Rectangular
waveform
(one cell)
a = 30°
12
Tc max – Io
20
90°
60°
20
(V)
160
100
180°
120°
0
0
1.4
sin
28
1
0.1
0.001
0.01
0.1
1
10
100
100
10
1
1000
Time t (s)
10
100
Reverse voltage VR (V)
3
2003-02-17
U30QWK2C53
I R – Tj
(typical)
PR (AV) – VR
100
Pulse measurement
Average reverse power dissipation
PR (AV) (W)
(mA)
Reverse current IR
50
120
(one cell)
10
1
0.1
0.01
0.001
0
100
3.2
Rectangular
waveform
2.8
0°
2.4
2.0
1.6
(typical)
360°
DC
VR
Conduction
angle a
Tj = 150°C
300°
240°
1.2
180°
120°
0.8
60°
0.4
VR = 10 V
30
20
40
60
80
100
Junction temperature Tj
120
140
0.0
0
160
20
40
60
80
Reverse voltage VR
(°C)
4
100
120
(V)
2003-02-17
U30QWK2C53
RESTRICTIONS ON PRODUCT USE
000707EAA
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
5
2003-02-17