ACDC 5 Watts VCP Series xppower.com • Low Cost • Universal AC Input • Output Voltage from 5 to 15 V • PCB Mount • Class II Construction • EN55022 Class B Emissions • No Load Input Power <0.3 W B R A N D Specification Input General • • • • • • • 90-264 VAC 47-63 Hz 0.2 A max at 90 VAC 40 A max at 240 VAC, cold start at 25 °C EN61000-3-2, class A <0.3 W Internal T1.6A/250 V fuse in line Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient • • • • • See table ±5% at 50% load No minimum load required 2 s max 100 ms typical 5 ms typical at full load and 115 VAC ±0.5% max 2% max, 0-100% load 10% max. deviation, recovery to <1% within 500 µs for a 50% step load change at 0.2 A/µs See table See table 120-180%, auto recovery Trip and restart (hiccup mode) 0.2 %/˚C Input Voltage Input Frequency Input Current Inrush Current Power Factor No Load Input Power Input Protection Output Efficiency Isolation Switching Frequency MTBF • • • • See table 3000 VAC Input to Output 60 kHz typical 250 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • 0 ˚C to +70 ˚C, derate from 100% load at 50 °C to 50% load at 70 °C Cooling • Natural convection Operating Humidity • 10-90% RH, non-condensing Storage Temperature • -20 ˚C to +80 ˚C Shock • Able to survive 1 m drop onto concrete on each of 6 axes Vibration • 10-300 Hz, 2 g 15 mins/sweep. 30 mins for each of 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity • • • • Radiated Immunity EFT/Burst Surge • • • Conducted Immunity Magnetic Field Dips & Interruptions • • • Safety Approvals • EN55022, level B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, ±4kV contact, ±8kV air, Perf Criteria A EN61000-4-3, 3 V/m, Perf Criteria A EN61000-4-4, level 2, Perf Criteria A EN61000-4-5 installation class 3, Perf Criteria A EN61000-4-6, 3 V, Perf Criteria A EN61000-4-8, 1 A/m, Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60950-1, cUL60950-1, IEC60950-1 Output Power Output Voltage(2) Output Current Ripple & Noise(1) OVP Setting(3) Efficiency(4) 5.0 W 4.8 W 4.5 W 5.0 V 12.0 V 15.0 V 1.0 A 0.4 A 0.3 A 150 mV 150 mV 150 mV 10.0 V 20.0 V 25.0 V 69% 69% 69% Model Number VCP05US05†^ VCP05US12†^ VCP05US15†^ Notes 1. Measured at DC output connector using 20 MHz bandwidth and 0.1 µF ceramic capacitor in parallel with 10 µF electrolytic capacitor placed at connector terminals 2. Other voltages between 3.0 V and 15.0 V are available, consult sales for details. 3. Typical trip point. 4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input. † Available from Farnell & element14. See page 28. ^ Available from Newark. See page 28. Mechanical Details 2.3 (58.5) 1.15 (29.25) 1.05 (26.7) 0.75 (19.1) 0.59 (15) 0.19 (4.8) 1 1.4 (35.5) 4 TOP VIEW 0.05 (1.2) 0.62 (15.8) 5 2 3 1.01 (25.7) 0.4 (10) 0.67 (17.02) 0.06 (1.60) 0.99 (25.2) ø 0.040 (ø1.00) 0.15 (3.80) 0.18 (4.50) ø 0.070 (ø1.80) Pin Designation 1 No connection 2 Neutral 3 Live 4 Output -VE 5 Output +VE Notes 1. All dimensions are in inches (mm). 2. Weight: 0.04 lbs (20 g) approx. 3. Tolerance: x.x = ±0.04 (x.x = ±1.0), x.xx = ±0.02 (x.xx = ±0.5) 15-May-12 ACDC VCP05 Models and Ratings