JDSU WRT-740DT240B-156

COMMUNICATIONS MODULES & SUBSYSTEMS
Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol,
DWDM, 3R Transponder
WaveReady™ Transponder 740 XLR
Key Features
• Client-side SFP modules support either single-mode
fiber (SMF) or multimode fiber (MMF)
• Automatic bit-rate detection and reporting
• Multiple protocols supported at discrete bit rates of
125 Mb/s to 3.125 Gb/s
• Network optics support 16 ITU wavelengths on a 100 GHz
grid over distances up to 180 km, without dispersion
compensation or amplification
• Facility loopback functionality on both network and
client sides
• Remote management via SNMP traps or TL1
• 3R functionality at all supported bit rates and protocols
Applications
• Wavelength services
• Metro optical access overlay
• Storage area network (SAN) and
GigE extension services
Compliance
• FCC Part 15 (Class A); UL 60950
3rd Edition, December 2000;
CAN/CSA-C22.2 No. 950-95;
NEBS Level 3; GR-63-CORE;
GR-1089-CORE; GR-78-CORE; CE;
IEC 60950; ETS300-386; EN 55022
(Class B); 73/23/EEC
The WaveReady Transponder 740 (WRT-740) is a multi-rate, multi-protocol,
auto-lock module that translates optical signals between a variety of client-side
interfaces into a long-reach, single-mode, dense wavelength division multiplexing
(DWDM) interface. This module includes small form factor pluggable (SFP)
modules on the client side, loopback, and 3R (reshape, retime and reamplify/regenerate) functionality.
SFP modules optimized for a wide range of protocols are available for singlemode and multimode fiber. Supported protocols include 100Base-FX Ethernet,
Gigabit Ethernet (GigE), ESCON, Fibre channel, FICON, and OC-3 to OC-48.
Supported data rates range from 125 Mb/s to 3.125 Gb/s. The WRT-740's bit-rate
and protocol independence gives service providers the flexibility to meet the
shifting service demands of customers without changing installed equipment.
Remote management lowers operating, administration and management
expenditures (OPEX). A WaveReady communications module manages the WRT740 with TL1 and a command line or telnet interface, or with TL1 or simple
network management protocol (SNMP) and the JDSU Node Manager software.
An embedded supervisory channel on the network side is also available for remote
management of standalone modules without the cost of extra fiber or an extra
WaveReady communications module.
Full 3R functionality allows multiple WRT-740 modules to be deployed in series
for very long reach applications. Loopback facilitates fault isolation and
troubleshooting.
NORTH AMERICA : 800 498-JDSU (5378)
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com
WRT-740
2
Point-to-Point Four-Channel DWDM Link
WaveReady 3500-F Shelf
WaveReady 3500-F Shelf
MON
RX
MON
TX
RX
RX
TX
TX
TX
RX
WS 540
RX
TX
WSRX
540
RX
TX
TX
WSRX
540
TX
WRT-740
WS
540
TX
RX
TX
WS 540
RX
TX
WSRX
540
TX
RX
TX
WSRX
540
TX
WS
540
WRT-740
TX
RX
RX
TX
MON
RX
MON
Typical Link Budget
Data Rate
Minimum Rx Power
Total Power Budget
Maximum Distance
OC-48
Gigabit Ethernet
-28.5 dBm
-30 dBm
27.9 dB
29.4 dB
111 km
117 km
Point-to-point Single Channel DWDM Link
Typical Link Budget
Data Rate
Minimum Rx Power
Total Power Budget
Maximum Distance
OC-48
Gigabit Ethernet
-28.5 dBm
-30 dBm
33.5 dB
35 dB
134 km
140 km
WRT-740
3
Network Optical Specifications
Parameter
Optical Path between Transmitter and Receiver Connectors
Dispersion at OC-48
Optical return loss of cable plant, including any connectors
Discrete reflectance between transmit and receive connectors
Maximum link budget at OC-48 including dispersion
Transmitter
Wavelength range on ITU grid
Frequency range (32 frequencies, 100 GHz spacing)
Wavelength accuracy
Mean output power
Extinction ratio
Receiver
Sensitivity at 100BaseF to GE, BER=1x10-10
Sensitivity at OC-48, BER=1x10-10
Overload
OSNR tolerance at BER=1x10-12
Optical path penalty on standard single-mode fiber
Reflectance of receiver at receiver connector
LOS activation threshold
LOS deactivation threshold
Specifications
Maximum
Minimum
Maximum
Minimum
Typical
3240 ps/nm
24 dB
27 dB
31.5 dB
36 dB
Maximum
Minimum
Typical
Maximum
Minimum
Typical
1530 to 1561 nm
192.1 to 195.9 THz
100 pm
5 dBm
7 dBm
10 dBm
8.2 dB
9.5 dB 1
Minimum
Minimum
Minimum
Minimum
Maximum
Maximum
Typical
Typical
-30 dBm
-28.5 dBm
-8 dBm 2
20 dB 3
2 dB 4
-27 dB
-32 dBm
-30 dBm
Note: All specifications are guaranteed over the life, operating temperatures, wavelength range, and input voltage range specified. This product should be deployed in
accordance with each company's deployment directives.
1. At OC-48
2. Management communications at OC-3 require input power less than -15 dBm
3. With receive power of -27 dBm with no other signal impairments at EOL over all temperature ranges
4. Dispersion penalty only
WRT-740
4
Other Specifications
Parameter
Condition
Specifications
Electrical
Power consumption
Over temperature range EOL
Supply voltage1
Environmental
Storage temperature
Ambient operating temperature
Humidity
Mechanical
Weight (approximate)
Dimensions (WxHxD)
Typical
Maximum
Minimum
Typical
Maximum
-5 to 55 °C short term, 96 hours continuous.
No more than 15 days per year.
Non-condensing
16.5 W
20 W
38 V
48 V
60 V
-40 to 85 °C
-5 to 55 °C
5 to 95%
1.4 kg (3.1 pounds)
25.4 x 223.5 x 175 mm
(1.0 x 6.89 x 8.8 inches)
WaveReady 3500-F or fan-equipped
WaveReady 3100 shelf in standard
19- or 24-inch rack
Mounting options
1. The DC power supply must be -48 V SELV output and certified by a nationally recognized test laboratory (NRTL)
Interface Specifications
Parameter
Specification
Provisioning, operations, administration, maintenance
Via the WaveReady Communication Module 200. Remote management:
SNMP and TL1 command mode through JDS Uniphase Node Manager
software or TL1 through telnet or command-line application or SNMP.
Communication with remote modules through an embedded supervisory channel.
CARD (power), MAJ/CRIT (major or critical alarm), MIN (minor alarm),
LOS B, LOS D, LOS F (loss of lock) LOOPBK (loopback), MGT (management).
Client side ports A and B single mode or multimode fiber (SMF or MMF),
SFP1, SFP2, SFP3, SFP4 or SFP5.
Network side ports: C and D, SMF.
CARD (power), MAJ/CRIT (major or critical alarm), MIN (minor alarm),
LOS B, LOS D (loss of lock). Alarm relay open under normal operation.
Relay closed when power is off and alarm is active.
Front panel LEDs
Front panel ports
Alarms
WRT-740
5
Compatibility of Client SFPs
Protocol
SMF Fiber
100Base-FX Ethernet
OC-3 IR-1/STM-1 S-1.1
ESCON
D1 video
OC-12/STM-4 S-4.1
FICON LX single mode
Fibre channel 100-SMLL-L
Gigabit Ethernet 1000Base-LX
Fibre channel 200-SMLL-I
OC-48/STM-16 I-16
OC-48 FEC
MMF Fiber
100Base-FX Ethernet
ESCON
FICON LX
FICON SX
Fibre channel 100-M5-SN-I
Gigabit Ethernet 1000Base-SX
Bit Rate
SFP
125 Mb/s
155.52 Mb/s
200 Mb/s
270 Mb/s
622.08 Mb/s
1.0625 Gb/s
1.0625 Gb/s
1.250 Gb/s
2.125 Gb/s
2.48832 Gb/s
2.7 Gb/s
SFP1 and SFP2
SFP1 and SFP2
SFP1 and SFP2
SFP1 and SFP2
SFP1 and SFP2
SFP1
SFP1
SFP1
SFP1
SFP1
SFP1
125 Mb/s
200 Mb/s
1.0625 Gb/s
1.0625 Gb/s
1.0625 Gb/s
1.250 Gb/s
SFP2
SFP2 or SFP11
SFP3 or SFP11
SFP4
SFP4
SFP4
1. Due to the dual media (single-mode and multimode) support of this transmitter, fulfillment of this protocol requires a single-mode fiber offset launch mode conditioning
patch cord. The offset launch mode conditioning cable lowers the launch power by 0.5 dB and incurs a similar penalty on the sensitivity.
WRT-740
6
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
[email protected].
Sample: WRT-740DT240B-153
WRT-740DT240BCode
135
137
144
145
146
147
148
149
152
153
154
155
156
157
158
159
ITU Channel/Frequency1
193.5 THz/1549.32 nm
193.7 THz/1547.72 nm
194.4 THz/1542.14 nm
194.5 THz/1541.35 nm
194.6 THz/1540.56 nm
194.7 THz/1539.77 nm
194.8 THz/1538.98 nm
194.9 THz/1538.19 nm
195.2 THz/1535.82 nm
195.3 THz/1535.04 nm
195.4 THz/1534.25 nm
195.5 THz/1533.47 nm
195.6 THz/1532.68 nm
195.7 THz/1531.90 nm
195.8 THz/1531.12 nm
195.9 THz/1530.33 nm
1. Other channels are available upon request.
SFP Sample: WRT-SFPS12SB1310
WRT-SFP
Code
S24SB1310
S12SB1310
M20SB0850
S20SB1310
Model
SFP1
SFP2
SFP3
SFP4
All statements, technical information and recommendations related to the products herein are based upon information believed to be
reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any
inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves
the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products
herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU, Waveready, and the
JDSU logo are trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders. ©2005 JDS
Uniphase Corporation. All rights reserved. 10143107 Rev. 004 0808 WRT740.DS.CMS.AE
NORTH AMERICA : 800 498-JDSU (5378)
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com