FKI Power Entry Modules with Line Filter www.schurter.com/pg06 IEC Appliance Inlet C14 with Filter, Fuseholder 2-pole, Line Switch 2-pole Standard- or Medical-Filter on phase-out C14 70° C Description -Panel Mount: Screw-on mounting from front side -4 Functions: Appliance Inlet Protection class I, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole, Line filter in standard and medical version -Quick connect terminals 6.3 x 0.8 mm Approvals -VDE License Number: 40004665 -UL License Number: E72928 Characteristics -Compact design with optimal shielding -All single elements are already wired -Plug removal necessary for fuse-link replacement If the power entry module is installed as normal, it is not possible to touch any live parts with the test-finger according to IEC60529 Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front -With EMC-shield -Qualified for use in equipment according IEC/EN 60950 Other versions on request -Medical version M80 References General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, Mating Connectors, Distributor-StockCheck, Accessories Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class 1 acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet Fuseholder Rated Power Acceptance @ Ta 23 °C Power Acceptance @ Ta > 23°C Line Switch Line Filter MTBF EMC Products C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 2-pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 1.6 W (2-pole) Admissible power acceptance at higher ambient temperature see derating curves Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details Standard and Medical Version, IEC 60939, IEC 60601‑1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details > 1'700'000 h acc. to MIL-HB-217 F FKI Power Entry Modules with Line Filter www.schurter.com/pg06 Dimensions Case 45 recommend for new designs 55 mm 40 ±0.15 61±0.5 R1 60.2 6.3x0.8 ø 5.8x90° 49.5 ø 3.2 63 65 ±0.5 40 M3 3.5 28 R3 50 ±0.5 29.5±0.5 14 5.5 61.5 28.7 67 Case 50 on phase-out 40 ±0.15 61±0.5 R1 60.2 ø 3.2 6.3x0.8 ø 5.8x90° 49.5 63 65 ±0.5 40 M3 3.5 28 R3 50 ±0.5 15 5.5 41 28.7 55 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 10 68 2.2 1 2 Standard Version 2x4 68 2.2 1 4 Standard Version 2 x 1.5 68 2.2 1 6 Standard Version 2 x 0.8 68 2.2 1 10 Standard Version 2 x 0.3 68 2.2 1 1 Medical Version (M5) 2 x 10 68 - 1 2 Medical Version (M5) 2x4 68 - 1 4 Medical Version (M5) 2 x 1.5 68 - 1 6 Medical Version (M5) 2 x 0.8 68 - 1 10 Medical Version (M5) 2 x 0.3 68 - 1 EMC Products 29.5±0.5 FKI Power Entry Modules with Line Filter www.schurter.com/pg06 Diagrams Standard version Medical version N N’ F2 1) PE L 1) Line 2) only FKI 3) Load L1 R F1 Cx L2 Cx PE’ 2) L’ 1) Line 2) Load Admissible power acceptance in Watt per pole Derating Curves 2-pole 1.6 1.4 1.2 I = 1.0 In 1.0 0.8 I = 0.7 In 0.6 I = < < In 0.4 0.2 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C Attenuation Loss Standard version 1A - - - - differential mode _____ common mode 2A 4A 6A 2A 4A 6A 10 A Medical version (M5) 1A 10 A EMC Products FKI Power Entry Modules with Line Filter www.schurter.com/pg06 Variants Socket and fuse drawer included Type Rated Current [A] Filter-Type Fuseholder Line Switch Housing Material: Housing Comment Order Number FKI 1 Standard Version 2-pole 2-pole 45 Aluminum - 4304.4061 FKI 2 Standard Version 2-pole 2-pole 45 Aluminum - 4304.4062 FKI 4 Standard Version 2-pole 2-pole 45 Aluminum - 4304.4063 FKI 6 Standard Version 2-pole 2-pole 45 Aluminum - 4304.4064 FKI 10 Standard Version 2-pole 2-pole 45 Aluminum - 4304.4065 FKI 1 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.4091 FKI 2 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.4092 FKI 4 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.4092 FKI 6 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.4094 FKI 10 Medical Version (M5) 2-pole 2-pole 45 Aluminum - 4304.4095 FKI 1 Standard Version 2-pole 2-pole 50 Nickel plated steel 1) 4304.4021 FKI 2 Standard Version 2-pole 2-pole 50 Nickel plated steel 1) 4304.4022 FKI 4 Standard Version 2-pole 2-pole 50 Nickel plated steel 1) 4304.4023 FKI 6 Standard Version 2-pole 2-pole 50 Nickel plated steel 1) 4304.4024 FKI 10 Standard Version 2-pole 2-pole 50 Nickel plated steel 1) 4304.4025 FKI 1 Medical Version (M5) 2-pole 2-pole 50 Nickel plated steel 1) 4304.4066 FKI 2 Medical Version (M5) 2-pole 2-pole 50 Nickel plated steel 1) 4304.4067 FKI 4 Medical Version (M5) 2-pole 2-pole 50 Nickel plated steel 1) 4304.4068 FKI 6 Medical Version (M5) 2-pole 2-pole 50 Nickel plated steel 1) 4304.4069 FKI 10 Medical Version (M5) 2-pole 2-pole 50 Nickel plated steel 1) 4304.4070 1) Versions with nickel plated steel enclosure are on phase-out. For new designs we recommend the versions with aluminum enclosure. Packaging unit 10 Pcs Accessories Description Assorted Covers Rear Cover 0859.0074 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 5092 Appliance Outlet further types to FKI Connector Overview complete IEC Connector C15, Rewireable, Straight 0101 IEC Connector C15A, Rewireable, Straight 0102 IEC Connector C15A, Rewireable, Straight 0102-G IEC Connector C15A, Rewireable, Angled 0112 IEC Connector C13, Rewireable, Angled 4012 Connector further types to FKI ... EMC Products FKI Power Entry Modules with Line Filter www.schurter.com/pg06 Category / Description Power Cord Overview complete Power Cord with IEC Connector C13, Angled 0311 Power Cord with IEC Connector C13, Angled 3011 Power Cord with IEC Connector C13, Angled 3012 Power Cord with IEC Connector C13, Angled 3013 Power Cord with IEC Connector C13 3020 Power Cord further types to FKI ... The specifications, descriptions and illustrations indicated in this document are based on EMC Products current information. All content is subject to modifications and amendments.