ICMIC YWW7640AF

TM
This X76F400 device has been acquired by
IC MICROSYSTEMS from Xicor, Inc.
4K
ICmic
IC MICROSYSTEMS
512 x 8 bit
X76F400
Secure SerialFlash
FEATURES
DESCRIPTION
•64-bit password security
•One array (496 bytes) two passwords (16 bytes)
—Read password
—Write password
•Programmable passwords
•Retry counter register
—Allows 8 tries before clearing of the array
•32-bit response to reset (RST input)
•8 byte sector write mode
•1MHz clock rate •2-wire
serial interface •Low
power CMOS
—2.5 to 5.5V operation
—Standby current less than 1µA
—Active current less than 3 mA
•High reliability endurance:
—100,000 write cycles
•Data retention: 100 years
•Available in:
The X76F400 is a password access security supervisor,
containing one 3968-bit Secure Serial Flash array.
Access to the memory array can be controlled by two 64-bit
passwords. These passwords protect read and
write operations of the memory array.
The X76F400 features a serial interface and software
protocol allowing operation on a popular 2-wire bus.
The bus signals are a clock input (SCL) and a bi-directional
data input and output (SDA).
The X76F400 also features a synchronous response to
reset, providing an automatic output of a hard-wired
32-bit data stream, thereby meeting the industry standard
for memory cards.
The X76F400 utilizes Xicor’s proprietary Direct Write ™
cell, providing a minimum endurance of 100,000
cycles and a minimum data retention of 100 years.
—8-lead, SOIC,TSSOP
BLOCK DIAGRAM
Retry Counter
Data Transfer
SCL
SDA
Erase Logic
Array Access
Enable
Interface
Logic
496 Byte
EEPROM Array
Password Array
and Password
Verification Logic
RST
ISO Reset
Response Register
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
1 of 14
X76F400
PIN DESCRIPTIONS
If the X76F400 is in a nonvolatile write cycle a “no ACK”
(SDA = High) response will be issued in
Serial Clock (SCL)
response to loading of the command byte. If a stop is issued
prior to the nonvolatile write cycle, the write
The SCL input is used to clock all data into and out of the
device.
Serial Data (SDA)
operation will be terminated; the part will then reset and
enter into a standby mode.
(The basic sequence is illustrated in Figure 1.)
SDA is an open drain serial data input/output pin. During a
read cycle, data is shifted out on this pin. During
a write cycle, data is shifted in on this pin. In all other
cases, this pin is in a high impedance state.
PIN NAMES
Symbol
Description
SDA
Serial Data Input/Output
Reset (RST)
SCL
Serial Clock Input
RST is a device reset pin. When RST is pulsed high, the
X76F400 will output 32 bits of fixed data, which
RST
Reset Input
VCC
Supply Voltage
VSS
Ground
NC
No Connect
conforms to the standard for “synchronous responseto-reset.” The part must not be in a write cycle for the
response-to-reset to occur. See Figure 7. If power is
interrupted during the response-to-reset, the response-
to-reset will be aborted and the part will return to the
standby state. The response to reset is “mask
PIN CONFIGURATION
programmable” only!
SOIC
DEVICE OPERATION
The X76F400 memory array consists of 62 8-byte sectors.
Read or write access to the array always begins at
the first address of the sector. Read operations then can
continue indefinitely. Write operations must total 8 bytes.
There are two primary modes of operation for the
X76F400; Protected READ and protected WRITE. Pro-
VSS
1
8
VCC
NC
2
7
RST
SDA
3
6
SCL
NC
4
5
NC
RST
TSSOP
tected operations must be performed with one of two 8- byte
passwords.
The basic method of communication for the device is
generating a start condition, then transmitting a com-
VCC
1
8
NC
2
7
SCL
NC
3
6
SDA
VSS
4
5
NC
mand, followed by the correct password. All parts will be
shipped from the factory with all passwords equal to ‘0.’
The user must perform ACK polling to determine the
validity of the password, prior to starting a data transfer
After each transaction is completed, the X76F400 will
reset and enter into a standby mode. This will also be
(see Acknowledge Polling). Only after the correct password
is accepted, and an ACK polling has been
the response if an unsuccessful attempt is made to
access a protected array.
performed, can the data transfer occur. See Figure 1.
To ensure the correct communication, RST must
remain LOW under all conditions except when running
a “response-to-reset sequence”.
Data is transferred in 8-bit segments, with each transfer
being followed by an ACK, generated by the receiving
device.
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
2 of 14
X76F400
Figure 1. X76F400 Device Operation
Clock and Data Conventions
Data states on the SDA line can change only during SCL
LOW. SDA changes during SCL HIGH are
Load Command/Address Byte
reserved for indicating start and stop conditions. Refer to
Figures 2 and 3.
Load 8-Byte
Password
Start Condition
All commands are preceded by the start condition, which
is a HIGH to LOW transition of SDA when SCL is
Verify Password
HIGH. The X76F400 continuously monitors the SDA and
SCL lines for the start condition, and will not
Acceptance by
Use of ACK Polling
respond to any command until this condition is met.
A start may be issued to terminate the input of a control
byte or the input data to be written. This will reset
Read/Write
Data Bytes
the device and leave it ready to begin a new read or write
command. Because of the push/pull output, a
start cannot be generated while the part is outputting data.
Starts are inhibited while a write is in progress.
Retry Counter
The X76F400 contains a retry counter. The retry
counter allows 8 accesses with an invalid password
before any action is taken. The counter will increment with
any combination of incorrect passwords. If the
retry counter overflows, the memory area and both of the
passwords are cleared to “0.” If a correct password
is received prior to retry counter overflow, the retry
counter is reset and access is granted.
Stop Condition
All communications must be terminated by a stop condition. The stop condition is a LOW to HIGH transition
of SDA when SCL is HIGH. The stop condition is also used
to reset the device during a command or data
input sequence, leaving the device in the standby
power mode. As with starts, stops are inhibited when
outputting data and while a write is in progress.
Device Protocol
The X76F400 supports a bi-directional bus oriented
protocol. The protocol defines any device that sends
data onto the bus as a transmitter and the receiving
device as a receiver. The device controlling the transfer
is a master and the device being controlled is the slave.
The master will always initiate data transfers and
provide the clock for both transmit and receive operations.
Therefore, the X76F400 will be considered a
slave in all applications.
Acknowledge
Acknowledge is a software convention used to indicate
successful data transfer. The transmitting device, either
master or slave, will release the bus after transmitting 8 bits.
During the ninth clock cycle the receiver will pull
the SDA line LOW to acknowledge that it received the 8
bits of data.
The X76F400 will respond with an acknowledge after
recognition of a start condition and its slave address. If
both the device and a write condition have been
selected, the X76F400 will respond with an acknowl-
edge after the receipt of each subsequent 8-bit word.
Figure 2. Data Validity
SCL
SDA
Data Stable
REV 1.0 7/5/00
Data
Change
www.icmic.com
Characteristics subject to change without notice.
3 of 14
X76F400
Figure 3. Definition of Start and Stop Conditions
SCL
SDA
START Condition
STOP Condition
Table 1. X76F400 Instruction Set
Command After Start
Command Description
Password Used
1 S5 S4 S3 S2 S1 S00
Sector Write
Write
1 S5 S4 S3 S2 S1 S0 1
Sector Read
Read
11111100
Change Write Password
Write
11111110
Change Read Password
Write
01010101
Password ACK Command
None
then return to the standby mode. All write/read operations
require a password.
with the nonvolatile write operation, it will issue a “noACK” in response. If the nonvolatile write operation is
completed, an “ACK” will be returned and the host can then
proceed with the rest of the protocol.
PROGRAM OPERATIONS
Data ACK Polling Sequence
Illegal command codes will be disregarded. The part will
respond with a “no-ACK” to the illegal byte and
Sector Write
The sector write mode requires issuing the 8-bit write
command followed by the password and then the data
bytes transferred as illustrated in Figure 4. The write
command byte contains the address of the sector to be
written. Data is written starting at the first address of a
sector and 8 bytes must be transferred. After the last
byte to be transferred is acknowledged, a stop condition is
issued which starts the nonvolatile write cycle. If
more or less than 8 bytes are transferred, the data in the
sector remains unchanged.
ACK Polling
Once a stop condition is issued to indicate the end of the
host’s write sequence, the X76F400 initiates the
internal nonvolatile write cycle. In order to take advantage of
the typical 5ms write cycle, ACK polling can
begin immediately. This involves issuing the start condition
followed by the new command code of 8 bits
Write Sequence
Completed Enter ACK
Polling
Issue START
Issue New
Command Code
ACK
Returned?
NO
YES
PROCEED
(first byte of the protocol). If the X76F400 is still busy
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
4 of 14
X76F400
After the password sequence, there is always a nonvola- tile
write cycle. This is done to discourage random
guesses of the password if the device is being tampered with.
In order to continue the transaction, the X76F400
READ OPERATIONS
Read operations are initiated in the same manner as
write operations but with a different command code.
requires the master to perform a password ACK polling
sequence with the specific command code of 55h. As
Sector Read
with regular acknowledge polling the user can either time
out for 10ms and then issue the ACK polling once,
With sector read, a sector address is supplied with the read
command. Once the password has been
or continuously loop as described in the flow.
acknowledged data may be read from the sector. An
acknowledge must follow each 8-bit data transfer. A
If the password inserted is correct, the nonvolatile cycle
in response to the password ACK polling
read operation always begins at the first byte in the
sector, but may stop at any time. Random accesses to
sequence is over, and an “ACK” is returned.
If the password inserted is incorrect, a “no ACK” is
returned, even if the nonvolatile cycle is over. Therefore, the user cannot be certain that the password is
incorrect until the 10ms write cycle time has elapsed.
the array are not possible. Continuous reading from the
array will return data from successive sectors. After
reading the last sector in the array, the address is automatically set to the first sector in the array and data can
continue to be read out. After the last bit has been read,
a stop condition is generated without sending a
preceding acknowledge.
Password ACK Polling Sequence
Password Load
Completed Enter ACK
Polling
Issue START
Issue Password
ACK Command
ACK
Returned?
NO
YES
PROCEED
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
5 of 14
X76F400
START
Figure 4. Sector Write Sequence (Password Required)
Host
Commands
Write
Password
Write
Command
Write
Password
7
0
Wait tWC OR
Password
ACK
Command
ACK
ACK
ACK
ACK
SDA S
X76F400
Response
STOP
Password ACK
Command
ACK
Host
Commands
ACK
START
If ACK, then
Password Matches
P
Wait tWC Data
ACK Polling
ACK
ACK
X76F400
Response
ACK
No-ACK
ACK
S
Figure 5. Acknowledge Polling
SCL
8th CLK of
8th
Pwd. Byte
SDA
‘ACK’
CLK
8th
CLK
‘ACK’
8th Bit
‘ACK’
CLK
ACK or
No ACK
START
Condition
START
Figure 6. Sector Read Sequence (Password Required)
Host
Commands
Read
Password
7
0
Wait tWC OR
Password
ACK
Command
ACK
ACK
ACK
SDA S
ACK
X76F400
Response
Read
Password
Read
Command
STOP
Password ACK
Command
ACK
Host
Commands
ACK
START
If ACK, then
Password Matches
P
REV 1.0 7/5/00
ACK
X76F400
Response
No-ACK
S
Data 0
www.icmic.com
Data n
Characteristics subject to change without notice.
6 of 14
X76F400
PASSWORDS
Passwords are changed by sending the “change read
password” or “change write password” commands in a
normal sector write operation. A full 8 bytes containing the
new password must be sent, following successful
transmission of the current write password and a valid
password ACK response. The user can use a repeated
ACK polling command to check that a new password
been written correctly. An ACK indicates that the
has
new password is valid.
After initiating a nonvolatile write cycle, the RST pin must
not be pulsed until the nonvolatile write cycle is
complete. If not, the ISO response will not be activated.
If the RST is pulsed HIGH and the CLK is within
the RST pulse (meet the t NOL spec.) in the middle of an
ISO transaction, it will output the 32 bit sequence again
(starting at bit 0). Otherwise, this aborts the ISO
operation and the part returns to standby state. If the RST
is pulsed HIGH and the CLK is outside the RST
pulse (in the middle of an ISO transaction), this aborts the
ISO operation and the part returns to standby
There is no way to read any of the passwords.
state.
RESPONSE-TO-RESET (DEFAULT = 19 40 AA 55)
If power is interrupted during the response-to-reset, the
response-to-reset will be aborted and the part will
The ISO Response-to-reset is controlled by the RST and
CLK pins. When RST is pulsed high during a clock
return to the standby state. A response-to-reset is not
available during a nonvolatile write cycle.
pulse, the device will output 32 bits of data, one bit per
clock, and it resets to the standby state. This conforms
to the ISO standard for “synchronous response to reset.”
The part must not be in a write cycle for the
response-to-reset to occur.
Figure 7. Response to RESET (RST)
RST
SCK
SO
10
0 11
LSB
Byte
REV 1.0 7/5/00
0 00
0 1 0
0 0000
MSB LSB
0
0 1 0 1 0 1 0 1
www.icmic.com
MSB
MSB LSB
MSB LSB
1
1 0 1 0 1 0 1 0
2
3
Characteristics subject to change without notice.
7 of 14
X76F400
ABSOLUTE MAXIMUM RATINGS
COMMENT
Temperature under bias .................... –65°C to +135°C
Storage temperature ........................ –65°C to +150°C
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
Voltage on any pin with
respect to V SS ......................................... –1V to +7V
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
D.C. output current............................................... 5mA
Lead temperature (soldering, 10 seconds).........300°C
listed in the operational sections of this specification) is not
implied. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
0°C
+70°C
X76F400
4.5V to 5.5V
Industrial
–40°C
+85°C
X76F400 – 2.5
2.5V to 5.5V
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
Parameter
ICC1
Min.
VCC Supply current
Max.
Unit
Test Conditions
1
mA
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 kHz,
(Read)
ICC2(3)
SDA = Open
RST = V SS
VCC Supply current
3
mA
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 kHz,
(Write)
ISB1(1)
SDA = Open
RST = V SS
VCC Supply current
1
µA
V IL = VCC x 0.1, VIH = VCC x 0.9
fSCL = 400 kHz, fSDA = 400 kHz
1
µA
V SDA = VSCC = VCC
Other = GND or VCC–0.3V
(Standby)
ISB2(1)
VCC Supply current
(Standby)
ILI
Input leakage current
10
µA
VIN = VSS to VCC
ILO
Output leakage current
10
µA
VOUT = VSS to VCC
VIL(2)
Input LOW voltage
–0.5
VCC x 0.1
V
VIH
Input HIGH voltage
VCC x 0.9
VCC + 0.5
V
0.4
V
(2)
VOL
Output LOW voltage
IOL = 3mA
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
COUT
CIN
(3)
(3)
Test
Max.
Unit
Conditions
Output capacitance (SDA)
8
pF
VI/O = 0V
Input capacitance (RST, SCL)
6
pF
VIN = 0V
Notes: (1)Must perform a stop command after a read command prior to measurement (2)V
IL min. and VIH max. are for reference only and are not tested
(3)This parameter is periodically sampled and not 100% test
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
8 of 14
X76F400
EQUIVALENT A.C. LOAD CIRCUIT
5V
A.C. TEST CONDITIONS
3V
1.53KΟ
1.3KΟ
Output
Output
100pF
Input pulse levels
VCC x 0.1 to VCC x 0.9
Input rise and fall times
10ns
Input and output timing level
VCC x 0.5
Output load
100pF
100pF
AC CHARACTERISTICS (TA = -40°C to +85°C, VCC = +2.5V to +5.5V, unless otherwise specified)
Symbol
Parameter
Min.
Max.
Unit
0
1
MHz
0.9
µs
fSCL
SCL clock frequency
tAA(2)
SCL LOW to SDA data out valid
0.1
tBUF
Time the Bus must be free before a new transmission can start
1.2
µs
Start condition hold time
0.6
µs
tLOW
Clock LOW period
1.2
µs
tHIGH
tHD:STA
Clock HIGH period
0.6
µs
tSU:STA
Start condition setup time (for a repeated start condition)
0.6
µs
tHD:DAT
Data in hold time
10
ns
tSU:DAT
Data in setup time
100
ns
tR
SDA and SCL rise time
20+0.1XCb(1)
300
ns
tF
SDA and SCL fall time
20+0.1XCb
300
ns
tSU:STO
(1)
Stop condition setup time
tDH
Data out hold time
0.6
µs
0
µs
500
ns
tNOL
RST to SCL non-overlap
tRDV
RST LOW to SDA valid during response to reset
0
450
ns
tCDV
CLK LOW to SDA valid during response to reset
0
450
ns
tRST
RST high time
1.5
µs
tSU:RST
RST setup time
500
ns
Notes: (1)Cb = total capacitance of one bus line in pF
(2)tAA = 1.1µs Max below VCC = 2.5V.
RESET AC SPECIFICATIONS
Power Up Timing
Symbol
tPUR
(1)
tPUW
(1)
Parameter
Min.
(2)
Typ.
Max.
Unit
Time from power up to read
1
ms
Time from power up to write
5
ms
Notes: (1)Delays are measured from the time VCC is stable until the specified operation can be initiated. These parameters are periodically sampled
and not 100% tested.
(2)Typical values are for TA = 25°C and VCC = 5.0V
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
9 of 14
X76F400
Nonvolatile Write Cycle Timing
Symbol
Parameter
tWC
Typ.
Write cycle time
(1)
Note:
(1)
Min.
Max.
Unit
10
ms
5
(1)tWC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It is the
minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
Bus Timing
tHIGH
tF
tLOW
tR
SCL
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
SDA IN
tAA
tBUF
tDH
SDA OUT
Write Cycle Timing
SCL
SDA
8th Bit of Last Byte
ACK
tWC
STOP
Condition
START
Condition
RST Timing Diagram—Response to a Synchronous Reset
RST
tRST
tNOL
CLK
nd
1
CLK
2
CLK
Pulse
tRDV
I/O
REV 1.0 7/5/00
tHIGH_RST
tNOL
st
tSU:RST
Pulse
rd
tLOW_RST
3
CLK
Pulse
tCDV
Data Bit (1)
www.icmic.com
Data Bit (2)
Characteristics subject to change without notice.
10 of 14
X76F400
Pull Up Resistance in KΟ
GUIDELINES FOR CALCULATING TYPICAL VALUES OF BUS PULL UP RESISTORS
100
80
MIN
RMAX
40
20
= -------------------------= 1.8KΟ
I
OLMIN
60
t
R
R
MAX
RMIN
= C
-----------------BUS
40
60
80 100
20
Bus Capacitance in pF
REV 1.0 7/5/00
V
CCMAX
R
tR = maximum allowable SDA rise time
www.icmic.com
Characteristics subject to change without notice.
11 of 14
X76F400
PACKAGING INFORMATION
8-Lead Plastic Small Outline Gull Wing Package Type S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
Pin 1 Index
Pin 1
0.014 (0.35)
0.019 (0.49)
0.188 (4.78)
0.197 (5.00)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.050" Typical
0.010 (0.25) X 45°
0.020 (0.50)
0.050"
Typical
0° - 8°
0.0075 (0.19)
0.010 (0.25)
0.250"
0.016 (0.410)
0.037 (0.937)
0.030"
Typical
FOOTPRINT
8 Places
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
12 of 14
X76F400
PACKAGING INFORMATION
8-Lead Plastic, TSSOP, Package Type V
.025 (.65) BSC
.169
.252 (6.4) BSC
(4.3) .177
(4.5)
.114
(2.9) .122
(3.1)
.047 (1.20)
.002
(.05) .006
(.15)
.0075
(.19) .0118
(.30)
.010 (.25)
Gage Plane
0° – 8°
Seating Plane
.019
(.50) .029
(.75)
(4.16) (7.72)
Detail A (20X)
(1.78)
.031
(.80) .041
(1.05)
(0.42)
(0.65)
All Measurements Are Typical
See Detail “A”
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
13 of 14
X76F400
Ordering Information
X76F400
P
T
G –V
Device
VCC Limits
Blank = 5V ±10%
2.5 = 2.5V to 5.5V
RoHS Compliant Lead Free package
Blank – Standard package. Non lead free
Temperature Range
Blank = Commercial = 0°C to +70°C
I = Industrial= –40°C to +85°C
Package
S8 = 8-Lead SOIC
V8 = 8-Lead TSSOP
H = Die in waffle packs (Contact Factory)
W = Die in wafer form (Contact Factory)
Part Mark Convention
8-Lead SOIC
X76F400 XG
XX
8-Lead TSSOP
Blank = 8-Lead SOIC
G = RoHS compliant lead free
YWW
7640XX
Blank = 4.5 to 5.5V, 0 to 70°C
I = 4.5 to 5.5V, -40 to +85°C
AE = 2.5 to 5.5V, 0 to 70°C
AF = 2.5 to 5.5V, -40 to +85°C
AE = 2.5 to 5.5V, 0 to +70°C
AF = 2.5 to 5.5V, -40 to +85°C
Blank = 4.5 to 5.5V, 0 to +70°C
I = 4.5 to 5.5V, -40 to +85°C
©Xicor, Inc. 2000 Patents Pending
LIMITED WARRANTY
Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty, express, statutory,
implied, or by description regarding the information set forth herein or regarding the freedom of the described devices from patent infringement. Xicor, Inc. makes no warranty of
merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice.
Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, or licenses are implied.
TRADEMARK DISCLAIMER:
Xicor and the Xicor logo are registered trademarks of Xicor, Inc. AutoStore, Direct Write, Block Lock, SerialFlash, MPS, and XDCP are also trademarks of Xicor, Inc. All others
belong to their respective owners.
U.S. PATENTS
Xicor products are covered by one or more of the following U.S. Patents: 4,326,134; 4,393,481; 4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706;
4,617,652; 4,668,932; 4,752,912; 4,829,482; 4,874,967; 4,883,976; 4,980,859; 5,012,132; 5,003,197; 5,023,694; 5,084,667; 5,153,880; 5,153,691; 5,161,137; 5,219,774;
5,270,927; 5,324,676; 5,434,396; 5,544,103; 5,587,573; 5,835,409; 5,977,585. Foreign patents and additional patents pending.
LIFE RELATED POLICY
In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection and
correction, redundancy and back-up features to prevent such an occurrence.
Xicor’s products are not authorized for use in critical components in life support devices or systems.
1.Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to
perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2.A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or effectiveness.
REV 1.0 7/5/00
www.icmic.com
Characteristics subject to change without notice.
14 of 14