ZARLINK ZL30101

ZL30101
T1/E1 Stratum 3 System Synchronizer
Data Sheet
Features
October 2004
•
Supports Telcordia GR-1244-CORE Stratum 3
•
Supports G.823 and G.824 for 2048 kbit/s and
1544 kbit/s interfaces
•
Ordering Information
ZL30101QDC
Supports ANSI T1.403 and ETSI ETS 300 011 for
ISDN primary rate interfaces
-40°C to +85°C
•
Simple hardware control interface
•
Accepts two input references and synchronizes to
any combination of 8 kHz, 1.544 MHz, 2.048 MHz,
8.192 MHz or 16.384 MHz inputs
•
Applications
Provides a range of clock outputs: 1.544 MHz,
2.048 MHz, 16.384 MHz and either 4.096 MHz &
8.192 MHz or 32.768 MHz & 65.536 MHz
•
Provides 5 styles of 8 kHz framing pulses
•
Holdover frequency accuracy of 1 x 10-8
•
Lock, Holdover and Out of Range indication
•
Selectable loop filter bandwidth of 1.8 Hz or 922 Hz
•
Less than 0.6 nspp jitter on all output clocks
•
External master clock source: clock oscillator or
crystal
OSCi OSCo
64 pin TQFP
•
Synchronization and timing control for multi-trunk
DS1/E1 systems such as DSLAMs, gateways and
PBXs
•
Clock and frame pulse source for ST-BUS, GCI
and other time division multiplex (TDM) buses
TIE_CLR
BW_SEL
LOCK
OUT_SEL
Master Clock
REF0
REF1
REF_FAIL0
REF_FAIL1
TIE
Corrector
Circuit
MUX
Reference
Monitor
TIE
Corrector
Enable
C2o
C4/C65o
C8/C32o
C16o
F4/F65o
F8/F32o
Virtual
Reference
DPLL
F16o
Mode
Control
Feedback
REF_SEL
State Machine
E1
Synthesizer
DS1
Synthesizer
C1.5o
Frequency
Select
MUX
RST
IEEE
1149.1a
MODE_SEL1:0
HMS
HOLDOVER
TCK TDI
TMS TDO
Figure 1 - Functional Block Diagram
1
Zarlink Semiconductor Inc.
Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc.
Copyright 2004, Zarlink Semiconductor Inc. All Rights Reserved.
TRST
ZL30101
Data Sheet
Description
The ZL30101 Stratum 3 System Synchronizer contains a digital phase-locked loop (DPLL), which provides
timing and synchronization for multi-trunk T1 and E1 transmission equipment.
The ZL30101 generates ST-BUS and other TDM clock and framing signals that are phase locked to one of two
input references. It helps ensure system reliability by monitoring its references for accuracy and stability and by
maintaining stable output clocks during reference switching operations and during short periods when a
reference is unavailable.
The ZL30101 is intended to be the central timing and synchronization resource for network equipment that
complies with Telcordia, ETSI, ITU-T and ANSI network specifications.
2
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
Table of Contents
1.0 Change Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.0 Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Pin Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.0 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1 Reference Select Multiplexer (MUX) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.2 Reference Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.3 Time Interval Error (TIE) Corrector Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.4 Digital Phase Lock Loop (DPLL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.5 Frequency Synthesizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.6 State Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.7 Master Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.0 Control and Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1 Loop Filter Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2 Output Clock and Frame Pulse Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.3 Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.3.1 Freerun Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.3.2 Holdover Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.3.3 Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.4 Reference Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.0 Measures of Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.1 Jitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.2 Jitter Generation (Intrinsic Jitter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.3 Jitter Tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.4 Jitter Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.5 Frequency Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.6 Holdover Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.7 Pull-in Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.8 Lock Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.9 Phase Slope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.10 Time Interval Error (TIE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.11 Maximum Time Interval Error (MTIE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.12 Phase Continuity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.13 Lock Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.0 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.1 Power Supply Decoupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.2 Master Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.2.1 Clock Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.2.2 Crystal Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.3 Power Up Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.4 Reset Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.0 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.1 AC and DC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.2 Performance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
List of Figures
Figure 1 - Functional Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Figure 2 - Pin Connections (64 pin TQFP, please see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 3 - Reference Monitor Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 4 - Behaviour of the Dis/Requalify Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 5 - Out-of-Range Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 6 - Timing Diagram of Hitless Reference Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 7 - Timing Diagram of Hitless Mode Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 8 - DPLL Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 9 - Mode Switching in Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 10 - Reference Switching in Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 11 - Recommended Power Supply Decoupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 12 - Clock Oscillator Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 13 - Crystal Oscillator Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 14 - Power-Up Reset Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 15 - Timing Parameter Measurement Voltage Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 16 - Input to Output Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 17 - Output Timing Referenced to F8/F32o . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4
Zarlink Semiconductor Inc.
ZL30101
1.0
Data Sheet
Change Summary
Changes from June 2004 Issue to October 2004 Issue. Page, section, figure and table numbers refer to this issue.
Page
Item
Change
1
Text
Jitter changed to 0.6 ns from 0.5 ns
6
Figure 2
Added note specifying not e-Pad
7
Table “Pin Description“
Added information about Schmitt trigger feedback paths to
C1.5o, C2o, C16o, and F8/F32o
10
Section 3.2
Added text about input pulse width restriction
15
Section 3.4
Added details on LOCK pin behaviour
19
Section 4.4
Added text and Figure 10 explaining LOCK pin behaviour
20
Section 5.0
Added Jitter definition
25
Section 6.4
Corrected time-constant of example reset circuit
26
Table “Absolute Maximum Ratings*“
Corrected package power rating
27
Table “DC Electrical Characteristics*“
Corrected current consumption
Corrected input voltage characteristics to reflect Schmitt trigger
Corrected input leakage current to reflect internal pull-ups
Corrected output voltage note to reflect two pad strengths
28
Table “AC Electrical Characteristics* Input Timing for REF0 and REF1
References (see Figure 16)“
Added explanatory note
32
Table “Performance Characteristics*:
Output Jitter Generation - ANSI
T1.403 Conformance“
Changed jitter numbers
32
Table “Performance Characteristics*:
Output Jitter Generation - ITU-T
G.812 Conformance“
Changed jitter number
32
Table “Performance Characteristics* Unfiltered Intrinsic Jitter“
Changed jitter numbers, removed UI column
5
Zarlink Semiconductor Inc.
ZL30101
Physical Description
2.1
Pin Connections
F8/F32o
C16o
C2o
AVDD
AVDD
C8/C32o
C4/C65o
AGND
AGND
NC
NC
AVDD
AVDD
AVCORE
AGND
AGND
2.0
Data Sheet
48
46
44
42
40
38
36
34
32
50
30
52
28
54
26
ZL30101
56
24
58
22
60
20
62
18
64
2
4
6
8
10
12
14
C1.5o
NC
NC
AVDD
IC
IC
OUT_SEL
VDD
NC
GND
IC
OSCi
OSCo
RST
MODE_SEL1
MODE_SEL0
16
GND
VCORE
LOCK
HOLDOVER
REF_FAIL0
IC
REF_FAIL1
TDO
TMS
TRST
TCK
VCORE
GND
AVCORE
TDI
HMS
F4/F65o
F16o
AGND
IC
REF_SEL
NC
REF0
NC
REF1
NC
IC
IC
VDD
NC
TIE_CLR
BW_SEL
Figure 2 - Pin Connections (64 pin TQFP, please see Note 1)
Note 1: The ZL30101 uses the TQFP shown in the package outline designated with the suffix QD, the ZL30101
does not use the e-Pad TQFP.
6
Zarlink Semiconductor Inc.
ZL30101
2.2
Data Sheet
Pin Description
Pin Description
Pin #
Name
Description
1
GND
2
VCORE
Positive Supply Voltage. +1.8 VDC nominal.
3
LOCK
Lock Indicator (Output). This output goes to a logic high when the PLL is frequency
locked to the selected input reference.
4
HOLDOVER
Holdover (Output). This output goes to a logic high whenever the PLL goes into
holdover mode.
5
REF_FAIL0
Reference 0 Failure Indicator (Output). A logic high at this pin indicates that the REF0
reference frequency has exceeded the out-of-range limit or that it is exhibiting abrupt
phase or frequency changes.
6
IC
7
REF_FAIL1
Reference 1 Failure Indicator (Output). A logic high at this pin indicates that the REF1
reference frequency has exceeded the out-of-range limit or that it is exhibiting abrupt
phase or frequency changes.
8
TDO
Test Serial Data Out (Output). JTAG serial data is output on this pin on the falling edge
of TCK. This pin is held in high impedance state when JTAG scan is not enabled.
9
TMS
Test Mode Select (Input). JTAG signal that controls the state transitions of the TAP
controller. This pin is internally pulled up to VDD. If this pin is not used then it should be
left unconnected.
10
TRST
Test Reset (Input). Asynchronously initializes the JTAG TAP controller by putting it in
the Test-Logic-Reset state. This pin should be pulsed low on power-up to ensure that
the device is in the normal functional state. This pin is internally pulled up to VDD. If
this pin is not used then it should be connected to GND.
11
TCK
Test Clock (Input): Provides the clock to the JTAG test logic. If this pin is not used then it
should be pulled down to GND.
12
VCORE
13
GND
14
AVCORE
15
TDI
16
HMS
Ground. 0 V.
Internal bonding Connection. Leave unconnected.
Positive Supply Voltage. +1.8 VDC nominal.
Ground. 0 V.
Positive Analog Supply Voltage. +1.8 VDC nominal.
Test Serial Data In (Input). JTAG serial test instructions and data are shifted in on this
pin. This pin is internally pulled up to VDD. If this pin is not used then it should be left
unconnected.
Hitless Mode Switching (Input). The HMS circuit controls phase accumulation during
the transition from Holdover or Freerun mode to Normal mode on the same reference. A
logic low at this pin will cause the ZL30101 to maintain the delay stored in the TIE
Corrector Circuit when it transitions from Holdover or Freerun mode to Normal mode. A
logic high on this pin will cause the ZL30101 to measure a new delay for its TIE Corrector
Circuit thereby minimizing the output phase movement when it transitions from Holdover
or Freerun mode to Normal mode.
17
MODE_SEL0 Mode Select 0 (Input). This input combined with MODE_SEL1 determines the mode
(Normal, Holdover or Freerun) of operation, see Table 3 on page 17.
18
MODE_SEL1 Mode Select 1 (Input). See MODE_SEL0 pin description.
7
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
Pin Description (continued)
Pin #
Name
Description
19
RST
Reset (Input). A logic low at this input resets the device. On power up, the RST pin
must be held low for a minimum of 300 ns after the power supply pins have reached
the minimum supply voltage. When the RST pin goes high, the device will transition
into a Reset state for 3 ms. In the Reset state all outputs will be forced into high
impedance.
20
OSCo
Oscillator Master Clock (Output). For crystal operation, a 20 MHz crystal is connected
from this pin to OSCi. This output is not suitable for driving other devices. For clock
oscillator operation, this pin must be left unconnected.
21
OSCi
Oscillator Master Clock (Input). For crystal operation, a 20 MHz crystal is connected
from this pin to OSCo. For clock oscillator operation, this pin must be connected to a
clock source.
22
IC
23
GND
24
NC
No internal bonding Connection. Leave unconnected.
25
VDD
Positive Supply Voltage. +3.3 VDC nominal.
26
OUT_SEL
27
IC
Internal Connection. Connect this pin to ground.
28
IC
Internal Connection. Connect this pin to ground.
29
AVDD
30
NC
No internal bonding Connection. Leave unconnected.
31
NC
No internal bonding Connection. Leave unconnected.
32
C1.5o
Internal Connection. Leave unconnected.
Ground. 0 V.
Output Selection (Input). This input selects the signals on the combined output clock
and frame pulse pins, see Table 2 on page 17.
Positive Analog Supply Voltage. +3.3 VDC nominal.
Clock 1.544 MHz (Output). This output is used in DS1 applications.
This clock output pad includes a Schmitt input which serves as a PLL feedback path;
proper transmission-line termination should be applied to maintain reflections below
Schmitt trigger levels.
33
AGND
Analog Ground. 0 V
34
AGND
Analog Ground. 0 V
35
AVCORE
Positive Analog Supply Voltage. +1.8 VDC nominal.
36
AVDD
Positive Analog Supply Voltage. +3.3 VDC nominal.
37
AVDD
Positive Analog Supply Voltage. +3.3 VDC nominal.
38
NC
No internal bonding Connection. Leave unconnected.
39
NC
No internal bonding Connection. Leave unconnected.
40
AGND
Analog Ground. 0 V
41
AGND
Analog Ground. 0 V
42
C4/C65o
Clock 4.096 MHz or 65.536 MHz (Output). This output is used for ST-BUS operation at
2.048 Mbps, 4.096 Mbps or 65.536 MHz (ST-BUS 65.536 Mbps). The output frequency is
selected via the OUT_SEL pin.
8
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
Pin Description (continued)
Pin #
Name
Description
43
C8/C32o
Clock 8.192 MHz or 32.768 MHz (Output). This output is used for ST-BUS and GCI
operation at 8.192 Mbps or for operation with a 32.768 MHz clock. The output frequency
is selected via the OUT_SEL pin.
44
AVDD
Positive Analog Supply Voltage. +3.3 VDC nominal.
45
AVDD
Positive Analog Supply Voltage. +3.3 VDC nominal.
46
C2o
Clock 2.048 MHz (Output). This output is used for standard E1 interface timing and for
ST-BUS operation at 2.048 Mbps.
This clock output pad includes a Schmitt input which serves as a PLL feedback path;
proper transmission-line termination should be applied to maintain reflections below
Schmitt trigger levels.
47
C16o
Clock 16.384 MHz (Output). This output is used for ST-BUS operation with a
16.384 MHz clock.
This clock output pad includes a Schmitt input which serves as a PLL feedback path;
proper transmission-line termination should be applied to maintain reflections below
Schmitt trigger levels.
48
F8/F32o
Frame Pulse (Output). This is an 8 kHz 122 ns active high framing pulse (OUT_SEL=0)
or it is an 8 kHz 31 ns active high framing pulse (OUT_SEL=1), which marks the
beginning of a frame.
This clock output pad includes a Schmitt input which serves as a PLL feedback path;
proper transmission-line termination should be applied to maintain reflections below
Schmitt trigger levels.
49
F4/F65o
50
F16o
51
AGND
52
IC
53
REF_SEL
54
NC
55
REF0
56
NC
57
REF1
58
NC
Frame Pulse ST-BUS 2.048 Mbps or ST-BUS at 65.536 MHz clock (Output). This
output is an 8 kHz 244 ns active low framing pulse (OUT_SEL=0), which marks the
beginning of an ST-BUS frame. This is typically used for ST-BUS operation at
2.048 Mbps and 4.096 Mbps. Or this output is an 8 kHz 15 ns active low framing pulse
(OUT_SEL=1), typically used for ST-BUS operation with a clock rate of 65.536 MHz.
Frame Pulse ST-BUS 8.192 Mbps (Output). This is an 8 kHz 61 ns active low framing
pulse, which marks the beginning of an ST-BUS frame. This is typically used for ST-BUS
operation at 8.192 Mbps.
Analog Ground. 0 V
Internal Connection. Connect this pin to ground.
Reference Select (Input). This input selects the input reference that is used for
synchronization, see Table 4 on page 19. This pin is internally pulled down to GND.
No internal bonding Connection. Leave unconnected.
Reference (Input). This is one of two (REF0, REF1) input reference sources used for
synchronization. One of five possible frequencies may be used: 8 kHz, 1.544 MHz,
2.048 MHz, 8.192 MHz or 16.384 MHz. This pin is internally pulled down to GND.
No internal bonding Connection. Leave unconnected.
Reference (Input). See REF0 pin description.
No internal bonding Connection. Leave unconnected.
9
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
Pin Description (continued)
Pin #
Name
59
IC
Internal Connection. Connect this pin to ground.
60
IC
Internal Connection. Connect this pin to ground.
61
VDD
Positive Supply Voltage. +3.3 VDC nominal.
62
NC
No internal bonding Connection. Leave unconnected.
63
TIE_CLR
TIE Corrector Circuit Reset (Input). A logic low at this input resets the Time Interval
Error (TIE) correction circuit resulting in a realignment of the input phase with the output
phase.
64
BW_SEL
Filter Bandwidth Selection (Input). This pin selects the bandwidth of the DPLL loop
filter, see Table 1 on page 17. Set continuously high to track jitter on the input reference
closely or temporarily high to allow the ZL30101 to quickly lock to the input reference.
3.0
Description
Functional Description
The ZL30101 is a DS1/E1 Stratum 3 System Synchronizer providing timing (clock) and synchronization (frame)
signals to interface circuits for DS1 and E1 Primary Rate Digital Transmission links. Figure 1 is a functional block
diagram which is described in the following sections.
3.1
Reference Select Multiplexer (MUX)
The ZL30101 accepts two simultaneous reference input signals and operates on their rising edges. One of them,
the primary reference (REF0) or the secondary reference (REF1) signal can be selected as input to the TIE
corrector circuit based on the reference selection (REF_SEL) input.
3.2
Reference Monitor
The input references are monitored by two independent reference monitor blocks, one for each reference. The
block diagram of a single reference monitor is shown in Figure 3. For each reference clock, the frequency is
detected and the clock is continuously monitored for three independent criteria that indicate abnormal behavior of
the reference signal, for example; long term drift from its nominal frequency or excessive jitter. To ensure proper
operation of the reference monitor circuit, the minimum input pulse width restriction of 15 nsec must be
observed.
•
Reference Frequency Detector (RFD): This detector determines whether the frequency of the reference
clock is 8 kHz, 1.544 MHz, 2.048 MHz, 8.192 MHz or 16.384 MHz and provides this information to the
various monitor circuits and the phase detector circuit of the DPLL.
•
Precise Frequency Monitor (PFM): This circuit determines whether the frequency of the reference clock
is within the applicable accuracy range of ±12 ppm, see Figure 5. It will take the precise frequency monitor
up to 10 s to qualify or disqualify the input reference.
•
Coarse Frequency Monitor (CFM): This circuit monitors the reference frequency over intervals of
approximately 30 µs to quickly detect large frequency changes.
•
Single Cycle Monitor (SCM): This detector checks the period of a single clock cycle to detect large
phase hits or the complete loss of the clock.
10
Zarlink Semiconductor Inc.
ZL30101
REF_FAIL0 /
REF_FAIL1
OR
Reference Frequency
Detector
REF0 /
REF1
Data Sheet
Precise Frequency
Monitor
Coarse Frequency
Monitor
Single Cycle
Monitor
dis/requalify
timer
REF_DIS Mode select
state machine
OR
HOLDOVER
REF_DIS= reference disrupted.
This is an internal signal.
Figure 3 - Reference Monitor Circuit
Exceeding the thresholds of any of the monitors forces the corresponding REF_FAIL pin to go high. The single
cycle and coarse frequency failure flags force the DPLL into Holdover mode and feed a timer that disqualifies the
reference input signal when the failures are present for more than 2.5 s. The single cycle and coarse frequency
failures must be absent for 10 s to let the timer requalify the input reference signal as valid. Multiple failures of less
than 2.5 s each have an accumulative effect and will disqualify the reference eventually. This is illustrated in Figure
4.
SCM or CFM failure
current REF
timer
2.5 s
10 s
REF_FAIL
HOLDOVER
Figure 4 - Behaviour of the Dis/Requalify Timer
When the incoming signal returns to normal (REF_FAIL=0), the DPLL returns to Normal mode with the output
signal locked to the input signal. Each of the monitors has a build-in hysteresis to prevent flickering of the
REF_FAIL status pin at the threshold boundaries. The precise frequency monitor and the timer do not affect the
mode (Holdover/Normal) of the DPLL.
11
Zarlink Semiconductor Inc.
ZL30101
C20 Clock Accuracy
Data Sheet
Out of Range
C20
0 ppm
In Range
-12 -9.2
0
9.2 12
Out of Range
C20
+4.6 ppm
In Range
-7.4 -4.6
13.8 16.6
4.6
Out of Range
C20
-4.6 ppm
-16.6 -13.8
-15
-4.6
-10
-5
4.6
0
5
In Range
7.4
10
15
Frequency offset [ppm]
C20: 20 MHz master clock on OSCi
Figure 5 - Out-of-Range Thresholds
The precise frequency monitor’s failure thresholds are compatible with Telcordia GR-1244-CORE Stratum 3 as
shown in Figure 5. It will take the precise frequency monitor up to 10 s to qualify or disqualify the input reference.
3.3
Time Interval Error (TIE) Corrector Circuit
The TIE corrector circuit eliminates phase transients on the output clock that may occur during reference switching
or the recovery from Holdover mode to Normal mode.
On recovery from Holdover mode (dependent on the HMS pin) or when switching to another reference input, the
TIE corrector circuit measures the phase delay between the current phase (feedback signal) and the phase of the
selected reference signal. This delay value is stored in the TIE corrector circuit. This circuit creates a new virtual
reference signal that is at the same phase position as the feedback signal. By using the virtual reference, the PLL
minimizes the phase transient it experiences when it switches to another reference input or recovers from Holdover
mode.
The delay value can be reset by applying a logic low pulse to the TIE corrector circuit clear pin (TIE_CLR). A
minimum reset pulse width is 20 ns. This results in a phase alignment between the input reference signal and the
output clocks and frame pulses as shown in Figure 16 on page 28 and Figure 17 on page 30. The speed of the
phase alignment correction is limited to 61 µs/s when BW_SEL=0. Convergence is always in the direction of least
phase travel. In general the TIE correction should not be exercised when Holdover mode is entered for short time
periods. TIE_CLR can be kept low continuously. In that case the output clocks will always be aligned with the
selected input reference. This is illustrated in Figure 6.
12
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
TIE_CLR = 1
TIE_CLR = 0
locked to REF0
locked to REF0
REF0
REF0
REF1
REF1
Output
Clock
Output
Clock
locked to REF1
locked to REF1
REF0
REF0
REF1
REF1
Output
Clock
Output
Clock
Figure 6 - Timing Diagram of Hitless Reference Switching
The Hitless Mode Switching (HMS) pin enables phase hitless returns from Freerun and Holdover modes to Normal
mode in a single reference operation. A logic low at the HMS input disables the TIE corrector circuit updating the
delay value thereby forcing the output of the PLL to gradually move back to the original point before it went into
Holdover mode. (see Figure 7). This prevents accumulation of phase in network elements. A logic high (HMS=1)
enables the TIE corrector circuit to update its delay value thereby preventing a large output phase movement after
return to Normal mode. This causes accumulation of phase in network elements. In both cases the PLL’s output
can be aligned with the input reference by setting TIE_CLR low. Regardless of the HMS pin state, reference
switching in the ZL30101 is always hitless unless TIE_CLR is kept low continuously.
13
Zarlink Semiconductor Inc.
ZL30101
HMS = 0
Data Sheet
HMS = 1
Normal mode
Normal mode
REF
REF
Output
Clock
Output
Clock
Phase drift in Holdover mode
Phase drift in Holdover mode
REF
REF
Output
Clock
Output
Clock
Return to Normal mode
Return to Normal mode
REF
REF
Output
Clock
Output
Clock
TIE_CLR=0
TIE_CLR=0
REF
REF
Output
Clock
Output
Clock
Figure 7 - Timing Diagram of Hitless Mode Switching
Examples:
HMS=1: When 10 Normal to Holdover to Normal mode transitions occur and in each case the Holdover mode was
entered for 2 seconds, then the accumulated phase change (MTIE) could be as large as 330 ns.
-
Phaseholdover_drift = 0.01 ppm x 2 s = 20 ns
-
Phasemode_change = 0 ns + 13 ns = 13 ns
-
Phase10 changes = 10 x (20 ns + 13 ns) = 330 ns
where:
-
0.01 ppm is the accuracy of the Holdover mode
-
0 ns is the maximum phase discontinuity in the transition from the Normal mode to the Holdover mode
14
Zarlink Semiconductor Inc.
ZL30101
-
Data Sheet
13 ns is the maximum phase discontinuity in the transition from the Holdover mode to the Normal mode
when a new TIE corrector value is calculated
HMS=0: When the same ten Normal to Holdover to Normal mode changes occur and in each case Holdover mode
was entered for 2 seconds, then the overall MTIE would be 20 ns. As the delay value for the TIE corrector circuit is
not updated, there is no 13 ns measurement error at this point. The phase can still drift for 20 ns when the PLL is in
Holdover mode but when the PLL enters Normal mode again, the phase moves back to the original point so the
phase is not accumulated.
3.4
Digital Phase Lock Loop (DPLL)
The DPLL of the ZL30101 consists of a phase detector, a limiter, a loop filter, a digitally controlled oscillator (DCO)
and a lock indicator, as shown in Figure 8. The data path from the phase detector to the limiter is tapped and routed
to the lock indicator that provides a lock indication which is output at the LOCK pin.
Lock
indicator
Virtual Reference
from
TIE Corrector Circuit
Phase
Detector
Limiter
Loop Filter
Digitally
Controlled
Oscillator
LOCK
DPLL Reference to
Frequency Synthesizer
State Select from
Control State Machine
Feedback signal from
Frequency Select MUX
Figure 8 - DPLL Block Diagram
Phase Detector - the phase detector compares the virtual reference signal from the TIE corrector circuit with the
feedback signal and provides an error signal corresponding to the phase difference between the two. This error
signal is passed to the limiter circuit.
Limiter - the limiter receives the error signal from the phase detector and ensures that the DPLL responds to all
input transient conditions with a maximum output phase slope of 61 µs/s or 9.5 ms/s, see Table 1.
Loop Filter - the loop filter is similar to a first order low pass filter with a narrow or wide bandwidth suitable to
provide system synchronization or line card timing, see Table 1. The wide bandwidth can be used to closely track
the input reference in the presence of jitter or it can be temporarily enabled for fast locking to a new reference (1 s
lock time).
Digitally Controlled Oscillator (DCO) - the DCO receives the limited and filtered signal from the loop filter, and
based on its value, generates a corresponding digital output signal. The synchronization method of the DCO is
dependent on the state of the ZL30101.
15
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
In Normal mode, the DCO provides an output signal which is frequency and phase locked to the selected input
reference signal.
In Holdover mode, the DCO is free running at a frequency equal to the frequency that the DCO was generating in
Normal mode. The frequency in Holdover mode is calculated from frequency samples stored 26 ms to 52 ms before
the ZL30101 entered Holdover mode.
In Freerun mode, the DCO is free running with an accuracy equal to the accuracy of the OSCi 20 MHz source.
Lock Indicator - the lock detector monitors if the output value of the phase detector is within the
phase-lock-window for a certain time. The selected phase-lock-window guarantees the stable operation of the
LOCK pin with maximum network jitter and wander on the reference input. If the DPLL is locked and then goes into
Holdover mode (auto or manual), the LOCK pin will initially stay high for 1 s. If at that point the DPLL is still in
holdover mode, the LOCK pin will go low; subsequently the LOCK pin will not return high for at least the full
lock-time duration. In Freerun mode the LOCK pin will go low immediately.
3.5
Frequency Synthesizers
The output of the DCO is used by the frequency synthesizers to generate the C1.5o, C2o, C4o, C8o, C16o, C32o
and C65o clocks and the F4o, F8o, F16o, F32o and F65o frame pulses which are synchronized to the selected
reference input (REF0 or REF1). The frequency synthesizers use digital techniques to generate output clocks and
advanced noise shaping techniques to minimize the output jitter. The clock and frame pulse outputs have limited
driving capability and should be buffered when driving high capacitance loads.
3.6
State Machine
As shown in Figure 1, the control state machine controls the TIE Corrector Circuit and the DPLL. The control of the
ZL30101 is based on the inputs MODE_SEL1:0, REF_SEL and HMS.
3.7
Master Clock
The ZL30101 can use either a clock or crystal as the master timing source. For recommended master timing
circuits, see the Applications - Master Clock section.
16
Zarlink Semiconductor Inc.
ZL30101
4.0
Control and Modes of Operation
4.1
Loop Filter Selection
Data Sheet
The loop filter settings can be selected through the BW_SEL pin, see Table 1. For the ZL30101 to be compliant with
Telcordia GR-1244-CORE Stratum 3, BW_SEL must be set low.
BW_SEL
Detected REF Frequency
Loop Filter Bandwidth
Phase Slope Limiting
0
any
1.8 Hz
61 µs/s
1
8 kHz
58 Hz
9.5 ms /s
1
1.544 MHz, 2.048 MHz,
8.192 MHz, 16.384 MHz
922 Hz
9.5 ms /s
Table 1 - Loop Filter Settings
4.2
Output Clock and Frame Pulse Selection
The output clock and frame pulses of the frequency synthesizers are available in two groups controlled by the
OUT_SEL input. Table 2 lists the supported combinations of output clocks and frame pulses.
OUT_SEL
Generated Clocks
Generated Frame Pulses
0
C1.5o, C2o, C4o, C8o, C16o
F4o, F8o, F16o
1
C1.5o, C2o, C16o, C32o, C65o
F16o, F32o, F65o
Table 2 - Clock and Frame Pulse Selection
4.3
Modes of Operation
The ZL30101 has three possible manual modes of operation; Normal, Holdover and Freerun. These modes are
selected with the mode select pins MODE_SEL1 and MODE_SEL0 as is shown in Table 3. Transitioning from one
mode to the other is controlled by an external controller.
MODE_SEL1
MODE_SEL0
Mode
0
0
Normal (with automatic Holdover)
0
1
Holdover
1
0
Freerun
1
1
reserved (must not be used)
Table 3 - Operating Modes
4.3.1
Freerun Mode
Freerun mode is typically used when an independent clock source is required, or immediately following system
power-up before network synchronization is achieved.
In Freerun mode, the ZL30101 provides timing and synchronization signals which are based on the master clock
frequency (supplied to OSCi pin) only, and are not synchronized to the reference input signals.
17
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
The Freerun accuracy of the output clock is equal to the accuracy of the master clock (OSCi). So if a ±4.6 ppm
output clock is required, the master clock must also be ±4.6 ppm. See Applications - Section 6.2, “Master Clock“.
4.3.2
Holdover Mode
Holdover mode is typically used for short durations while network synchronization is temporarily disrupted.
In Holdover mode, the ZL30101 provides timing and synchronization signals, which are not locked to an external
reference signal, but are based on storage techniques. The storage value is determined while the device is in
Normal Mode and locked to an external reference signal.
When in Normal mode, and locked to the input reference signal, a numerical value corresponding to the ZL30101
output reference frequency is stored alternately in two memory locations every 26 ms. When the device is switched
into Holdover mode, the value in memory from between 26 ms and 52 ms is used to set the output frequency of the
device. The frequency accuracy of Holdover mode is 0.01 ppm.
Two factors affect the accuracy of Holdover mode. One is drift on the master clock while in Holdover mode, drift on
the master clock directly affects the Holdover mode accuracy. Note that the absolute master clock (OSCi) accuracy
does not affect Holdover accuracy, only the change in OSCi accuracy while in Holdover mode. For example, a
±4.6 ppm master clock may have a temperature coefficient of ±0.1 ppm per °C. So a ±10 °C change in
temperature, while the ZL30101 is in Holdover mode may result in an additional offset (over the 0.01 ppm) in
frequency accuracy of ±1 ppm. Which is much greater than the 0.01 ppm of the ZL30101. The other factor affecting
the accuracy is large jitter on the reference input prior to the mode switch.
4.3.3
Normal Mode
Normal mode is typically used when a system clock source, synchronized to the network is required. In Normal
mode, the ZL30101 provides timing (C1.5o, C2o, C4o, C8o, C16o, C32o and C65o) and frame synchronization
(F4o, F8o, F16o, F32o and F65o) signals, which are synchronized to one of two reference inputs (REF0 or REF1).
The input reference signal may have a nominal frequency of 8 kHz, 1.544 MHz, 2.048 MHz, 8.192 MHz or
16.384 MHz. The frequency of the reference inputs are automatically detected by the reference monitors.
When the ZL30101 comes out of RESET while Normal mode is selected by its MODE_SEL pins then it will initially
go into Holdover mode and generate clocks with the accuracy of its free running local oscillator (see Figure 9). If the
ZL30101 determines that its selected reference is disrupted (see Figure 3), it will remain in Holdover until the
selected reference is no longer disrupted or the external controller selects another reference that is not disrupted. If
the ZL30101 determines that its selected reference is not disrupted (see Figure 3) then the state machine will cause
the DPLL to recover from Holdover via one of two paths depending on the logic level at the HMS pin. If HMS=0 then
the ZL30101 will transition directly to Normal mode and it will align its output signals with its selected input
reference (see Figure 7). If HMS=1 then the ZL30101 will transition to Normal mode via the TIE correction state and
the phase difference between the output signals and the selected input reference will be maintained.
When the ZL30101 is operating in Normal mode, if it determines that its selected reference is disrupted (Figure 3)
then its state machine will cause it to automatically go to Holdover mode. When the ZL30101 determines that its
selected reference is not disrupted then the state machine will cause the DPLL to recover from Holdover via one of
two paths depending on the logic level at the HMS pin (see Figure 9). If HMS=0 then the ZL30101 will transition
directly to Normal mode and it will align its output signals with its input reference (see Figure 7). If HMS=1 then the
ZL30101 will transition to Normal mode via the TIE correction state and the phase difference between the output
signals and the input reference will be maintained.
If the reference selection changes because the value of the REF_SEL1:0 pins changes, the ZL30101 goes into
Holdover mode and returns to Normal mode through the TIE correction state regardless of the logic value on HMS
pin.
The ZL30101 provides a wide bandwidth loop filter setting (BW_SEL=1), which enables the PLL to lock to an
incoming reference in approximately 1 s.
18
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
Normal
(HOLDOVER=0)
RST
REF_CH=1
REF_DIS=0 and
REF_CH=0 and
HMS=0
REF_DIS=0
REF_DIS=1
REF_DIS=1
TIE Correction
(HOLDOVER=1)
Holdover
(HOLDOVER=1)
(REF_DIS=0 and HMS=1) or
REF_CH=1
REF_DIS=1: Current selected reference disrupted (see Figure 3). This is an internal signal.
REF_CH= 1: Reference change, a change in the REF_SEL pin. This is an internal signal.
Figure 9 - Mode Switching in Normal Mode
4.4
Reference Selection
The active reference input (REF0, REF1) is selected by the REF_SEL pin as shown in Table 4. If the logic value of
the REF_SEL pin is changed when the DPLL is in Normal mode, the ZL30101 will perform a hitless reference
switch.
REF_SEL
(input pin)
Input Reference Selected
0
REF0
1
REF1
Table 4 - Reference Selection
When the REF_SEL inputs are used to force a change from the currently selected reference to another reference,
the action of the LOCK output will depend on the relative frequency and phase offset of the old and new references.
Where the new reference has enough frequency offset and/or TIE-corrected phase offset to force the output
outside the phase-lock-window, the LOCK output will de-assert, the lock-qualify timer is reset, and LOCK will stay
de-asserted for the full lock-time duration. Where the new reference is close enough in frequency and
TIE-corrected phase for the output to stay within the phase-lock-window, the LOCK output will remain asserted
through the reference-switch process.
19
Zarlink Semiconductor Inc.
ZL30101
REF_SEL
REF0
Data Sheet
REF1
LOCK
Lock Time
Note: LOCK pin behaviour depends on phase and frequency offset of REF1.
Figure 10 - Reference Switching in Normal Mode
5.0
Measures of Performance
The following are some PLL performance indicators and their corresponding definitions.
5.1
Jitter
Timing jitter is defined as the high frequency variation of the clock edges from their ideal positions in time. Wander
is defined as the low-frequency variation of the clock edges from their ideal positions in time. High and low
frequency variation imply phase oscillation frequencies relative to some demarcation frequency. (Often 10 Hz or
20 Hz for DS1 or E1, higher for SONET/SDH clocks.) Jitter parameters given in this data sheet are total timing jitter
numbers, not cycle-to-cycle jitter.
5.2
Jitter Generation (Intrinsic Jitter)
Generated jitter is the jitter produced by the PLL and is measured at its output. It is measured by applying a
reference signal with no jitter to the input of the device, and measuring its output jitter. Generated jitter may also be
measured when the device is in a non-synchronizing mode, such as free running or holdover, by measuring the
output jitter of the device. Generated jitter is usually measured with various bandlimiting filters depending on the
applicable standards.
5.3
Jitter Tolerance
Jitter tolerance is a measure of the ability of a PLL to operate properly (i.e., remain in lock and or regain lock in the
presence of large jitter magnitudes at various jitter frequencies) when jitter is applied to its reference. The applied
jitter magnitude and jitter frequency depends on the applicable standards.
5.4
Jitter Transfer
Jitter transfer or jitter attenuation refers to the magnitude of jitter at the output of a device for a given amount of jitter
at the input of the device. Input jitter is applied at various amplitudes and frequencies, and output jitter is measured
with various filters depending on the applicable standards.
For the Zarlink digital PLLs two internal elements determine the jitter attenuation; the internal low pass loop filter
and the phase slope limiter. The phase slope limiter limits the output phase slope to, for example, 61 µs/s.
Therefore, if the input signal exceeds this rate, such as for very large amplitude low frequency input jitter, the
maximum output phase slope will be limited (i.e., attenuated).
Since intrinsic jitter is always present, jitter attenuation will appear to be lower for small input jitter signals than for
large ones. Consequently, accurate jitter transfer function measurements are usually made with large input jitter
signals (for example 75% of the specified maximum tolerable input jitter).
20
Zarlink Semiconductor Inc.
ZL30101
5.5
Data Sheet
Frequency Accuracy
Frequency accuracy is defined as the absolute accuracy of an output clock signal when it is not locked to an
external reference, but is operating in a free running mode.
5.6
Holdover Accuracy
Holdover accuracy is defined as the absolute accuracy of an output clock signal, when it is not locked to an external
reference signal, but is operating using storage techniques. For the ZL30101, the storage value is determined while
the device is in Normal Mode and locked to an external reference signal.
5.7
Pull-in Range
Also referred to as capture range. This is the input frequency range over which the PLL must be able to pull into
synchronization.
5.8
Lock Range
This is the input frequency range over which the synchronizer must be able to maintain synchronization.
5.9
Phase Slope
Phase slope is measured in seconds per second and is the rate at which a given signal changes phase with respect
to an ideal signal. The given signal is typically the output signal. The ideal signal is of constant frequency and is
nominally equal to the value of the final output signal or final input signal. Another way of specifying the phase slope
is as the fractional change per time unit. For example; a phase slope of 61 µs/s can also be specified as 61 ppm.
5.10
Time Interval Error (TIE)
TIE is the time delay between a given timing signal and an ideal timing signal.
5.11
Maximum Time Interval Error (MTIE)
MTIE is the maximum peak to peak delay between a given timing signal and an ideal timing signal within a
particular observation period.
5.12
Phase Continuity
Phase continuity is the phase difference between a given timing signal and an ideal timing signal at the end of a
particular observation period. Usually, the given timing signal and the ideal timing signal are of the same frequency.
Phase continuity applies to the output of the PLL after a signal disturbance due to a reference switch or a mode
change. The observation period is usually the time from the disturbance, to just after the synchronizer has settled to
a steady state.
5.13
Lock Time
This is the time it takes the PLL to frequency lock to the input signal. Phase lock occurs when the input signal and
output signal are aligned in phase with respect to each other within a certain phase distance (not including jitter).
Lock time is affected by many factors which include:
•
initial input to output phase difference,
•
initial input to output frequency difference,
•
PLL loop filter bandwidth,
21
Zarlink Semiconductor Inc.
ZL30101
•
PLL phase slope limiter,
•
in-lock phase distance.
Data Sheet
The presence of input jitter makes it difficult to define when the PLL is locked as it may not be able to align its output
to the input within the required phase distance, dependent on the PLL bandwidth and the input jitter amplitude and
frequency.
Although a short lock time is desirable, it is not always possible to achieve due to other synchronizer requirements.
For instance, better jitter transfer performance is achieved with a lower frequency loop filter which increases lock
time. And better (smaller) phase slope performance (limiter) results in longer lock times.
6.0
Applications
This section contains ZL30101 application specific details for power supply decoupling, reset operation, clock and
crystal operation.
6.1
Power Supply Decoupling
It is recommended to place a 100 nF decoupling capacitor close to the power and ground pairs as shown in Figure
11 to ensure optimal jitter performance.
3.3 V
1.8 V
AV CORE 35
29 AV DD
100 nF
100 nF
33 AGND
AV CORE 14
44 AV DD
100 nF
100 nF
V CORE 12
41 AGND
100 nF
GND 13
45 AV DD
100 nF
V CORE 2
51 AGND
100 nF
GND 1
37 AV DD
100 nF
40 GND
36 AVDD
ZL30101
100 nF
34 GND
25 V DD
100 nF
23 GND
61 V DD
100 nF
1 GND
Figure 11 - Recommended Power Supply Decoupling
22
Zarlink Semiconductor Inc.
ZL30101
6.2
Data Sheet
Master Clock
The ZL30101 can use either a clock or crystal as the master timing source. Zarlink application note ZLAN-68 lists a
number of applicable oscillators and crystals that can be used with the ZL30101.
6.2.1
Clock Oscillator
When selecting a clock oscillator, numerous parameters must be considered. This includes absolute frequency,
frequency change over temperature, phase noise, output rise and fall times, output levels and duty cycle.
1
Frequency
20 MHz
2
Tolerance
4.6 ppm
3
Rise & fall time
< 10 ns
4
Duty cycle
40% to 60%
Table 5 - Typical Clock Oscillator Specification
The output clock should be connected directly (not AC coupled) to the OSCi input of the ZL30101, and the OSCo
output should be left open as shown in Figure 12.
ZL30101
+3.3 V
OSCi
+3.3 V
20 MHz OUT
GND
0.1 µF
OSCo
No Connection
Figure 12 - Clock Oscillator Circuit
6.2.2
Crystal Oscillator
Alternatively, a crystal oscillator may be used. A complete oscillator circuit made up of a crystal, resistor and
capacitors is shown in Figure 13. The Telcordia GR1244-CORE Stratum 3 requirements for holdover stability and
freerun accuracy may not be met with this crystal oscillator circuit.
The accuracy of a crystal oscillator depends on the crystal tolerance as well as the load capacitance tolerance.
Typically, for a 20 MHz crystal specified with a 32 pF load capacitance, each 1 pF change in load capacitance
contributes approximately 9 ppm to the frequency deviation. Consequently, capacitor tolerances and stray
capacitances have a major effect on the accuracy of the oscillator frequency.
The crystal should be a fundamental mode type - not an overtone. The fundamental mode crystal permits a simpler
oscillator circuit with no additional filter components and is less likely to generate spurious responses. A typical
crystal oscillator specification and circuit is shown in Table 6 and Figure 13 respectively.
23
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
1
Frequency
20 MHz
2
Tolerance
as required
3
Oscillation mode
fundamental
4
Resonance mode
parallel
5
Load capacitance
as required
6
Maximum series resistance
50 Ω
Table 6 - Typical Crystal Oscillator Specification
ZL30101
20 MHz
OSCi
1 MΩ
OSCo
100 Ω
1 µH
The 100 Ω resistor and the 1 µH inductor may improve
stability and are optional.
Figure 13 - Crystal Oscillator Circuit
6.3
Power Up Sequence
The ZL30101 requires that the 3.3 V rail is not powered-up later than the 1.8 V rail. This is to prevent the risk of
latch-up due to the presence of parasitic diodes in the IO pads.
Two options are given:
1. Power up the 3.3 V rail fully first, then power up the 1.8 V rail
2. Power up the 3.3 V rail and 1.8 V rail simultaneously, ensuring that the 3.3 V rail voltage is never lower than the
1.8 V rail voltage minus a few hundred millivolts (e.g., by using a schottky diode or controlled slew rate)
24
Zarlink Semiconductor Inc.
ZL30101
6.4
Data Sheet
Reset Circuit
A simple power up reset circuit with about a 60 µs reset low time is shown in Figure 14. Resistor RP is for protection
only and limits current into the RST pin during power down conditions. The reset low time is not critical but should
be greater than 300 ns.
ZL30101
+3.3 V
R
10 kΩ
RST
RP
1 kΩ
C
10 nF
Figure 14 - Power-Up Reset Circuit
25
Zarlink Semiconductor Inc.
ZL30101
7.0
Characteristics
7.1
AC and DC Electrical Characteristics
Data Sheet
Absolute Maximum Ratings*
Parameter
Symbol
Min.
Max.
Units
VDD_R
-0.5
4.6
V
VCORE_R
-0.5
2.5
V
1
Supply voltage
2
Core supply voltage
3
Voltage on any digital pin
VPIN
-0.5
6
V
4
Voltage on OSCi and OSCo pin
VOSC
-0.3
VDD + 0.3
V
5
Current on any pin
IPIN
30
mA
6
Storage temperature
TST
125
°C
7
TQFP 64 pin package power dissipation
PPD
500
mW
8
ESD rating
VESD
2
kV
-55
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
* Voltages are with respect to ground (GND) unless otherwise stated.
Recommended Operating Conditions*
Characteristics
1
Supply voltage
2
Core supply voltage
3
Operating temperature
Sym.
Min.
Typ.
Max.
Units
VDD
2.97
3.30
3.63
V
VCORE
1.62
1.80
1.98
V
TA
-40
25
85
°C
* Voltages are with respect to ground (GND) unless otherwise stated.
26
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
DC Electrical Characteristics*
Characteristics
1
Supply current with: OSCi = 0 V
Sym.
Min.
Max.
Units
IDDS
3.0
6.5
mA
2
OSCi = Clock, OUT_SEL=0
IDD
32
52
mA
3
OSCi = Clock, OUT_SEL=1
IDD
42
71
mA
4
Core supply current with: OSCi = 0 V
ICORES
0
22
µA
5
OSCi = Clock
ICORE
14
20
mA
Notes
outputs loaded
with 30 pF
6
Schmitt trigger Low to High
threshold point
Vt+
1.47
1.5
V
7
Schmitt trigger High to Low
threshold point
Vt-
0.8
1.0
V
8
Input leakage current
IIL
-105
105
µA
VI = VDD or 0 V
9
High-level output voltage
VOH
2.4
V
IOH = 8 mA for clock and
frame-pulse outputs,
4 mA for status outputs
10
Low-level output voltage
VOL
V
IOL = 8 mA for clock and
frame-pulse outputs,
4 mA for status outputs
0.4
All device inputs are
Schmitt trigger type.
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
* Voltages are with respect to ground (GND) unless otherwise stated.
AC Electrical Characteristics* - Timing Parameter Measurement Voltage Levels (see Figure 15)
Characteristics
Sym.
CMOS
Units
VT
1.5
V
1
Threshold voltage
2
Rise and fall threshold voltage high
VHM
2.0
V
3
Rise and fall threshold voltage low
VLM
0.8
V
Notes
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
* Voltages are with respect to ground (GND) unless otherwise stated.
Timing Reference Points
V HM
VT
V LM
ALL SIGNALS
tIF, tOF
tIR, tOR
Figure 15 - Timing Parameter Measurement Voltage Levels
27
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
AC Electrical Characteristics* - Input Timing for REF0 and REF1 References (see Figure 16)
Characteristics
Symbol
Min.
Typ.
Max.
Units
1
8 kHz reference period
tREF8KP
121
125
128
µs
2
1.544 MHz reference period
tREF1.5P
338
648
950
ns
3
2.048 MHz reference period
tREF2P
263
488
712
ns
4
8.192 MHz reference period
tREF8P
63
122
175
ns
5
16.384 MHz reference period
tREF16P
38
61
75
ns
6
reference pulse width high or low
tREFW
15
ns
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
* Period Min/Max values are the limits to avoid a single-cycle fault detection. Short-term and long-term average periods must be within
Out-of-Range limits.
AC Electrical Characteristics* - Input to Output Timing for REF0 and REF1 References (see Figure 16)
Characteristics
Symbol
Min.
Max.
Units
1
8 kHz reference input to F8/F32o delay
tREF8KD
0.7
2.0
ns
2
1.544 MHz reference input to C1.5o delay
tREF1.5D
2.4
3.0
ns
3
1.544 MHz reference input to F8/F32o delay
tREF1.5_F8D
2.5
3.3
ns
4
2.048 MHz reference input to C2o delay
tREF2D
2.0
3.0
ns
5
2.048 MHz reference input to F8/F32o delay
tREF2_F8D
2.2
3.3
ns
6
8.192 MHz reference input to C8o delay
tREF8D
5.2
6.2
ns
7
8.192 MHz reference input to F8/F32o delay
tREF8_F8D
5.5
6.3
ns
8
16.384 MHz reference input to C16o delay
tREF16D
2.6
3.3
ns
9
16.384 MHz reference input to F8/F32o delay
tREF16_F8D
-28.0
-27.2
ns
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
tREF<xx>P
tREFW
tREFW
REF0/1
output clock with
the same
frequency as REF
tREF<xx>D
tREF8kD, tREF<xx>_F8D
F8_32o
Figure 16 - Input to Output Timing
28
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
AC Electrical Characteristics* - Output Timing (see Figure 17)
Characteristics
Sym.
Min.
Max.
Units
1
C1.5o pulse width low
tC1.5L
323.1
323.7
ns
2
C1.5o delay
tC1.5D
-0.6
0.6
ns
3
C2o pulse width low
tC2L
243.2
243.8
ns
4
C2o delay
tC2D
-0.4
0.3
ns
5
F4o pulse width low
tF4L
243.5
244.2
ns
6
F4o delay
tF4D
121.5
122.2
ns
7
C4o pulse width low
tC4L
121.2
122.3
ns
8
C4o delay
tC4D
-0.3
1.0
ns
9
F8o pulse width high
tF8H
121.6
123.2
ns
10
C8o pulse width low
tC8L
60.3
61.2
ns
11
C8o delay
tC8D
-0.4
0.2
ns
12
F16o pulse with low
tF16L
60.6
61.1
ns
13
F16o delay
tF16D
29.9
30.8
ns
14
C16o pulse width low
tC16L
28.7
30.8
ns
15
C16o delay
tC16D
-0.5
1.4
ns
16
F32o pulse width high
tF32H
30.0
31.8
ns
17
C32o pulse width low
tC32L
14.8
15.3
ns
18
C32o delay
tC32D
-0.5
0.1
ns
19
F65o pulse with low
tF65L
14.8
15.4
ns
20
F65o delay
tF65D
7.1
8.0
ns
21
C65o pulse width low
tC65L
7.2
8.1
ns
22
C65o delay
tC65D
-1.0
0.0
ns
23
Output clock and frame pulse
rise time
tOR
1.0
2.0
ns
24
Output clock and frame pulse fall
time
tOF
1.2
2.3
ns
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
29
Zarlink Semiconductor Inc.
Notes
outputs loaded
with 30 pF
ZL30101
Data Sheet
tC1.5L
tC1.5D
C1.5o
tC2L
tC2D
C2o
tF4D
tF4L
F4o
tC4L
tC4D
C4o
tF8H
F8o
tC8L
tC8D
C8o
tF16D
tF16L
F16o
tC16L
tC16D
C16o
tF32H
F32o
tC32L
tC32D
C32o
tF65D
tF65L
F65o
tC65L
tC65D
C65o
F32o, C32o, F65o and C65o are drawn on a larger scale than the other waveforms in this diagram.
Figure 17 - Output Timing Referenced to F8/F32o
30
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
AC Electrical Characteristics* - OSCi 20 MHz Master Clock Input
Characteristics
Sym.
Min.
Max.
Units
1
Oscillator tolerance
-4.6
4.6
ppm
2
Duty cycle
40
60
%
3
Rise time
10
ns
4
Fall time
10
ns
Notes
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
7.2
Performance Characteristics
Performance Characteristics* - Functional
Characteristics
Min.
Max.
Units
0.01
ppm
Notes
1
Holdover accuracy
2
Holdover stability
0
ppm
Determined by stability of the
20 MHz master clock oscillator
3
Freerun accuracy
0
ppm
Determined by accuracy of the
20 MHz master clock oscillator
4
Capture range
-12
+12
ppm
The 20 MHz master clock oscillator set
at 0 ppm
5
Reference Out of Range
Threshold (including hysteresis)
-9.2
-12
+9.2
+12
ppm
The 20 MHz master clock oscillator set
at 0 ppm
Lock Time
7
1.8 Hz loop filter
40
s
±12 ppm frequency offset, BW_SEL=0
8
58 Hz and 922 Hz loop filter
1
s
±12 ppm frequency offset, BW_SEL=1
Output Phase Continuity (MTIE)
9
Reference switching
13
ns
10
Switching from Normal mode to
Holdover mode
0
ns
11
Switching from Holdover mode
to Normal mode
13
ns
Output Phase Slope
12
1.8 Hz Filter
61
µs/s
BW_SEL=0
13
58 Hz and 922 Hz Filter
9.5
ms/s
BW_SEL=1
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
31
Zarlink Semiconductor Inc.
ZL30101
Data Sheet
Performance Characteristics*: Output Jitter Generation - ANSI T1.403 Conformance
ANSI T1.403
Jitter Generation Requirements
Signal
Jitter
measurement
filter
Limit in
UI
Equivalent
limit in the
time domain
ZL30101
maximum jitter
generation
Units
DS1 Interface
1
2
C1.5o (1.544 MHz)
8 kHz to 40 kHz
0.07 UIpp
45.3
0.30
nspp
10 Hz to 40 kHz
0.5 UIpp
324
0.32
nspp
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
Performance Characteristics*: Output Jitter Generation - ITU-T G.812 Conformance
ITU-T G.812
Jitter Generation Requirements
Signal
Jitter
measurement
filter
Limit in
UI
Equivalent
limit in the
time domain
ZL30101
maximum jitter
generation
24.4
0.36
Units
E1 Interface
1
C2o (2.048 MHz)
20 Hz to 100 kHz
0.05 UIpp
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
Performance Characteristics* - Unfiltered Intrinsic Jitter
Max.
[nspp]
Characteristics
1
C1.5o (1.544 MHz)
0.45
2
C2o (2.048 MHz)
0.47
3
C4o (4.096 MHz)
0.42
4
C8o (8.192 MHz)
0.42
5
C16o (16.384 MHz)
0.56
6
C32o (32.768 MHz)
0.46
7
C65o (65.536 MHz)
0.49
8
F4o (8 kHz)
0.40
9
F8o (8 kHz)
0.33
10
F16o (8 kHz)
0.43
11
F32o (8 kHz)
0.36
12
F65o (8 kHz)
0.42
* Supply voltage and operating temperature are as per Recommended Operating Conditions.
32
Zarlink Semiconductor Inc.
Notes
nspp
Package Code
c Zarlink Semiconductor 2002 All rights reserved.
ISSUE
ACN
DATE
APPRD.
Previous package codes
For more information about all Zarlink products
visit our Web Site at
www.zarlink.com
Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable.
However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such
information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or
use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual
property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in
certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink.
This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part
of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other
information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the
capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute
any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and
suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does
not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in
significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request.
Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system
conforms to the I2C Standard Specification as defined by Philips.
Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc.
Copyright Zarlink Semiconductor Inc. All Rights Reserved.
TECHNICAL DOCUMENTATION - NOT FOR RESALE