Materials 1. Insulator, POM, yellow 2. Insulator, PBT, black 3. Center contact, C5191 phosphor bronze, 2 μm nickel plated 4. Shell, C3604 brass, 2 μm nickel plated Electrical requirements Dielectric strength: 1 min @ 500 Vac Insulation resistance: 100 MΩ @ 500 Vdc Contact resistance: 30 mΩ or less Rated voltage: 20 Vdc Rated current: 4 A Mechanical requirements Insertion force: 0.5-2 kgf Withdrawal force: 0.3-1.5 kgf Durability: 5000 mating cycles while maintaining; 0.4-2 kgf insertion force, 0.2-1.5 kgf withdrawal force and a less than 100 mΩ contact resistance. Environmental requirements Damp test: 40 °C, RH 90-100% for 96 hrs. Cool to ambient and recover for 2 hours. Maintain dielectric strength of 500 Vac for 1 min, insulation resistance of 50 MΩ @ 500 Vdc minimum and a contact resistance of 100 mΩ or less. Dry test: 70 °C, RH 70-85% for 96 hrs. Cool to ambient and recover for 2 hours. Maintain insulation resistance of 50 MΩ @ 500 Vdc minimum and a contact resistance of 100 mΩ or less. Salt spray test: 35 °C, RH 90-95%, 5% NaCl mist for 24 hrs. Wash parts after test. Maintain mechanical requirements and a contact resistance of less than 80 mΩ. Operating range -25 to 70 °C, relative humidity of 85% or less Revision Date 10/21/2009 Initial release A1 11/9/2012 Added test data 3.6 0.15 ±0.05 4.2 ±0.30 0.7 13.6 ±0.30 3 4.5 ±0.20 20 ±0.50 4 2 +0.10 1.35 - 0 3 Notes RoHS compliant Function test: no open, no short circuit, no INT DIMENSIONS ARE IN MILLIMETERS TOLERANCES: X: 0.5 mm X.X: 0.3 mm X.XX: 0.05 mm 5 1 2.6 1 ±0.10 Description A 1.2 3.3 ±0.20 0.5 ±0.10 3.5 1.7 ±0.20 4 20802 Sockeye Place #130 Bend, OR 97701 USA tel 541.323.3228 fax 541.323.4202 800 877.670.7118 www.tensility.com DESCRIPTION: Connector, dc plug, 3.5x1.35xL20mm, molding style, spring contacts SIZE Part number A 50-00056 SCALE: 2:1 3 2 SHEET 1 OF 1 WEIGHT: 1