TENSILITY 50

Revision
A
Date
11/7/2012
2.6
13.6 ±0.30
3
4.5 ±0.20
17.3 ±0.30
20 ±0.50
3
2
+0.10
1.35 - 0
4
1
10 ±0.50
Description
Notes
RoHS compliant
Initial release
Function test: no open, no short circuit, no INT
DIMENSIONS ARE IN MILLIMETERS
TOLERANCES:
X:
0.5 mm
X.X:
0.3 mm
X.XX: 0.05 mm
5
0.2 ±0.05
1.2
3.3 ±0.20
0.5 ±0.10
1 ±0.10
3.6
1.8 ±0.20
+0.05
3.5 - 0
Materials
1. Insulation block, POM, yellow
2. Insulator, PBT + 15% glass fiber, white
3. Shell, C3604 brass, 2 μm nickel plated
4. Spring contact, C5191 phosphor bronze, 2 μm nickel
plated


Electrical requirements
Dielectric strength: 1 min @ 500 Vac
Insulation resistance: 100 MΩ @ 500 Vdc
Contact resistance: 30 mΩ or less
Rated voltage: 20 Vdc
Rated current: 4 A

Mechanical requirements
Insertion force: 0.5-2 kgf
Withdrawal force: 0.3-1.5 kgf
Durability: 5000 mating cycles while maintaining; 0.4-2 kgf
 insertion force, 0.2-1.5 kgf withdrawal force and a less than
100 mΩ contact resistance.

Environmental requirements
Damp test: 40 °C, RH 90-100% for 96 hrs. Cool to ambient
and recover for 2 hours. Maintain dielectric strength of 500
Vac for 1 min, insulation resistance of 50 MΩ @ 500 Vdc
minimum and a contact resistance of 100 mΩ or less.

Dry test: 70 °C, RH 70-85% for 96 hrs. Cool to ambient and
recover for 2 hours. Maintain insulation resistance of 50
MΩ @ 500 Vdc minimum and a contact resistance of 100
mΩ or less.

Salt spray test: 35 °C, RH 90-95%, 5% NaCl mist for 24 hrs.
Wash parts after test. Maintain mechanical requirements
and a contact resistance of less than 80 mΩ.

Operating range
-25 to 70 °C, relative humidity of 85% or less
4
20802 Sockeye Place #130
Bend, OR 97701 USA
tel 541.323.3228 fax 541.323.4202
800 877.670.7118 www.tensility.com
DESCRIPTION:
Connector, dc plug, 3.5x1.35xL20mm, brass,
nickel plated, molding type, white insulators
SIZE Part number
A
50-00315
SCALE: 2:1
3
2
WEIGHT:
SHEET 1 OF 1
1