TI 74ACT11139D

74ACT11139
DUAL 2-LINE TO 4-LINE DECODER/DEMULTIPLEXER
SCAS175A – SEPTEMBER 1991 – REVISED APRIL 1996
D
D
D
D
D
D
D
D
Inputs Are TTL-Voltage Compatible
Designed Specifically for High-Speed
Memory Decoders and Data Transmission
Systems
Incorporates Two Enable Inputs to Simplify
Cascading and/or Data Reception
Fully Synchronous Operation for Counting
Center-Pin VCC and GND Configurations
Minimize High-Speed Switching Noise
EPIC  (Enhanced-Performance Implanted
CMOS) 1-µm Process
500-mA Typical Latch-Up Immunity at
125°C
Package Options Include Plastic
Small-Outline (D) and Thin Shrink
Small-Outline (PW) Packages, and
Standard Plastic 300-mil DIPs (N)
D, N, OR PW PACKAGE
(TOP VIEW)
1Y1
1Y2
1Y3
GND
2Y0
2Y1
2Y2
2Y3
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
1Y0
1A
1B
1G
VCC
2G
2A
2B
description
The 74ACT11139 is designed for use in high-performance memory-decoding or data-routing applications that
require very short propagation delay times. In high-performance memory systems, this decoder is used to
minimize the effects of system decoding.
The 74ACT11139 is composed of two individual 2-line to 4-line decoders in a single package. The active-low
enables (1G or 2G) can be used as data lines in demultiplexing applications. This decoder/demultiplexer
features fully buffered inputs, each of which represents only one normalized load to its driving circuit.
The 74ACT11139 is characterized for operation from –40°C to 85°C.
FUNCTION TABLE
INPUTS
OUTPUTS
G
B
A
Y0
Y1
Y2
Y3
H
X
X
H
H
H
H
L
L
L
L
H
H
H
L
L
H
H
L
H
H
L
H
L
H
H
L
H
L
H
H
H
H
H
L
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
Copyright  1996, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
74ACT11139
DUAL 2-LINE TO 4-LINE DECODER/DEMULTIPLEXER
SCAS175A – SEPTEMBER 1991 – REVISED APRIL 1996
logic symbol†
1A
1B
15
14
DMUX
1
2
0
G 3
13
1G
2A
2B
0
1
2
3
16
1Y0
1
1Y1
2
1Y2
3
1Y3
5
10
2Y0
6
2Y1
9
7
11
2Y2
8
2G
2Y3
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram (positive logic)
16
1G
13
1
1Y0
1Y1
2
1A
1B
1Y2
15
3
14
5
2G
11
6
1Y3
2Y0
2Y1
7
2A
2B
2
2Y2
10
8
9
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2Y3
74ACT11139
DUAL 2-LINE TO 4-LINE DECODER/DEMULTIPLEXER
SCAS175A – SEPTEMBER 1991 – REVISED APRIL 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
Input voltage range, VI (see Note 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±200 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2): D package . . . . . . . . . . . . . . . . . . . . 1.3 W
N package . . . . . . . . . . . . . . . . . . . . 1.1 W
PW package . . . . . . . . . . . . . . . . . . . 0.5 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150_C and a board trace length of 750 mils,
except for the N package, which has a trace length of zero.
recommended operating conditions (see Note 3)
MIN
NOM
MAX
4.5
5
5.5
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
Input voltage
0
VO
IOH
Output voltage
0
IOL
∆t/∆v
High-level input voltage
2
UNIT
V
V
0.8
V
VCC
VCC
V
High-level output current
–24
mA
Low-level output current
24
mA
0
10
ns/V
–40
85
°C
Input transition rise or fall rate
TA
Operating free-air temperature
NOTE 3: Unused or floating inputs must be held high or low.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
V
3
74ACT11139
DUAL 2-LINE TO 4-LINE DECODER/DEMULTIPLEXER
SCAS175A – SEPTEMBER 1991 – REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
4.5 V
IOH = –50
50 mA
VOH
24 mA
IOH = –24
IOH = –75 mA†
IOL = 24 mA
∆ICC‡
Ci
MIN
4.4
4.4
5.5 V
5.4
5.4
4.5 V
3.94
3.8
5.5 V
4.94
0.1
V
0.1
5.5 V
0.1
0.1
4.5 V
0.36
0.44
5.5 V
0.36
0.44
V
1.65
mA
±0.1
±1
5.5 V
8
80
mA
5.5 V
0.9
1
mA
5.5 V
IO = 0
Other inputs at VCC or GND
UNIT
4.8
5.5 V
VI = VCC or GND,
One input at 3.4 V,
MAX
3.85
4.5 V
IOL = 75 mA†
VI = VCC or GND
II
ICC
TA = 25°C
TYP
MAX
5.5 V
IOL = 50 mA
VOL
MIN
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
pF
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A or B
Y
tPLH
tPHL
G
Y
TA = 25°C
MIN
TYP
MAX
MIN
MAX
1.7
5.7
7.8
1.7
8.5
2.1
5.5
7.4
2.1
8.5
2.7
5.3
7.2
2.7
7.9
1.8
4.3
6.7
1.8
7.5
UNIT
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
4
TEST CONDITIONS
Power dissipation capacitance
CL = 50 pF,
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
f = 1 MHz
TYP
UNIT
47
pF
74ACT11139
DUAL 2-LINE TO 4-LINE DECODER/DEMULTIPLEXER
SCAS175A – SEPTEMBER 1991 – REVISED APRIL 1996
PARAMETER MEASUREMENT INFORMATION
3V
Input
(see Note B)
From Output
Under Test
CL = 50 pF
(see Note A)
1.5 V
1.5 V
0V
tPHL
500 Ω
tPLH
50% VCC
Output
VOH
50% VCC
VOL
VOLTAGE WAVEFORMS
LOAD CIRCUIT
NOTES: A. CL includes probe and jig capacitance.
B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated