ADPOW APTDF500U40

APTDF500U40
Single diode
Power Module
VCES = 400V
IC = 500A @ Tc = 80°C
Application
•
Anti-Parallel diode
- Switchmode Power Supply
- Inverters
Snubber diode
Uninterruptible Power Supply (UPS)
Induction heating
Welding equipment
High speed rectifiers
Electric vehicles
•
•
•
•
•
•
Features
A2
A S P M™
A S P M™
A1
•
•
•
•
•
•
Ultra fast recovery times
Soft recovery characteristics
Very low stray inductance
High blocking voltage
High current
Low leakage current
Benefits
K2
•
•
•
•
Low losses
Low noise switching
Direct mounting to heatsink (isolated package)
Low junction to case thermal resistance
Absolute maximum ratings
Symbol
VR
VRRM
Parameter
Maximum DC reverse Voltage
Maximum Peak Repetitive Reverse Voltage
IF(AV)
Maximum Average Forward
Current
IF(RMS)
IFSM
RMS Forward Current
Non-Repetitive Forward Surge Current
Duty cycle = 50%
Max ratings
Unit
400
V
Tc = 25°C
500
Tc = 80°C
500
850
5000
Tj = 25°C
A
These Devices are sensitive to Electrostatic Discharge. Proper Handing Procedures Should Be Followed.
APT website – http://www.advancedpower.com
1-3
APTDF500U40 – Rev 0 June, 2003
K1
APTDF500U40
All ratings @ Tj = 25°C unless otherwise specified
Symbol Characteristic
VF
Diode Forward Voltage
IRM
Maximum Reverse Leakage Current
CT
Junction Capacitance
Symbol Characteristic
IF=1A,VR=30V
di/dt = 15A/µs
IF = 500A
VR = 240V
di/dt=1000A/µs
Reverse Recovery Time
trr3
tfr2
IRRM1
IRRM2
Qrr1
Qrr2
Vfr1
Vfr2
dIM/dt
Forward Recovery Time
Reverse Recovery Current
IF = 500A
VR = 240V
di/dt=1000A/µs
Reverse Recovery Charge
Forward Recovery Voltage
Rate of Fall of Recovery Current
Torque
Mounting torque
Wt
Package Weight
Max
1.5
1.5
Typ
Max
50
Tj = 25°C
120
Tj = 100°C
260
210
Tj = 100°C
220
50
Tj = 100°C
120
Tj = 25°C
3
Tj = 100°C
15.6
19
Tj = 100°C
19
Tj = 25°C
1200
Tj = 100°C
1800
Min
Typ
To heatsink
For terminals
M5
M6
APT website – http://www.advancedpower.com
ns
A
µC
V
A/µs
Max
0.08
2500
-40
-40
-40
2.5
3
Unit
ns
Tj = 25°C
Tj = 25°C
µA
pF
Tj = 25°C
Tj = 25°C
Unit
V
1.3
2500
5000
Min
Thermal and package characteristics
Symbol Characteristic
RthJC
Junction to Case
RMS Isolation Voltage, any terminal to case
VISOL
t =1 min, I isol<1mA, 50/60Hz
TJ
Operating junction temperature range
TSTG
Storage Temperature Range
TC
Operating Case Temperature
Typ
800
Test Conditions
trr1
tfr1
Min
VR = 200V
Dynamic Characteristics
trr2
Test Conditions
IF = 500A
IF = 1000A
IF = 500A
Tj = 150°C
Tj = 25°C
VR = 400V
Tj = 150°C
Unit
°C/W
V
150
125
100
3.5
4
250
°C
N.m
g
2-3
APTDF500U40 – Rev 0 June, 2003
Electrical Characteristics
APTDF500U40
APT reserves the right to change, without notice, the specifications and information contained herein
APT's products are covered by one or more of U.S patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522
5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. U.S and Foreign patents pending. All Rights Reserved.
APT website – http://www.advancedpower.com
3-3
APTDF500U40 – Rev 0 June, 2003
A S P M™
A S P M™
Package outline