AXTAL AXHV2001

Issue: 01
Specification
AXHV2001
Oscillator type :
VCO – Voltage Controlled Oscillator
Parameter
min.
typ.
max.
Unit
Date: 2005-12-08
Condition
1800
2900
MHz
@ 25°C
Frequency tuning range
Frequency adjustment range
EFC voltage VC
0.2
15
V
positive
EFC slope (∆f / ∆VC)
RF output
Signal waveform
SINUS
Amplitude
+4
+6
dBm
RL = 50 Ω
-90
dBc/Hz @ 100 kHz
Phase Noise
Supply voltage VS
4.75
5
5.25
V
Current consumption (steady state)
15
mA
-10
+60
°C
Operating temperature range
-20
+70
°C
Operable temperature range
-40
+85
°C
Storage temperature range
12.7 x 12.7 x 6.1
mm
Enclosure (see drawing) LxWxH
5
gram
Weight
bulk
IEC 60286-3
Packing
1500
V
HBM, IEC 61000-4-2
ESD Sensitivity
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXHV2001
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Frequency Range [MHz]
1800-2900
AXHV2001
page 1(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Pin connections
Enclosure drawing
Pin # Symbol
P1
VC
P2 RF OUT
P3
VS
P4
N.C.
All
GND
others
Function
Control Voltage (EFC)
RF Output
Supply Voltage
Not Connected
Ground
Typical Performance
HV2001
VCO 1.8 GHz bis 2.9 GHz
fres/GHz
3
5V/15mA
Phase Noise: <-90dBc/Hz in 100kHz
2.8
2.6
2.4
2.2
2
1.8
1.6
0
5
10
15
Vtune/V
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV2001
page 2(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
HV2001
VCO 1.8 GHz bis 2.9 GHz
Pout/dBm
10
8
6
4
2
0
0
5
10
15
Vtune/V
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV2001
page 3(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]