Issue: 01 Specification AXHV2001 Oscillator type : VCO – Voltage Controlled Oscillator Parameter min. typ. max. Unit Date: 2005-12-08 Condition 1800 2900 MHz @ 25°C Frequency tuning range Frequency adjustment range EFC voltage VC 0.2 15 V positive EFC slope (∆f / ∆VC) RF output Signal waveform SINUS Amplitude +4 +6 dBm RL = 50 Ω -90 dBc/Hz @ 100 kHz Phase Noise Supply voltage VS 4.75 5 5.25 V Current consumption (steady state) 15 mA -10 +60 °C Operating temperature range -20 +70 °C Operable temperature range -40 +85 °C Storage temperature range 12.7 x 12.7 x 6.1 mm Enclosure (see drawing) LxWxH 5 gram Weight bulk IEC 60286-3 Packing 1500 V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXHV2001 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany Frequency Range [MHz] 1800-2900 AXHV2001 page 1(3) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Pin connections Enclosure drawing Pin # Symbol P1 VC P2 RF OUT P3 VS P4 N.C. All GND others Function Control Voltage (EFC) RF Output Supply Voltage Not Connected Ground Typical Performance HV2001 VCO 1.8 GHz bis 2.9 GHz fres/GHz 3 5V/15mA Phase Noise: <-90dBc/Hz in 100kHz 2.8 2.6 2.4 2.2 2 1.8 1.6 0 5 10 15 Vtune/V GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV2001 page 2(3) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] HV2001 VCO 1.8 GHz bis 2.9 GHz Pout/dBm 10 8 6 4 2 0 0 5 10 15 Vtune/V Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV2001 page 3(3) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]