Issue: 03 Specification AXIS10 Oscillator type : SMD VCXO in CO 26 package Parameter min. Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating temperature range (steady state) vs. supply voltage variation vs. load change long term (aging) per year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC linearity EFC input impedance RF output Signal waveform Output signal HIGH VOH Output signal LOW VOL typ. max. 1.544 100 16.384/19.440/38.880/52.000 -20 20 ±5 -3 -1 ± 100 0.5 0.3 Date: 2005-06-10 Unit Condition MHz MHz ppm ppm ppm See Note 1 3 1 ±1 ppm VS ±5% ppm Load ±5% ppm/year @ 40°C 4.5 3.0 ppm V V positive 10 Option I = ”50” Option I = “33” % kΩ 100 HCMOS 2.4 VS-0.5V 0.4 0.5 10 Rise & decay time Symmetry (duty cycle) Start-up time Supply voltage VS 40 Current consumption (steady state) Operating temperature range Operable temperature range Storage temperature range Enclosure (see drawing) (LxWxH) Weight Packing ESD Sensitivity 60 10 4.75 5.0 5.25 3.13 3.3 3.47 45 85 -20 +70 -40 +85 -45 +90 -55 +105 14.4 x 9.5 x 5.5 max 3 Tape & reel 1500 V V V V ns % ms V V mA mA °C °C °C °C mm gram V TTL load (fan-out 2) HCMOS load 15 pF TTL load (fan-out 2) HCMOS load 15 pF according to logic family @ VS/2 Option I = “50” Option I = “33” Option I = “50” Option I = “33” Option II = “2070” Option II = “4085” IEC 61837 CO 27 IEC 60286-3 HBM as in IEC 610004-2 Notes: 1. Frequency stability = initial tolerance + stability vs. temperature 2. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXIS10 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany Option I 33 Option II 2070 Frequency [MHz] 52.000 AXIS10 page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin connections Pin # Symbol 1 VC 2* N.C. 3 GND 4 RF OUT 5* N.C. 6 Vs Function Control Voltage (EFC) No Connection Ground RF Output No Connection Supply Voltage * Note: Pins 2 and 5 may not be present Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIS10 page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]