PU65 - PROTEK POWER

50-65 WATT SWITCHING POWER SUPPLIES
D E SCR I PTI ON
PU65 SERIES
(LVD )
RoHS
The PU65 series of compact, open PCB constructed,
AC-DC switching power supplies are capable of delivering
50 to 65 watts of continuous output power. They operate at
85 to 264VAC input voltage without the need of voltage
selection. They are ideally suited for use in today’s CRT
terminals, disc drive systems, microprocessor based
systems, portable equipment and many other applications.
All models meet the safety requirements of UL, CSA and
IEC.
F EATU R E S
‧
‧
‧
‧
‧
‧
‧
‧
Recognized or certified by UL, CSA and TÜV
Small size, light weight
100% burn-in
W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C
Input surge current protection
O v e r v o l ta g e p r o t e c t i o n
Overcurrent protection
C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
IN PUT SPEC IF ICAT ION S
Input voltage:
UL 60950-1
File No. E137410
CSA C22.2 No. 60950-1
File No. LR93632
TÜV EN60950-1
Certificate No. R9172041
85 to 264VAC
Input frequency:
47 to 63Hz
Input current:
1.60A(rms)for 115VAC
1.00A(rms)for 230VAC
0.47mA max. @ 115VAC, 60Hz
0.85mA max. @ 230VAC, 50Hz
Earth leakage current:
(Touch current)
Saf et y Sta n da rd A ppr o va ls:
GENERAL SPECIFICATIONS
Switching frequency:
Efficiency:
OUTPUT SPECIFICATIONS
Output voltage/current:
See rating chart
Total output power:
65 watts maximum
Ripple and noise:
Overvoltage protection:
1﹪peak to peak maximum
Provided on output #1 only; set at
112-132﹪of its nominal output
voltage
Overcurrent protection:
All outputs protected to short
circuit conditions
Temperature coefficient:
All outputs ±0.04﹪/℃ maximum
Transient response:
Maximum excursion of 4﹪ or
better on all models, recovering to
1﹪ of final value within 500us
after a 25﹪ step load change
E N V IR O N M ENTA L SP E C IF ICATI O N S
Hold-up time:
32KHz ± 5KHz
70﹪minimum on single output models
withVo ≧ 12V, 65% minimum on the
others
10 msec minimum at 110VAC
Line regulation:
±0.5﹪maximum at full load
Inrush current:
15 amps @ 115VAC or 30 amps
@ 230VAC, at 25℃ cold start
3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
400,000 hours minimum at full load at
MTBF:
25℃ ambient, calculated per
MIL-HDBK-217F
EMC Performance (EN55024)
Withstand voltage:
EN55022:
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
Class B conducted, class B radiated
Class B conducted, class B radiated
Class B conducted, class B radiated
Harmonic distortion, class A
Line flicker
ESD, ± 8KV air and ± 4KV contact
Radiated immunity, 3V/m
Operating temperature:
0℃ to +70℃
EN61000-4-4:
Fast transient/burst, ± 1KV
Storage temperature:
-40℃ to +85℃
EN61000-4-5:
Surge, ± 1KV diff., ± 2KV com.
5﹪ to 95﹪ non-condensing
Derate from 100﹪ at +50℃
linearly to 50﹪ at +70℃
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
EN61000-4-11:
Magnetic field immunity, 1A/m
Voltage dips, 30% reduction for
500ms and >95% reduction for 10ms
Relative humidity:
Derating:
1-5
PU65 SERIES
UNIVERSAL INPUT
OUTPUT VOLTAGE/CURRENT RATING CHART
(1)(2)
MODEL
Output #1
Vnom Imin. Imax. Tol.
PU65-10
PU65-12
PU65-13
PU65-14
PU65-23
PU65-24
PU65-25
PU65-30
PU65-31
PU65-32
PU65-33
PU65-35-1
PU65-39
PU65-40
PU65-45-1
5V
12V
15V
24V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
NOTES: 1.
2.
0A
0A
0A
0A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
10A
5.5A
4.5A
3.0A
6.0A
6.0A
6.0A
6.0A
6.0A
6.0A
6.0A
2.0A
6.0A
6.0A
6.0A
2%
1%
1%
1%
3%
3%
3%
3%
3%
3%
3%
3%
3%
3%
3%
Output #2
Vnom. Imin. Imax. Tol.
(N/A)
(N/A)
(N/A)
(N/A)
0.5A 3.0A
0.4A 3.0A
0.3A 2.0A
0.5A 3.0A
0.5A 3.0A
0.4A 3.0A
0.4A 3.0A
0.3A 1.2A
0.3A 2.0A
0.5A 3.0A
0.2A 1.0A
+12V
+15V
+24V
+12V
+12V
+15V
+15V
+24V
+24V
+12V
+15V
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
Output #3
Vnom. Imin. Imax.
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
0.1A 0.5A
0.1A 0.5A
0.1A 0.5A
0.1A 0.5A
0.2A 1.0A
0.1A 0.5A
0.1A 0.5A
0.1A 0.75A
-5V
-12V
-15V
-12V
-24V
-12V
-12V
+25V
Tol.
Output #4
Vnom. Imin. Imax. Tol.
10%
10%
10%
10%
10%
10%
10%
10%
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
0.1A 0.50A 10%
0.1A 1.0A 10%
-5V
-12V
Maximum
Output
Power
50W
65W
65W
65W
65W
65W
65W
65W
65W
65W
65W
65W
65W
65W
65W
All multiple output models may be operated at no-load without damage. At no-load, output voltage tolerance
increases to 10%.
Safety agency approvals are for the above listed models in PCB format. To order a model with a metallic L-bracket or
box, add suffix “B” for L-bracket format or “C” for enclosed format to the model number (mechanical details shown in
page 7-2), e.g. PU65-25C.
MECHANICAL SPECIFICATIONS
NOTES:
1.
Dimensions shown in inch [mm]
2.
Tolerance 0.02 [0.5] maximum
3.
Input connector mates with Molex housing
09-50-3031 and Molex 2878 series crimp terminal.
4.
Output connector mates with Molex housing
09-50-3081 and Molex 2878 series crimp terminal.
5.
Weight: 400 grams (PCB format).
6.
The “½” marked mounting hole is for system
grounding through a metallic stand-off to the
system chassis.
PIN CHART
MODEL
PIN
1
2
3
4
5
6
7
8
PU65-10
PU65-13
PU65-12
PU65-14
OUTPUT
#1
OUTPUT
#1
OUTPUT
#1
OUTPUT
#1
RETURN
RETURN
RETURN
RETURN
PU65-23
PU65-25
PU65-24
OUTPUT
#1
OUTPUT
#1
COMMON
RETURN
COMMON
RETURN
OUTPUT
#2
OUTPUT
#2
N.C.
N.C.
PU65-30
PU65-31
PU65-32
PU65-33
PU65-35-1 PU65-39
OUTPUT
#1
OUTPUT
#1
COMMON
RETURN
COMMON
RETURN
OUTPUT
#2
OUTPUT
#2
OUTPUT
#3
N.C.
PU65-40
OUTPUT
#1
OUTPUT
#1
COMMON
RETURN
COMMON
RETURN
OUTPUT
#2
OUTPUT
#2
OUTPUT
#3
OUTPUT
#4
PU65-45-1
1-6