TRUMPOWER TFC130S

TRUMPower
PFC 130 WATT POWER SUPPLIES
DESCRIPTION
TFC130 SERIES
The TFC130 series incorporates creative high
efficiency circuitry, high power density (6.94
3
Watts/in ) and active Power Factor Correction
(PFC) to meet the requirements of data
networking, computing and telecommunication
systems.
(SINGLE OUTPUT)
(LVD)
RoHS
FEATURES
‧
‧
‧
‧
‧
‧
‧
EN61000-3-2 class A and D compliant
Power factor 0.98 typical
Very compact size, 3″×5″×1.2″
Overvoltage protections
Short circuit protections
Remote sense
Compliant with RoHS requirements
INPUT SPECIFICATIONS
Safety Standard Approvals:
Input voltage:
Input frequency:
Input current:
90 to 264VAC
47 to 63Hz
2.1A( rms) max. for 115VAC
1.1A( rms) max. for 230VAC
Earth leakage current: 0.3mA max. @ 115VAC, 60Hz
(Touch current)
0.6mA max. @ 230VAC, 50Hz
UL 60950-1
CSA C22.2 No. 60950-1
TÜV EN60950-1
OUTPUT SPECIFICATIONS
Output voltage/current: See Rating Chart
Ripple and noise:
2% peak to peak on 5.1V model
1% peak to peak on other
models.
Overvoltage protection: Provided on output set at
112–132% of its nominal output
voltage
Overcurrent protection: Protected to short circuit
conditions
Temperature coefficient:All outputs ± 0.04%/ºC maximum
Transient response:
Maximum excursion of 4% or
better on all models; recovering
to 1% of final value within 500µs
after a 25% step load change
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
Cooling:
-10ºC to +60ºC
-40ºC to +85ºC
5% to 95% non-condensing
Derate from 100% at +40ºC
linearly to 50% at +60ºC
10 CFM total forced air from two
40mm diameter fans or the like
is required and provided by user
GENERAL SPECIFICATIONS
Switching frequency: 110KHz ±15KHz
Power factor:
0.98 typical
Efficiency:
72% typical on 5.1V output,
76% typical on other outputs
Hold-up time:
15 msec minimum at 115VAC
Line regulation:
±0.5% maximum at full load
Inrush current:
35 amps @ 115VAC or 70 amps
@ 230VAC at 25ºC cold start
Withstand voltage:
3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
200,000 hours minimum
EMC Performance (EN55024)
EN55022:
FCC Part 15
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
Class B conducted, class A radiated
Class B conducted, class A radiated
Class B conducted, class A radiated
Harmonic distortion, class A and D
Line flicker
ESD, ±8KV air and ±4KV contact
Radiated immunity, 3V/m
Fast transient/burst, ±1KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 1A/m
Voltage dips, 30% reduction for 500ms
and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com
UNIVERSAL INPUT
TFC130 SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
Output
Product No.
Vnom.
Imin.
Imax.
Tol.
Maximum
Output Power
TFC130-S5.1
TFC130-S12
TFC130-S15
TFC130-S18
TFC130-S24
TFC130-S30
TFC130-S36
TFC130-S48
5.1V
12V
15V
18V
24V
30V
36V
48V
0.7A
0.5A
0.5A
0.5A
0.4A
0.4A
0.3A
0.3A
25.5A
10.8A
8.7A
7.2A
5.4A
4.3A
3.7A
2.7A
2%
2%
2%
2%
2%
2%
2%
2%
130W
130W
130W
130W
130W
130W
130W
130W
NOTES:
1.
130 watts maximum at 10 CFM forced air cooling.
2.
Ripple and noise is measured peak to peak across a 20MHz bandwidth by using a 12
inch twisted pair terminated with a 10uF tantalum capacitor in parallel with a 0.1µF
ceramic capacitor.
3.
Suffix codes for over-temperature protection function and output connector
are as follows. TFC130-X1 X2 X3, where “X1” is the product code from the
above table, “X2” is the over-temperature protection function
(Blank=without over-temperature protection, W=with over-temperature
protection), “X3” is output connector (Blank=Molex KK type, T=miniature
terminal blocks), e.g. TFC130-S24-W (24V output voltage, with
over-temperature protection, Molex KK type).
MECHANICAL SPECIFICATIONS
NOTES:
1. Dimensions shown in inch [mm]
2. Tolerance 0.02 [0.5] maximum
3. Connector P1 mates with Molex housing
09-50-3031 and Molex 2878 series crimp
terminal.
4. Molex KK type connectors:
Connector P3 mates with Molex housing
09-50-3101 and Molex 2878 series crimp
terminal.
5. Miniature terminal blocks: Connector P3 are
suitable for AWG#18~AWG#12 electric wires.
6. Connector P2, P4 mates with Molex
housing 22- 01-1023 and Molex 40445
series crimp terminal.
7. Weight: 0.38 kgs (0.84 lbs.) approx.
8. Potentiometer (VR1) is for output voltage
adjustment.
PIN CHART
CONN
P1
P2
Void Void
1
Product No.
TFC130-S5.1
TFC130-S15
TFC130-S24
TFC130-S36
TFC130-S12
TFC130-S18
TFC130-S30
TFC130-S48
2
3
1
2
AC
AC
Void
+SENSE -SENSE
LIVE
NEUTRAL
1
2
3
4
3
4
P3
Void Void
5
OUTPUT
6
P4
7
8
7
8
Void Void
9
RETURN
10
1
2
FAN
RET.
(12V)
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com