TOTAL-POWER Q-60

TOTAL POWER INT'L
Q-60
60W Quad Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 35KHz
2 years warranty
SPECIFICATION
Q-60B
MODEL
OUTPUT
INPUT
Q-60C
Q-60D
DC VOLTAGE
5V
12V
-5V
-12V
5V
15V
-5V
-15V
5V
12V
24V
-12V
RATED CURRENT
5.5A
2A
0.5A
0.5A
5.5A
1.5A
0.5A
0.5A
4A
1A
1A
0.5A
CURRENT RANGE
0.5 ~ 8A
0.1 ~ 3A
0 ~ 1A
0 ~ 1A
0.5 ~ 8A
0.1 ~ 3A
0 ~ 1A
0 ~ 1A
0.5 ~ 8A
0.1 ~ 3A
0.1 ~ 1.5A 0 ~ 1A
RATED POWER
60W
60W
62W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 150mVp-p 120mVp-p
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
VOLTAGE ADJ. RANGE
6.0%
5.0%
2.0%
+8,-4%
+8,-4%
5.0%
6.0%
5.0%
2.0%
5.0%
5.0%
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
1.0%
0.5%
0.5%
0.5%
2.0%
0.5%
0.5%
0.5%
1.0%
2.0%
0.5%
LOAD REGULATION
0.5%
4.0%
1.0%
1.0%
0.5%
4.0%
1.0%
1.0%
0.5%
4.0%
4.0%
1.0%
SETUP, RISE, HOLD TIME
800ms, 20ms, 60ms/230VAC
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
1600ms, 20ms, 12ms/115VAC at full load
120 ~ 370VDC
EFFICIENCY (Typ.)
70%
AC CURRENT
INRUSH CURRENT (max.)
2A/115VAC
0.8A/230VAC
COLD START 18A/115VAC
36A/230VAC
72%
LEAKAGE CURRENT
<1mA / 240VAC
OVER LOAD
105 ~ 150%/115VAC rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
75%
5V: 5.75 ~ 6.75VDC
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
0.03%/
, 10 ~ 95% RH
(0 ~ 50
) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
EMS IMMUNITY
MTBF
284.8K hrs min. MIL-HDBK-217F (25 )
DIMENSION
OTHERS
159*97*38mm (L*W*H)
0.55Kg; 24pcs/13.2Kg/0.75CUFT
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
Q-60
60W Quad Output Switching Power Supply
Mechanical Specification
Case No. 901
4.5
series
Unit:mm
3.5
7
152.5
1
8.25
2
65
3
5
6
2 -M
97
84.5
4
3
7
7
8
3 .5
4.5
24
78
159
6.5
9
37.5
M3
18
3 .5
3-
3.5
18.5
9
9
150
117
22
Terminal Pin. No Assignment
Assignment
AC/L
AC/N
FG
Pin No.
1
2
3
Pin No.
4
5
6
Assignment
DC OUTPUT -V1
DC OUTPUT -V2
DC OUTPUT +V2
Pin No.
7
8
Assignment
DC OUTPUT COM
DC OUTPUT +V1
Derating Curve
Static Characteristics
Ta=25
100
OUTPUT VOLTAGE (V)
12
80
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
50
45
AMBIENT TEMPERATURE ( )
60 (VERTICAL)
55 (HORIZONTAL)
11
+12V
5.2
5.0
4.8
-5V
-12V
+5V
300
250
+5V
+12V
-5V
200
10
4.6
150
9
4.4
100
8
4.2
50
7
4.0
25
-12V
60
80
100
120
140
160
180
200
INPUT VOLTAGE (V) 60Hz
220
240
260
OUTPUT RIPPLE (mVp-p)
13