SP-300 series - Total Power International

TOTAL POWER INT'L
SP-300
300W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections:Short circuit/Over load/Over voltage/Over temperature
Forced air cooling by built-in DC fan
Built-in cooling Fan ON-OFF control
Fixed switching frequency at 110KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
SP-300-5
SP-300-7.5
SP-300-12
SP-300-13.5
SP-300-15
SP-300-24
SP-300-27
DC VOLTAGE
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
50A
34A
24A
21A
19A
12.5A
11A
6.25A
CURRENT RANGE
0 ~ 50A
0 ~ 34A
0 ~ 24A
0 ~ 21A
0 ~ 19A
0 ~ 12.5A
0 ~ 11A
0 ~ 6.5A
RATED POWER
250W
255W
288W
285W
285W
300W
297W
300W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.7V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
LOAD REGULATION
INPUT
PROTECTION
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
240mVp-p
6 ~ 9V
2.0%
10 ~ 13.2V
1.0%
12 ~ 15V
1.0%
13.5 ~ 18V
1.0%
20 ~ 26.4V
1.0%
26 ~ 32V
41 ~ 56V
0.3%
0.3%
0.3%
0.2%
0.2%
0.2%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
VOLTAGE RANGE
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.95/230VAC
EFFICIENCY(Typ.)
75%
80%
AC CURRENT
INRUSH CURRENT(max.)
4A/115VAC
18A/115VAC
2A/230VAC
36A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVER LOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
1.0%
0.5%
1500ms, 50ms, 20ms at full load
FAN CONTROL O.T.P.
1.0%
0.5%
SETUP, RISE, HOLD TIME
OVER VOLTAGE
SP-300-48
124 ~ 370VDC
PF>0.95/115VAC at full load
83%
83%
83%
85%
5.75 ~ 6.75V 9.4 ~ 10.9V
13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V
27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
RTH1 or RTH2 50 FAN ON,
5 FAN OFF, 70 output shutdown
-10 ~ +50 (Refer to output load derating curve)
86%
85%
33.7 ~ 39.2V
57.6 ~ 67.2V
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min. each along X, Y, Z axes
UL1950, TUV EN60950 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
ISOLATION
RESISTANCE
SAFETY &
Compliance
to EN55022 (CISPR22) Class B
EMI
CONDUCTION
&
RADIATION
EMC
(Note 4)
OTHERS
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204 Light industry level, criteria A
168.7K hrs min. MIL-HDBK-217F (25
215*115*50mm (L*W*H)
1.18Kg; 12pcs/14.2Kg/0.98CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
TOTAL POWER INT'L
SP-300
300W Single Output with PFC Function
Mechanical Specification
Case No. 912
series
Unit:mm
117.5
27.5
150
32.5
117.5
47.5
36.5
LED
+V ADJ.
9
8
5
115
50
95
9.5
135
7
6
4-M4 L=5mm
8
32.5
3
5-M3 L=3mm
2
16
10
1
50.5
4
15
Air flow
direction
215
CL
25
Terminal pin number assignment :
Pin No.
1
2
3
50
150
32.5
4-M4 L=6mm
Pin No.
Assignment
4~6
DC OUTPUT -V
7~9
DC OUTPUT +V
Assignment
AC/L
AC/N
FG
Derating Curve
Output Derating VS Input Voltage
Ta=25
24~48V
100
100
12~15V
90
80
80
LOAD (%)
LOAD (%)
70
5,7.5V
60
40
20
-10
0
10
20
30
40
AMBIENT TEMPERATURE (
45
)
50
(HORIZONTAL)
60
50
40
88
115
135
155
INPUT VOLTAGE (VAC) 60Hz
230 264