H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 150 WATTS INTERNAL SWITCHING POWER SUPPLIES HVP149 SERIES FEATURES: ACCOMMODATE UNIVERSAL AC SOURCES MEET IEC 61000-3-2 HARMONIC CORRECTION DUAL CONVERTER ARCHITECTURE +5V STAND-BY GREEN POWER MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB. 22 & FCC CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: V-M (Molex 5273) connector. Input Frequency: 47-63Hz. Inrush Current: Typ. ≤ 30.6A@230Vac. Input Current: 2.0A @115Vac, 0.96A @230Vac. Dielectric Withstand: Meet IEC 60950-1. EMI: Meet CISPR PUB. 22 & FCC Class B. Hold-up Time: Typ. 20mS @115Vac & 230Vac. Power Fail Signal: Installed. DC OK Signal: Installed in two main outputs. Remote Inhibit: Installed. Enable active low. Power Factor & Harmonic Correction: Meet IEC 61000-3-2, PF typ.0.99@ full load. Over Temperature Protection: By thermostat. Earth Leakage: Less than 0.75mA. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: B-S, V-M (Molex 5273), X-M (Molex 5268) connectors. Output Wattage: Typ. 150W with 30 cfm forced air cooling. Line Regulation: Typ. 0.1%. Load Regulation: Main VO1 & Aux. VO2 typ. ± 1-1.5%. Main VO3 & Aux. VO4 typ. ± 5.0%. Noise & Ripple: Typ. 1.0% peak to peak. OVP: Installed in VO1, VO2 & VO3 (Latch). Remote Sensing: Installed in O/P VO1 & VO2. Adjustability: Available at VO1, VO2 and VO3. Load Sharing: Active current sharing circuit available at VO1 & VO2 rail. Overload Protection (OLP): Fully protected against output overload and short circuit. Consult the factory for the OLP setting. GENERAL SPECIFICATION Efficiency: Typ. 70-73.7%. Switching Frequency: Fixed frequency at 70K Hz. Circuit Topology: Dual converter architecture. 1st, forward circuit for VO1 & VO2 rails. 2nd, fixed-frequency flyback circuit for VO3 & VO4 rails. Transient Response: Output voltage returns in less than 1mS following a 25% load change. Safety Standard: UL 60950-1/EN 60950-1 Class I. Power Density: 3.0 Watts / Cubic Inch. Operating Temperature: 0 to +50°C under forced air cooling for half load. Storage Temperature: -55 to +85°C. Temperature Coefficient: 0 to +70°C (after 15 minutes warm-up) typ. ±0.02-0.05%/°C. Cooling: 25-30 cfm airflow is required to deliver the full power. 150W. Construction: U-bracket construction format. Industrial Grade. Note: Due to requests in market and advances in technology, specifications subject to change without notification. For the details of safety approval, please consult the factory. -51- OUTPUT VOLTAGE / CURRENT RATINGS CHART SINGLE OUTPUT(Under forced air cooling) MODEL NO. HVP149-S033350 HVP149-S050300 HVP149-S120150 HVP149-S240075 HVP149-S480375 DUAL OUTPUT(Under forced air cooling) MAIN VO1 @★#≡ Typ. Volt. 35.00A +3.3V 30.00A +5.0V 15.00A +12.0V 7.50A +24.0V 3.75A +48.0V MAIN VO1 @★#≡ Typ. Volt. 30A +5.0V 30A +5.0V 30A +5.0V 30A +5.0V 30A +5.0V 30A +3.3V 30A +3.3V 30A +3.3V 30A +3.3V MODEL NO. HVP149-20 HVP149-21 HVP149-22 HVP149-23 HVP149-290A HVP149-290B HVP149-291 HVP149-292 HVP149-293 AUX. VO2 @★▲#≡ Typ. Volt. 10A +5.0V 5A +12.0V 5A +15.0V 3A +24.0V 15A +3.3V 8A +5.0V 5A +12.0V 4A +15.0V 3A +24.0V TRIPLE OUTPUT(Under forced air cooling) MAIN VO1 @★#≡ Typ. Volt. 30.0A +5.0V 30.0A +5.0V 17.5A +5.0V 30.0A +5.0V 30.0A +5.0V 30.0A +5.0V 30.0A +3.3V 30.0A +5.0V 30.0A +3.3V MODEL NO. HVP149-30 HVP149-31 HVP149-T050IM HVP149-32 HVP149-33 HVP149-390A HVP149-390B HVP149-391A HVP149-391B AUX. VO2 @★#≡▲ Typ. Volt. 4.0A +12.0V 4.0A +12.0V 4.0A +12.0V 2.5A +24.0V 4.0A +15.0V 12.0A +3.3V 8.0A +5.0V 12.0A +3.3V 8.0A +5.0V MAIN ±VO3 @★◇ Typ. Volt. 3.0A 12.0V 6.0A 5.0V 2.0A 24.0V 3.0A 12.0V 3.0A 15.0V 3.0A 12.0V 3.0A 12.0V 3.0A 15.0V 3.0A 15.0V AUX. VO2 @★#≡▲ Typ. Volt. 8.0A +12.0V 8.0A +12.0V 8.0A +12.0V 4.0A +24.0V 6.0A +15.0V 15.0A +3.3V 15.0A +5.0V 15.0A +3.3V 15.0A +5.0V 15.0A +3.3V MAIN ±VO3@ ★◇‖ Typ. Volt. 2.0A 12.0V 4.0A 5.0V 3.0A 12.0V 2.0A 12.0V 2.0A 12.0V 2.0A 12.0V 2.0A 12.0V 1.5A 15.0V 1.5A 15.0V 4.0A 12.0V QUAD OUTPUT(Under forced air cooling) MAIN VO1 @★#≡ Typ. Volt. 30A +5.0V 30A +5.0V 30A +5.0V 30A +5.0V 30A +5.0V 30A +5.0V 30A +3.3V 30A +5.0V 30A +3.3V 30A +2.5V MODEL NO. HVP149-40 HVP149-41 HVP149-Q050IIE HVP149-42 HVP149-43 HVP149-490A HVP149-490B HVP149-491A HVP149-491B HVP149-Q025DIE AUX. ±VO4 ◇(●or‖) Typ. Volt. 2.0A 12.0V 3.0A 5.0V 2.0A 5.0V 2.0A 12.0V 1.5A 15.0V 2.0A 12.0V 2.0A 12.0V 1.5A 15.0V 1.5A 15.0V 2.0A 5.0V Symbol: "★" OVP built-in. "@" Adjustable. "◇" Floating but not isolated output. "●" Installed with Post Regulator (P.R.). "#" Remote sensing. "▲" Installed with magnetic amplifier. "±" Positive or Negative selectable (factory set). "≡" Active circuit current sharing. "‖" Double Feedback. Remark: VO1 andVO2 total continual output current ≦30A. VO3 and VO4 total continual output current ≦5A. Max. total output power: 150W. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 960.5g (33.88 Oz) INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT SINGLE/DUAL/ TRIPLE/ QUAD OUTPUT ASSORTED SIGNALS ASSIGNMENT ACLINE ACNEUTRAL ACGROUND +VO1 VO2 DCCOM VO3 -VO3 VO4 -VO4 DC-COM ENABLE POWER FAIL DC-OK +5V S. B. VO2 ≡ VO2+S VO1 ≡ VO1/VO2 –S VO1 +S CNTR & PIN# P1-L P1-N P1-G P2-2 P2-3 P2-1 P3-1,2 P3-3,4 P3-5 P3-6 P4-1 P4-2 P4-3 P4-4 P4-5 P4-6 P4-7 P4-8 P4-9 P4-10 Mating connector P1 & P3: Molex 5195 or 5239 series, P4: Molex 5264 series or equivalent. -52-