HITRON HVP149

H HiTRON
UNIVERSAL INPUT HARMONIC CORRECTION
AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 150 WATTS
INTERNAL SWITCHING POWER SUPPLIES HVP149 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC 61000-3-2 HARMONIC CORRECTION
DUAL CONVERTER ARCHITECTURE
+5V STAND-BY GREEN POWER
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: V-M (Molex 5273) connector.
Input Frequency: 47-63Hz.
Inrush Current: Typ. ≤ 30.6A@230Vac.
Input Current: 2.0A @115Vac, 0.96A @230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time: Typ. 20mS @115Vac & 230Vac.
Power Fail Signal: Installed.
DC OK Signal: Installed in two main outputs.
Remote Inhibit: Installed. Enable active low.
Power Factor & Harmonic Correction:
Meet IEC 61000-3-2, PF typ.0.99@ full load.
Over Temperature Protection: By thermostat.
Earth Leakage: Less than 0.75mA.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: B-S, V-M (Molex 5273),
X-M (Molex 5268) connectors.
Output Wattage: Typ. 150W with 30 cfm forced
air cooling.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 & Aux. VO2 typ. ± 1-1.5%.
Main VO3 & Aux. VO4 typ. ± 5.0%.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Installed in VO1, VO2 & VO3 (Latch).
Remote Sensing: Installed in O/P VO1 & VO2.
Adjustability: Available at VO1, VO2 and VO3.
Load Sharing: Active current sharing circuit available at
VO1 & VO2 rail.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Consult the factory for the OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 70-73.7%.
Switching Frequency: Fixed frequency at 70K Hz.
Circuit Topology: Dual converter architecture.
1st, forward circuit for VO1 & VO2 rails.
2nd, fixed-frequency flyback circuit for VO3 & VO4 rails.
Transient Response: Output voltage returns in less
than 1mS following a 25% load change.
Safety Standard: UL 60950-1/EN 60950-1 Class I.
Power Density: 3.0 Watts / Cubic Inch.
Operating Temperature: 0 to +50°C under forced air
cooling for half load.
Storage Temperature: -55 to +85°C.
Temperature Coefficient: 0 to +70°C (after 15 minutes
warm-up) typ. ±0.02-0.05%/°C.
Cooling: 25-30 cfm airflow is required to deliver the full
power. 150W.
Construction: U-bracket construction format.
Industrial Grade.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
-51-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
SINGLE OUTPUT(Under forced air cooling)
MODEL NO.
HVP149-S033350
HVP149-S050300
HVP149-S120150
HVP149-S240075
HVP149-S480375
DUAL OUTPUT(Under forced air cooling)
MAIN VO1 @★#≡
Typ.
Volt.
35.00A
+3.3V
30.00A
+5.0V
15.00A
+12.0V
7.50A
+24.0V
3.75A
+48.0V
MAIN VO1 @★#≡
Typ.
Volt.
30A
+5.0V
30A
+5.0V
30A
+5.0V
30A
+5.0V
30A
+5.0V
30A
+3.3V
30A
+3.3V
30A
+3.3V
30A
+3.3V
MODEL NO.
HVP149-20
HVP149-21
HVP149-22
HVP149-23
HVP149-290A
HVP149-290B
HVP149-291
HVP149-292
HVP149-293
AUX. VO2 @★▲#≡
Typ.
Volt.
10A
+5.0V
5A
+12.0V
5A
+15.0V
3A
+24.0V
15A
+3.3V
8A
+5.0V
5A
+12.0V
4A
+15.0V
3A
+24.0V
TRIPLE OUTPUT(Under forced air cooling)
MAIN VO1 @★#≡
Typ.
Volt.
30.0A
+5.0V
30.0A
+5.0V
17.5A
+5.0V
30.0A
+5.0V
30.0A
+5.0V
30.0A
+5.0V
30.0A
+3.3V
30.0A
+5.0V
30.0A
+3.3V
MODEL NO.
HVP149-30
HVP149-31
HVP149-T050IM
HVP149-32
HVP149-33
HVP149-390A
HVP149-390B
HVP149-391A
HVP149-391B
AUX. VO2 @★#≡▲
Typ.
Volt.
4.0A
+12.0V
4.0A
+12.0V
4.0A
+12.0V
2.5A
+24.0V
4.0A
+15.0V
12.0A
+3.3V
8.0A
+5.0V
12.0A
+3.3V
8.0A
+5.0V
MAIN ±VO3 @★◇
Typ.
Volt.
3.0A
12.0V
6.0A
5.0V
2.0A
24.0V
3.0A
12.0V
3.0A
15.0V
3.0A
12.0V
3.0A
12.0V
3.0A
15.0V
3.0A
15.0V
AUX. VO2 @★#≡▲
Typ.
Volt.
8.0A
+12.0V
8.0A
+12.0V
8.0A
+12.0V
4.0A
+24.0V
6.0A
+15.0V
15.0A
+3.3V
15.0A
+5.0V
15.0A
+3.3V
15.0A
+5.0V
15.0A
+3.3V
MAIN ±VO3@ ★◇‖
Typ.
Volt.
2.0A
12.0V
4.0A
5.0V
3.0A
12.0V
2.0A
12.0V
2.0A
12.0V
2.0A
12.0V
2.0A
12.0V
1.5A
15.0V
1.5A
15.0V
4.0A
12.0V
QUAD OUTPUT(Under forced air cooling)
MAIN VO1 @★#≡
Typ.
Volt.
30A
+5.0V
30A
+5.0V
30A
+5.0V
30A
+5.0V
30A
+5.0V
30A
+5.0V
30A
+3.3V
30A
+5.0V
30A
+3.3V
30A
+2.5V
MODEL NO.
HVP149-40
HVP149-41
HVP149-Q050IIE
HVP149-42
HVP149-43
HVP149-490A
HVP149-490B
HVP149-491A
HVP149-491B
HVP149-Q025DIE
AUX. ±VO4 ◇(●or‖)
Typ.
Volt.
2.0A
12.0V
3.0A
5.0V
2.0A
5.0V
2.0A
12.0V
1.5A
15.0V
2.0A
12.0V
2.0A
12.0V
1.5A
15.0V
1.5A
15.0V
2.0A
5.0V
Symbol: "★" OVP built-in. "@" Adjustable. "◇" Floating but not isolated output. "●" Installed with Post Regulator (P.R.). "#" Remote sensing.
"▲" Installed with magnetic amplifier. "±" Positive or Negative selectable (factory set). "≡" Active circuit current sharing. "‖" Double Feedback.
Remark: VO1 andVO2 total continual output current ≦30A. VO3 and VO4 total continual output current ≦5A. Max. total output power: 150W.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 960.5g (33.88 Oz)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT
SINGLE/DUAL/ TRIPLE/ QUAD OUTPUT
ASSORTED SIGNALS
ASSIGNMENT
ACLINE
ACNEUTRAL
ACGROUND
+VO1
VO2
DCCOM
VO3
-VO3
VO4
-VO4
DC-COM
ENABLE
POWER FAIL
DC-OK
+5V S. B.
VO2 ≡
VO2+S
VO1 ≡
VO1/VO2 –S
VO1 +S
CNTR & PIN#
P1-L
P1-N
P1-G
P2-2
P2-3
P2-1
P3-1,2
P3-3,4
P3-5
P3-6
P4-1
P4-2
P4-3
P4-4
P4-5
P4-6
P4-7
P4-8
P4-9
P4-10
Mating connector P1 & P3: Molex 5195 or 5239 series, P4: Molex 5264 series or equivalent.
-52-