hitron-e.com

H HiTRON
UNIVERSAL INPUT AC-DC INTERNAL OPEN FRAME
SWITCHING POWER SUPPLIES 60-62 WATTS SINGLE,
DUAL & TRIPLE OUTPUT HVI63 SERIES
FEATURES:
 ACCOMMODATE UNIVERSAL AC INPUT
 COMPACT 4”x2”x1”PCB FORMAT
 MEET UNIVERSAL SAFETY STANDARDS
 EMI MEET CISPR PUB. 22 & FCC CLASS B
 CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Range typical 90-264Vac.
Rating 100 to 240Vac.
Input Connector: Molex connector or equivalent
Input Frequency: 47-63Hz.
Inrush Current: ≤12.0A rms at cold start at 230Vac.
Input Current: Typical 0.9A at 115Vac,
Typical 0.435A at 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time: Typical 11.2mS at 115Vac,
Typical 72.mS at 230Vac.
Leakage Current: Less than 0.42mA at 230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: Molex connector or equivalent.
Output Wattage: Typical 60-62 watts.
Line Regulation: Typical 0.1%.
Load Regulation: Main VO1 typical ±1.0%.
Aux. VO2 typical ±3-8.0%.
Aux. VO3 typical ±3.0%.
Noise & Ripple: Typical 1.0% peak to peak.
OVP: Built-in at main output VO1(Latch).
Adjustability: Not available.
Overload Protection (OLP):
Fully protected against outputs overload and short circuit.
Typical OLP set at 105-120% of rating output power.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typical 80-89.5%. (Various with output voltage)
Switching Frequency: 130KHz or 70KHz.
Circuit Topology: Fixed frequency forward circuit for triple
output and 5V/3.3V of single output.
Fixed Frequency Flyback circuit for
high voltage of single output.
Transient Response: Output voltage returns in less than
0.5mS following a 50% load change.
Safety Standard: Meet IEC 60950-1 Class I.
Power Density: 7.5-7.7Watts / Cubic Inch.
Operating Temperature: 0 to +50 °C under forced air flow
for full load. Derate by 1.3W/°C
from 40°C to 50°C.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typical 0.04%/°C.
Cooling: At least 5CFM direct forward air flow is required to
achieve full rating power.
Construction: 4”x2”x1” PCB format.
NOTE: (1)All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2)Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory
-65-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
DUAL OUTPUT
MAIN VO1 ★
Min. Typ.
Volt.
Max.
MODEL NO.
Peak
HVI63-S033100 0.2A 10.00A
3.3V 10.00A 12.0A
HVI63-S050100 0.2A 10.00A
5.0V 10.00A 12.0A
HVI63-S120050 0.0A 5.00A 12.0V
5.00A
6.0A
HVI63-S150040 0.0A 4.00A 15.0V
4.00A
5.0A
HVI63-S240025 0.0A 2.50A 24.0V
2.50A
3.0A
HVI63-S480125 0.0A 1.25A 48.0V
1.25A
1.3A
HVI63-D051I
MAIN +VO1 ★
Min.
Typ.
0.5A
4.0A
AUX. +VO2 ■
Volt.
Min.
Typ.
Volt.
+5.1V
0.2A
3.5A
+12V
TRIPLE OUTPUT
MODEL NO.
MAIN +VO1 ★
Min.
Typ.
HVI63-T050II
0.5A
HVI63-T050MI
AUX. +VO2 ■
AUX. -VO3 ■
Max.
Peak
Min.
Typ.
Volt.
Max.
Peak
Min.
Typ.
Volt.
Max.
Peak
6.0A +5.0V
8A
10A
0.1A
2.2A
+12V
3.0A
4A
0A
0.5A
-12V
0.5A
1A
0.5A
6.0A +5.0V
8A
10A
0.1A
1.1A
+24V
1.5A
2A
0A
0.5A
-12V
0.5A
1A
HVI63-T050KK 0.5A
6.0A +5.0V
8A
10A
0.1A
1.8A
+15V
2.5A
3A
0A
0.5A
-15V
0.5A
1A
0.5A
8.0A +3.3V
8A
10A
0.1A
3.0A
+ 5V
3.0A
4A
0A
0.5A
-12V
0.5A
1A
HVI63-T033EI
Symbol: "★" OVP built-in.
Volt.
"■" Couple common choke.
MECHANICAL DIMENSIONS: MM [INCHES]
SINGLE OUTPUT
WEIGHT: 121g (4.27 Oz.)
DUAL/TRIPLE OUTPUT
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT
ASSIGNMENT
AC-L
AC-N
AC-G
P1-L
P1-N
G
CNTR/PIN#
Mating connector: P1,2 Molex # 5195 or 5239 series.
SINGLE OUTPUT
VO1
DC COM
P2-1,2
P2-3,4
-66-
VO1
P2-1,2
DUAL/TRIPLE OUTPUT
VO2
VO3
P2-6
P2-5
DC COM
P2-3,4