8 Bit Microcontroller TLCS-870/C Series TMP86CM23AUG The information contained herein is subject to change without notice. 021023_D TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc. 021023_A The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer's own risk. 021023_B The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. 060106_Q The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patents or other rights of TOSHIBA or the third parties. 070122_C The products described in this document are subject to foreign exchange and foreign trade control laws. 060925_E For a discussion of how the reliability of microcontrollers can be predicted, please refer to Section 1.3 of the chapter entitled Quality and Reliability Assurance/Handling Precautions. 030619_S © 2007 TOSHIBA CORPORATION All Rights Reserved Revision History Date Revision 2005/9/9 1 First Release 2005/10/3 2 Contents Revised 2006/8/28 3 Contents Revised 2007/10/16 4 Contents Revised Table of Contents TMP86CM23AUG 1.1 1.2 1.3 1.4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 3 4 5 2. Operational Description 2.1 CPU Core Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.1.1 2.1.2 2.1.3 Memory Address Map............................................................................................................................... 9 Program Memory (MaskROM).................................................................................................................. 9 Data Memory (RAM) ............................................................................................................................... 10 2.2.1 2.2.2 Clock Generator...................................................................................................................................... 10 Timing Generator .................................................................................................................................... 12 2.2 System Clock Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.2.2.1 2.2.2.2 Configuration of timing generator Machine cycle 2.2.3.1 2.2.3.2 2.2.3.3 Single-clock mode Dual-clock mode STOP mode 2.2.4.1 2.2.4.2 2.2.4.3 2.2.4.4 STOP mode IDLE1/2 mode and SLEEP1/2 mode IDLE0 and SLEEP0 modes (IDLE0, SLEEP0) SLOW mode 2.2.3 2.2.4 2.3 Operation Mode Control Circuit .............................................................................................................. 13 Operating Mode Control ......................................................................................................................... 18 Reset Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2.3.1 2.3.2 2.3.3 2.3.4 External Reset Input ............................................................................................................................... 31 Address trap reset .................................................................................................................................. 32 Watchdog timer reset.............................................................................................................................. 32 System clock reset.................................................................................................................................. 32 3. Interrupt Control Circuit 3.1 3.2 Interrupt latches (IL19 to IL2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Interrupt enable register (EIR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 3.2.1 3.2.2 Interrupt master enable flag (IMF) .......................................................................................................... 36 Individual interrupt enable flags (EF19 to EF4) ...................................................................................... 37 3.3.1 3.3.2 Interrupt acceptance processing is packaged as follows........................................................................ 39 Saving/restoring general-purpose registers ............................................................................................ 40 Note 3: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 3.3 Interrupt Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 3.3.2.1 3.3.2.2 Using PUSH and POP instructions Using data transfer instructions 3.3.3 Interrupt return ........................................................................................................................................ 41 3.4.1 3.4.2 Address error detection .......................................................................................................................... 42 Debugging .............................................................................................................................................. 42 3.4 Software Interrupt (INTSW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 i 3.5 3.6 3.7 Undefined Instruction Interrupt (INTUNDEF). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Address Trap Interrupt (INTATRAP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 External Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 4. Special Function Register (SFR) 4.1 4.2 SFR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 DBR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 5. I/O Ports 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Port P1 (P17 to P10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P2 (P22 to P20) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P3 (P37 to P30) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P5 (P57 to P50) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P6 (P67 to P60) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P7 (P77 to P70) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P8 (P87 to P80) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 52 53 55 57 60 62 6. Time Base Timer (TBT) 6.1 Time Base Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 6.1.1 6.1.2 6.1.3 Configuration .......................................................................................................................................... 65 Control .................................................................................................................................................... 65 Function .................................................................................................................................................. 66 6.2.1 6.2.2 Configuration .......................................................................................................................................... 67 Control .................................................................................................................................................... 67 6.2 Divider Output (DVO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 7. Watchdog Timer (WDT) 7.1 7.2 Watchdog Timer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Watchdog Timer Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 7.2.1 7.2.2 7.2.3 7.2.4 7.2.5 Malfunction Detection Methods Using the Watchdog Timer ................................................................... Watchdog Timer Enable ......................................................................................................................... Watchdog Timer Disable ........................................................................................................................ Watchdog Timer Interrupt (INTWDT)...................................................................................................... Watchdog Timer Reset ........................................................................................................................... 70 71 72 72 73 7.3.1 7.3.2 7.3.3 7.3.4 Selection of Address Trap in Internal RAM (ATAS) ................................................................................ Selection of Operation at Address Trap (ATOUT) .................................................................................. Address Trap Interrupt (INTATRAP)....................................................................................................... Address Trap Reset ................................................................................................................................ 74 74 74 75 7.3 Address Trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 8. 18-Bit Timer/Counter (TC1) 8.1 8.2 8.3 ii Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 8.3.1 8.3.2 8.3.3 8.3.4 Timer mode............................................................................................................................................. 81 Event Counter mode ............................................................................................................................... 82 Pulse Width Measurement mode............................................................................................................ 83 Frequency Measurement mode .............................................................................................................. 84 9. 8-Bit TimerCounter (TC3, TC4) 9.1 9.2 9.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 TimerCounter Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 9.3.1 9.3.2 9.3.3 9.3.4 9.3.5 9.3.6 9.3.7 9.3.8 9.3.9 8-Bit Timer Mode (TC3 and 4) ................................................................................................................ 93 8-Bit Event Counter Mode (TC3, 4) ........................................................................................................ 94 8-Bit Programmable Divider Output (PDO) Mode (TC3, 4)..................................................................... 94 8-Bit Pulse Width Modulation (PWM) Output Mode (TC3, 4).................................................................. 97 16-Bit Timer Mode (TC3 and 4) .............................................................................................................. 99 16-Bit Event Counter Mode (TC3 and 4) .............................................................................................. 100 16-Bit Pulse Width Modulation (PWM) Output Mode (TC3 and 4)........................................................ 100 16-Bit Programmable Pulse Generate (PPG) Output Mode (TC3 and 4) ............................................. 103 Warm-Up Counter Mode....................................................................................................................... 105 9.3.9.1 9.3.9.2 Low-Frequency Warm-up Counter Mode (NORMAL1 → NORMAL2 → SLOW2 → SLOW1) High-Frequency Warm-Up Counter Mode (SLOW1 → SLOW2 → NORMAL2 → NORMAL1) 10. 8-Bit TimerCounter (TC5, TC6) 10.1 10.2 10.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 TimerCounter Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 10.3.1 10.3.2 10.3.3 10.3.4 10.3.5 10.3.6 10.3.7 10.3.8 10.3.9 8-Bit Timer Mode (TC5 and 6) ............................................................................................................ 8-Bit Event Counter Mode (TC5, 6) .................................................................................................... 8-Bit Programmable Divider Output (PDO) Mode (TC5, 6)................................................................. 8-Bit Pulse Width Modulation (PWM) Output Mode (TC5, 6).............................................................. 16-Bit Timer Mode (TC5 and 6) .......................................................................................................... 16-Bit Event Counter Mode (TC5 and 6) ............................................................................................ 16-Bit Pulse Width Modulation (PWM) Output Mode (TC5 and 6)...................................................... 16-Bit Programmable Pulse Generate (PPG) Output Mode (TC5 and 6) ........................................... Warm-Up Counter Mode..................................................................................................................... 10.3.9.1 10.3.9.2 113 114 114 117 119 120 120 123 125 Low-Frequency Warm-up Counter Mode (NORMAL1 → NORMAL2 → SLOW2 → SLOW1) High-Frequency Warm-Up Counter Mode (SLOW1 → SLOW2 → NORMAL2 → NORMAL1) 11. Asynchronous Serial interface (UART ) 11.1 11.2 11.3 11.4 11.5 11.6 11.7 11.8 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transfer Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transfer Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Sampling Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STOP Bit Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit/Receive Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.8.1 11.8.2 11.9 127 128 130 131 131 132 132 132 Data Transmit Operation .................................................................................................................... 132 Data Receive Operation ..................................................................................................................... 132 Status Flag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 iii 11.9.1 11.9.2 11.9.3 11.9.4 11.9.5 11.9.6 Parity Error.......................................................................................................................................... Framing Error...................................................................................................................................... Overrun Error ...................................................................................................................................... Receive Data Buffer Full..................................................................................................................... Transmit Data Buffer Empty ............................................................................................................... Transmit End Flag .............................................................................................................................. 133 133 133 134 134 135 12. Synchronous Serial Interface (SIO) 12.1 12.2 12.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Serial clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 12.3.1 Internal clock External clock 12.3.2.1 12.3.2.2 Leading edge Trailing edge 12.3.2 12.4 12.5 12.6 Clock source ....................................................................................................................................... 139 12.3.1.1 12.3.1.2 Shift edge............................................................................................................................................ 141 Number of bits to transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Number of words to transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Transfer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 12.6.1 12.6.2 12.6.3 4-bit and 8-bit transfer modes ............................................................................................................. 142 4-bit and 8-bit receive modes ............................................................................................................. 144 8-bit transfer / receive mode ............................................................................................................... 145 13. 10-bit AD Converter (ADC) 13.1 13.2 13.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Register configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 13.3.1 13.3.2 13.3.3 Software Start Mode ........................................................................................................................... 151 Repeat Mode ...................................................................................................................................... 151 Register Setting ................................................................................................................................ 152 13.6.1 13.6.2 13.6.3 13.6.4 Restrictions for AD Conversion interrupt (INTADC) usage ................................................................. Analog input pin voltage range ........................................................................................................... Analog input shared pins .................................................................................................................... Noise Countermeasure ....................................................................................................................... 13.4 13.5 13.6 STOP/SLOW Modes during AD Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Analog Input Voltage and AD Conversion Result . . . . . . . . . . . . . . . . . . . . . . . 154 Precautions about AD Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 155 155 155 155 14. Key-on Wakeup (KWU) 14.1 14.2 14.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 15. LCD Driver 15.1 15.2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 15.2.1 15.2.2 iv LCD driving methods .......................................................................................................................... 161 Frame frequency................................................................................................................................. 162 15.2.3 15.2.4 LCD drive voltage ............................................................................................................................... 163 Adjusting the LCD panel drive capability ............................................................................................ 163 15.3.1 15.3.2 Display data setting ............................................................................................................................ 164 Blanking .............................................................................................................................................. 164 15.4.1 15.4.2 15.4.3 Initial setting ........................................................................................................................................ 165 Store of display data ........................................................................................................................... 165 Example of LCD driver output............................................................................................................. 167 15.3 15.4 LCD Display Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 Control Method of LCD Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 16. Real-Time Clock 16.1 16.2 16.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Control of the RTC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 17. Multiply-Accumulate (MAC) Unit 17.1 17.2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 17.2.1 17.2.2 17.2.3 17.2.4 17.2.5 17.2.6 Command Register ............................................................................................................................. Status Register ................................................................................................................................... Multiplier data Register ....................................................................................................................... Multiplicand data Register .................................................................................................................. Result Register ................................................................................................................................... Addend Register ................................................................................................................................. 17.4.1 17.4.2 17.4.3 EMAC ................................................................................................................................................. 178 CMOD ................................................................................................................................................. 178 RCLR .................................................................................................................................................. 178 17.5.1 17.5.2 17.5.3 17.5.4 17.5.5 Unsigned Multiply Mode ..................................................................................................................... Signed Multiply Mode ......................................................................................................................... Unsigned Multiply-Accumulate Mode ................................................................................................. Signed Multiply-Accumulate Mode ..................................................................................................... Valid Numerical Ranges ..................................................................................................................... 179 179 179 180 180 17.6.1 17.6.2 17.6.3 17.6.4 17.6.5 Operation Status Flag (CALC) ............................................................................................................ Overflow Flag (OVRF) ........................................................................................................................ Carry Flag (CARF) .............................................................................................................................. Sign Flag (SIGN) ................................................................................................................................ Zero Flag (ZERF)................................................................................................................................ 181 181 181 181 181 17.3 17.4 17.5 17.6 17.7 175 176 176 176 176 176 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 Register Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 Arithmetic Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 Status Flags. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 Example of Software Processing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 18. Input/Output Circuitry 18.1 18.2 Control Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Input/Output Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 19. Electrical Characteristics 19.1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 v 19.2 19.3 19.4 19.5 19.6 19.7 19.8 Operating Condition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AD Conversion Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer Counter 1 input (ECIN) Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . Recommended Oscillating Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handling Precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186 187 188 189 190 190 190 20. Package Dimensions This is a technical document that describes the operating functions and electrical specifications of the 8-bit microcontroller series TLCS-870/C (LSI). vi TMP86CM23AUG CMOS 8-Bit Microcontroller TMP86CM23AUG Product No. ROM (MaskROM) RAM Package FLASH MCU Emulation Chip TMP86CM23AUG 32768 bytes 1536 bytes LQFP64-P-1010-0.50D TMP86FS23UG TMP86C923XB 1.1 Features 1. 8-bit single chip microcomputer TLCS-870/C series - Instruction execution time : 0.25 µs (at 16 MHz) 122 µs (at 32.768 kHz) - 132 types & 731 basic instructions 2. 20interrupt sources (External : 5 Internal : 15) 3. Input / Output ports (I/O : 48 pins Output : 3 pins) Large current output: 5pins (Typ. 20mA), LED direct drive 4. Prescaler - Time base timer - Divider output function 5. Watchdog Timer 6. 18-bit Timer/Counter : 1ch - Timer Mode - Event Counter Mode - Pulse Width Measurement Mode - Frequency Measurement Mode 7. 8-bit timer counter : 4 ch - Timer, Event counter, Programmable divider output (PDO), Pulse width modulation (PWM) output, • The information contained herein is subject to change without notice. 021023_D • TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc. 021023_A • The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer's own risk. 021023_B • The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. 060106_Q • The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patents or other rights of TOSHIBA or the third parties. 070122_C • The products described in this document are subject to foreign exchange and foreign trade control laws. 060925_E • For a discussion of how the reliability of microcontrollers can be predicted, please refer to Section 1.3 of the chapter entitled Quality and Reliability Assurance/Handling Precautions. 030619_S Page 1 1.1 Features TMP86CM23AUG Programmable pulse generation (PPG) modes 8. 8-bit UART : 1 ch 9. 8-bit SIO: 1 ch 10. 10-bit successive approximation type AD converter - Analog input: 8 ch 11. Key-on wakeup : 4 ch 12. LCD driver/controller - LCD direct drive capability (MAX 32 seg × 4 com) - 1/4,1/3,1/2duties or static drive are programmably selectable 13. Multiply accumulate unit (MAC) - Multiply or MAC mode are selectable - Signed or unsigned operation are selectable 14. Clock operation Single clock mode Dual clock mode 15. Low power consumption operation STOP mode: Oscillation stops. (Battery/Capacitor back-up.) SLOW1 mode: Low power consumption operation using low-frequency clock.(High-frequency clock stop.) SLOW2 mode: Low power consumption operation using low-frequency clock.(High-frequency clock oscillate.) IDLE0 mode: CPU stops, and only the Time-Based-Timer(TBT) on peripherals operate using high frequency clock. Release by falling edge of the source clock which is set by TBTCR<TBTCK>. IDLE1 mode: CPU stops and peripherals operate using high frequency clock. Release by interruputs(CPU restarts). IDLE2 mode: CPU stops and peripherals operate using high and low frequency clock. Release by interruputs. (CPU restarts). SLEEP0 mode: CPU stops, and only the Time-Based-Timer(TBT) on peripherals operate using low frequency clock.Release by falling edge of the source clock which is set by TBTCR<TBTCK>. SLEEP1 mode: CPU stops, and peripherals operate using low frequency clock. Release by interruput.(CPU restarts). SLEEP2 mode: CPU stops and peripherals operate using high and low frequency clock. interruput. 16. Wide operation voltage: 3.5 V to 5.5 V at 16MHz /32.768 kHz 2.7 V to 5.5 V at 8 MHz /32.768 kHz 1.8 V to 5.5 V at 4.2MHz /32.768 kHz Page 2 Release by TMP86CM23AUG 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 RESET (INT5/STOP) P20 AVDD VAREF (AIN0) P60 (ECIN/AIN1) P61 (ECNT/AIN2) P62 (INT0/AIN3) P63 (STOP2/AIN4) P64 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 VSS XIN XOUT TEST VDD (XTIN) P21 (XTOUT) P22 (SEG2) P85 (SEG1) P86 (SEG0) P87 COM3 COM2 COM1 COM0 VLC (TC4/SI) P30 (TC3/SO) P31 (SCK) P32 (TC6/PDO6/PWM6/PPG6) P33 (TC5/PDO5/PWM5) P34 (PDO4/PWM4/PPG4) P35 (PDO3/PWM3) P36 (DVO) P37 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 P84 (SEG3) P83 (SEG4) P82 (SEG5) P81 (SEG6) P80 (SEG7) P77 (SEG8) P76 (SEG9) P75 (SEG10) P74 (SEG11) P73 (SEG12) P72 (SEG13) P71 (SEG14) P70 (SEG15) P57 (SEG16) P56 (SEG17) P55 (SEG18) 1.2 Pin Assignment Figure 1-1 Pin Assignment Page 3 P54(SEG19) P53(SEG20) P52(SEG21) P51(SEG22) P50(SEG23) P17(SEG24) P16(SEG25) P15(SEG26) P14(SEG27/INT3) P13(SEG28/INT2) P12(SEG29/INT1) P11(SEG30/TXD) P10(SEG31/RXD/BOOT) P67(AIN7/STOP5) P66(AIN6/STOP4) P65(AIN5/STOP3) 1.3 Block Diagram TMP86CM23AUG 1.3 Block Diagram Figure 1-2 Block Diagram Page 4 TMP86CM23AUG 1.4 Pin Names and Functions Table 1-1 Pin Names and Functions(1/3) Pin Name Pin Number Input/Output Functions P17 SEG24 27 IO O PORT17 LCD segment output 24 P16 SEG25 26 IO O PORT16 LCD segment output 25 P15 SEG26 25 IO O PORT15 LCD segment output 26 P14 SEG27 INT3 24 IO O I PORT14 LCD segment output 27 External interrupt 3 input P13 SEG28 INT2 23 IO O I PORT13 LCD segment output 28 External interrupt 2 input P12 SEG29 INT1 22 IO O I PORT12 LCD segment output 29 External interrupt 1 input P11 SEG30 TXD 21 IO O O PORT11 LCD segment output 30 UART data output P10 SEG31 RXD 20 IO O I PORT10 LCD segment output 31 UART data input P22 XTOUT 7 IO O PORT22 Resonator connecting pins(32.768kHz) for inputting external clock P21 XTIN 6 IO I PORT21 Resonator connecting pins(32.768kHz) for inputting external clock 9 IO I I PORT20 STOP mode release signal input External interrupt 5 input 64 O O PORT37 Divider Output 63 O O PORT36 PDO3/PWM3 output 62 O O PORT35 PDO4/PWM4/PPG4 output 61 IO O I PORT34 PDO5/PWM5 output TC5 input 60 IO O I PORT33 PDO6/PWM6/PPG6 output TC6 input 59 IO IO PORT32 Serial Clock I/O 58 IO O I PORT31 Serial Data Output TC3 input P20 STOP INT5 P37 DVO P36 PDO3/PWM3 P35 PDO4/PWM4/PPG4 P34 PDO5/PWM5 TC5 P33 PDO6/PWM6/PPG6 TC6 P32 SCK P31 SO TC3 Page 5 1.4 Pin Names and Functions TMP86CM23AUG Table 1-1 Pin Names and Functions(2/3) Pin Name Pin Number Input/Output Functions P30 SI TC4 57 IO I I PORT30 Serial Data Input TC4 input P57 SEG16 35 IO O PORT57 LCD segment output 16 P56 SEG17 34 IO O PORT56 LCD segment output 17 P55 SEG18 33 IO O PORT55 LCD segment output 18 P54 SEG19 32 IO O PORT54 LCD segment output 19 P53 SEG20 31 IO O PORT53 LCD segment output 20 P52 SEG21 30 IO O PORT52 LCD segment output 21 P51 SEG22 29 IO O PORT51 LCD segment output 22 P50 SEG23 28 IO O PORT50 LCD segment output 23 P67 AIN7 STOP5 19 IO I I PORT67 Analog Input7 STOP5 input P66 AIN6 STOP4 18 IO I I PORT66 Analog Input6 STOP4 input P65 AIN5 STOP3 17 IO I I PORT65 Analog Input5 STOP3 input P64 AIN4 STOP2 16 IO I I PORT64 Analog Input4 STOP2 input 15 IO I I PORT63 Analog Input3 External interrupt 0 input P62 AIN2 ECNT 14 IO I I PORT62 Analog Input2 ECNT input P61 AIN1 ECIN 13 IO I I PORT61 Analog Input1 ECIN input P60 AIN0 12 IO I PORT60 Analog Input0 P77 SEG8 43 IO O PORT77 LCD segment output 8 P76 SEG9 42 IO O PORT76 LCD segment output 9 P75 SEG10 41 IO O PORT75 LCD segment output 10 P63 AIN3 INT0 Page 6 TMP86CM23AUG Table 1-1 Pin Names and Functions(3/3) Pin Name Pin Number Input/Output Functions P74 SEG11 40 IO O PORT74 LCD segment output 11 P73 SEG12 39 IO O PORT73 LCD segment output 12 P72 SEG13 38 IO O PORT72 LCD segment output 13 P71 SEG14 37 IO O PORT71 LCD segment output 14 P70 SEG15 36 IO O PORT70 LCD segment output 15 P87 SEG0 51 IO O PORT87 LCD segment output 0 P86 SEG1 50 IO O PORT86 LCD segment output 1 P85 SEG2 49 IO O PORT85 LCD segment output 2 P84 SEG3 48 IO O PORT84 LCD segment output 3 P83 SEG4 47 IO O PORT83 LCD segment output 4 P82 SEG5 46 IO O PORT82 LCD segment output 5 P81 SEG6 45 IO O PORT81 LCD segment output 6 P80 SEG7 44 IO O PORT80 LCD segment output 7 COM3 52 O LCD common output 3 COM2 53 O LCD common output 2 COM1 54 O LCD common output 1 COM0 55 O LCD common output 0 XIN 2 I Resonator connecting pins for high-frequency clock XOUT 3 O Resonator connecting pins for high-frequency clock RESET 8 I Reset signal TEST 4 I Test pin for out-going test. Normally, be fixed to low. VAREF 11 I Analog Base Voltage Input Pin for A/D Conversion AVDD 10 I Analog Power Supply VDD 5 I +5V VSS 1 I 0(GND) Page 7 1.4 Pin Names and Functions TMP86CM23AUG Page 8 TMP86CM23AUG 2. Operational Description 2.1 CPU Core Functions The CPU core consists of a CPU, a system clock controller, and an interrupt controller. This section provides a description of the CPU core, the program memory, the data memory, and the reset circuit. 2.1.1 Memory Address Map The TMP86CM23AUG memory is composed MaskROM, RAM, DBR(Data buffer register) and SFR(Special function register). They are all mapped in 64-Kbyte address space. Figure 2-1 shows the TMP86CM23AUG memory address map. 0000H SFR SFR: 64 bytes 003FH 0040H 1536 bytes RAM RAM: Stack 063FH 0F80H DBR: 128 bytes DBR Special function register includes: I/O ports Peripheral control registers Peripheral status registers System control registers Program status word Random access memory includes: Data memory 0FFFH 8000H MaskROM: Data buffer register includes: Peripheral control registers Peripheral status registers LCD display memory Program memory 32768 bytes MaskROM FFB0H Vector table for interrupts (16 bytes) FFBFH FFC0H Vector table for vector call instructions (32 bytes) FFDFH FFE0H Vector table for interrupts FFFFH (32 bytes) Figure 2-1 Memory Address Map 2.1.2 Program Memory (MaskROM) The TMP86CM23AUG has a 32768 bytes (Address 8000H to FFFFH) of program memory (MaskROM ). Page 9 2. Operational Description 2.2 System Clock Controller 2.1.3 TMP86CM23AUG Data Memory (RAM) The TMP86CM23AUG has 1536bytes (Address 0040H to 063FH) of internal RAM. The first 192 bytes (0040H to 00FFH) of the internal RAM are located in the direct area; instructions with shorten operations are available against such an area. The data memory contents become unstable when the power supply is turned on; therefore, the data memory should be initialized by an initialization routine. Example :Clears RAM to “00H”. (TMP86CM23AUG) SRAMCLR: LD HL, 0040H ; Start address setup LD A, H ; Initial value (00H) setup LD BC, 05FFH LD (HL), A INC HL DEC BC JRS F, SRAMCLR 2.2 System Clock Controller The system clock controller consists of a clock generator, a timing generator, and a standby controller. Timing generator control register TBTCR 0036H Clock generator XIN fc High-frequency clock oscillator Timing generator XOUT Standby controller 0038H XTIN Low-frequency clock oscillator SYSCR1 fs System clocks 0039H SYSCR2 System control registers XTOUT Clock generator control Figure 2-2 System Colck Control 2.2.1 Clock Generator The clock generator generates the basic clock which provides the system clocks supplied to the CPU core and peripheral hardware. It contains two oscillation circuits: One for the high-frequency clock and one for the low-frequency clock. Power consumption can be reduced by switching of the standby controller to low-power operation based on the low-frequency clock. The high-frequency (fc) clock and low-frequency (fs) clock can easily be obtained by connecting a resonator between the XIN/XOUT and XTIN/XTOUT pins respectively. Clock input from an external oscillator is also possible. In this case, external clock is applied to XIN/XTIN pin with XOUT/XTOUT pin not connected. Page 10 TMP86CM23AUG Low-frequency clock High-frequency clock XIN XOUT XIN XOUT XTIN XTOUT (Open) (a) Crystal/Ceramic resonator XTIN XTOUT (Open) (c) Crystal (b) External oscillator (d) External oscillator Figure 2-3 Examples of Resonator Connection Note:The function to monitor the basic clock directly at external is not provided for hardware, however, with disabling all interrupts and watchdog timers, the oscillation frequency can be adjusted by monitoring the pulse which the fixed frequency is outputted to the port by the program. The system to require the adjustment of the oscillation frequency should create the program for the adjustment in advance. Page 11 2. Operational Description 2.2 System Clock Controller 2.2.2 TMP86CM23AUG Timing Generator The timing generator generates the various system clocks supplied to the CPU core and peripheral hardware from the basic clock (fc or fs). The timing generator provides the following functions. 1. Generation of main system clock 2. Generation of divider output (DVO) pulses 3. Generation of source clocks for time base timer 4. Generation of source clocks for watchdog timer 5. Generation of internal source clocks for timer/counters 6. Generation of warm-up clocks for releasing STOP mode 7. LCD 2.2.2.1 Configuration of timing generator The timing generator consists of a 2-stage prescaler, a 21-stage divider, a main system clock generator, and machine cycle counters. An input clock to the 7th stage of the divider depends on the operating mode, SYSCR2<SYSCK> and TBTCR<DV7CK>, that is shown in Figure 2-4. As reset and STOP mode started/canceled, the prescaler and the divider are cleared to “0”. fc or fs Main system clock generator Machine cycle counters SYSCK DV7CK High-frequency clock fc Low-frequency clock fs 1 2 fc/4 S A Divider Y 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 B Multiplexer S B0 B1 A0 Y0 A1 Y1 Multiplexer Warm-up controller Watchdog timer Timer counter, Serial interface, Time-base-timer, divider output, etc. (Peripheral functions) Figure 2-4 Configuration of Timing Generator Page 12 TMP86CM23AUG Timing Generator Control Register TBTCR (0036H) 7 6 (DVOEN) 5 (DVOCK) DV7CK 4 3 DV7CK (TBTEN) Selection of input to the 7th stage of the divider 2 1 0 (TBTCK) (Initial value: 0000 0000) 0: fc/28 [Hz] 1: fs R/W Note 1: In single clock mode, do not set DV7CK to “1”. Note 2: Do not set “1” on DV7CK while the low-frequency clock is not operated stably. Note 3: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *: Don’t care Note 4: In SLOW1/2 and SLEEP1/2 modes, the DV7CK setting is ineffective, and fs is input to the 7th stage of the divider. Note 5: When STOP mode is entered from NORMAL1/2 mode, the DV7CK setting is ineffective during the warm-up period after release of STOP mode, and the 6th stage of the divider is input to the 7th stage during this period. 2.2.2.2 Machine cycle Instruction execution and peripheral hardware operation are synchronized with the main system clock. The minimum instruction execution unit is called an “machine cycle”. There are a total of 10 different types of instructions for the TLCS-870/C Series: Ranging from 1-cycle instructions which require one machine cycle for execution to 10-cycle instructions which require 10 machine cycles for execution. A machine cycle consists of 4 states (S0 to S3), and each state consists of one main system clock. 1/fc or 1/fs [s] Main system clock State S0 S1 S2 S3 S0 S1 S2 S3 Machine cycle Figure 2-5 Machine Cycle 2.2.3 Operation Mode Control Circuit The operation mode control circuit starts and stops the oscillation circuits for the high-frequency and lowfrequency clocks, and switches the main system clock. There are three operating modes: Single clock mode, dual clock mode and STOP mode. These modes are controlled by the system control registers (SYSCR1 and SYSCR2). Figure 2-6 shows the operating mode transition diagram. 2.2.3.1 Single-clock mode Only the oscillation circuit for the high-frequency clock is used, and P21 (XTIN) and P22 (XTOUT) pins are used as input/output ports. The main-system clock is obtained from the high-frequency clock. In the single-clock mode, the machine cycle time is 4/fc [s]. (1) NORMAL1 mode In this mode, both the CPU core and on-chip peripherals operate using the high-frequency clock. The TMP86CM23AUG is placed in this mode after reset. Page 13 2. Operational Description 2.2 System Clock Controller TMP86CM23AUG (2) IDLE1 mode In this mode, the internal oscillation circuit remains active. The CPU and the watchdog timer are halted; however on-chip peripherals remain active (Operate using the high-frequency clock). IDLE1 mode is started by SYSCR2<IDLE> = "1", and IDLE1 mode is released to NORMAL1 mode by an interrupt request from the on-chip peripherals or external interrupt inputs. When the IMF (Interrupt master enable flag) is “1” (Interrupt enable), the execution will resume with the acceptance of the interrupt, and the operation will return to normal after the interrupt service is completed. When the IMF is “0” (Interrupt disable), the execution will resume with the instruction which follows the IDLE1 mode start instruction. (3) IDLE0 mode In this mode, all the circuit, except oscillator and the timer-base-timer, stops operation. This mode is enabled by SYSCR2<TGHALT> = "1". When IDLE0 mode starts, the CPU stops and the timing generator stops feeding the clock to the peripheral circuits other than TBT. Then, upon detecting the falling edge of the source clock selected with TBTCR<TBTCK>, the timing generator starts feeding the clock to all peripheral circuits. When returned from IDLE0 mode, the CPU restarts operating, entering NORMAL1 mode back again. IDLE0 mode is entered and returned regardless of how TBTCR<TBTEN> is set. When IMF = “1”, EF6 (TBT interrupt individual enable flag) = “1”, and TBTCR<TBTEN> = “1”, interrupt processing is performed. When IDLE0 mode is entered while TBTCR<TBTEN> = “1”, the INTTBT interrupt latch is set after returning to NORMAL1 mode. 2.2.3.2 Dual-clock mode Both the high-frequency and low-frequency oscillation circuits are used in this mode. P21 (XTIN) and P22 (XTOUT) pins cannot be used as input/output ports. The main system clock is obtained from the high-frequency clock in NORMAL2 and IDLE2 modes, and is obtained from the low-frequency clock in SLOW and SLEEP modes. The machine cycle time is 4/fc [s] in the NORMAL2 and IDLE2 modes, and 4/fs [s] (122 µs at fs = 32.768 kHz) in the SLOW and SLEEP modes. The TLCS-870/C is placed in the signal-clock mode during reset. To use the dual-clock mode, the lowfrequency oscillator should be turned on at the start of a program. (1) NORMAL2 mode In this mode, the CPU core operates with the high-frequency clock. On-chip peripherals operate using the high-frequency clock and/or low-frequency clock. (2) SLOW2 mode In this mode, the CPU core operates with the low-frequency clock, while both the high-frequency clock and the low-frequency clock are operated. As the SYSCR2<SYSCK> becomes "1", the hardware changes into SLOW2 mode. As the SYSCR2<SYSCK> becomes “0”, the hardware changes into NORMAL2 mode. As the SYSCR2<XEN> becomes “0”, the hardware changes into SLOW1 mode. Do not clear SYSCR2<XTEN> to “0” during SLOW2 mode. (3) SLOW1 mode This mode can be used to reduce power-consumption by turning off oscillation of the high-frequency clock. The CPU core and on-chip peripherals operate using the low-frequency clock. Page 14 TMP86CM23AUG Switching back and forth between SLOW1 and SLOW2 modes are performed by SYSCR2<XEN>. In SLOW1 and SLEEP modes, the input clock to the 1st stage of the divider is stopped; output from the 1st to 6th stages is also stopped. (4) IDLE2 mode In this mode, the internal oscillation circuit remain active. The CPU and the watchdog timer are halted; however, on-chip peripherals remain active (Operate using the high-frequency clock and/or the low-frequency clock). Starting and releasing of IDLE2 mode are the same as for IDLE1 mode, except that operation returns to NORMAL2 mode. (5) SLEEP1 mode In this mode, the internal oscillation circuit of the low-frequency clock remains active. The CPU, the watchdog timer, and the internal oscillation circuit of the high-frequency clock are halted; however, on-chip peripherals remain active (Operate using the low-frequency clock). Starting and releasing of SLEEP mode are the same as for IDLE1 mode, except that operation returns to SLOW1 mode. In SLOW1 and SLEEP1 modes, the input clock to the 1st stage of the divider is stopped; output from the 1st to 6th stages is also stopped. (6) SLEEP2 mode The SLEEP2 mode is the idle mode corresponding to the SLOW2 mode. The status under the SLEEP2 mode is same as that under the SLEEP1 mode, except for the oscillation circuit of the highfrequency clock. (7) SLEEP0 mode In this mode, all the circuit, except oscillator and the timer-base-timer, stops operation. This mode is enabled by setting “1” on bit SYSCR2<TGHALT>. When SLEEP0 mode starts, the CPU stops and the timing generator stops feeding the clock to the peripheral circuits other than TBT. Then, upon detecting the falling edge of the source clock selected with TBTCR<TBTCK>, the timing generator starts feeding the clock to all peripheral circuits. When returned from SLEEP0 mode, the CPU restarts operating, entering SLOW1 mode back again. SLEEP0 mode is entered and returned regardless of how TBTCR<TBTEN> is set. When IMF = “1”, EF6 (TBT interrupt individual enable flag) = “1”, and TBTCR<TBTEN> = “1”, interrupt processing is performed. When SLEEP0 mode is entered while TBTCR<TBTEN> = “1”, the INTTBT interrupt latch is set after returning to SLOW1 mode. 2.2.3.3 STOP mode In this mode, the internal oscillation circuit is turned off, causing all system operations to be halted. The internal status immediately prior to the halt is held with a lowest power consumption during STOP mode. STOP mode is started by the system control register 1 (SYSCR1), and STOP mode is released by a inputting (Either level-sensitive or edge-sensitive can be programmably selected) to the STOP pin. After the warm-up period is completed, the execution resumes with the instruction which follows the STOP mode start instruction. Page 15 2. Operational Description 2.2 System Clock Controller TMP86CM23AUG IDLE0 mode RESET Reset release Note 2 SYSCR2<TGHALT> = "1" SYSCR1<STOP> = "1" SYSCR2<IDLE> = "1" NORMAL1 mode Interrupt STOP pin input IDLE1 mode (a) Single-clock mode SYSCR2<XTEN> = "0" SYSCR2<XTEN> = "1" SYSCR2<IDLE> = "1" IDLE2 mode NORMAL2 mode Interrupt SYSCR1<STOP> = "1" STOP pin input SYSCR2<SYSCK> = "0" SYSCR2<SYSCK> = "1" STOP SYSCR2<IDLE> = "1" SLEEP2 mode SLOW2 mode Interrupt SYSCR2<XEN> = "0" SYSCR2<XEN> = "1" SYSCR2<IDLE> = "1" SLEEP1 mode Interrupt (b) Dual-clock mode SYSCR1<STOP> = "1" SLOW1 mode STOP pin input SYSCR2<TGHALT> = "1" Note 2 SLEEP0 mode Note 1: NORMAL1 and NORMAL2 modes are generically called NORMAL; SLOW1 and SLOW2 are called SLOW; IDLE0, IDLE1 and IDLE2 are called IDLE; SLEEP0, SLEEP1 and SLEEP2 are called SLEEP. Note 2: The mode is released by falling edge of TBTCR<TBTCK> setting. Figure 2-6 Operating Mode Transition Diagram Table 2-1 Operating Mode and Conditions Oscillator Operating Mode High Frequency Low Frequency RESET NORMAL1 CPU Core TBT Other Peripherals Reset Reset Reset Operate Oscillation Single clock Machine Cycle Time IDLE1 Operate Stop IDLE0 4/fc [s] Operate Halt Halt STOP Stop Halt – Operate with high frequency NORMAL2 IDLE2 4/fc [s] Halt Oscillation Operate with low frequency SLOW2 Dual clock Oscillation SLEEP2 Operate Operate Operate with low frequency SLOW1 SLEEP1 Halt 4/fs [s] Stop SLEEP0 Halt Halt STOP Stop Halt Page 16 – TMP86CM23AUG System Control Register 1 SYSCR1 7 6 5 4 (0038H) STOP RELM RETM OUTEN 3 2 1 0 WUT (Initial value: 0000 00**) STOP STOP mode start 0: CPU core and peripherals remain active 1: CPU core and peripherals are halted (Start STOP mode) R/W RELM Release method for STOP mode 0: Edge-sensitive release 1: Level-sensitive release R/W RETM Operating mode after STOP mode 0: Return to NORMAL1/2 mode 1: Return to SLOW1 mode R/W Port output during STOP mode 0: High impedance 1: Output kept R/W OUTEN WUT Warm-up time at releasing STOP mode Return to NORMAL mode Return to SLOW mode 00 3 x 216/fc 3 x 213/fs 01 216/fc 213/fs 10 3 x 214/fc 3 x 26/fs 11 214/fc 26/fs R/W Note 1: Always set RETM to “0” when transiting from NORMAL mode to STOP mode. Always set RETM to “1” when transiting from SLOW mode to STOP mode. Note 2: When STOP mode is released with RESET pin input, a return is made to NORMAL1 regardless of the RETM contents. Note 3: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *; Don’t care Note 4: Bits 1 and 0 in SYSCR1 are read as undefined data when a read instruction is executed. Note 5: As the hardware becomes STOP mode under OUTEN = “0”, input value is fixed to “0”; therefore it may cause external interrupt request on account of falling edge. Note 6: When the key-on wakeup is used, RELM should be set to "1". Note 7: Port P20 is used as STOP pin. Therefore, when stop mode is started, OUTEN does not affect to P20, and P20 becomes High-Z mode. Note 8: The warmig-up time should be set correctly for using oscillator. System Control Register 2 SYSCR2 (0039H) 7 6 5 4 XEN XTEN SYSCK IDLE 3 2 1 TGHALT 0 (Initial value: 1000 *0**) XEN High-frequency oscillator control 0: Turn off oscillation 1: Turn on oscillation XTEN Low-frequency oscillator control 0: Turn off oscillation 1: Turn on oscillation SYSCK Main system clock select (Write)/main system clock monitor (Read) 0: High-frequency clock (NORMAL1/NORMAL2/IDLE1/IDLE2) 1: Low-frequency clock (SLOW1/SLOW2/SLEEP1/SLEEP2) IDLE CPU and watchdog timer control (IDLE1/2 and SLEEP1/2 modes) 0: CPU and watchdog timer remain active 1: CPU and watchdog timer are stopped (Start IDLE1/2 and SLEEP1/2 modes) TGHALT TG control (IDLE0 and SLEEP0 modes) 0: Feeding clock to all peripherals from TG 1: Stop feeding clock to peripherals except TBT from TG. (Start IDLE0 and SLEEP0 modes) R/W R/W Note 1: A reset is applied if both XEN and XTEN are cleared to “0”, XEN is cleared to “0” when SYSCK = “0”, or XTEN is cleared to “0” when SYSCK = “1”. Note 2: *: Don’t care, TG: Timing generator, *; Don’t care Note 3: Bits 3, 1 and 0 in SYSCR2 are always read as undefined value. Note 4: Do not set IDLE and TGHALT to “1” simultaneously. Note 5: Because returning from IDLE0/SLEEP0 to NORMAL1/SLOW1 is executed by the asynchronous internal clock, the period of IDLE0/SLEEP0 mode might be shorter than the period setting by TBTCR<TBTCK>. Note 6: When IDLE1/2 or SLEEP1/2 mode is released, IDLE is automatically cleared to “0”. Note 7: When IDLE0 or SLEEP0 mode is released, TGHALT is automatically cleared to “0”. Note 8: Before setting TGHALT to “1”, be sure to stop peripherals. If peripherals are not stopped, the interrupt latch of peripherals may be set after IDLE0 or SLEEP0 mode is released. Page 17 2. Operational Description 2.2 System Clock Controller 2.2.4 TMP86CM23AUG Operating Mode Control 2.2.4.1 STOP mode STOP mode is controlled by the system control register 1, the STOP pin input and key-on wakeup input (STOP5 to STOP2) which is controlled by the STOP mode release control register (STOPCR). The STOP pin is also used both as a port P20 and an INT5 (external interrupt input 5) pin. STOP mode is started by setting SYSCR1<STOP> to “1”. During STOP mode, the following status is maintained. 1. Oscillations are turned off, and all internal operations are halted. 2. The data memory, registers, the program status word and port output latches are all held in the status in effect before STOP mode was entered. 3. The prescaler and the divider of the timing generator are cleared to “0”. 4. The program counter holds the address 2 ahead of the instruction (e.g., [SET (SYSCR1).7]) which started STOP mode. STOP mode includes a level-sensitive mode and an edge-sensitive mode, either of which can be selected with the SYSCR1<RELM>. Do not use any key-on wakeup input (STOP5 to STOP2) for releasing STOP mode in edge-sensitive mode. Note 1: The STOP mode can be released by either the STOP or key-on wakeup pin (STOP5 to STOP2). However, because the STOP pin is different from the key-on wakeup and can not inhibit the release input, the STOP pin must be used for releasing STOP mode. Note 2: During STOP period (from start of STOP mode to end of warm up), due to changes in the external interrupt pin signal, interrupt latches may be set to “1” and interrupts may be accepted immediately after STOP mode is released. Before starting STOP mode, therefore, disable interrupts. Also, before enabling interrupts after STOP mode is released, clear unnecessary interrupt latches. (1) Level-sensitive release mode (RELM = “1”) In this mode, STOP mode is released by setting the STOP pin high or setting the STOP5 to STOP2 pin input which is enabled by STOPCR. This mode is used for capacitor backup when the main power supply is cut off and long term battery backup. Even if an instruction for starting STOP mode is executed while STOP pin input is high or STOP5 to STOP2 input is low, STOP mode does not start but instead the warm-up sequence starts immediately. Thus, to start STOP mode in the level-sensitive release mode, it is necessary for the program to first confirm that the STOP pin input is low or STOP5 to STOP2 input is high. The following two methods can be used for confirmation. 1. Testing a port. 2. Using an external interrupt input INT5 (INT5 is a falling edge-sensitive input). Example 1 :Starting STOP mode from NORMAL mode by testing a port P20. SSTOPH: LD (SYSCR1), 01010000B ; Sets up the level-sensitive release mode TEST (P2PRD). 0 ; Wait until the STOP pin input goes low level JRS F, SSTOPH ; IMF ← 0 DI SET (SYSCR1). 7 ; Starts STOP mode Page 18 TMP86CM23AUG Example 2 :Starting STOP mode from NORMAL mode with an INT5 interrupt. PINT5: TEST (P2PRD). 0 ; To reject noise, STOP mode does not start if JRS F, SINT5 LD (SYSCR1), 01010000B port P20 is at high ; Sets up the level-sensitive release mode. ; IMF ← 0 DI SET SINT5: (SYSCR1). 7 ; Starts STOP mode RETI VIH STOP pin XOUT pin NORMAL operation STOP operation Warm up Confirm by program that the STOP pin input is low and start STOP mode. NORMAL operation STOP mode is released by the hardware. Always released if the STOP pin input is high. Figure 2-7 Level-sensitive Release Mode Note 1: Even if the STOP pin input is low after warm-up start, the STOP mode is not restarted. Note 2: In this case of changing to the level-sensitive mode from the edge-sensitive mode, the release mode is not switched until a rising edge of the STOP pin input is detected. (2) Edge-sensitive release mode (RELM = “0”) In this mode, STOP mode is released by a rising edge of the STOP pin input. This is used in applications where a relatively short program is executed repeatedly at periodic intervals. This periodic signal (for example, a clock from a low-power consumption oscillator) is input to the STOP pin. In the edge-sensitive release mode, STOP mode is started even when the STOP pin input is high level. Do not use any STOP5 to STOP2 pin input for releasing STOP mode in edge-sensitive release mode. Example :Starting STOP mode from NORMAL mode ; IMF ← 0 DI LD (SYSCR1), 10010000B ; Starts after specified to the edge-sensitive release mode VIH STOP pin XOUT pin NORMAL operation STOP operation Warm up NORMAL operation STOP mode started by the program. STOP operation STOP mode is released by the hardware at the rising edge of STOP pin input. Figure 2-8 Edge-sensitive Release Mode Page 19 2. Operational Description 2.2 System Clock Controller TMP86CM23AUG STOP mode is released by the following sequence. 1. In the dual-clock mode, when returning to NORMAL2, both the high-frequency and lowfrequency clock oscillators are turned on; when returning to SLOW1 mode, only the lowfrequency clock oscillator is turned on. In the single-clock mode, only the high-frequency clock oscillator is turned on. 2. A warm-up period is inserted to allow oscillation time to stabilize. During warm up, all internal operations remain halted. Four different warm-up times can be selected with the SYSCR1<WUT> in accordance with the resonator characteristics. 3. When the warm-up time has elapsed, normal operation resumes with the instruction following the STOP mode start instruction. Note 1: When the STOP mode is released, the start is made after the prescaler and the divider of the timing generator are cleared to "0". Note 2: STOP mode can also be released by inputting low level on the RESET pin, which immediately performs the normal reset operation. Note 3: When STOP mode is released with a low hold voltage, the following cautions must be observed. The power supply voltage must be at the operating voltage level before releasing STOP mode. The RESET pin input must also be “H” level, rising together with the power supply voltage. In this case, if an external time constant circuit has been connected, the RESET pin input voltage will increase at a slower pace than the power supply voltage. At this time, there is a danger that a reset may occur if input voltage level of the RESET pin drops below the non-inverting high-level input voltage (Hysteresis input). Table 2-2 Warm-up Time Example (at fc = 16.0 MHz, fs = 32.768 kHz) Warm-up Time [ms] WUT 00 01 10 11 Return to NORMAL Mode Return to SLOW Mode 12.288 4.096 3.072 1.024 750 250 5.85 1.95 Note 1: The warm-up time is obtained by dividing the basic clock by the divider. Therefore, the warm-up time may include a certain amount of error if there is any fluctuation of the oscillation frequency when STOP mode is released. Thus, the warm-up time must be considered as an approximate value. Page 20 Page 21 Figure 2-9 STOP Mode Start/Release Divider Instruction execution Program counter Main system clock Oscillator circuit STOP pin input Divider Instruction execution Program counter Main system clock Oscillator circuit 0 Halt Turn off Turn on Turn on n Count up a+3 Warm up a+2 n+2 n+3 n+4 0 (b) STOP mode release 1 Instruction address a + 2 a+4 2 Instruction address a + 3 a+5 (a) STOP mode start (Example: Start with SET (SYSCR1). 7 instruction located at address a) n+1 SET (SYSCR1). 7 a+3 3 Instruction address a + 4 a+6 0 Halt Turn off TMP86CM23AUG 2. Operational Description 2.2 System Clock Controller 2.2.4.2 TMP86CM23AUG IDLE1/2 mode and SLEEP1/2 mode IDLE1/2 and SLEEP1/2 modes are controlled by the system control register 2 (SYSCR2) and maskable interrupts. The following status is maintained during these modes. 1. Operation of the CPU and watchdog timer (WDT) is halted. On-chip peripherals continue to operate. 2. The data memory, CPU registers, program status word and port output latches are all held in the status in effect before these modes were entered. 3. The program counter holds the address 2 ahead of the instruction which starts these modes. Starting IDLE1/2 and SLEEP1/2 modes by instruction CPU and WDT are halted Yes Reset input Reset No No Interrupt request Yes “0” IMF “1” (Interrupt release mode) Normal release mode Interrupt processing Execution of the instruction which follows the IDLE1/2 and SLEEP1/2 modes start instruction Figure 2-10 IDLE1/2 and SLEEP1/2 Modes Page 22 TMP86CM23AUG • Start the IDLE1/2 and SLEEP1/2 modes After IMF is set to "0", set the individual interrupt enable flag (EF) which releases IDLE1/2 and SLEEP1/2 modes. To start IDLE1/2 and SLEEP1/2 modes, set SYSCR2<IDLE> to “1”. • Release the IDLE1/2 and SLEEP1/2 modes IDLE1/2 and SLEEP1/2 modes include a normal release mode and an interrupt release mode. These modes are selected by interrupt master enable flag (IMF). After releasing IDLE1/2 and SLEEP1/2 modes, the SYSCR2<IDLE> is automatically cleared to “0” and the operation mode is returned to the mode preceding IDLE1/2 and SLEEP1/2 modes. IDLE1/2 and SLEEP1/2 modes can also be released by inputting low level on the RESET pin. After releasing reset, the operation mode is started from NORMAL1 mode. (1) Normal release mode (IMF = “0”) IDLE1/2 and SLEEP1/2 modes are released by any interrupt source enabled by the individual interrupt enable flag (EF). After the interrupt is generated, the program operation is resumed from the instruction following the IDLE1/2 and SLEEP1/2 modes start instruction. Normally, the interrupt latches (IL) of the interrupt source used for releasing must be cleared to “0” by load instructions. (2) Interrupt release mode (IMF = “1”) IDLE1/2 and SLEEP1/2 modes are released by any interrupt source enabled with the individual interrupt enable flag (EF) and the interrupt processing is started. After the interrupt is processed, the program operation is resumed from the instruction following the instruction, which starts IDLE1/2 and SLEEP1/2 modes. Note: When a watchdog timer interrupts is generated immediately before IDLE1/2 and SLEEP1/2 modes are started, the watchdog timer interrupt will be processed but IDLE1/2 and SLEEP1/2 modes will not be started. Page 23 Page 24 Figure 2-11 IDLE1/2 and SLEEP1/2 Modes Start/Release Watchdog timer Instruction execution Program counter Interrupt request Main system clock Watchdog timer Instruction execution Program counter Interrupt request Main system clock Watchdog timer Instruction execution Program counter Interrupt request Main system clock Halt Halt Halt Halt Operate Operate Operate Acceptance of interrupt Instruction address a + 2 a+4 (b) IDLE1/2 and SLEEP1/2 modes release 㽳㩷Interrupt release mode a+3 㽲㩷Normal release mode a+3 (a) IDLE1/2 and SLEEP1/2 modes start (Example: Starting with the SET instruction located at address a) Operate SET (SYSCR2). 4 a+2 Halt a+3 2.2 System Clock Controller 2. Operational Description TMP86CM23AUG TMP86CM23AUG 2.2.4.3 IDLE0 and SLEEP0 modes (IDLE0, SLEEP0) IDLE0 and SLEEP0 modes are controlled by the system control register 2 (SYSCR2) and the time base timer control register (TBTCR). The following status is maintained during IDLE0 and SLEEP0 modes. 1. Timing generator stops feeding clock to peripherals except TBT. 2. The data memory, CPU registers, program status word and port output latches are all held in the status in effect before IDLE0 and SLEEP0 modes were entered. 3. The program counter holds the address 2 ahead of the instruction which starts IDLE0 and SLEEP0 modes. Note: Before starting IDLE0 or SLEEP0 mode, be sure to stop (Disable) peripherals. Stopping peripherals by instruction Starting IDLE0, SLEEP0 modes by instruction CPU and WDT are halted Reset input Yes Reset No No TBT source clock falling edge Yes No TBTCR<TBTEN> = "1" Yes No TBT interrupt enable Yes (Normal release mode) No IMF = "1" Yes (Interrupt release mode) Interrupt processing Execution of the instruction which follows the IDLE0, SLEEP0 modes start instruction Figure 2-12 IDLE0 and SLEEP0 Modes Page 25 2. Operational Description 2.2 System Clock Controller TMP86CM23AUG • Start the IDLE0 and SLEEP0 modes Stop (Disable) peripherals such as a timer counter. To start IDLE0 and SLEEP0 modes, set SYSCR2<TGHALT> to “1”. • Release the IDLE0 and SLEEP0 modes IDLE0 and SLEEP0 modes include a normal release mode and an interrupt release mode. These modes are selected by interrupt master flag (IMF), the individual interrupt enable flag of TBT and TBTCR<TBTEN>. After releasing IDLE0 and SLEEP0 modes, the SYSCR2<TGHALT> is automatically cleared to “0” and the operation mode is returned to the mode preceding IDLE0 and SLEEP0 modes. Before starting the IDLE0 or SLEEP0 mode, when the TBTCR<TBTEN> is set to “1”, INTTBT interrupt latch is set to “1”. IDLE0 and SLEEP0 modes can also be released by inputting low level on the RESET pin. After releasing reset, the operation mode is started from NORMAL1 mode. Note: IDLE0 and SLEEP0 modes start/release without reference to TBTCR<TBTEN> setting. (1) Normal release mode (IMF•EF6•TBTCR<TBTEN> = “0”) IDLE0 and SLEEP0 modes are released by the source clock falling edge, which is setting by the TBTCR<TBTCK>. After the falling edge is detected, the program operation is resumed from the instruction following the IDLE0 and SLEEP0 modes start instruction. Before starting the IDLE0 or SLEEP0 mode, when the TBTCR<TBTEN> is set to “1”, INTTBT interrupt latch is set to “1”. (2) Interrupt release mode (IMF•EF6•TBTCR<TBTEN> = “1”) IDLE0 and SLEEP0 modes are released by the source clock falling edge, which is setting by the TBTCR<TBTCK> and INTTBT interrupt processing is started. Note 1: Because returning from IDLE0, SLEEP0 to NORMAL1, SLOW1 is executed by the asynchronous internal clock, the period of IDLE0, SLEEP0 mode might be the shorter than the period setting by TBTCR<TBTCK>. Note 2: When a watchdog timer interrupt is generated immediately before IDLE0/SLEEP0 mode is started, the watchdog timer interrupt will be processed but IDLE0/SLEEP0 mode will not be started. Page 26 Page 27 Figure 2-13 IDLE0 and SLEEP0 Modes Start/Release Watchdog timer Instruction execution Program counter TBT clock Halt Halt Halt Watchdog timer Main system clock Halt Instruction execution Program counter TBT clock Main system clock Watchdog timer Instruction execution Program counter Interrupt request Main system clock a+3 Halt Operate Operate (b) IDLE and SLEEP0 modes release 㽳㩷Interrupt release mode a+3 㽲㩷Normal release mode a+3 Acceptance of interrupt Instruction address a + 2 a+4 (a) IDLE0 and SLEEP0 modes start (Example: Starting with the SET instruction located at address a Operate SET (SYSCR2). 2 a+2 TMP86CM23AUG 2. Operational Description 2.2 System Clock Controller 2.2.4.4 TMP86CM23AUG SLOW mode SLOW mode is controlled by the system control register 2 (SYSCR2). The following is the methods to switch the mode with the warm-up counter. (1) Switching from NORMAL2 mode to SLOW1 mode First, set SYSCR2<SYSCK> to switch the main system clock to the low-frequency clock for SLOW2 mode. Next, clear SYSCR2<XEN> to turn off high-frequency oscillation. Note: The high-frequency clock can be continued oscillation in order to return to NORMAL2 mode from SLOW mode quickly. Always turn off oscillation of high-frequency clock when switching from SLOW mode to stop mode. Example 1 :Switching from NORMAL2 mode to SLOW1 mode. SET (SYSCR2). 5 ; SYSCR2<SYSCK> ← 1 (Switches the main system clock to the low-frequency clock for SLOW2) CLR (SYSCR2). 7 ; SYSCR2<XEN> ← 0 (Turns off high-frequency oscillation) Example 2 :Switching to the SLOW1 mode after low-frequency clock has stabilized. SET (SYSCR2). 6 ; SYSCR2<XTEN> ← 1 LD (TC3CR), 43H ; Sets mode for TC4, 3 (16-bit mode, fs for source) LD (TC4CR), 05H ; Sets warming-up counter mode LDW (TTREG3), 8000H ; Sets warm-up time (Depend on oscillator accompanied) ; IMF ← 0 DI SET (EIRH). 4 ; IMF ← 1 EI SET ; Enables INTTC4 (TC4CR). 3 ; Starts TC4, 3 CLR (TC4CR). 3 ; Stops TC4, 3 SET (SYSCR2). 5 ; SYSCR2<SYSCK> ← 1 : PINTTC4: (Switches the main system clock to the low-frequency clock) CLR (SYSCR2). 7 ; SYSCR2<XEN> ← 0 (Turns off high-frequency oscillation) RETI : VINTTC4: DW PINTTC4 ; INTTC4 vector table Page 28 TMP86CM23AUG (2) Switching from SLOW1 mode to NORMAL2 mode First, set SYSCR2<XEN> to turn on the high-frequency oscillation. When time for stabilization (Warm up) has been taken by the timer/counter (TC4,TC3), clear SYSCR2<SYSCK> to switch the main system clock to the high-frequency clock. SLOW mode can also be released by inputting low level on the RESET pin. After releasing reset, the operation mode is started from NORMAL1 mode. Note: After SYSCK is cleared to “0”, executing the instructions is continiued by the low-frequency clock for the period synchronized with low-frequency and high-frequency clocks. High-frequency clock Low-frequency clock Main system clock SYSCK Example :Switching from the SLOW1 mode to the NORMAL2 mode (fc = 16 MHz, warm-up time is 4.0 ms). SET (SYSCR2). 7 ; SYSCR2<XEN> ← 1 (Starts high-frequency oscillation) LD (TC3CR), 63H ; Sets mode for TC4, 3 (16-bit mode, fc for source) LD (TC4CR), 05H ; Sets warming-up counter mode LD (TTREG4), 0F8H ; Sets warm-up time ; IMF ← 0 DI SET (EIRH). 4 ; IMF ← 1 EI SET ; Enables INTTC4 (TC4CR). 3 ; Starts TC4, 3 CLR (TC4CR). 3 ; Stops TC4, 3 CLR (SYSCR2). 5 ; SYSCR2<SYSCK> ← 0 : PINTTC4: (Switches the main system clock to the high-frequency clock) RETI : VINTTC4: DW PINTTC4 ; INTTC4 vector table Page 29 Page 30 Figure 2-14 Switching between the NORMAL2 and SLOW Modes SET (SYSCR2). 7 SET (SYSCR2). 5 SLOW1 mode Instruction execution XEN SYSCK Highfrequency clock Lowfrequency clock Main system clock NORMAL2 mode Instruction execution XEN SYSCK Highfrequency clock Lowfrequency clock Main system clock (b) Switching to the NORMAL2 mode Warm up during SLOW2 mode CLR (SYSCR2). 5 (a) Switching to the SLOW mode SLOW2 mode CLR (SYSCR2). 7 NORMAL2 mode SLOW1 mode Turn off 2.2 System Clock Controller 2. Operational Description TMP86CM23AUG TMP86CM23AUG 2.3 Reset Circuit The TMP86CM23AUG has four types of reset generation procedures: An external reset input, an address trap reset, a watchdog timer reset and a system clock reset. Of these reset, the address trap reset, the watchdog timer and the system clock reset are a malfunction reset. When the malfunction reset request is detected, reset occurs during the maximum 24/fc[s]. The malfunction reset circuit such as watchdog timer reset, address trap reset and system clock reset is not initialized when power is turned on. Therefore, reset may occur during maximum 24/fc[s] (1.5µs at 16.0 MHz) when power is turned on. Table 2-3 shows on-chip hardware initialization by reset action. Table 2-3 Initializing Internal Status by Reset Action On-chip Hardware Initial Value Program counter (PC) (FFFEH) Stack pointer (SP) Not initialized General-purpose registers (W, A, B, C, D, E, H, L, IX, IY) (JF) Not initialized Zero flag (ZF) Not initialized Carry flag (CF) Not initialized Half carry flag (HF) Not initialized Sign flag (SF) Not initialized Overflow flag (VF) Not initialized (IMF) 0 (EF) 0 (IL) 0 Interrupt individual enable flags Interrupt latches 2.3.1 Initial Value Prescaler and divider of timing generator 0 Not initialized Jump status flag Interrupt master enable flag On-chip Hardware Watchdog timer Enable Output latches of I/O ports Refer to I/O port circuitry Control registers Refer to each of control register LCD data buffer Not initialized RAM Not initialized External Reset Input The RESET pin contains a Schmitt trigger (Hysteresis) with an internal pull-up resistor. When the RESET pin is held at “L” level for at least 3 machine cycles (12/fc [s]) with the power supply voltage within the operating voltage range and oscillation stable, a reset is applied and the internal state is initialized. When the RESET pin input goes high, the reset operation is released and the program execution starts at the vector address stored at addresses FFFEH to FFFFH. VDD RESET Internal reset Watchdog timer reset Malfunction reset output circuit Address trap reset System clock reset Figure 2-15 Reset Circuit Page 31 2. Operational Description 2.3 Reset Circuit TMP86CM23AUG 2.3.2 Address trap reset If the CPU should start looping for some cause such as noise and an attempt be made to fetch an instruction from the on-chip RAM (when WDTCR1<ATAS> is set to “1”), DBR or the SFR area, address trap reset will be generated. The reset time is maximum 24/fc[s] (1.5µs at 16.0 MHz). Note:The operating mode under address trapped is alternative of reset or interrupt. The address trap area is alternative. Instruction execution Reset release JP a Instruction at address r Address trap is occurred Internal reset maximum 24/fc [s] 4/fc to 12/fc [s] 16/fc [s] Note 1: Address “a” is in the SFR, DBR or on-chip RAM (WDTCR1<ATAS> = “1”) space. Note 2: During reset release, reset vector “r” is read out, and an instruction at address “r” is fetched and decoded. Figure 2-16 Address Trap Reset 2.3.3 Watchdog timer reset Refer to Section “Watchdog Timer”. 2.3.4 System clock reset If the condition as follows is detected, the system clock reset occurs automatically to prevent dead lock of the CPU. (The oscillation is continued without stopping.) - In case of clearing SYSCR2<XEN> and SYSCR2<XTEN> simultaneously to “0”. - In case of clearing SYSCR2<XEN> to “0”, when the SYSCR2<SYSCK> is “0”. - In case of clearing SYSCR2<XTEN> to “0”, when the SYSCR2<SYSCK> is “1”. The reset time is maximum 24/fc (1.5 µs at 16.0 MHz). Page 32 TMP86CM23AUG Page 33 2. Operational Description 2.3 Reset Circuit TMP86CM23AUG Page 34 TMP86CM23AUG 3. Interrupt Control Circuit The TMP86CM23AUG has a total of 20 interrupt sources excluding reset. Interrupts can be nested with priorities. Four of the internal interrupt sources are non-maskable while the rest are maskable. Interrupt sources are provided with interrupt latches (IL), which hold interrupt requests, and independent vectors. The interrupt latch is set to “1” by the generation of its interrupt request which requests the CPU to accept its interrupts. Interrupts are enabled or disabled by software using the interrupt master enable flag (IMF) and interrupt enable flag (EF). If more than one interrupts are generated simultaneously, interrupts are accepted in order which is dominated by hardware. However, there are no prioritized interrupt factors among non-maskable interrupts. Interrupt Factors Internal/External Enable Condition Interrupt Latch Vector Address Priority (Reset) Non-maskable – FFFE 1 Internal INTSWI (Software interrupt) Non-maskable – FFFC 2 Internal INTUNDEF (Executed the undefined instruction interrupt) Non-maskable – FFFC 2 Internal INTATRAP (Address trap interrupt) Non-maskable IL2 FFFA 2 Internal INTWDT (Watchdog timer interrupt) Non-maskable IL3 FFF8 2 External INT0 IMF• EF4 = 1, INT0EN = 1 IL4 FFF6 5 External INT1 IMF• EF5 = 1 IL5 FFF4 6 Internal INTTBT IMF• EF6 = 1 IL6 FFF2 7 Internal INTTC1 IMF• EF7 = 1 IL7 FFF0 8 Internal INTSIO IMF• EF8 = 1 IL8 FFEE 9 External INT2 IMF• EF9 = 1 IL9 FFEC 10 Internal INTRXD IMF• EF10 = 1 IL10 FFEA 11 Internal INTTXD IMF• EF11 = 1 IL11 FFE8 12 Internal INTTC4 IMF• EF12 = 1 IL12 FFE6 13 Internal INTTC6 IMF• EF13 = 1 IL13 FFE4 14 Internal INTRTC IMF• EF14 = 1 IL14 FFE2 15 Internal INTADC IMF• EF15 = 1 IL15 FFE0 16 Internal INTTC3 IMF• EF16 = 1 IL16 FFBE 17 External INT3 IMF• EF17 = 1 IL17 FFBC 18 Internal INTTC5 IMF• EF18 = 1 IL18 FFBA 19 External INT5 IMF• EF19 = 1 IL19 FFB8 20 - Reserved IMF• EF20 = 1 IL20 FFB6 21 - Reserved IMF• EF21 = 1 IL21 FFB4 22 - Reserved IMF• EF22 = 1 IL22 FFB2 23 - Reserved IMF• EF23 = 1 IL23 FFB0 24 Note 1: To use the address trap interrupt (INTATRAP), clear WDTCR1<ATOUT> to “0” (It is set for the “reset request” after reset is cancelled). For details, see “Address Trap”. Note 2: To use the watchdog timer interrupt (INTWDT), clear WDTCR1<WDTOUT> to "0" (It is set for the "Reset request" after reset is released). For details, see "Watchdog Timer". Note 3: If an INTADC interrupt request is generated while an interrupt with priority lower than the interrupt latch IL15 (INTADC) is being accepted, the INTADC interrupt latch may be cleared without the INTADC interrupt being processed. For details, refer to the corresponding notes in the chapter on the AD converter. 3.1 Interrupt latches (IL19 to IL2) An interrupt latch is provided for each interrupt source, except for a software interrupt and an executed the undefined instruction interrupt. When interrupt request is generated, the latch is set to “1”, and the CPU is requested to accept the interrupt if its interrupt is enabled. The interrupt latch is cleared to "0" immediately after accepting interrupt. All interrupt latches are initialized to “0” during reset. Page 35 3. Interrupt Control Circuit 3.2 Interrupt enable register (EIR) TMP86CM23AUG The interrupt latches are located on address 002EH, 003CH and 003DH in SFR area. Each latch can be cleared to "0" individually by instruction. However, IL2 and IL3 should not be cleared to "0" by software. For clearing the interrupt latch, load instruction should be used and then IL2 and IL3 should be set to "1". If the read-modify-write instructions such as bit manipulation or operation instructions are used, interrupt request would be cleared inadequately if interrupt is requested while such instructions are executed. Interrupt latches are not set to “1” by an instruction. Since interrupt latches can be read, the status for interrupt requests can be monitored by software. Note: In main program, before manipulating the interrupt enable flag (EF) or the interrupt latch (IL), be sure to clear IMF to "0" (Disable interrupt by DI instruction). Then set IMF newly again as required after operating on the EF or IL (Enable interrupt by EI instruction) In interrupt service routine, because the IMF becomes "0" automatically, clearing IMF need not execute normally on interrupt service routine. However, if using multiple interrupt on interrupt service routine, manipulating EF or IL should be executed before setting IMF="1". Example 1 :Clears interrupt latches ; IMF ← 0 DI LDW (ILL), 1110100000111111B ; IL12, IL10 to IL6 ← 0 ; IMF ← 1 EI Example 2 :Reads interrupt latchess WA, (ILL) ; W ← ILH, A ← ILL TEST (ILL). 7 ; if IL7 = 1 then jump JR F, SSET LD Example 3 :Tests interrupt latches 3.2 Interrupt enable register (EIR) The interrupt enable register (EIR) enables and disables the acceptance of interrupts, except for the non-maskable interrupts (Software interrupt, undefined instruction interrupt, address trap interrupt and watchdog interrupt). Nonmaskable interrupt is accepted regardless of the contents of the EIR. The EIR consists of an interrupt master enable flag (IMF) and the individual interrupt enable flags (EF). These registers are located on address 002CH, 003AH and 003BH in SFR area, and they can be read and written by an instructions (Including read-modify-write instructions such as bit manipulation or operation instructions). 3.2.1 Interrupt master enable flag (IMF) The interrupt enable register (IMF) enables and disables the acceptance of the whole maskable interrupt. While IMF = “0”, all maskable interrupts are not accepted regardless of the status on each individual interrupt enable flag (EF). By setting IMF to “1”, the interrupt becomes acceptable if the individuals are enabled. When an interrupt is accepted, IMF is cleared to “0” after the latest status on IMF is stacked. Thus the maskable interrupts which follow are disabled. By executing return interrupt instruction [RETI/RETN], the stacked data, which was the status before interrupt acceptance, is loaded on IMF again. The IMF is located on bit0 in EIRL (Address: 003AH in SFR), and can be read and written by an instruction. The IMF is normally set and cleared by [EI] and [DI] instruction respectively. During reset, the IMF is initialized to “0”. Page 36 TMP86CM23AUG 3.2.2 Individual interrupt enable flags (EF19 to EF4) Each of these flags enables and disables the acceptance of its maskable interrupt. Setting the corresponding bit of an individual interrupt enable flag to “1” enables acceptance of its interrupt, and setting the bit to “0” disables acceptance. During reset, all the individual interrupt enable flags (EF19 to EF4) are initialized to “0” and all maskable interrupts are not accepted until they are set to “1”. Note:In main program, before manipulating the interrupt enable flag (EF) or the interrupt latch (IL), be sure to clear IMF to "0" (Disable interrupt by DI instruction). Then set IMF newly again as required after operating on the EF or IL (Enable interrupt by EI instruction) In interrupt service routine, because the IMF becomes "0" automatically, clearing IMF need not execute normally on interrupt service routine. However, if using multiple interrupt on interrupt service routine, manipulating EF or IL should be executed before setting IMF="1". Example 1 :Enables interrupts individually and sets IMF ; IMF ← 0 DI LDW : (EIRL), 1110100010100000B ; EF15 to EF13, EF11, EF7, EF5 ← 1 Note: IMF should not be set. : ; IMF ← 1 EI Example 2 :C compiler description example unsigned int _io (3AH) EIRL; /* 3AH shows EIRL address */ _DI(); EIRL = 10100000B; : _EI(); Page 37 3. Interrupt Control Circuit 3.2 Interrupt enable register (EIR) TMP86CM23AUG Interrupt Latches (Initial value: 00000000 000000**) ILH,ILL (003DH, 003CH) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 IL15 IL14 IL13 IL12 IL11 IL10 IL9 IL8 IL7 IL6 IL5 IL4 IL3 IL2 ILH (003DH) 1 0 ILL (003CH) (Initial value: ****0000) ILE (002EH) 7 6 5 4 3 2 1 0 − − − − IL19 IL18 IL17 IL16 ILE (002EH) IL19 to IL2 at RD 0: No interrupt request Interrupt latches at WR 0: Clears the interrupt request 1: (Interrupt latch is not set.) 1: Interrupt request R/W Note 1: To clear any one of bits IL7 to IL4, be sure to write "1" into IL2 and IL3. Note 2: In main program, before manipulating the interrupt enable flag (EF) or the interrupt latch (IL), be sure to clear IMF to "0" (Disable interrupt by DI instruction). Then set IMF newly again as required after operating on the EF or IL (Enable interrupt by EI instruction) In interrupt service routine, because the IMF becomes "0" automatically, clearing IMF need not execute normally on interrupt service routine. However, if using multiple interrupt on interrupt service routine, manipulating EF or IL should be executed before setting IMF="1". Note 3: Do not clear IL with read-modify-write instructions such as bit operations. Interrupt Enable Registers (Initial value: 00000000 0000***0) EIRH,EIRL (003BH, 003AH) 15 14 13 EF15 EF14 EF13 12 11 10 9 8 7 6 5 EF12 EF11 EF10 EF9 EF8 EF7 EF6 EF5 EIRH (003BH) 4 3 2 1 EF4 0 IMF EIRL (003AH) (Initial value: ****0000) EIRE (002CH) 7 6 5 − − − 4 3 2 1 0 − EF19 EF18 EF17 EF16 EIRE (002CH) EF19 to EF4 Individual-interrupt enable flag (Specified for each bit) 0: 1: Disables the acceptance of each maskable interrupt. Enables the acceptance of each maskable interrupt. Interrupt master enable flag 0: 1: Disables the acceptance of all maskable interrupts Enables the acceptance of all maskable interrupts R/W IMF Note 1: *: Don’t care Note 2: Do not set IMF and the interrupt enable flag (EF15 to EF4) to “1” at the same time. Note 3: In main program, before manipulating the interrupt enable flag (EF) or the interrupt latch (IL), be sure to clear IMF to "0" (Disable interrupt by DI instruction). Then set IMF newly again as required after operating on the EF or IL (Enable interrupt by EI instruction) In interrupt service routine, because the IMF becomes "0" automatically, clearing IMF need not execute normally on interrupt service routine. However, if using multiple interrupt on interrupt service routine, manipulating EF or IL should be executed before setting IMF="1". Page 38 TMP86CM23AUG 3.3 Interrupt Sequence An interrupt request, which raised interrupt latch, is held, until interrupt is accepted or interrupt latch is cleared to “0” by resetting or an instruction. Interrupt acceptance sequence requires 8 machine cycles (2 µs @16 MHz) after the completion of the current instruction. The interrupt service task terminates upon execution of an interrupt return instruction [RETI] (for maskable interrupts) or [RETN] (for non-maskable interrupts). Figure 3-1 shows the timing chart of interrupt acceptance processing. 3.3.1 Interrupt acceptance processing is packaged as follows. a. The interrupt master enable flag (IMF) is cleared to “0” in order to disable the acceptance of any following interrupt. b. The interrupt latch (IL) for the interrupt source accepted is cleared to “0”. c. The contents of the program counter (PC) and the program status word, including the interrupt master enable flag (IMF), are saved (Pushed) on the stack in sequence of PSW + IMF, PCH, PCL. Meanwhile, the stack pointer (SP) is decremented by 3. d. The entry address (Interrupt vector) of the corresponding interrupt service program, loaded on the vector table, is transferred to the program counter. e. The instruction stored at the entry address of the interrupt service program is executed. Note:When the contents of PSW are saved on the stack, the contents of IMF are also saved. Interrupt service task 1-machine cycle Interrupt request Interrupt latch (IL) IMF Execute instruction PC SP Execute instruction a−1 a Execute instruction Interrupt acceptance a+1 b a b+1 b+2 b + 3 n−1 n−2 n Execute RETI instruction c+2 c+1 a n−2 n−1 n-3 a+1 a+2 n Note 1: a: Return address entry address, b: Entry address, c: Address which RETI instruction is stored Note 2: On condition that interrupt is enabled, it takes 38/fc [s] or 38/fs [s] at maximum (If the interrupt latch is set at the first machine cycle on 10 cycle instruction) to start interrupt acceptance processing since its interrupt latch is set. Figure 3-1 Timing Chart of Interrupt Acceptance/Return Interrupt Instruction Example: Correspondence between vector table address for INTTBT and the entry address of the interrupt service program Vector table address FFF2H 03H FFF3H D2H Entry address Vector D203H 0FH D204H 06H Figure 3-2 Vector table address,Entry address Page 39 Interrupt service program 3. Interrupt Control Circuit 3.3 Interrupt Sequence TMP86CM23AUG A maskable interrupt is not accepted until the IMF is set to “1” even if the maskable interrupt higher than the level of current servicing interrupt is requested. In order to utilize nested interrupt service, the IMF is set to “1” in the interrupt service program. In this case, acceptable interrupt sources are selectively enabled by the individual interrupt enable flags. To avoid overloaded nesting, clear the individual interrupt enable flag whose interrupt is currently serviced, before setting IMF to “1”. As for non-maskable interrupt, keep interrupt service shorten compared with length between interrupt requests; otherwise the status cannot be recovered as non-maskable interrupt would simply nested. 3.3.2 Saving/restoring general-purpose registers During interrupt acceptance processing, the program counter (PC) and the program status word (PSW, includes IMF) are automatically saved on the stack, but the accumulator and others are not. These registers are saved by software if necessary. When multiple interrupt services are nested, it is also necessary to avoid using the same data memory area for saving registers. The following methods are used to save/restore the generalpurpose registers. 3.3.2.1 Using PUSH and POP instructions If only a specific register is saved or interrupts of the same source are nested, general-purpose registers can be saved/restored using the PUSH/POP instructions. Example :Save/store register using PUSH and POP instructions PINTxx: PUSH WA ; Save WA register (interrupt processing) POP WA ; Restore WA register RETI ; RETURN Address (Example) SP b-5 A SP b-4 SP b-3 PCL W PCL PCH PCH PCH PSW PSW PSW At acceptance of an interrupt At execution of PUSH instruction PCL At execution of POP instruction b-2 b-1 SP b At execution of RETI instruction Figure 3-3 Save/store register using PUSH and POP instructions 3.3.2.2 Using data transfer instructions To save only a specific register without nested interrupts, data transfer instructions are available. Page 40 TMP86CM23AUG Example :Save/store register using data transfer instructions PINTxx: LD (GSAVA), A ; Save A register (interrupt processing) LD A, (GSAVA) ; Restore A register RETI ; RETURN Main task Interrupt service task Interrupt acceptance Saving registers Restoring registers Interrupt return Saving/Restoring general-purpose registers using PUSH/POP data transfer instruction Figure 3-4 Saving/Restoring General-purpose Registers under Interrupt Processing 3.3.3 Interrupt return Interrupt return instructions [RETI]/[RETN] perform as follows. [RETI]/[RETN] Interrupt Return 1. Program counter (PC) and program status word (PSW, includes IMF) are restored from the stack. 2. Stack pointer (SP) is incremented by 3. As for address trap interrupt (INTATRAP), it is required to alter stacked data for program counter (PC) to restarting address, during interrupt service program. Note:If [RETN] is executed with the above data unaltered, the program returns to the address trap area and INTATRAP occurs again.When interrupt acceptance processing has completed, stacked data for PCL and PCH are located on address (SP + 1) and (SP + 2) respectively. Example 1 :Returning from address trap interrupt (INTATRAP) service program PINTxx: POP WA ; Recover SP by 2 LD WA, Return Address ; PUSH WA ; Alter stacked data (interrupt processing) RETN ; RETURN Page 41 3. Interrupt Control Circuit 3.4 Software Interrupt (INTSW) TMP86CM23AUG Example 2 :Restarting without returning interrupt (In this case, PSW (Includes IMF) before interrupt acceptance is discarded.) PINTxx: INC SP ; Recover SP by 3 INC SP ; INC SP ; (interrupt processing) LD EIRL, data ; Set IMF to “1” or clear it to “0” JP Restart Address ; Jump into restarting address Interrupt requests are sampled during the final cycle of the instruction being executed. Thus, the next interrupt can be accepted immediately after the interrupt return instruction is executed. Note 1: It is recommended that stack pointer be return to rate before INTATRAP (Increment 3 times), if return interrupt instruction [RETN] is not utilized during interrupt service program under INTATRAP (such as Example 2). Note 2: When the interrupt processing time is longer than the interrupt request generation time, the interrupt service task is performed but not the main task. 3.4 Software Interrupt (INTSW) Executing the SWI instruction generates a software interrupt and immediately starts interrupt processing (INTSW is highest prioritized interrupt). Use the SWI instruction only for detection of the address error or for debugging. 3.4.1 Address error detection FFH is read if for some cause such as noise the CPU attempts to fetch an instruction from a non-existent memory address during single chip mode. Code FFH is the SWI instruction, so a software interrupt is generated and an address error is detected. The address error detection range can be further expanded by writing FFH to unused areas of the program memory. Address trap reset is generated in case that an instruction is fetched from RAM, DBR or SFR areas. 3.4.2 Debugging Debugging efficiency can be increased by placing the SWI instruction at the software break point setting address. 3.5 Undefined Instruction Interrupt (INTUNDEF) Taking code which is not defined as authorized instruction for instruction causes INTUNDEF. INTUNDEF is generated when the CPU fetches such a code and tries to execute it. INTUNDEF is accepted even if non-maskable interrupt is in process. Contemporary process is broken and INTUNDEF interrupt process starts, soon after it is requested. Note: The undefined instruction interrupt (INTUNDEF) forces CPU to jump into vector address, as software interrupt (SWI) does. 3.6 Address Trap Interrupt (INTATRAP) Fetching instruction from unauthorized area for instructions (Address trapped area) causes reset output or address trap interrupt (INTATRAP). INTATRAP is accepted even if non-maskable interrupt is in process. Contemporary process is broken and INTATRAP interrupt process starts, soon after it is requested. Note: The operating mode under address trapped, whether to be reset output or interrupt processing, is selected on watchdog timer control register (WDTCR). Page 42 TMP86CM23AUG 3.7 External Interrupts The TMP86CM23AUG has 5 external interrupt inputs. These inputs are equipped with digital noise reject circuits (Pulse inputs of less than a certain time are eliminated as noise). Edge selection is also possible with INT1 to INT3. The INT0/P63 pin can be configured as either an external interrupt input pin or an input/output port, and is configured as an input port during reset. Edge selection, noise reject control and INT0/P63 pin function selection are performed by the external interrupt control register (EINTCR). Source INT0 INT1 INT2 INT3 INT5 Pin INT0 INT1 INT2 INT3 INT5 Enable Conditions Release Edge Digital Noise Reject IMF EF4 INT0EN=1 Falling edge Pulses of less than 2/fc [s] are eliminated as noise. Pulses of 7/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. IMF EF5 = 1 Falling edge or Rising edge Pulses of less than 15/fc or 63/fc [s] are eliminated as noise. Pulses of 49/fc or 193/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. IMF EF9 = 1 Falling edge or Rising edge Pulses of less than 7/fc [s] are eliminated as noise. Pulses of 25/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. IMF EF17 = 1 Falling edge or Rising edge Pulses of less than 7/fc [s] are eliminated as noise. Pulses of 25/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. Falling edge Pulses of less than 2/fc [s] are eliminated as noise. Pulses of 7/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. IMF EF19 = 1 Note 1: In NORMAL1/2 or IDLE1/2 mode, if a signal with no noise is input on an external interrupt pin, it takes a maximum of "signal establishment time + 6/fs[s]" from the input signal's edge to set the interrupt latch. Note 2: When INT0EN = "0", IL4 is not set even if a falling edge is detected on the INT0 pin input. Note 3: When a pin with more than one function is used as an output and a change occurs in data or input/output status, an interrupt request signal is generated in a pseudo manner. In this case, it is necessary to perform appropriate processing such as disabling the interrupt enable flag. Page 43 3. Interrupt Control Circuit 3.7 External Interrupts TMP86CM23AUG External Interrupt Control Register EINTCR 7 6 5 4 3 2 1 (0037H) INT1NC INT0EN - - INT3ES INT2ES INT1ES 0 (Initial value: 00** 000*) INT1NC Noise reject time select 0: Pulses of less than 63/fc [s] are eliminated as noise 1: Pulses of less than 15/fc [s] are eliminated as noise R/W INT0EN P63/INT0 pin configuration 0: P63 input/output port 1: INT0 pin (Port P63 should be set to an input mode) R/W INT3 ES INT3 edge select 0: Rising edge 1: Falling edge R/W INT2 ES INT2 edge select 0: Rising edge 1: Falling edge R/W INT1 ES INT1 edge select 0: Rising edge 1: Falling edge R/W Note 1: fc: High-frequency clock [Hz], *: Don’t care Note 2: When the system clock frequency is switched between high and low or when the external interrupt control register (EINTCR) is overwritten, the noise canceller may not operate normally. It is recommended that external interrupts are disabled using the interrupt enable register (EIR). Note 3: The maximum time from modifying INT1NC until a noise reject time is changed is 26/fc. Page 44 TMP86CM23AUG 4. Special Function Register (SFR) The TMP86CM23AUG adopts the memory mapped I/O system, and all peripheral control and data transfers are performed through the special function register (SFR) or the data buffer register (DBR). The SFR is mapped on address 0000H to 003FH, DBR is mapped on address 0F80H to 0FFFH. This chapter shows the arrangement of the special function register (SFR) and data buffer register (DBR) for TMP86CM23AUG. 4.1 SFR Address Read Write 0000H Reserved 0001H P1DR 0002H P2DR 0003H P3DR 0004H P3OUTCR 0005H P5DR 0006H P6DR 0007H P7DR 0008H P8DR 0009H P1CR 000AH P5CR 000BH P6CR1 000CH P6CR2 000DH P7CR 000EH ADCCR1 000FH ADCCR2 0010H TREG1AL 0011H TREG1AM 0012H TREG1AH 0013H 0014H TREG1B TC1CR1 0015H 0016H TC1CR TC1CR2 TC1SR - 0017H RTCCR 0018H TC3CR 0019H TC4CR 001AH TC5CR 001BH TC6CR 001CH TTREG3 001DH TTREG4 001EH TTREG5 001FH TTREG6 0020H ADCDR2 0021H ADCDR1 - 0022H Reserved 0023H Reserved 0024H P8CR 0025H UARTSR Page 45 UARTCR1 4. Special Function Register (SFR) 4.1 SFR TMP86CM23AUG Address Read 0026H - Write UARTCR2 0027H LCDCR 0028H PWREG3 0029H PWREG4 002AH PWREG5 002BH PWREG6 002CH EIRE 002DH Reserved 002EH ILE 002FH Reserved 0030H Reserved 0031H Reserved 0032H Reserved 0033H Reserved 0034H - WDTCR1 0035H - WDTCR2 0036H TBTCR 0037H EINTCR 0038H SYSCR1 0039H SYSCR2 003AH EIRL 003BH EIRH 003CH ILL 003DH ILH 003EH Reserved 003FH PSW Note 1: Do not access reserved areas by the program. Note 2: − ; Cannot be accessed. Note 3: Write-only registers and interrupt latches cannot use the read-modify-write instructions (Bit manipulation instructions such as SET, CLR, etc. and logical operation instructions such as AND, OR, etc.). Page 46 TMP86CM23AUG 4.2 DBR Address Read Write 0F80H SEG1/0 0F81H SEG3/2 0F82H SEG5/4 0F83H SEG7/6 0F84H SEG9/8 0F85H SEG11/10 0F86H SEG13/12 0F87H SEG15/14 0F88H SEG17/16 0F89H SEG19/18 0F8AH SEG21/20 0F8BH SEG23/22 0F8CH SEG25/24 0F8DH SEG27/26 0F8EH SEG29/28 0F8FH SEG31/30 0F90H SIOBR0 0F91H SIOBR1 0F92H SIOBR2 0F93H SIOBR3 0F94H SIOBR4 0F95H SIOBR5 0F96H SIOBR6 0F97H SIOBR7 0F98H - SIOCR1 0F99H SIOSR SIOCR2 0F9AH - STOPCR 0F9BH RDBUF TDBUF 0F9CH P2PRD - 0F9DH P3PRD - 0F9EH P1LCR 0F9FH P5LCR Page 47 4. Special Function Register (SFR) 4.2 DBR TMP86CM23AUG Address Read Write 0FA0H P7LCR 0FA1H P8LCR 0FA2H Reserved 0FA3H Reserved 0FA4H 0FA5H MACCR MACSR - 0FA6H MPLDRL 0FA7H MPLDRH 0FA8H MPCDRL 0FA9H MPCDRH 0FAAH RCALDR1 MADDR1 0FABH RCALDR2 MADDR2 0FACH RCALDR3 MADDR3 0FADH RCALDR4 MADDR4 0FAEH Reserved 0FAFH Reserved 0FB0H Reserved 0FB1H Reserved 0FB2H Reserved 0FB3H Reserved 0FB4H Reserved 0FB5H Reserved 0FB6H Reserved 0FB7H Reserved 0FB8H Reserved 0FB9H Reserved 0FBAH Reserved 0FBBH Reserved 0FBCH Reserved 0FBDH Reserved 0FBEH Reserved 0FBFH Reserved Address Read 0FC0H Write Reserved : : : : 0FDFH Reserved Address Read 0FE0H Write Reserved : : : : 0FFFH Reserved Note 1: Do not access reserved areas by the program. Note 2: − ; Cannot be accessed. Note 3: Write-only registers and interrupt latches cannot use the read-modify-write instructions (Bit manipulation instructions such as SET, CLR, etc. and logical operation instructions such as AND, OR, etc.). Page 48 TMP86CM23AUG 6. Time Base Timer (TBT) The time base timer generates time base for key scanning, dynamic displaying, etc. It also provides a time base timer interrupt (INTTBT). 6.1 Time Base Timer 6.1.1 Configuration MPX fc/223 or fs/215 fc/221 or fs/213 fc/216 or fs/28 fc/214 or fs/26 fc/213 or fs/25 fc/212 or fs/24 fc/211 or fs/23 fc/29 or fs/2 Source clock IDLE0, SLEEP0 release request Falling edge detector INTTBT interrupt request 3 TBTCK TBTEN TBTCR Time base timer control register Figure 6-1 Time Base Timer configuration 6.1.2 Control Time Base Timer is controlled by Time Base Timer control register (TBTCR). Time Base Timer Control Register 7 TBTCR (0036H) 6 (DVOEN) TBTEN 5 (DVOCK) Time Base Timer enable / disable 4 3 (DV7CK) TBTEN 2 1 0 TBTCK (Initial Value: 0000 0000) 0: Disable 1: Enable NORMAL1/2, IDLE1/2 Mode TBTCK Time Base Timer interrupt Frequency select : [Hz] DV7CK = 0 DV7CK = 1 SLOW1/2 SLEEP1/2 Mode 000 fc/223 fs/215 fs/215 001 fc/221 fs/213 fs/213 010 fc/216 fs/28 – 011 fc/2 14 6 – 100 fc/213 fs/25 – 101 fc/2 12 4 – 110 fc/211 fs/23 – 111 9 fs/2 – fc/2 Note 1: fc; High-frequency clock [Hz], fs; Low-frequency clock [Hz], *; Don't care Page 65 fs/2 fs/2 R/W 6. Time Base Timer (TBT) 6.1 Time Base Timer TMP86CM23AUG Note 2: The interrupt frequency (TBTCK) must be selected with the time base timer disabled (TBTEN="0"). (The interrupt frequency must not be changed with the disable from the enable state.) Both frequency selection and enabling can be performed simultaneously. Example :Set the time base timer frequency to fc/216 [Hz] and enable an INTTBT interrupt. LD (TBTCR) , 00000010B ; TBTCK ← 010 LD (TBTCR) , 00001010B ; TBTEN ← 1 ; IMF ← 0 DI SET (EIRL) . 6 Table 6-1 Time Base Timer Interrupt Frequency ( Example : fc = 16.0 MHz, fs = 32.768 kHz ) Time Base Timer Interrupt Frequency [Hz] TBTCK 6.1.3 NORMAL1/2, IDLE1/2 Mode NORMAL1/2, IDLE1/2 Mode SLOW1/2, SLEEP1/2 Mode DV7CK = 0 DV7CK = 1 000 1.91 1 1 001 7.63 4 4 010 244.14 128 – 011 976.56 512 – 100 1953.13 1024 – 101 3906.25 2048 – 110 7812.5 4096 – 111 31250 16384 – Function An INTTBT ( Time Base Timer Interrupt ) is generated on the first falling edge of source clock ( The divider output of the timing generator which is selected by TBTCK. ) after time base timer has been enabled. The divider is not cleared by the program; therefore, only the first interrupt may be generated ahead of the set interrupt period ( Figure 6-2 ). Source clock TBTCR<TBTEN> INTTBT Interrupt period Enable TBT Figure 6-2 Time Base Timer Interrupt Page 66 TMP86CM23AUG 6.2 Divider Output (DVO) Approximately 50% duty pulse can be output using the divider output circuit, which is useful for piezoelectric buzzer drive. Divider output is from DVO pin. 6.2.1 Configuration Output latch D Data output Q DVO pin MPX A B C Y D S 2 fc/213 or fs/25 fc/212 or fs/24 fc/211 or fs/23 fc/210 or fs/22 Port output latch TBTCR<DVOEN> DVOCK DVOEN TBTCR DVO pin output Divider output control register (a) configuration (b) Timing chart Figure 6-3 Divider Output 6.2.2 Control The Divider Output is controlled by the Time Base Timer Control Register. Time Base Timer Control Register 7 TBTCR (0036H) DVOEN DVOEN 6 5 DVOCK 4 3 (DV7CK) (TBTEN) Divider output enable / disable 2 1 0 (TBTCK) (Initial value: 0000 0000) 0: Disable 1: Enable R/W DV7CK = 0 DV7CK = 1 SLOW1/2 SLEEP1/2 Mode 00 fc/213 fs/25 fs/25 01 fc/212 fs/24 fs/24 10 fc/211 fs/23 fs/23 11 fc/210 fs/22 fs/22 NORMAL1/2, IDLE1/2 Mode DVOCK Divider Output (DVO) frequency selection: [Hz] R/W Note: Selection of divider output frequency (DVOCK) must be made while divider output is disabled (DVOEN="0"). Also, in other words, when changing the state of the divider output frequency from enabled (DVOEN="1") to disable(DVOEN="0"), do not change the setting of the divider output frequency. Page 67 6. Time Base Timer (TBT) 6.2 Divider Output (DVO) TMP86CM23AUG Example :1.95 kHz pulse output (fc = 16.0 MHz) LD (TBTCR) , 00000000B ; DVOCK ← "00" LD (TBTCR) , 10000000B ; DVOEN ← "1" Table 6-2 Divider Output Frequency ( Example : fc = 16.0 MHz, fs = 32.768 kHz ) Divider Output Frequency [Hz] DVOCK NORMAL1/2, IDLE1/2 Mode DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 Mode 00 1.953 k 1.024 k 1.024 k 01 3.906 k 2.048 k 2.048 k 10 7.813 k 4.096 k 4.096 k 11 15.625 k 8.192 k 8.192 k Page 68 TMP86CM23AUG 7. Watchdog Timer (WDT) The watchdog timer is a fail-safe system to detect rapidly the CPU malfunctions such as endless loops due to spurious noises or the deadlock conditions, and return the CPU to a system recovery routine. The watchdog timer signal for detecting malfunctions can be programmed only once as “reset request” or “interrupt request”. Upon the reset release, this signal is initialized to “reset request”. When the watchdog timer is not used to detect malfunctions, it can be used as the timer to provide a periodic interrupt. Note: Care must be taken in system design since the watchdog timer functions are not be operated completely due to effect of disturbing noise. 7.1 Watchdog Timer Configuration Reset release 23 15 Binary counters Selector fc/2 or fs/2 fc/221 or fs/213 fc/219 or fs/211 fc/217 or fs/29 Clock Clear R Overflow 1 WDT output 2 S 2 Q Interrupt request Internal reset Q S R WDTEN WDTT Writing disable code Writing clear code WDTOUT Controller 0034H WDTCR1 0035H WDTCR2 Watchdog timer control registers Figure 7-1 Watchdog Timer Configuration Page 69 Reset request INTWDT interrupt request 7. Watchdog Timer (WDT) 7.2 Watchdog Timer Control TMP86CM23AUG 7.2 Watchdog Timer Control The watchdog timer is controlled by the watchdog timer control registers (WDTCR1 and WDTCR2). The watchdog timer is automatically enabled after the reset release. 7.2.1 Malfunction Detection Methods Using the Watchdog Timer The CPU malfunction is detected, as shown below. 1. Set the detection time, select the output, and clear the binary counter. 2. Clear the binary counter repeatedly within the specified detection time. If the CPU malfunctions such as endless loops or the deadlock conditions occur for some reason, the watchdog timer output is activated by the binary-counter overflow unless the binary counters are cleared. When WDTCR1<WDTOUT> is set to “1” at this time, the reset request is generated and then internal hardware is initialized. When WDTCR1<WDTOUT> is set to “0”, a watchdog timer interrupt (INTWDT) is generated. The watchdog timer temporarily stops counting in the STOP mode including the warm-up or IDLE/SLEEP mode, and automatically restarts (continues counting) when the STOP/IDLE/SLEEP mode is inactivated. Note:The watchdog timer consists of an internal divider and a two-stage binary counter. When the clear code 4EH is written, only the binary counter is cleared, but not the internal divider. The minimum binary-counter overflow time, that depends on the timing at which the clear code (4EH) is written to the WDTCR2 register, may be 3/ 4 of the time set in WDTCR1<WDTT>. Therefore, write the clear code using a cycle shorter than 3/4 of the time set to WDTCR1<WDTT>. Example :Setting the watchdog timer detection time to 221/fc [s], and resetting the CPU malfunction detection Within 3/4 of WDT detection time LD (WDTCR2), 4EH : Clears the binary counters. LD (WDTCR1), 00001101B : WDTT ← 10, WDTOUT ← 1 LD (WDTCR2), 4EH : Clears the binary counters (always clears immediately before and after changing WDTT). (WDTCR2), 4EH : Clears the binary counters. (WDTCR2), 4EH : Clears the binary counters. : : LD Within 3/4 of WDT detection time : : LD Page 70 TMP86CM23AUG Watchdog Timer Control Register 1 WDTCR1 (0034H) 7 WDTEN 6 5 4 3 (ATAS) (ATOUT) WDTEN Watchdog timer enable/disable 2 1 0 WDTT WDTOUT (Initial value: **11 1001) 0: Disable (Writing the disable code to WDTCR2 is required.) 1: Enable NORMAL1/2 mode WDTT WDTOUT Watchdog timer detection time [s] Watchdog timer output select DV7CK = 0 DV7CK = 1 SLOW1/2 mode 00 225/fc 217/fs 217/fs 01 223/fc 215/fs 215fs 10 221fc 213/fs 213fs 11 219/fc 211/fs 211/fs 0: Interrupt request 1: Reset request Write only Write only Write only Note 1: After clearing WDTOUT to “0”, the program cannot set it to “1”. Note 2: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *: Don’t care Note 3: WDTCR1 is a write-only register and must not be used with any of read-modify-write instructions. If WDTCR1 is read, a don’t care is read. Note 4: To activate the STOP mode, disable the watchdog timer or clear the counter immediately before entering the STOP mode. After clearing the counter, clear the counter again immediately after the STOP mode is inactivated. Note 5: To clear WDTEN, set the register in accordance with the procedures shown in “7.2.3 Watchdog Timer Disable”. Watchdog Timer Control Register 2 WDTCR2 (0035H) 7 6 5 4 3 2 1 0 (Initial value: **** ****) WDTCR2 Write Watchdog timer control code 4EH: Clear the watchdog timer binary counter (Clear code) B1H: Disable the watchdog timer (Disable code) D2H: Enable assigning address trap area Others: Invalid Write only Note 1: The disable code is valid only when WDTCR1<WDTEN> = 0. Note 2: *: Don’t care Note 3: The binary counter of the watchdog timer must not be cleared by the interrupt task. Note 4: Write the clear code 4EH using a cycle shorter than 3/4 of the time set in WDTCR1<WDTT>. 7.2.2 Watchdog Timer Enable Setting WDTCR1<WDTEN> to “1” enables the watchdog timer. Since WDTCR1<WDTEN> is initialized to “1” during reset, the watchdog timer is enabled automatically after the reset release. Page 71 7. Watchdog Timer (WDT) 7.2 Watchdog Timer Control 7.2.3 TMP86CM23AUG Watchdog Timer Disable To disable the watchdog timer, set the register in accordance with the following procedures. Setting the register in other procedures causes a malfunction of the microcontroller. 1. Set the interrupt master flag (IMF) to “0”. 2. Set WDTCR2 to the clear code (4EH). 3. Set WDTCR1<WDTEN> to “0”. 4. Set WDTCR2 to the disable code (B1H). Note:While the watchdog timer is disabled, the binary counters of the watchdog timer are cleared. Example :Disabling the watchdog timer : IMF ← 0 DI LD (WDTCR2), 04EH : Clears the binary counter LDW (WDTCR1), 0B101H : WDTEN ← 0, WDTCR2 ← Disable code Table 7-1 Watchdog Timer Detection Time (Example: fc = 16.0 MHz, fs = 32.768 kHz) Watchdog Timer Detection Time[s] WDTT 7.2.4 NORMAL1/2 mode DV7CK = 0 DV7CK = 1 SLOW mode 00 2.097 4 4 01 524.288 m 1 1 10 131.072 m 250 m 250 m 11 32.768 m 62.5 m 62.5 m Watchdog Timer Interrupt (INTWDT) When WDTCR1<WDTOUT> is cleared to “0”, a watchdog timer interrupt request (INTWDT) is generated by the binary-counter overflow. A watchdog timer interrupt is the non-maskable interrupt which can be accepted regardless of the interrupt master flag (IMF). When a watchdog timer interrupt is generated while the other interrupt including a watchdog timer interrupt is already accepted, the new watchdog timer interrupt is processed immediately and the previous interrupt is held pending. Therefore, if watchdog timer interrupts are generated continuously without execution of the RETN instruction, too many levels of nesting may cause a malfunction of the microcontroller. To generate a watchdog timer interrupt, set the stack pointer before setting WDTCR1<WDTOUT>. Example :Setting watchdog timer interrupt LD SP, 063FH : Sets the stack pointer LD (WDTCR1), 00001000B : WDTOUT ← 0 Page 72 TMP86CM23AUG 7.2.5 Watchdog Timer Reset When a binary-counter overflow occurs while WDTCR1<WDTOUT> is set to “1”, a watchdog timer reset request is generated. When a watchdog timer reset request is generated, the internal hardware is reset. The reset time is maximum 24/fc [s] (1.5 µs @ fc = 16.0 MHz). Note:When a watchdog timer reset is generated in the SLOW1 mode, the reset time is maximum 24/fc (high-frequency clock) since the high-frequency clock oscillator is restarted. However, when crystals have inaccuracies upon start of the high-frequency clock oscillator, the reset time should be considered as an approximate value because it has slight errors. 219/fc [s] 217/fc Clock Binary counter (WDTT=11) 1 2 3 0 1 2 3 0 Overflow INTWDT interrupt request (WDTCR1<WDTOUT>= "0") Internal reset A reset occurs (WDTCR1<WDTOUT>= "1") Write 4EH to WDTCR2 Figure 7-2 Watchdog Timer Interrupt Page 73 7. Watchdog Timer (WDT) 7.3 Address Trap TMP86CM23AUG 7.3 Address Trap The Watchdog Timer Control Register 1 and 2 share the addresses with the control registers to generate address traps. Watchdog Timer Control Register 1 7 WDTCR1 (0034H) 6 ATAS ATOUT 5 4 3 ATAS ATOUT (WDTEN) 2 1 (WDTT) 0 (WDTOUT) (Initial value: **11 1001) Select address trap generation in the internal RAM area 0: Generate no address trap 1: Generate address traps (After setting ATAS to “1”, writing the control code D2H to WDTCR2 is required) Select operation at address trap 0: Interrupt request 1: Reset request Write only Watchdog Timer Control Register 2 WDTCR2 (0035H) 7 5 4 3 2 1 0 (Initial value: **** ****) WDTCR2 7.3.1 6 Write Watchdog timer control code and address trap area control code D2H: Enable address trap area selection (ATRAP control code) 4EH: Clear the watchdog timer binary counter (WDT clear code) B1H: Disable the watchdog timer (WDT disable code) Others: Invalid Write only Selection of Address Trap in Internal RAM (ATAS) WDTCR1<ATAS> specifies whether or not to generate address traps in the internal RAM area. To execute an instruction in the internal RAM area, clear WDTCR1<ATAS> to “0”. To enable the WDTCR1<ATAS> setting, set WDTCR1<ATAS> and then write D2H to WDTCR2. Executing an instruction in the SFR or DBR area generates an address trap unconditionally regardless of the setting in WDTCR1<ATAS>. 7.3.2 Selection of Operation at Address Trap (ATOUT) When an address trap is generated, either the interrupt request or the reset request can be selected by WDTCR1<ATOUT>. 7.3.3 Address Trap Interrupt (INTATRAP) While WDTCR1<ATOUT> is “0”, if the CPU should start looping for some cause such as noise and an attempt be made to fetch an instruction from the on-chip RAM (while WDTCR1<ATAS> is “1”), DBR or the SFR area, address trap interrupt (INTATRAP) will be generated. An address trap interrupt is a non-maskable interrupt which can be accepted regardless of the interrupt master flag (IMF). When an address trap interrupt is generated while the other interrupt including an address trap interrupt is already accepted, the new address trap is processed immediately and the previous interrupt is held pending. Therefore, if address trap interrupts are generated continuously without execution of the RETN instruction, too many levels of nesting may cause a malfunction of the microcontroller. To generate address trap interrupts, set the stack pointer beforehand. Page 74 TMP86CM23AUG 7.3.4 Address Trap Reset While WDTCR1<ATOUT> is “1”, if the CPU should start looping for some cause such as noise and an attempt be made to fetch an instruction from the on-chip RAM (while WDTCR1<ATAS> is “1”), DBR or the SFR area, address trap reset will be generated. When an address trap reset request is generated, the internal hardware is reset. The reset time is maximum 24/fc [s] (1.5 µs @ fc = 16.0 MHz). Note:When an address trap reset is generated in the SLOW1 mode, the reset time is maximum 24/fc (high-frequency clock) since the high-frequency clock oscillator is restarted. However, when crystals have inaccuracies upon start of the high-frequency clock oscillator, the reset time should be considered as an approximate value because it has slight errors. Page 75 7. Watchdog Timer (WDT) 7.3 Address Trap TMP86CM23AUG Page 76 ECIN Pin ECNT Pin P33 Pin 2 SEG 1 1 WGPSCK S Y fs/215 or fc/223 fs/25 or fc/213 fs/23 or fc/211 fc/27 fc/23 fs fc Edge detector TC6OUT PWM6/PDO6/PPG6 fc/214 or fs/26 fc/213 or fs/25 C D E F G B A H C B A 1 TC1CR1 Frequency measurement mode Pulse width measurement mode TC1CR2 1 2 1 2 1 Timer/Event count modes 2 2 Y 3 S Y Window pulse generator TREG1B TC1CK TC1S A B C TC1M Page 77 TC1C Figure 8-1 Timer/Counter1 00 S 11 10 SEG SGP SGEDG WGPSCK TC6OUT fc/212 or fs/24 Y 2 CMP TREG1AL TREG1AM TREG1AH 18- bit up-counter CLEAR signal Edge detector SGEDG 1 TC1M 1 TC1SR 1 F/F INTTC1 TMP86CM23AUG 8. 18-Bit Timer/Counter (TC1) 8.1 Configuration 8. 18-Bit Timer/Counter (TC1) 8.2 Control TMP86CM23AUG 8.2 Control The Timer/counter 1 is controlled by timer/counter 1 control registers (TC1CR1/TC1CR2), an 18-bit timer register (TREG1A), and an 8-bit internal window gate pulse setting register (TREG1B). Timer register TREG1AH (0012H) R/W 7 6 5 4 3 2 − − − − − − 7 6 5 4 3 2 TREG1AM (0011H) R/W 0 (Initial value: ∗∗∗∗ ∗∗00) TREG1AH 1 0 TREG1AM 7 6 5 TREG1AL (0010H) R/W 4 (Initial value: 0000 0000) 3 2 1 0 TREG1AL 7 TREG1B (0013H) 1 6 5 4 (Initial value: 0000 0000) 3 2 Ta 1 0 Tb (Initial value: 0000 0000) NORMAL1/2,IDLE1/2 modes DV7CK=0 DV7CK=1 SLOW1/2, SLEEP1/2 modes (16 - Ta) × 212/fc (16 - Ta) × 24/fs (16 - Ta) × 24/fs (16 - Ta) × 2 /fc (16 - Ta) × 2 /fs (16 - Ta) × 25/fs (16 - Ta) × (16 - Ta) × 26/fs (16 - Ta) × 26/fs WGPSCK Ta Tb Setting "H" level period of the window gate pulse 00 01 10 Setting "L" level period of the window gate pulse 00 01 10 13 214/fc 5 (16 - Tb) × 212/fc (16 - Tb) × 24/fs (16 - Tb) × 24/fs (16 - Tb) × 213/fc (16 - Tb) × 25/fs (16 - Tb) × 25/fs (16 - Tb) × 214/fc (16 - Tb) × 26/fs (16 - Tb) × 26/fs Page 78 R/W TMP86CM23AUG Timer/counter 1 control register 1 7 TC1CR1 (0014H) 6 TC1C 5 4 3 TC1S 2 1 TC1CK 0 TC1M (Initial value: 1000 1000) TC1C Counter/overfow flag controll 0: 1: Clear Counter/overflow flag ( “1” is automatically set after clearing.) Not clear Counter/overflow flag R/W TC1S TC1 start control 00: 10: *1: Stop and counter clear and overflow flag clear Start Reserved R/W NORMAL1/2,IDLE1/2 modes TC1CK TC1 source clock select DV7CK="0" DV7CK="1" SLOW1/2 mode SLEEP1/2 mode fc fs fc fs fc - fc - fc/223 fs/215 fs/215 fs/215 13 fs/25 fs/25 fs/25 fc/211 fs/23 7 fc/2 fc/27 fc/23 fc/23 fs/23 - fs/23 - 000: 001: 010: 011: 100: 101: 110: fc/2 111: TC1M TC1 mode select 00: 01: 10: 11: R/W External clock (ECIN pin input) Timer/Event counter mode Reserved Pulse width measurement mode Frequency measurement mode R/W Note 1: fc; High-frequency clock [Hz] fs; Low-frequency clock [Hz] * ; Don’t care Note 2: Writing to the low-byte of the timer register 1A (TREG1AL, TREG1AM), the compare function is inhibited until the highbyte (TREG1AH) is written. Note 3: Set the mode and source clock, and edge (selection) when the TC1 stops (TC1S=00). Note 4: “fc” can be selected as the source clock only in the timer mode during SLOW mode and in the pulse width measurement mode during NORMAL 1/2 or IDLE 1/2 mode. Note 5: When a read instruction is executed to the timer register (TREG1A), the counter immediate value, not the register set value, is read out. Therefore it is impossible to read out the written value of TREG1A. To read the counter value, the read instruction should be executed when the counter stops to avoid reading unstable value. Note 6: Set the timer register (TREG1A) to ≥1. Note 7: When using the timer mode and pulse width measurement mode, set TC1CK (TC1 source clock select) to internal clock. Note 8: When using the event counter mode, set TC1CK (TC1 source clock select) to external clock. Note 9: Because the read value is different from the written value, do not use read-modify-write instructions to TREG1A. Note 10:fc/27, fc/23can not be used as source clock in SLOW/SLEEP mode. Note 11:The read data of bits 7 to 2 in TREG1AH are always “0”. (Data “1” can not be written.) Page 79 8. 18-Bit Timer/Counter (TC1) 8.2 Control TMP86CM23AUG Timer/Counter 1 control register 2 7 TC1CR2 (0015H) SEG SEG SGP SGEDG 6 5 SGP 4 3 SGEDG 2 WGPSCK 1 0 TC6OUT "0" External input clock (ECIN) edge select 0: 1: Counts at the falling edge Counts at the both (falling/rising) edges Window gate pulse select 00: 01: 10: 11: ECNT input Internal window gate pulse (TREG1B) PWM6/PDO6/PPG6 (TC6)output Reserved 0: 1: Interrupts at the falling edge Interrupts at the falling/rising edges Window gate pulse interrupt edge select NORMAL1/2,IDLE1/2 modes WGPSCK TC6OUT Window gate pulse source clock select TC6 output (PWM6/PDO6/PPG6) external output select 00: 01: 10: 11: 0: 1: (Initial value: 0000 000*) R/W R/W DV7CK="0" DV7CK="1" SLOW1/2 mode SLEEP1/2 mode 212/fc 24/fs 24/fs 24/fs 13 5 5 2 /fc 2 /fs 2 /fs 25/fs 214/fc Reserved 26/fs Reserved 26/fs Reserved 26/fs Reserved Output to P33 No output to P33 Note 1: fc; High-frequency clock [Hz] fs; Low-frequency clock [Hz] *; Don't care Note 2: Set the mode, source clock, and edge (selection) when the TC1 stops (TC1S = 00). Note 3: If there is no need to use PWM6/PDO6/PPG6 as window gate pulse of TC1 always write "0" to TC6OUT. Note 4: Make sure to write TC1CR2 "0" to bit 0 in TC1CR2. Note 5: When using the event counter mode or pulse width measurement mode, set SEG to "0". Page 80 R/W R/W TMP86CM23AUG TC1 status register TC1SR (0016H) 7 6 5 4 3 2 1 0 HECF HEOVF "0" "0" "0" "0" "0" "0" HECF HEOVF Operating Status monitor 0: 1: Stop (during Tb) or disable Under counting (during Ta) Counter overflow monitor 0: 1: No overflow Overflow status (Initial value: 0000 0000) Read only 8.3 Function TC1 has four operating modes. The timer mode of the TC1 is used at warm-up when switching form SLOW mode to NORMAL2 mode. 8.3.1 Timer mode In this mode, counting up is performed using the internal clock. The contents of TREGIA are compared with the contents of up-counter. If a match is found, an INTTC1 interrupt is generated, and the counter is cleared. Counting up resumes after the counter is cleared. Table 8-1 Source clock (internal clock) of Timer/Counter 1 Source Clock Resolution NORMAL1/2, IDLE1/2 Mode Maximum Time Setting SLOW Mode SLEEP Mode fc = 16 MHz fs =32.768 kHz fc = 16 MHz fs =32.768 kHz fs/215 [Hz] fs/215 [Hz] fs/215 [Hz] 0.52 s 1s 38.2 h 72.8 h fc/213 fs/25 fs/25 fs/25 512 ms 0.98 ms 2.2 min 4.3 min fc/211 fs/23 fs/23 fs/23 128 ms 244 ms 0.6 min 1.07 min fc/27 fc/27 - - 8 ms - 2.1 s - fc/23 fc/23 - - 0.5 ms - 131.1 ms - fc fc fc (Note) - 62.5 ns - 16.4 ms - fs fs - - - 30.5 ms - 8s DV7CK = 0 DV7CK = 1 fc/223 [Hz] Note: When fc is selected for the source clock in SLOW mode, the lower bits 11 of TREG1A is invalid, and a match of the upper bits 7 makes interrupts. Page 81 8. 18-Bit Timer/Counter (TC1) 8.3 Function TMP86CM23AUG Command Start Internal clock Up counter 0 TREG1A 1 2 3 4 n-1 n 0 1 2 3 4 5 6 n Match detect Counter clear INTTC1 interrupt Figure 8-2 Timing chart for timer mode 8.3.2 Event Counter mode It is a mode to count up at the falling edge of the ECIN pin input. When using this mode, set TC1CR1<TC1CK> to the external clock and then set TC1CR2<SEG> to “0” (Both edges can not be used). The countents of TREG1A are compared with the contents of up-counter. If a match is found, an INTTC1 interrupt is generated, and the counter is cleared. Counting up resumes for ECIN pin input edge each after the counter is cleared. The maximum applied frequency is fc/24 [Hz] in NORMAL 1/2 or IDLE 1/2 mode and fs/24[Hz] in SLOW or SLEEP mode . Two or more machine cycles are required for both the “H” and “L” levels of the pulse width. Start ECIN pin input Up counter TREG1A 0 1 2 n-1 n 0 1 n Match Detect Counter clear INTTC1 interrupt Figure 8-3 Event counter mode timing chart Page 82 2 TMP86CM23AUG 8.3.3 Pulse Width Measurement mode In this mode, pulse widths are counted on the falling edge of logical AND-ed pulse between ECIN pin input (window pulse) and the internal clock. When using this mode, set TC1CR1<TC1CK> to suitable internal clock and then set TC1CR2<SEG> to “0” (Both edges can not be used). An INTTC1 interrupt is generated when the ECIN input detects the falling edge of the window pulse or both rising and falling edges of the window pulse, that can be selected by TC1CR2<SGEDG>. The contents of TREG1A should be read while the count is stopped (ECIN pin is low), then clear the counter using TC1CR1<TC1C> (Normally, execute these process in the interrupt program). When the counter is not cleared by TC1CR1<TC1C>, counting-up resumes from previous stopping value. When up counter is counted up from 3FFFFH to 00000H, an overflow occurs. At that time, TC1SR<HEOVF> is set to “1”. TC1SR<HEOVF> remains the previous data until the counter is required to be cleared by TC1CR1<TC1C>. Note:In pulse width measurement mode, if TC1CR1<TC1S> is written to "00" while ECIN input is "1", INTTC1 interrupt occurs. According to the following step, when timer counter is stopped, INTTC1 interrupt latch should be cleared to "0". Example : TC1STOP : ¦ ¦ DI ; Clear IMF CLR (EIRL). 7 ; Clear bit7 of EIRL LD (TC1CR1), 00011010B ; Stop timer couter 1 LD (ILL), 01111111B ; Clear bit7 of ILL SET (EIRL). 7 ; Set bit7 of EIRL EI ; Set IMF ¦ ¦ Note 1: When SGEDG (window gate pulse interrupt edge select) is set to both edges and ECIN pin input is "1" in the pulse width measurement mode, an INTTC1 interrupt is generated by setting TC1S (TC1 start control) to "10" (start). Note 2: In the pulse width measurement mode, HECF (operating status monitor) cannot used. Note 3: Because the up counter is counted on the falling edge of logical AND-ed pulse (between ECIN pin input and the internal clock), if ECIN input becomes falling edge while internal source clock is "H" level, the up counter stops plus "1". Count Start Count Stop Count Start ECIN pin input Internal clock AND-ed pulse (Internal signal) Up counter 0 1 2 3 n-2 n-1 n n+1 0 Read Clear INTTC1 interrupt Interrupt TC1CR1<TC1C> Figure 8-4 Pulse width measurement mode timing chart Page 83 1 2 8. 18-Bit Timer/Counter (TC1) 8.3 Function TMP86CM23AUG 8.3.4 Frequency Measurement mode In this mode, the frequency of ECIN pin input pulse is measured. When using this mode, set TC1CR1<TC1CK> to the external clock. The edge of the ECIN input pulse is counted during “H” level of the window gate pulse selected by TC1CR2<SGP>. To use ECNT input as a window gate pulse, TC1CR2<SGP> should be set to “00”. An INTTC1 interrupt is generated on the falling edge or both the rising/falling edges of the window gate pulse, that can be selected by TC1CR2<SGEDG>. In the interrupt service program, read the contents of TREG1A while the count is stopped (window gate pulse is low), then clear the counter using TC1CR1<TC1C>. When the counter is not cleared, counting up resumes from previous stopping value. The window pulse status can be monitored by TC1SR<HECF>. When up counter is counted up from 3FFFFH to 00000H, an overflow occurs. At that time, TC1SR<HEOVF> is set to “1”. TC1SR<HEOVF> remains the previous data until the counter is required to be cleared by TC1CR1<TC1C>. Using TC6 output (PWM6/PDO6/PPG6) for the window gate pulse, external output of PWM6/PDO6/PPG6 to P33 can be controlled using TC1CR2<TC6OUT>. Zero-clearing TC1CR2<TC6OUT> outputs PWM6/PDO6/ PPG6 to P33; setting 1 in TC1CR2<TC6OUT> does not output PWM6/PDO6/PPG6 to P33. (TC1CR2<TC6OUT> is used to control output to P33 only. Thus, use the timer counter 6 control register to operate/stop PWM6/PDO6/PPG6.) When the internal window gate pulse is selected, the window gate pulse is set as follows. Table 8-2 Internal window gate pulse setting time NORMAL1/2,IDLE1/2 modes DV7CK=0 DV7CK=1 SLOW1/2, SLEEP1/2 modes WGPSCK Ta Tb Setting "H" level period of the window gate pulse 00 01 10 (16 - Ta) × 212/fc (16 - Ta) × 24/fs (16 - Ta) × 24/fs (16 - Ta) × (16 - Ta) × 25/fs (16 - Ta) × 25/fs (16 - Ta) × 2 /fc (16 - Ta) × 2 /fs (16 - Ta) × 26/fs Setting "L" level period of the window gate pulse 00 01 10 (16 - Tb) × 212/fc (16 - Tb) × 24/fs (16 - Tb) × 24/fs (16 - Tb) × 2 /fc (16 - Tb) × 2 /fs (16 - Tb) × 25/fs (16 - Tb) × (16 - Tb) × (16 - Tb) × 26/fs 213/fc 14 13 214/fc 6 5 26/fs R/W The internal window gate pulse consists of “H” level period (Ta) that is counting time and “L” level period (Tb) that is counting stop time. Ta or Tb can be individually set by TREG1B. One cycle contains Ta + Tb. Note 1: Because the internal window gate pulse is generated in synchronization with the internal divider, it may be delayed for a maximum of one cycle of the source clock (WGPSCK) immediately after start of the timer. Note 2: Set the internal window gate pulse when the timer counter is not operating or during the Tb period. When Tb is overwritten during the Tb period, the update is valid from the next Tb period. Note 3: In case of TC1CR2<SEG> = "1", if window gate pulse becomes falling edge, the up counter stops plus "1" regardless of ECIN input level. Therefore, if ECIN is always "H" or "L" level, count value becomes "1". Note 4: In case of TC1CR2<SEG> = "0", because the up counter is counted on the falling edge of logical AND-ed pulse (between ECIN pin input and window gate pulse), if window gate pulse becomes falling edge while ECIN input is "H" level, the up counter stops plus "1". Therefore, if ECIN input is always "H" level, count value becomes "1". Page 84 TMP86CM23AUG Table 8-3 Table Setting Ta and Tb (WGPSCK = 10, fc = 16 MHz) Setting Value Setting time Setting Value Setting time 0 16.38ms 8 8.19ms 1 15.36ms 9 7.17ms 2 14.34ms A 6.14ms 3 13.31ms B 5.12ms 4 12.29ms C 4.10ms 5 11.26ms D 3.07ms 6 10.24ms E 2.05ms 7 9.22ms F 1.02ms Table 8-4 Table Setting Ta and Tb (WGPSCK = 10, fs = 32.768 kHz) Setting Valuen Setting time Setting Value Setting time 0 31.25ms 8 15.63ms 1 29.30ms 9 13.67ms 2 27.34ms A 11.72ms 3 25.39ms B 9.77ms 4 23.44ms C 7.81ms 5 21.48ms D 5.86ms 6 19.53ms E 3.91ms 7 17.58ms F 1.95ms Page 85 8. 18-Bit Timer/Counter (TC1) 8.3 Function TMP86CM23AUG ECIN pin input Window gate pulse Ta Ta Tb AND-ed pulse (Internal signal) Up counter 0 1 2 3 4 5 6 0 1 2 3 4 5 6 Read Clear INTTC1 interrupt TC1CR1<TC1C> a) TC1CR2<SEG> = "0" TC1CR2<SEG> ECIN pin input Window gate pulse Up counter INTTC1 interrupt Ta 0 Ta Tb 1 2 3 4 5 6 7 8 9 10 11 12 13 0 1 2 3 4 5 6 7 8 9 10 11 12 Read Clear TC1CR1<TC1C> a) TC1CR2<SEG> = "1" Figure 8-5 Timing chart for the frequency measurement mode (Window gate pulse falling interrupt) Page 86 TMP86CM23AUG 9. 8-Bit TimerCounter (TC3, TC4) 9.1 Configuration PWM mode Overflow fc/211 or fs/23 7 fc/2 5 fc/2 fc/23 fs fc/2 fc TC4 pin A B C D E F G H Y A B INTTC4 interrupt request Clear Y 8-bit up-counter TC4S S PDO, PPG mode A B S 16-bit mode S TC4M TC4S TFF4 Toggle Q Set Clear Y 16-bit mode Timer, Event Counter mode S TC4CK PDO4/PWM4/ PPG4 pin Timer F/F4 A Y B TC4CR TTREG4 PWM, PPG mode PWREG4 DecodeEN PDO, PWM, PPG mode TFF4 16-bit mode TC3S PWM mode fc/211 or fs/23 fc/27 5 fc/2 3 fc/2 fs fc/2 fc TC3 pin Y 8-bit up-counter Overflow 16-bit mode PDO mode 16-bit mode Timer, Event Couter mode S TC3M TC3S TFF3 INTTC3 interrupt request Clear A B C D E F G H Toggle Q Set Clear PDO3/PWM3/ pin Timer F/F3 TC3CK TC3CR PWM mode TTREG3 DecodeEN PWREG3 TFF3 Figure 9-1 8-Bit TimerCounter 3, 4 Page 87 PDO, PWM mode 16-bit mode 9. 8-Bit TimerCounter (TC3, TC4) 9.1 Configuration TMP86CM23AUG 9.2 TimerCounter Control The TimerCounter 3 is controlled by the TimerCounter 3 control register (TC3CR) and two 8-bit timer registers (TTREG3, PWREG3). TimerCounter 3 Timer Register TTREG3 (001CH) R/W 7 PWREG3 (0028H) R/W 7 6 5 4 3 2 1 0 (Initial value: 1111 1111) 6 5 4 3 2 1 0 (Initial value: 1111 1111) Note 1: Do not change the timer register (TTREG3) setting while the timer is running. Note 2: Do not change the timer register (PWREG3) setting in the operating mode except the 8-bit and 16-bit PWM modes while the timer is running. TimerCounter 3 Control Register TC3CR (0018H) TFF3 7 TFF3 6 5 4 TC3CK Time F/F3 control 3 2 TC3S 0: 1: 1 0 TC3M (Initial value: 0000 0000) Clear Set R/W NORMAL1/2, IDLE1/2 mode TC3CK Operating clock selection [Hz] DV7CK = 0 DV7CK = 1 SLOW1/2 SLEEP1/2 mode 000 fc/211 fs/23 fs/23 001 fc/27 fc/27 – 010 fc/25 fc/25 – 011 fc/23 fc/23 – 100 fs fs fs 101 fc/2 fc/2 – 110 fc fc fc (Note 8) 111 TC3S TC3 start control 0: 1: 000: 001: TC3M TC3M operating mode select 010: 011: 1**: R/W TC3 pin input Operation stop and counter clear Operation start R/W 8-bit timer/event counter mode 8-bit programmable divider output (PDO) mode 8-bit pulse width modulation (PWM) output mode 16-bit mode (Each mode is selectable with TC4M.) Reserved R/W Note 1: fc: High-frequency clock [Hz] fs: Low-frequency clock[Hz] Note 2: Do not change the TC3M, TC3CK and TFF3 settings while the timer is running. Note 3: To stop the timer operation (TC3S= 1 → 0), do not change the TC3M, TC3CK and TFF3 settings. To start the timer operation (TC3S= 0 → 1), TC3M, TC3CK and TFF3 can be programmed. Note 4: To use the TimerCounter in the 16-bit mode, set the operating mode by programming TC4CR<TC4M>, where TC3M must be fixed to 011. Note 5: To use the TimerCounter in the 16-bit mode, select the source clock by programming TC3CK. Set the timer start control and timer F/F control by programming TC4CR<TC4S> and TC4CR<TFF4>, respectively. Note 6: The operating clock settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 9-1 and Table 9-2. Page 88 TMP86CM23AUG Note 7: The timer register settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 93. Note 8: The operating clock fc in the SLOW or SLEEP mode can be used only as the high-frequency warm-up mode. Page 89 9. 8-Bit TimerCounter (TC3, TC4) 9.1 Configuration TMP86CM23AUG The TimerCounter 4 is controlled by the TimerCounter 4 control register (TC4CR) and two 8-bit timer registers (TTREG4 and PWREG4). TimerCounter 4 Timer Register TTREG4 (001DH) R/W 7 PWREG4 (0029H) R/W 7 6 5 4 3 2 1 0 (Initial value: 1111 1111) 6 5 4 3 2 1 0 (Initial value: 1111 1111) Note 1: Do not change the timer register (TTREG4) setting while the timer is running. Note 2: Do not change the timer register (PWREG4) setting in the operating mode except the 8-bit and 16-bit PWM modes while the timer is running. TimerCounter 4 Control Register TC4CR (0019H) TFF4 7 TFF4 6 5 4 TC4CK Timer F/F4 control 3 2 TC4S 0: 1: 1 0 TC4M (Initial value: 0000 0000) Clear Set R/W NORMAL1/2, IDLE1/2 mode TC4CK Operating clock selection [Hz] DV7CK = 0 DV7CK = 1 SLOW1/2 SLEEP1/2 mode 000 fc/211 fs/23 fs/23 001 fc/27 fc/27 – 010 fc/25 fc/25 – 011 fc/2 3 3 – 100 fs fs fs 101 fc/2 fc/2 – 110 fc fc – 111 TC4S TC4 start control 0: 1: 000: 001: 010: TC4M TC4M operating mode select 011: 100: 101: 110: 111: fc/2 R/W TC4 pin input Operation stop and counter clear Operation start R/W 8-bit timer/event counter mode 8-bit programmable divider output (PDO) mode 8-bit pulse width modulation (PWM) output mode Reserved 16-bit timer/event counter mode Warm-up counter mode 16-bit pulse width modulation (PWM) output mode 16-bit PPG mode R/W Note 1: fc: High-frequency clock [Hz] fs: Low-frequency clock [Hz] Note 2: Do not change the TC4M, TC4CK and TFF4 settings while the timer is running. Note 3: To stop the timer operation (TC4S= 1 → 0), do not change the TC4M, TC4CK and TFF4 settings. To start the timer operation (TC4S= 0 → 1), TC4M, TC4CK and TFF4 can be programmed. Note 4: When TC4M= 1** (upper byte in the 16-bit mode), the source clock becomes the TC3 overflow signal regardless of the TC4CK setting. Note 5: To use the TimerCounter in the 16-bit mode, select the operating mode by programming TC4M, where TC3CR<TC3M> must be set to 011. Page 90 TMP86CM23AUG Note 6: To the TimerCounter in the 16-bit mode, select the source clock by programming TC3CR<TC3CK>. Set the timer start control and timer F/F control by programming TC4S and TFF4, respectively. Note 7: The operating clock settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 9-1 and Table 9-2. Note 8: The timer register settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 93. Table 9-1 Operating Mode and Selectable Source Clock (NORMAL1/2 and IDLE1/2 Modes) Operating mode fc/211 or fc/27 fc/25 fc/23 fs fc/2 fc TC3 pin input TC4 pin input fs/23 8-bit timer Ο Ο Ο Ο – – – – – 8-bit event counter – – – – – – – Ο Ο 8-bit PDO Ο Ο Ο Ο – – – – – 8-bit PWM Ο Ο Ο Ο Ο Ο Ο – – 16-bit timer Ο Ο Ο Ο – – – – – 16-bit event counter – – – – – – – Ο – Warm-up counter – – – – Ο – – – – 16-bit PWM Ο Ο Ο Ο Ο Ο Ο Ο – 16-bit PPG Ο Ο Ο Ο – – – Ο – Note 1: For 16-bit operations (16-bit timer/event counter, warm-up counter, 16-bit PWM and 16-bit PPG), set its source clock on lower bit (TC3CK). Note 2: Ο : Available source clock Table 9-2 Operating Mode and Selectable Source Clock (SLOW1/2 and SLEEP1/2 Modes) Operating mode fc/211 or fc/27 fc/25 fc/23 fs fc/2 fc TC3 pin input TC4 pin input fs/23 8-bit timer Ο – – – – – – – – 8-bit event counter – – – – – – – Ο Ο 8-bit PDO Ο – – – – – – – – 8-bit PWM Ο – – – Ο – – – – 16-bit timer Ο – – – – – – – – 16-bit event counter – – – – – – – Ο – Warm-up counter – – – – – – Ο – – 16-bit PWM Ο – – – Ο – – Ο – 16-bit PPG Ο – – – – – – Ο – Note1: For 16-bit operations (16-bit timer/event counter, warm-up counter, 16-bit PWM and 16-bit PPG), set its source clock on lower bit (TC3CK). Note2: Ο : Available source clock Page 91 9. 8-Bit TimerCounter (TC3, TC4) 9.1 Configuration TMP86CM23AUG Table 9-3 Constraints on Register Values Being Compared Operating mode Register Value 8-bit timer/event counter 1≤ (TTREGn) ≤255 8-bit PDO 1≤ (TTREGn) ≤255 8-bit PWM 2≤ (PWREGn) ≤254 16-bit timer/event counter 1≤ (TTREG4, 3) ≤65535 Warm-up counter 256≤ (TTREG4, 3) ≤65535 16-bit PWM 2≤ (PWREG4, 3) ≤65534 16-bit PPG and (PWREG4, 3) + 1 < (TTREG4, 3) 1≤ (PWREG4, 3) < (TTREG4, 3) ≤65535 Note: n = 3 to 4 Page 92 TMP86CM23AUG 9.3 Function The TimerCounter 3 and 4 have the 8-bit timer, 8-bit event counter, 8-bit programmable divider output (PDO), 8bit pulse width modulation (PWM) output modes. The TimerCounter 3 and 4 (TC3, 4) are cascadable to form a 16bit timer. The 16-bit timer has the operating modes such as the 16-bit timer, 16-bit event counter, warm-up counter, 16-bit pulse width modulation (PWM) output and 16-bit programmable pulse generation (PPG) modes. 9.3.1 8-Bit Timer Mode (TC3 and 4) In the timer mode, the up-counter counts up using the internal clock. When a match between the up-counter and the timer register j (TTREGj) value is detected, an INTTCj interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting. Note 1: In the timer mode, fix TCjCR<TFFj> to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the timer mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the timer mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 3, 4 Table 9-4 Source Clock for TimerCounter 3, 4 (Internal Clock) Source Clock NORMAL1/2, IDLE1/2 mode Resolution Maximum Time Setting DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 mode fc/211 [Hz] fs/23 [Hz] fs/23 [Hz] 128 µs 244.14 µs 32.6 ms 62.3 ms fc/27 fc/27 – 8 µs – 2.0 ms – fc/25 fc/25 – 2 µs – 510 µs – fc/23 fc/23 – 500 ns – 127.5 µs – fc = 16 MHz fs = 32.768 kHz fc = 16 MHz fs = 32.768 kHz Example :Setting the timer mode with source clock fc/27 Hz and generating an interrupt 80 µs later (TimerCounter4, fc = 16.0 MHz) (TTREG4), 0AH : Sets the timer register (80 µs÷27/fc = 0AH). (EIRH). 4 : Enables INTTC4 interrupt. LD (TC4CR), 00010000B : Sets the operating clock to fc/27, and 8-bit timer mode. LD (TC4CR), 00011000B : Starts TC4. LD DI SET EI Page 93 9. 8-Bit TimerCounter (TC3, TC4) 9.1 Configuration TMP86CM23AUG TC4CR<TC4S> Internal Source Clock 1 Counter TTREG4 ? 2 3 n-1 n 0 1 2 n-1 n 0 1 2 0 n Match detect Counter clear INTTC4 interrupt request Counter clear Match detect Figure 9-2 8-Bit Timer Mode Timing Chart (TC4) 9.3.2 8-Bit Event Counter Mode (TC3, 4) In the 8-bit event counter mode, the up-counter counts up at the falling edge of the input pulse to the TCj pin. When a match between the up-counter and the TTREGj value is detected, an INTTCj interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting at the falling edge of the input pulse to the TCj pin. Two machine cycles are required for the low- or high-level pulse input to the TCj pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/24 Hz in the SLOW1/2 or SLEEP1/2 mode. Note 1: In the event counter mode, fix TCjCR<TFFj> to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the event counter mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the event counter mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 3, 4 TC4CR<TC4S> TC4 pin input 0 Counter TTREG4 ? 1 2 n-1 n 0 1 2 n-1 n 0 1 2 0 n Match detect INTTC4 interrupt request Counter clear Match detect Counter clear Figure 9-3 8-Bit Event Counter Mode Timing Chart (TC4) 9.3.3 8-Bit Programmable Divider Output (PDO) Mode (TC3, 4) This mode is used to generate a pulse with a 50% duty cycle from the PDOj pin. In the PDO mode, the up-counter counts up using the internal clock. When a match between the up-counter and the TTREGj value is detected, the logic level output from the PDOj pin is switched to the opposite state and the up-counter is cleared. The INTTCj interrupt request is generated at the time. The logic state opposite to the timer F/Fj logic level is output from the PDOj pin. An arbitrary value can be set to the timer F/Fj by TCjCR<TFFj>. Upon reset, the timer F/Fj value is initialized to 0. To use the programmable divider output, set the output latch of the I/O port to 1. Page 94 TMP86CM23AUG Example :Generating 1024 Hz pulse using TC4 (fc = 16.0 MHz) Setting port LD (TTREG4), 3DH : 1/1024÷27/fc÷2 = 3DH LD (TC4CR), 00010001B : Sets the operating clock to fc/27, and 8-bit PDO mode. LD (TC4CR), 00011001B : Starts TC4. Note 1: In the programmable divider output mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the programmable divider output mode, the new value programmed in TTREGj is in effect immediately after programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 2: When the timer is stopped during PDO output, the PDOj pin holds the output status when the timer is stopped. To change the output status, program TCjCR<TFFj> after the timer is stopped. Do not change the TCjCR<TFFj> setting upon stopping of the timer. Example: Fixing the PDOj pin to the high level when the TimerCounter is stopped CLR (TCjCR).3: Stops the timer. CLR (TCjCR).7: Sets the PDOj pin to the high level. Note 3: j = 3, 4 Page 95 Page 96 ? INTTC4 interrupt request PDO4 pin Timer F/F4 TTREG4 Counter Internal source clock TC4CR<TFF4> TC4CR<TC4S> 0 n 1 Match detect 2 n 0 1 Match detect 2 n 0 1 Match detect 2 n 0 1 Match detect 2 n 0 1 2 3 Set F/F Held at the level when the timer is stopped 0 Write of "1" 9.1 Configuration 9. 8-Bit TimerCounter (TC3, TC4) TMP86CM23AUG Figure 9-4 8-Bit PDO Mode Timing Chart (TC4) TMP86CM23AUG 9.3.4 8-Bit Pulse Width Modulation (PWM) Output Mode (TC3, 4) This mode is used to generate a pulse-width modulated (PWM) signals with up to 8 bits of resolution. The up-counter counts up using the internal clock. When a match between the up-counter and the PWREGj value is detected, the logic level output from the timer F/Fj is switched to the opposite state. The counter continues counting. The logic level output from the timer F/Fj is switched to the opposite state again by the up-counter overflow, and the counter is cleared. The INTTCj interrupt request is generated at this time. Since the initial value can be set to the timer F/Fj by TCjCR<TFFj>, positive and negative pulses can be generated. Upon reset, the timer F/Fj is cleared to 0. (The logic level output from the PWMj pin is the opposite to the timer F/Fj logic level.) Since PWREGj in the PWM mode is serially connected to the shift register, the value set to PWREGj can be changed while the timer is running. The value set to PWREGj during a run of the timer is shifted by the INTTCj interrupt request and loaded into PWREGj. While the timer is stopped, the value is shifted immediately after the programming of PWREGj. If executing the read instruction to PWREGj during PWM output, the value in the shift register is read, but not the value set in PWREGj. Therefore, after writing to PWREGj, the reading data of PWREGj is previous value until INTTCj is generated. For the pin used for PWM output, the output latch of the I/O port must be set to 1. Note 1: In the PWM mode, program the timer register PWREGj immediately after the INTTCj interrupt request is generated (normally in the INTTCj interrupt service routine.) If the programming of PWREGj and the interrupt request occur at the same time, an unstable value is shifted, that may result in generation of the pulse different from the programmed value until the next INTTCj interrupt request is generated. Note 2: When the timer is stopped during PWM output, the PWMj pin holds the output status when the timer is stopped. To change the output status, program TCjCR<TFFj> after the timer is stopped. Do not change the TCjCR<TFFj> upon stopping of the timer. Example: Fixing the PWMj pin to the high level when the TimerCounter is stopped CLR (TCjCR).3: Stops the timer. CLR (TCjCR).7: Sets the PWMj pin to the high level. Note 3: To enter the STOP mode during PWM output, stop the timer and then enter the STOP mode. If the STOP mode is entered without stopping the timer when fc, fc/2 or fs is selected as the source clock, a pulse is output from the PWMj pin during the warm-up period time after exiting the STOP mode. Note 4: j = 3, 4 Table 9-5 PWM Output Mode Source Clock NORMAL1/2, IDLE1/2 mode Resolution Repeated Cycle DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 mode fc/211 [Hz] fs/23 [Hz] fs/23 [Hz] 128 µs 244.14 µs 32.8 ms 62.5 ms fc/2 7 – 8 µs – 2.05 ms – fc/2 5 – 2 µs – 512 µs – fc/2 7 fc/2 5 fc = 16 MHz fs = 32.768 kHz fc = 16 MHz fs = 32.768 kHz fc/23 fc/23 – 500 ns – 128 µs – fs fs fs 30.5 µs 30.5 µs 7.81 ms 7.81 ms fc/2 fc/2 – 125 ns – 32 µs – fc fc – 62.5 ns – 16 µs – Page 97 Page 98 ? Shift registar 0 Shift INTTC4 interrupt request PWM4 pin Timer F/F4 ? PWREG4 Counter Internal source clock TC4CR<TFF4> TC4CR<TC4S> n n n Match detect 1 n n+1 Shift FF 0 n n n+1 m One cycle period Write to PWREG4 Match detect 1 Shift FF 0 m m m+1 Write to PWREG4 p Match detect m 1 Shift FF 0 p p Match detect 1 p 9.1 Configuration 9. 8-Bit TimerCounter (TC3, TC4) TMP86CM23AUG Figure 9-5 8-Bit PWM Mode Timing Chart (TC4) TMP86CM23AUG 9.3.5 16-Bit Timer Mode (TC3 and 4) In the timer mode, the up-counter counts up using the internal clock. The TimerCounter 3 and 4 are cascadable to form a 16-bit timer. When a match between the up-counter and the timer register (TTREG3, TTREG4) value is detected after the timer is started by setting TC4CR<TC4S> to 1, an INTTC4 interrupt is generated and the up-counter is cleared. After being cleared, the up-counter continues counting. Program the lower byte and upper byte in this order in the timer register. (Programming only the upper or lower byte should not be attempted.) Note 1: In the timer mode, fix TCjCR<TFFj> to 0. If not fixed, the PDOj, PWMj, and PPGj pins may output a pulse. Note 2: In the timer mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the timer mode, the new value programmed in TTREGj is in effect immediately after programming of TTREGj. Therefore, if TTREGj is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 3, 4 Table 9-6 Source Clock for 16-Bit Timer Mode Source Clock Resolution NORMAL1/2, IDLE1/2 mode Maximum Time Setting DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 mode fc/211 fs/23 fs/23 128 µs 244.14 µs 8.39 s 16 s fc/27 fc/27 – 8 µs – 524.3 ms – fc/25 fc/25 – 2 µs – 131.1 ms – fc/23 fc/23 – 500 ns – 32.8 ms – fc = 16 MHz fs = 32.768 kHz fc = 16 MHz fs = 32.768 kHz Example :Setting the timer mode with source clock fc/27 Hz, and generating an interrupt 300 ms later (fc = 16.0 MHz) (TTREG3), 927CH : Sets the timer register (300 ms÷27/fc = 927CH). (EIRH). 4 : Enables INTTC4 interrupt. LD (TC3CR), 13H :Sets the operating clock to fc/27, and 16-bit timer mode (lower byte). LD (TC4CR), 04H : Sets the 16-bit timer mode (upper byte). LD (TC4CR), 0CH : Starts the timer. LDW DI SET EI TC4CR<TC4S> Internal source clock 0 Counter TTREG3 (Lower byte) TTREG4 (Upper byte) ? ? INTTC4 interrupt request 1 2 3 mn-1 mn 0 1 2 mn-1 mn 0 1 n m Match detect Counter clear Match detect Counter clear Figure 9-6 16-Bit Timer Mode Timing Chart (TC3 and TC4) Page 99 2 0 9. 8-Bit TimerCounter (TC3, TC4) 9.1 Configuration 9.3.6 TMP86CM23AUG 16-Bit Event Counter Mode (TC3 and 4) In the event counter mode, the up-counter counts up at the falling edge to the TC3 pin. The TimerCounter 3 and 4 are cascadable to form a 16-bit event counter. When a match between the up-counter and the timer register (TTREG3, TTREG4) value is detected after the timer is started by setting TC4CR<TC4S> to 1, an INTTC4 interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting at the falling edge of the input pulse to the TC3 pin. Two machine cycles are required for the low- or high-level pulse input to the TC3 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/ 2 in the SLOW1/2 or SLEEP1/2 mode. Program the lower byte (TTREG3), and upper byte (TTREG4) in this order in the timer register. (Programming only the upper or lower byte should not be attempted.) 4 Note 1: In the event counter mode, fix TCjCR<TFFj> to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the event counter mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the event counter mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGj is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 3, 4 9.3.7 16-Bit Pulse Width Modulation (PWM) Output Mode (TC3 and 4) This mode is used to generate a pulse-width modulated (PWM) signals with up to 16 bits of resolution. The TimerCounter 3 and 4 are cascadable to form the 16-bit PWM signal generator. The counter counts up using the internal clock or external clock. When a match between the up-counter and the timer register (PWREG3, PWREG4) value is detected, the logic level output from the timer F/F4 is switched to the opposite state. The counter continues counting. The logic level output from the timer F/F4 is switched to the opposite state again by the counter overflow, and the counter is cleared. The INTTC4 interrupt is generated at this time. Two machine cycles are required for the high- or low-level pulse input to the TC3 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/24 to in the SLOW1/2 or SLEEP1/2 mode. Since the initial value can be set to the timer F/F4 by TC4CR<TFF4>, positive and negative pulses can be generated. Upon reset, the timer F/F4 is cleared to 0. (The logic level output from the PWM4 pin is the opposite to the timer F/F4 logic level.) Since PWREG4 and 3 in the PWM mode are serially connected to the shift register, the values set to PWREG4 and 3 can be changed while the timer is running. The values set to PWREG4 and 3 during a run of the timer are shifted by the INTTCj interrupt request and loaded into PWREG4 and 3. While the timer is stopped, the values are shifted immediately after the programming of PWREG4 and 3. Set the lower byte (PWREG3) and upper byte (PWREG4) in this order to program PWREG4 and 3. (Programming only the lower or upper byte of the register should not be attempted.) If executing the read instruction to PWREG4 and 3 during PWM output, the values set in the shift register is read, but not the values set in PWREG4 and 3. Therefore, after writing to the PWREG4 and 3, reading data of PWREG4 and 3 is previous value until INTTC4 is generated. For the pin used for PWM output, the output latch of the I/O port must be set to 1. Note 1: In the PWM mode, program the timer register PWREG4 and 3 immediately after the INTTC4 interrupt request is generated (normally in the INTTC4 interrupt service routine.) If the programming of PWREGj and the interrupt request occur at the same time, an unstable value is shifted, that may result in generation of pulse different from the programmed value until the next INTTC4 interrupt request is generated. Note 2: When the timer is stopped during PWM output, the PWM4 pin holds the output status when the timer is stopped. To change the output status, program TC4CR<TFF4> after the timer is stopped. Do not program TC4CR<TFF4> upon stopping of the timer. Example: Fixing the PWM4 pin to the high level when the TimerCounter is stopped Page 100 TMP86CM23AUG CLR (TC4CR).3: Stops the timer. CLR (TC4CR).7 : Sets the PWM4 pin to the high level. Note 3: To enter the STOP mode, stop the timer and then enter the STOP mode. If the STOP mode is entered without stopping of the timer when fc, fc/2 or fs is selected as the source clock, a pulse is output from the PWM4 pin during the warm-up period time after exiting the STOP mode. Table 9-7 16-Bit PWM Output Mode Source Clock NORMAL1/2, IDLE1/2 mode Resolution Repeated Cycle DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 mode fc/211 fs/23 [Hz] fs/23 [Hz] 128 µs 244.14 µs 8.39 s 16 s fc/27 fc/27 – 8 µs – 524.3 ms – fc/25 fc/25 – 2 µs – 131.1 ms – fc/23 fc/23 – 500 ns – 32.8 ms – fc = 16 MHz fs = 32.768 kHz fc = 16 MHz fs = 32.768 kHz fs fs fs 30.5 µs 30.5 µs 2s 2s fc/2 fc/2 – 125 ns – 8.2 ms – fc fc – 62.5 ns – 4.1 ms – Example :Generating a pulse with 1-ms high-level width and a period of 32.768 ms (fc = 16.0 MHz) Setting ports LDW (PWREG3), 07D0H : Sets the pulse width. LD (TC3CR), 33H : Sets the operating clock to fc/23, and 16-bit PWM output mode (lower byte). LD (TC4CR), 056H : Sets TFF4 to the initial value 0, and 16-bit PWM signal generation mode (upper byte). LD (TC4CR), 05EH : Starts the timer. Page 101 Page 102 ? ? PWREG4 (Upper byte) 16-bit shift register 0 a Shift INTTC4 interrupt request PWM4 pin Timer F/F4 ? PWREG3 (Lower byte) Counter Internal source clock TC4CR<TFF4> TC4CR<TC4S> an n an Match detect 1 an an+1 Shift FFFF 0 an an an+1 m b One cycle period Write to PWREG4 Write to PWREG3 Match detect 1 Shift FFFF 0 bm bm bm+1 p c Write to PWREG4 Write to PWREG3 Match detect bm 1 Shift FFFF 0 cp Match detect cp 1 cp 9.1 Configuration 9. 8-Bit TimerCounter (TC3, TC4) TMP86CM23AUG Figure 9-7 16-Bit PWM Mode Timing Chart (TC3 and TC4) TMP86CM23AUG 9.3.8 16-Bit Programmable Pulse Generate (PPG) Output Mode (TC3 and 4) This mode is used to generate pulses with up to 16-bits of resolution. The timer counter 3 and 4 are cascadable to enter the 16-bit PPG mode. The counter counts up using the internal clock or external clock. When a match between the up-counter and the timer register (PWREG3, PWREG4) value is detected, the logic level output from the timer F/F4 is switched to the opposite state. The counter continues counting. The logic level output from the timer F/F4 is switched to the opposite state again when a match between the up-counter and the timer register (TTREG3, TTREG4) value is detected, and the counter is cleared. The INTTC4 interrupt is generated at this time. Two machine cycles are required for the high- or low-level pulse input to the TC3 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/24 to in the SLOW1/ 2 or SLEEP1/2 mode. Since the initial value can be set to the timer F/F4 by TC4CR<TFF4>, positive and negative pulses can be generated. Upon reset, the timer F/F4 is cleared to 0. (The logic level output from the PPG4 pin is the opposite to the timer F/F4.) Set the lower byte and upper byte in this order to program the timer register. (TTREG3 → TTREG4, PWREG3 → PWREG4) (Programming only the upper or lower byte should not be attempted.) For PPG output, set the output latch of the I/O port to 1. Example :Generating a pulse with 1-ms high-level width and a period of 16.385 ms (fc = 16.0 MHz) Setting ports LDW (PWREG3), 07D0H : Sets the pulse width. LDW (TTREG3), 8002H : Sets the cycle period. LD (TC3CR), 33H : Sets the operating clock to fc/23, and16-bit PPG mode (lower byte). LD (TC4CR), 057H : Sets TFF4 to the initial value 0, and 16-bit PPG mode (upper byte). LD (TC4CR), 05FH : Starts the timer. Note 1: In the PPG mode, do not change the PWREGi and TTREGi settings while the timer is running. Since PWREGi and TTREGi are not in the shift register configuration in the PPG mode, the new values programmed in PWREGi and TTREGi are in effect immediately after programming PWREGi and TTREGi. Therefore, if PWREGi and TTREGi are changed while the timer is running, an expected operation may not be obtained. Note 2: When the timer is stopped during PPG output, the PPG4 pin holds the output status when the timer is stopped. To change the output status, program TC4CR<TFF4> after the timer is stopped. Do not change TC4CR<TFF4> upon stopping of the timer. Example: Fixing the PPG4 pin to the high level when the TimerCounter is stopped CLR (TC4CR).3: Stops the timer CLR (TC4CR).7: Sets the PPG4 pin to the high level Note 3: i = 3, 4 Page 103 Page 104 ? TTREG4 (Upper byte) INTTC4 interrupt request PPG4 pin Timer F/F4 ? ? TTREG3 (Lower byte) PWREG4 (Upper byte) n PWREG3 (Lower byte) ? 0 Counter Internal source clock TC4CR<TFF4> TC4CR<TC4S> m r q mn Match detect 1 mn mn+1 Match detect qr-1 qr 0 mn Match detect 1 mn mn+1 Match detect qr-1 qr 0 mn Match detect 1 F/F clear 0 Held at the level when the timer stops mn mn+1 Write of "0" 9.1 Configuration 9. 8-Bit TimerCounter (TC3, TC4) TMP86CM23AUG Figure 9-8 16-Bit PPG Mode Timing Chart (TC3 and TC4) TMP86CM23AUG 9.3.9 Warm-Up Counter Mode In this mode, the warm-up period time is obtained to assure oscillation stability when the system clocking is switched between the high-frequency and low-frequency. The timer counter 3 and 4 are cascadable to form a 16-bit TimerCounter. The warm-up counter mode has two types of mode; switching from the high-frequency to low-frequency, and vice-versa. Note 1: In the warm-up counter mode, fix TCiCR<TFFi> to 0. If not fixed, the PDOi, PWMi and PPGi pins may output pulses. Note 2: In the warm-up counter mode, only upper 8 bits of the timer register TTREG4 and 3 are used for match detection and lower 8 bits are not used. Note 3: i = 3, 4 9.3.9.1 Low-Frequency Warm-up Counter Mode (NORMAL1 → NORMAL2 → SLOW2 → SLOW1) In this mode, the warm-up period time from a stop of the low-frequency clock fs to oscillation stability is obtained. Before starting the timer, set SYSCR2<XTEN> to 1 to oscillate the low-frequency clock. When a match between the up-counter and the timer register (TTREG4, 3) value is detected after the timer is started by setting TC4CR<TC4S> to 1, the counter is cleared by generating the INTTC4 interrupt request. After stopping the timer in the INTTC4 interrupt service routine, set SYSCR2<SYSCK> to 1 to switch the system clock from the high-frequency to low-frequency, and then clear of SYSCR2<XEN> to 0 to stop the high-frequency clock. Table 9-8 Setting Time of Low-Frequency Warm-Up Counter Mode (fs = 32.768 kHz) Minimum Time Setting (TTREG4, 3 = 0100H) Maximum Time Setting (TTREG4, 3 = FF00H) 7.81 ms 1.99 s Example :After checking low-frequency clock oscillation stability with TC4 and 3, switching to the SLOW1 mode SET (SYSCR2).6 : SYSCR2<XTEN> ← 1 LD (TC3CR), 43H : Sets TFF3=0, source clock fs, and 16-bit mode. LD (TC4CR), 05H : Sets TFF4=0, and warm-up counter mode. LD (TTREG3), 8000H : Sets the warm-up time. (The warm-up time depends on the oscillator characteristic.) : IMF ← 0 DI SET (EIRH). 4 : IMF ← 1 EI SET : PINTTC4: : Enables the INTTC4. (TC4CR).3 : Starts TC4 and 3. : CLR (TC4CR).3 : Stops TC4 and 3. SET (SYSCR2).5 : SYSCR2<SYSCK> ← 1 (Switches the system clock to the low-frequency clock.) CLR (SYSCR2).7 : SYSCR2<XEN> ← 0 (Stops the high-frequency clock.) RETI : VINTTC4: DW : PINTTC4 : INTTC4 vector table Page 105 9. 8-Bit TimerCounter (TC3, TC4) 9.1 Configuration TMP86CM23AUG 9.3.9.2 High-Frequency Warm-Up Counter Mode (SLOW1 → SLOW2 → NORMAL2 → NORMAL1) In this mode, the warm-up period time from a stop of the high-frequency clock fc to the oscillation stability is obtained. Before starting the timer, set SYSCR2<XEN> to 1 to oscillate the high-frequency clock. When a match between the up-counter and the timer register (TTREG4, 3) value is detected after the timer is started by setting TC4CR<TC4S> to 1, the counter is cleared by generating the INTTC4 interrupt request. After stopping the timer in the INTTC4 interrupt service routine, clear SYSCR2<SYSCK> to 0 to switch the system clock from the low-frequency to high-frequency, and then SYSCR2<XTEN> to 0 to stop the low-frequency clock. Table 9-9 Setting Time in High-Frequency Warm-Up Counter Mode Minimum time Setting (TTREG4, 3 = 0100H) Maximum time Setting (TTREG4, 3 = FF00H) 16 µs 4.08 ms Example :After checking high-frequency clock oscillation stability with TC4 and 3, switching to the NORMAL1 mode SET (SYSCR2).7 : SYSCR2<XEN> ← 1 LD (TC3CR), 63H : Sets TFF3=0, source clock fc, and 16-bit mode. LD (TC4CR), 05H : Sets TFF4=0, and warm-up counter mode. LD (TTREG3), 0F800H : Sets the warm-up time. (The warm-up time depends on the oscillator characteristic.) : IMF ← 0 DI SET (EIRH). 4 : IMF ← 1 EI SET : PINTTC4: : Enables the INTTC4. (TC4CR).3 : Starts the TC4 and 3. : CLR (TC4CR).3 : Stops the TC4 and 3. CLR (SYSCR2).5 : SYSCR2<SYSCK> ← 0 (Switches the system clock to the high-frequency clock.) CLR (SYSCR2).6 : SYSCR2<XTEN> ← 0 (Stops the low-frequency clock.) RETI VINTTC4: : : DW PINTTC4 : INTTC4 vector table Page 106 TMP86CM23AUG 10. 8-Bit TimerCounter (TC5, TC6) 10.1 Configuration PWM mode Overflow fc/211 or fs/23 7 fc/2 5 fc/2 fc/23 fs fc/2 fc TC6 pin A B C D E F G H Y A B INTTC6 interrupt request Clear Y 8-bit up-counter TC6S S PDO, PPG mode A B S 16-bit mode S TC6M TC6S TFF6 Toggle Q Set Clear Y 16-bit mode Timer, Event Counter mode S TC6CK PDO6/PWM6/ PPG6 pin Timer F/F6 A Y B TC6CR TTREG6 PWM, PPG mode PWREG6 DecodeEN PDO, PWM, PPG mode TFF6 16-bit mode TC5S PWM mode fc/211 or fs/23 fc/27 5 fc/2 3 fc/2 fs fc/2 fc TC5 pin Y 8-bit up-counter Overflow 16-bit mode PDO mode 16-bit mode Timer, Event Couter mode S TC5M TC5S TFF5 INTTC5 interrupt request Clear A B C D E F G H Toggle Q Set Clear PDO5/PWM5/ pin Timer F/F5 TC5CK TC5CR PWM mode TTREG5 DecodeEN PWREG5 TFF5 Figure 10-1 8-Bit TimerCounter 5, 6 Page 107 PDO, PWM mode 16-bit mode 10. 8-Bit TimerCounter (TC5, TC6) 10.1 Configuration TMP86CM23AUG 10.2 TimerCounter Control The TimerCounter 5 is controlled by the TimerCounter 5 control register (TC5CR) and two 8-bit timer registers (TTREG5, PWREG5). TimerCounter 5 Timer Register TTREG5 (001EH) R/W 7 PWREG5 (002AH) R/W 7 6 5 4 3 2 1 0 (Initial value: 1111 1111) 6 5 4 3 2 1 0 (Initial value: 1111 1111) Note 1: Do not change the timer register (TTREG5) setting while the timer is running. Note 2: Do not change the timer register (PWREG5) setting in the operating mode except the 8-bit and 16-bit PWM modes while the timer is running. TimerCounter 5 Control Register TC5CR (001AH) TFF5 7 TFF5 6 5 4 TC5CK Time F/F5 control 3 2 TC5S 0: 1: 1 0 TC5M (Initial value: 0000 0000) Clear Set R/W NORMAL1/2, IDLE1/2 mode TC5CK Operating clock selection [Hz] DV7CK = 0 DV7CK = 1 SLOW1/2 SLEEP1/2 mode 000 fc/211 fs/23 fs/23 001 fc/27 fc/27 – 010 fc/25 fc/25 – 011 fc/23 fc/23 – 100 fs fs fs 101 fc/2 fc/2 – 110 fc fc fc (Note 8) 111 TC5S TC5 start control 0: 1: 000: 001: TC5M TC5M operating mode select 010: 011: 1**: R/W TC5 pin input Operation stop and counter clear Operation start R/W 8-bit timer/event counter mode 8-bit programmable divider output (PDO) mode 8-bit pulse width modulation (PWM) output mode 16-bit mode (Each mode is selectable with TC6M.) Reserved R/W Note 1: fc: High-frequency clock [Hz] fs: Low-frequency clock[Hz] Note 2: Do not change the TC5M, TC5CK and TFF5 settings while the timer is running. Note 3: To stop the timer operation (TC5S= 1 → 0), do not change the TC5M, TC5CK and TFF5 settings. To start the timer operation (TC5S= 0 → 1), TC5M, TC5CK and TFF5 can be programmed. Note 4: To use the TimerCounter in the 16-bit mode, set the operating mode by programming TC6CR<TC6M>, where TC5M must be fixed to 011. Note 5: To use the TimerCounter in the 16-bit mode, select the source clock by programming TC5CK. Set the timer start control and timer F/F control by programming TC6CR<TC6S> and TC6CR<TFF6>, respectively. Note 6: The operating clock settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 10-1 and Table 10-2. Page 108 TMP86CM23AUG Note 7: The timer register settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 103. Note 8: The operating clock fc in the SLOW or SLEEP mode can be used only as the high-frequency warm-up mode. Page 109 10. 8-Bit TimerCounter (TC5, TC6) 10.1 Configuration TMP86CM23AUG The TimerCounter 6 is controlled by the TimerCounter 6 control register (TC6CR) and two 8-bit timer registers (TTREG6 and PWREG6). TimerCounter 6 Timer Register TTREG6 (001FH) R/W 7 PWREG6 (002BH) R/W 7 6 5 4 3 2 1 0 (Initial value: 1111 1111) 6 5 4 3 2 1 0 (Initial value: 1111 1111) Note 1: Do not change the timer register (TTREG6) setting while the timer is running. Note 2: Do not change the timer register (PWREG6) setting in the operating mode except the 8-bit and 16-bit PWM modes while the timer is running. TimerCounter 6 Control Register TC6CR (001BH) TFF6 7 TFF6 6 5 4 TC6CK Timer F/F6 control 3 2 TC6S 0: 1: 1 0 TC6M (Initial value: 0000 0000) Clear Set R/W NORMAL1/2, IDLE1/2 mode TC6CK Operating clock selection [Hz] DV7CK = 0 DV7CK = 1 SLOW1/2 SLEEP1/2 mode 000 fc/211 fs/23 fs/23 001 fc/27 fc/27 – 010 fc/25 fc/25 – 011 fc/2 3 3 – 100 fs fs fs 101 fc/2 fc/2 – 110 fc fc – 111 TC6S TC6 start control 0: 1: 000: 001: 010: TC6M TC6M operating mode select 011: 100: 101: 110: 111: fc/2 R/W TC6 pin input Operation stop and counter clear Operation start R/W 8-bit timer/event counter mode 8-bit programmable divider output (PDO) mode 8-bit pulse width modulation (PWM) output mode Reserved 16-bit timer/event counter mode Warm-up counter mode 16-bit pulse width modulation (PWM) output mode 16-bit PPG mode R/W Note 1: fc: High-frequency clock [Hz] fs: Low-frequency clock [Hz] Note 2: Do not change the TC6M, TC6CK and TFF6 settings while the timer is running. Note 3: To stop the timer operation (TC6S= 1 → 0), do not change the TC6M, TC6CK and TFF6 settings. To start the timer operation (TC6S= 0 → 1), TC6M, TC6CK and TFF6 can be programmed. Note 4: When TC6M= 1** (upper byte in the 16-bit mode), the source clock becomes the TC5 overflow signal regardless of the TC6CK setting. Note 5: To use the TimerCounter in the 16-bit mode, select the operating mode by programming TC6M, where TC5CR<TC5M> must be set to 011. Page 110 TMP86CM23AUG Note 6: To the TimerCounter in the 16-bit mode, select the source clock by programming TC5CR<TC5CK>. Set the timer start control and timer F/F control by programming TC6S and TFF6, respectively. Note 7: The operating clock settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 10-1 and Table 10-2. Note 8: The timer register settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 103. Note 9: To use the PDO, PWM or PPG mode, a pulse is not output from the timer output pin when TC1CR2<TC6OUT> is set to 1. To output a pulse from the timer output pin, clear TC1CR2<TC6OUT> to 0. Table 10-1 Operating Mode and Selectable Source Clock (NORMAL1/2 and IDLE1/2 Modes) Operating mode fc/211 or fs/2 fc/27 fc/25 fc/23 fs fc/2 fc TC5 pin input TC6 pin input 3 8-bit timer Ο Ο Ο Ο – – – – – 8-bit event counter – – – – – – – Ο Ο 8-bit PDO Ο Ο Ο Ο – – – – – 8-bit PWM Ο Ο Ο Ο Ο Ο Ο – – 16-bit timer Ο Ο Ο Ο – – – – – 16-bit event counter – – – – – – – Ο – Warm-up counter – – – – Ο – – – – 16-bit PWM Ο Ο Ο Ο Ο Ο Ο Ο – 16-bit PPG Ο Ο Ο Ο – – – Ο – Note 1: For 16-bit operations (16-bit timer/event counter, warm-up counter, 16-bit PWM and 16-bit PPG), set its source clock on lower bit (TC5CK). Note 2: Ο : Available source clock Table 10-2 Operating Mode and Selectable Source Clock (SLOW1/2 and SLEEP1/2 Modes) Operating mode fc/211 or fc/27 fc/25 fc/23 fs fc/2 fc TC5 pin input TC6 pin input fs/23 8-bit timer Ο – – – – – – – – 8-bit event counter – – – – – – – Ο Ο 8-bit PDO Ο – – – – – – – – 8-bit PWM Ο – – – Ο – – – – 16-bit timer Ο – – – – – – – – 16-bit event counter – – – – – – – Ο – Warm-up counter – – – – – – Ο – – 16-bit PWM Ο – – – Ο – – Ο – 16-bit PPG Ο – – – – – – Ο – Note1: For 16-bit operations (16-bit timer/event counter, warm-up counter, 16-bit PWM and 16-bit PPG), set its source clock on lower bit (TC5CK). Note2: Ο : Available source clock Page 111 10. 8-Bit TimerCounter (TC5, TC6) 10.1 Configuration TMP86CM23AUG Table 10-3 Constraints on Register Values Being Compared Operating mode Register Value 8-bit timer/event counter 1≤ (TTREGn) ≤255 8-bit PDO 1≤ (TTREGn) ≤255 8-bit PWM 2≤ (PWREGn) ≤254 16-bit timer/event counter 1≤ (TTREG6, 5) ≤65535 Warm-up counter 256≤ (TTREG6, 5) ≤65535 16-bit PWM 2≤ (PWREG6, 5) ≤65534 16-bit PPG and (PWREG6, 5) + 1 < (TTREG6, 5) 1≤ (PWREG6, 5) < (TTREG6, 5) ≤65535 Note: n = 5 to 6 Page 112 TMP86CM23AUG 10.3 Function The TimerCounter 5 and 6 have the 8-bit timer, 8-bit event counter, 8-bit programmable divider output (PDO), 8bit pulse width modulation (PWM) output modes. The TimerCounter 5 and 6 (TC5, 6) are cascadable to form a 16bit timer. The 16-bit timer has the operating modes such as the 16-bit timer, 16-bit event counter, warm-up counter, 16-bit pulse width modulation (PWM) output and 16-bit programmable pulse generation (PPG) modes. 10.3.1 8-Bit Timer Mode (TC5 and 6) In the timer mode, the up-counter counts up using the internal clock. When a match between the up-counter and the timer register j (TTREGj) value is detected, an INTTCj interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting. Note 1: In the timer mode, fix TCjCR<TFFj> to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the timer mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the timer mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 5, 6 Table 10-4 Source Clock for TimerCounter 5, 6 (Internal Clock) Source Clock NORMAL1/2, IDLE1/2 mode Resolution Maximum Time Setting DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 mode fc/211 [Hz] fs/23 [Hz] fs/23 [Hz] 128 µs 244.14 µs 32.6 ms 62.3 ms fc/27 fc/27 – 8 µs – 2.0 ms – fc/25 fc/25 – 2 µs – 510 µs – fc/23 fc/23 – 500 ns – 127.5 µs – fc = 16 MHz fs = 32.768 kHz fc = 16 MHz fs = 32.768 kHz Example :Setting the timer mode with source clock fc/27 Hz and generating an interrupt 80 µs later (TimerCounter6, fc = 16.0 MHz) (TTREG6), 0AH : Sets the timer register (80 µs÷27/fc = 0AH). (EIRH). 5 : Enables INTTC6 interrupt. LD (TC6CR), 00010000B : Sets the operating clock to fc/27, and 8-bit timer mode. LD (TC6CR), 00011000B : Starts TC6. LD DI SET EI Page 113 10. 8-Bit TimerCounter (TC5, TC6) 10.1 Configuration TMP86CM23AUG TC6CR<TC6S> Internal Source Clock 1 Counter TTREG6 ? 2 3 n-1 n 0 1 2 n-1 n 0 1 2 0 n Match detect Counter clear INTTC6 interrupt request Counter clear Match detect Figure 10-2 8-Bit Timer Mode Timing Chart (TC6) 10.3.2 8-Bit Event Counter Mode (TC5, 6) In the 8-bit event counter mode, the up-counter counts up at the falling edge of the input pulse to the TCj pin. When a match between the up-counter and the TTREGj value is detected, an INTTCj interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting at the falling edge of the input pulse to the TCj pin. Two machine cycles are required for the low- or high-level pulse input to the TCj pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/24 Hz in the SLOW1/2 or SLEEP1/2 mode. Note 1: In the event counter mode, fix TCjCR<TFFj> to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the event counter mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the event counter mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 5, 6 TC6CR<TC6S> TC6 pin input 0 Counter TTREG6 ? 1 2 n-1 n 0 1 2 n-1 n 0 1 2 0 n Match detect INTTC6 interrupt request Counter clear Match detect Counter clear Figure 10-3 8-Bit Event Counter Mode Timing Chart (TC6) 10.3.3 8-Bit Programmable Divider Output (PDO) Mode (TC5, 6) This mode is used to generate a pulse with a 50% duty cycle from the PDOj pin. In the PDO mode, the up-counter counts up using the internal clock. When a match between the up-counter and the TTREGj value is detected, the logic level output from the PDOj pin is switched to the opposite state and the up-counter is cleared. The INTTCj interrupt request is generated at the time. The logic state opposite to the timer F/Fj logic level is output from the PDOj pin. An arbitrary value can be set to the timer F/Fj by TCjCR<TFFj>. Upon reset, the timer F/Fj value is initialized to 0. To use the programmable divider output, set the output latch of the I/O port to 1. Page 114 TMP86CM23AUG Example :Generating 1024 Hz pulse using TC6 (fc = 16.0 MHz) Setting port LD (TTREG6), 3DH : 1/1024÷27/fc÷2 = 3DH LD (TC6CR), 00010001B : Sets the operating clock to fc/27, and 8-bit PDO mode. LD (TC6CR), 00011001B : Starts TC6. Note 1: In the programmable divider output mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the programmable divider output mode, the new value programmed in TTREGj is in effect immediately after programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 2: When the timer is stopped during PDO output, the PDOj pin holds the output status when the timer is stopped. To change the output status, program TCjCR<TFFj> after the timer is stopped. Do not change the TCjCR<TFFj> setting upon stopping of the timer. Example: Fixing the PDOj pin to the high level when the TimerCounter is stopped CLR (TCjCR).3: Stops the timer. CLR (TCjCR).7: Sets the PDOj pin to the high level. Note 3: j = 5, 6 Page 115 Page 116 ? INTTC6 interrupt request PDO6 pin Timer F/F6 TTREG6 Counter Internal source clock TC6CR<TFF6> TC6CR<TC6S> 0 n 1 Match detect 2 n 0 1 Match detect 2 n 0 1 Match detect 2 n 0 1 Match detect 2 n 0 1 2 3 Set F/F Held at the level when the timer is stopped 0 Write of "1" 10.1 Configuration 10. 8-Bit TimerCounter (TC5, TC6) TMP86CM23AUG Figure 10-4 8-Bit PDO Mode Timing Chart (TC6) TMP86CM23AUG 10.3.4 8-Bit Pulse Width Modulation (PWM) Output Mode (TC5, 6) This mode is used to generate a pulse-width modulated (PWM) signals with up to 8 bits of resolution. The up-counter counts up using the internal clock. When a match between the up-counter and the PWREGj value is detected, the logic level output from the timer F/Fj is switched to the opposite state. The counter continues counting. The logic level output from the timer F/Fj is switched to the opposite state again by the up-counter overflow, and the counter is cleared. The INTTCj interrupt request is generated at this time. Since the initial value can be set to the timer F/Fj by TCjCR<TFFj>, positive and negative pulses can be generated. Upon reset, the timer F/Fj is cleared to 0. (The logic level output from the PWMj pin is the opposite to the timer F/Fj logic level.) Since PWREGj in the PWM mode is serially connected to the shift register, the value set to PWREGj can be changed while the timer is running. The value set to PWREGj during a run of the timer is shifted by the INTTCj interrupt request and loaded into PWREGj. While the timer is stopped, the value is shifted immediately after the programming of PWREGj. If executing the read instruction to PWREGj during PWM output, the value in the shift register is read, but not the value set in PWREGj. Therefore, after writing to PWREGj, the reading data of PWREGj is previous value until INTTCj is generated. For the pin used for PWM output, the output latch of the I/O port must be set to 1. Note 1: In the PWM mode, program the timer register PWREGj immediately after the INTTCj interrupt request is generated (normally in the INTTCj interrupt service routine.) If the programming of PWREGj and the interrupt request occur at the same time, an unstable value is shifted, that may result in generation of the pulse different from the programmed value until the next INTTCj interrupt request is generated. Note 2: When the timer is stopped during PWM output, the PWMj pin holds the output status when the timer is stopped. To change the output status, program TCjCR<TFFj> after the timer is stopped. Do not change the TCjCR<TFFj> upon stopping of the timer. Example: Fixing the PWMj pin to the high level when the TimerCounter is stopped CLR (TCjCR).3: Stops the timer. CLR (TCjCR).7: Sets the PWMj pin to the high level. Note 3: To enter the STOP mode during PWM output, stop the timer and then enter the STOP mode. If the STOP mode is entered without stopping the timer when fc, fc/2 or fs is selected as the source clock, a pulse is output from the PWMj pin during the warm-up period time after exiting the STOP mode. Note 4: j = 5, 6 Table 10-5 PWM Output Mode Source Clock NORMAL1/2, IDLE1/2 mode Resolution Repeated Cycle DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 mode fc/211 [Hz] fs/23 [Hz] fs/23 [Hz] 128 µs 244.14 µs 32.8 ms 62.5 ms fc/2 7 – 8 µs – 2.05 ms – fc/2 5 – 2 µs – 512 µs – fc/2 7 fc/2 5 fc = 16 MHz fs = 32.768 kHz fc = 16 MHz fs = 32.768 kHz fc/23 fc/23 – 500 ns – 128 µs – fs fs fs 30.5 µs 30.5 µs 7.81 ms 7.81 ms fc/2 fc/2 – 125 ns – 32 µs – fc fc – 62.5 ns – 16 µs – Page 117 Page 118 ? Shift registar 0 Shift INTTC6 interrupt request PWM6 pin Timer F/F6 ? PWREG6 Counter Internal source clock TC6CR<TFF6> TC6CR<TC6S> n n n Match detect 1 n n+1 Shift FF 0 n n n+1 m One cycle period Write to PWREG6 Match detect 1 Shift FF 0 m m m+1 Write to PWREG6 p Match detect m 1 Shift FF 0 p p Match detect 1 p 10.1 Configuration 10. 8-Bit TimerCounter (TC5, TC6) TMP86CM23AUG Figure 10-5 8-Bit PWM Mode Timing Chart (TC6) TMP86CM23AUG 10.3.5 16-Bit Timer Mode (TC5 and 6) In the timer mode, the up-counter counts up using the internal clock. The TimerCounter 5 and 6 are cascadable to form a 16-bit timer. When a match between the up-counter and the timer register (TTREG5, TTREG6) value is detected after the timer is started by setting TC6CR<TC6S> to 1, an INTTC6 interrupt is generated and the up-counter is cleared. After being cleared, the up-counter continues counting. Program the lower byte and upper byte in this order in the timer register. (Programming only the upper or lower byte should not be attempted.) Note 1: In the timer mode, fix TCjCR<TFFj> to 0. If not fixed, the PDOj, PWMj, and PPGj pins may output a pulse. Note 2: In the timer mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the timer mode, the new value programmed in TTREGj is in effect immediately after programming of TTREGj. Therefore, if TTREGj is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 5, 6 Table 10-6 Source Clock for 16-Bit Timer Mode Source Clock Resolution NORMAL1/2, IDLE1/2 mode Maximum Time Setting DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 mode fc/211 fs/23 fs/23 128 µs 244.14 µs 8.39 s 16 s fc/27 fc/27 – 8 µs – 524.3 ms – fc/25 fc/25 – 2 µs – 131.1 ms – fc/23 fc/23 – 500 ns – 32.8 ms – fc = 16 MHz fs = 32.768 kHz fc = 16 MHz fs = 32.768 kHz Example :Setting the timer mode with source clock fc/27 Hz, and generating an interrupt 300 ms later (fc = 16.0 MHz) (TTREG5), 927CH : Sets the timer register (300 ms÷27/fc = 927CH). (EIRH). 5 : Enables INTTC6 interrupt. LD (TC5CR), 13H :Sets the operating clock to fc/27, and 16-bit timer mode (lower byte). LD (TC6CR), 04H : Sets the 16-bit timer mode (upper byte). LD (TC6CR), 0CH : Starts the timer. LDW DI SET EI TC6CR<TC6S> Internal source clock 0 Counter TTREG5 (Lower byte) TTREG6 (Upper byte) ? ? INTTC6 interrupt request 1 2 3 mn-1 mn 0 1 2 mn-1 mn 0 1 n m Match detect Counter clear Match detect Counter clear Figure 10-6 16-Bit Timer Mode Timing Chart (TC5 and TC6) Page 119 2 0 10. 8-Bit TimerCounter (TC5, TC6) 10.1 Configuration TMP86CM23AUG 10.3.6 16-Bit Event Counter Mode (TC5 and 6) In the event counter mode, the up-counter counts up at the falling edge to the TC5 pin. The TimerCounter 5 and 6 are cascadable to form a 16-bit event counter. When a match between the up-counter and the timer register (TTREG5, TTREG6) value is detected after the timer is started by setting TC6CR<TC6S> to 1, an INTTC6 interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting at the falling edge of the input pulse to the TC5 pin. Two machine cycles are required for the low- or high-level pulse input to the TC5 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/ 2 in the SLOW1/2 or SLEEP1/2 mode. Program the lower byte (TTREG5), and upper byte (TTREG6) in this order in the timer register. (Programming only the upper or lower byte should not be attempted.) 4 Note 1: In the event counter mode, fix TCjCR<TFFj> to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the event counter mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the event counter mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGj is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 5, 6 10.3.7 16-Bit Pulse Width Modulation (PWM) Output Mode (TC5 and 6) This mode is used to generate a pulse-width modulated (PWM) signals with up to 16 bits of resolution. The TimerCounter 5 and 6 are cascadable to form the 16-bit PWM signal generator. The counter counts up using the internal clock or external clock. When a match between the up-counter and the timer register (PWREG5, PWREG6) value is detected, the logic level output from the timer F/F6 is switched to the opposite state. The counter continues counting. The logic level output from the timer F/F6 is switched to the opposite state again by the counter overflow, and the counter is cleared. The INTTC6 interrupt is generated at this time. Two machine cycles are required for the high- or low-level pulse input to the TC5 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/24 to in the SLOW1/2 or SLEEP1/2 mode. Since the initial value can be set to the timer F/F6 by TC6CR<TFF6>, positive and negative pulses can be generated. Upon reset, the timer F/F6 is cleared to 0. (The logic level output from the PWM6 pin is the opposite to the timer F/F6 logic level.) Since PWREG6 and 5 in the PWM mode are serially connected to the shift register, the values set to PWREG6 and 5 can be changed while the timer is running. The values set to PWREG6 and 5 during a run of the timer are shifted by the INTTCj interrupt request and loaded into PWREG6 and 5. While the timer is stopped, the values are shifted immediately after the programming of PWREG6 and 5. Set the lower byte (PWREG5) and upper byte (PWREG6) in this order to program PWREG6 and 5. (Programming only the lower or upper byte of the register should not be attempted.) If executing the read instruction to PWREG6 and 5 during PWM output, the values set in the shift register is read, but not the values set in PWREG6 and 5. Therefore, after writing to the PWREG6 and 5, reading data of PWREG6 and 5 is previous value until INTTC6 is generated. For the pin used for PWM output, the output latch of the I/O port must be set to 1. Note 1: In the PWM mode, program the timer register PWREG6 and 5 immediately after the INTTC6 interrupt request is generated (normally in the INTTC6 interrupt service routine.) If the programming of PWREGj and the interrupt request occur at the same time, an unstable value is shifted, that may result in generation of pulse different from the programmed value until the next INTTC6 interrupt request is generated. Note 2: When the timer is stopped during PWM output, the PWM6 pin holds the output status when the timer is stopped. To change the output status, program TC6CR<TFF6> after the timer is stopped. Do not program TC6CR<TFF6> upon stopping of the timer. Example: Fixing the PWM6 pin to the high level when the TimerCounter is stopped Page 120 TMP86CM23AUG CLR (TC6CR).3: Stops the timer. CLR (TC6CR).7 : Sets the PWM6 pin to the high level. Note 3: To enter the STOP mode, stop the timer and then enter the STOP mode. If the STOP mode is entered without stopping of the timer when fc, fc/2 or fs is selected as the source clock, a pulse is output from the PWM6 pin during the warm-up period time after exiting the STOP mode. Table 10-7 16-Bit PWM Output Mode Source Clock NORMAL1/2, IDLE1/2 mode Resolution Repeated Cycle DV7CK = 0 DV7CK = 1 SLOW1/2, SLEEP1/2 mode fc/211 fs/23 [Hz] fs/23 [Hz] 128 µs 244.14 µs 8.39 s 16 s fc/27 fc/27 – 8 µs – 524.3 ms – fc/25 fc/25 – 2 µs – 131.1 ms – fc/23 fc/23 – 500 ns – 32.8 ms – fc = 16 MHz fs = 32.768 kHz fc = 16 MHz fs = 32.768 kHz fs fs fs 30.5 µs 30.5 µs 2s 2s fc/2 fc/2 – 125 ns – 8.2 ms – fc fc – 62.5 ns – 4.1 ms – Example :Generating a pulse with 1-ms high-level width and a period of 32.768 ms (fc = 16.0 MHz) Setting ports LDW (PWREG5), 07D0H : Sets the pulse width. LD (TC5CR), 33H : Sets the operating clock to fc/23, and 16-bit PWM output mode (lower byte). LD (TC6CR), 056H : Sets TFF6 to the initial value 0, and 16-bit PWM signal generation mode (upper byte). LD (TC6CR), 05EH : Starts the timer. Page 121 Page 122 ? ? PWREG6 (Upper byte) 16-bit shift register 0 a Shift INTTC6 interrupt request PWM6 pin Timer F/F6 ? PWREG5 (Lower byte) Counter Internal source clock TC6CR<TFF6> TC6CR<TC6S> an n an Match detect 1 an an+1 Shift FFFF 0 an an an+1 m b One cycle period Write to PWREG6 Write to PWREG5 Match detect 1 Shift FFFF 0 bm bm bm+1 p c Write to PWREG6 Write to PWREG5 Match detect bm 1 Shift FFFF 0 cp Match detect cp 1 cp 10.1 Configuration 10. 8-Bit TimerCounter (TC5, TC6) TMP86CM23AUG Figure 10-7 16-Bit PWM Mode Timing Chart (TC5 and TC6) TMP86CM23AUG 10.3.8 16-Bit Programmable Pulse Generate (PPG) Output Mode (TC5 and 6) This mode is used to generate pulses with up to 16-bits of resolution. The timer counter 5 and 6 are cascadable to enter the 16-bit PPG mode. The counter counts up using the internal clock or external clock. When a match between the up-counter and the timer register (PWREG5, PWREG6) value is detected, the logic level output from the timer F/F6 is switched to the opposite state. The counter continues counting. The logic level output from the timer F/F6 is switched to the opposite state again when a match between the up-counter and the timer register (TTREG5, TTREG6) value is detected, and the counter is cleared. The INTTC6 interrupt is generated at this time. Two machine cycles are required for the high- or low-level pulse input to the TC5 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/24 to in the SLOW1/ 2 or SLEEP1/2 mode. Since the initial value can be set to the timer F/F6 by TC6CR<TFF6>, positive and negative pulses can be generated. Upon reset, the timer F/F6 is cleared to 0. (The logic level output from the PPG6 pin is the opposite to the timer F/F6.) Set the lower byte and upper byte in this order to program the timer register. (TTREG5 → TTREG6, PWREG5 → PWREG6) (Programming only the upper or lower byte should not be attempted.) For PPG output, set the output latch of the I/O port to 1. Example :Generating a pulse with 1-ms high-level width and a period of 16.385 ms (fc = 16.0 MHz) Setting ports LDW (PWREG5), 07D0H : Sets the pulse width. LDW (TTREG5), 8002H : Sets the cycle period. LD (TC5CR), 33H : Sets the operating clock to fc/23, and16-bit PPG mode (lower byte). LD (TC6CR), 057H : Sets TFF6 to the initial value 0, and 16-bit PPG mode (upper byte). LD (TC6CR), 05FH : Starts the timer. Note 1: In the PPG mode, do not change the PWREGi and TTREGi settings while the timer is running. Since PWREGi and TTREGi are not in the shift register configuration in the PPG mode, the new values programmed in PWREGi and TTREGi are in effect immediately after programming PWREGi and TTREGi. Therefore, if PWREGi and TTREGi are changed while the timer is running, an expected operation may not be obtained. Note 2: When the timer is stopped during PPG output, the PPG6 pin holds the output status when the timer is stopped. To change the output status, program TC6CR<TFF6> after the timer is stopped. Do not change TC6CR<TFF6> upon stopping of the timer. Example: Fixing the PPG6 pin to the high level when the TimerCounter is stopped CLR (TC6CR).3: Stops the timer CLR (TC6CR).7: Sets the PPG6 pin to the high level Note 3: i = 5, 6 Page 123 Page 124 ? TTREG6 (Upper byte) INTTC6 interrupt request PPG6 pin Timer F/F6 ? ? TTREG5 (Lower byte) PWREG6 (Upper byte) n PWREG5 (Lower byte) ? 0 Counter Internal source clock TC6CR<TFF6> TC6CR<TC6S> m r q mn Match detect 1 mn mn+1 Match detect qr-1 qr 0 mn Match detect 1 mn mn+1 Match detect qr-1 qr 0 mn Match detect 1 F/F clear 0 Held at the level when the timer stops mn mn+1 Write of "0" 10.1 Configuration 10. 8-Bit TimerCounter (TC5, TC6) TMP86CM23AUG Figure 10-8 16-Bit PPG Mode Timing Chart (TC5 and TC6) TMP86CM23AUG 10.3.9 Warm-Up Counter Mode In this mode, the warm-up period time is obtained to assure oscillation stability when the system clocking is switched between the high-frequency and low-frequency. The timer counter 5 and 6 are cascadable to form a 16-bit TimerCounter. The warm-up counter mode has two types of mode; switching from the high-frequency to low-frequency, and vice-versa. Note 1: In the warm-up counter mode, fix TCiCR<TFFi> to 0. If not fixed, the PDOi, PWMi and PPGi pins may output pulses. Note 2: In the warm-up counter mode, only upper 8 bits of the timer register TTREG6 and 5 are used for match detection and lower 8 bits are not used. Note 3: i = 5, 6 10.3.9.1 Low-Frequency Warm-up Counter Mode (NORMAL1 → NORMAL2 → SLOW2 → SLOW1) In this mode, the warm-up period time from a stop of the low-frequency clock fs to oscillation stability is obtained. Before starting the timer, set SYSCR2<XTEN> to 1 to oscillate the low-frequency clock. When a match between the up-counter and the timer register (TTREG6, 5) value is detected after the timer is started by setting TC6CR<TC6S> to 1, the counter is cleared by generating the INTTC6 interrupt request. After stopping the timer in the INTTC6 interrupt service routine, set SYSCR2<SYSCK> to 1 to switch the system clock from the high-frequency to low-frequency, and then clear of SYSCR2<XEN> to 0 to stop the high-frequency clock. Table 10-8 Setting Time of Low-Frequency Warm-Up Counter Mode (fs = 32.768 kHz) Minimum Time Setting (TTREG6, 5 = 0100H) Maximum Time Setting (TTREG6, 5 = FF00H) 7.81 ms 1.99 s Example :After checking low-frequency clock oscillation stability with TC6 and 5, switching to the SLOW1 mode SET (SYSCR2).6 : SYSCR2<XTEN> ← 1 LD (TC5CR), 43H : Sets TFF5=0, source clock fs, and 16-bit mode. LD (TC6CR), 05H : Sets TFF6=0, and warm-up counter mode. LD (TTREG5), 8000H : Sets the warm-up time. (The warm-up time depends on the oscillator characteristic.) : IMF ← 0 DI SET (EIRH). 5 : IMF ← 1 EI SET : PINTTC6: : Enables the INTTC6. (TC6CR).3 : Starts TC6 and 5. : CLR (TC6CR).3 : Stops TC6 and 5. SET (SYSCR2).5 : SYSCR2<SYSCK> ← 1 (Switches the system clock to the low-frequency clock.) CLR (SYSCR2).7 : SYSCR2<XEN> ← 0 (Stops the high-frequency clock.) RETI : VINTTC6: DW : PINTTC6 : INTTC6 vector table Page 125 10. 8-Bit TimerCounter (TC5, TC6) 10.1 Configuration TMP86CM23AUG 10.3.9.2 High-Frequency Warm-Up Counter Mode (SLOW1 → SLOW2 → NORMAL2 → NORMAL1) In this mode, the warm-up period time from a stop of the high-frequency clock fc to the oscillation stability is obtained. Before starting the timer, set SYSCR2<XEN> to 1 to oscillate the high-frequency clock. When a match between the up-counter and the timer register (TTREG6, 5) value is detected after the timer is started by setting TC6CR<TC6S> to 1, the counter is cleared by generating the INTTC6 interrupt request. After stopping the timer in the INTTC6 interrupt service routine, clear SYSCR2<SYSCK> to 0 to switch the system clock from the low-frequency to high-frequency, and then SYSCR2<XTEN> to 0 to stop the low-frequency clock. Table 10-9 Setting Time in High-Frequency Warm-Up Counter Mode Minimum time Setting (TTREG6, 5 = 0100H) Maximum time Setting (TTREG6, 5 = FF00H) 16 µs 4.08 ms Example :After checking high-frequency clock oscillation stability with TC6 and 5, switching to the NORMAL1 mode SET (SYSCR2).7 : SYSCR2<XEN> ← 1 LD (TC5CR), 63H : Sets TFF5=0, source clock fc, and 16-bit mode. LD (TC6CR), 05H : Sets TFF6=0, and warm-up counter mode. LD (TTREG5), 0F800H : Sets the warm-up time. (The warm-up time depends on the oscillator characteristic.) : IMF ← 0 DI SET (EIRH). 5 : IMF ← 1 EI SET : PINTTC6: : Enables the INTTC6. (TC6CR).3 : Starts the TC6 and 5. : CLR (TC6CR).3 : Stops the TC6 and 5. CLR (SYSCR2).5 : SYSCR2<SYSCK> ← 0 (Switches the system clock to the high-frequency clock.) CLR (SYSCR2).6 : SYSCR2<XTEN> ← 0 (Stops the low-frequency clock.) RETI VINTTC6: : : DW PINTTC6 : INTTC6 vector table Page 126 TMP86CM23AUG 11. Asynchronous Serial interface (UART ) 11.1 Configuration UART control register 1 Transmit data buffer UARTCR1 TDBUF 3 Receive data buffer RDBUF 2 INTTX Receive control circuit Transmit control circuit 2 Shift register Shift register Parity bit Stop bit Noise rejection circuit RXD TXD INTRXD Transmit/receive clock Y M P X S fc/13 fc/26 fc/52 fc/104 fc/208 fc/416 INTTC5 fc/96 A B C D E F G H A B C 6 fc/2 fc/27 8 fc/2 S 2 Y 4 2 Counter UARTSR UARTCR2 UART status register UART control register 2 MPX: Multiplexer Baud rate generator Figure 11-1 UART (Asynchronous Serial Interface) Page 127 11. Asynchronous Serial interface (UART ) 11.2 Control TMP86CM23AUG 11.2 Control UART is controlled by the UART Control Registers (UARTCR1, UARTCR2). The operating status can be monitored using the UART status register (UARTSR). UART Control Register1 UARTCR1 (0025H) 7 6 5 4 3 TXE RXE STBT EVEN PE 2 1 0 BRG (Initial value: 0000 0000) TXE Transfer operation 0: 1: Disable Enable RXE Receive operation 0: 1: Disable Enable STBT Transmit stop bit length 0: 1: 1 bit 2 bits EVEN Even-numbered parity 0: 1: Odd-numbered parity Even-numbered parity Parity addition 0: 1: No parity Parity PE BRG 000: 001: 010: 011: 100: 101: 110: 111: Transmit clock select Write only fc/13 [Hz] fc/26 fc/52 fc/104 fc/208 fc/416 TC5 ( Input INTTC5) fc/96 Note 1: When operations are disabled by setting TXE and RXE bit to “0”, the setting becomes valid when data transmit or receive complete. When the transmit data is stored in the transmit data buffer, the data are not transmitted. Even if data transmit is enabled, until new data are written to the transmit data buffer, the current data are not transmitted. Note 2: The transmit clock and the parity are common to transmit and receive. Note 3: UARTCR1<RXE> and UARTCR1<TXE> should be set to “0” before UARTCR1<BRG> is changed. UART Control Register2 UARTCR2 (0026H) 7 6 5 4 3 2 1 0 RXDNC RXDNC STOPBR Selection of RXD input noise rejection time Receive stop bit length 00: 01: 10: 11: 0: 1: STOPBR (Initial value: **** *000) No noise rejection (Hysteresis input) Rejects pulses shorter than 31/fc [s] as noise Rejects pulses shorter than 63/fc [s] as noise Rejects pulses shorter than 127/fc [s] as noise Write only 1 bit 2 bits Note: When UARTCR2<RXDNC> = “01”, pulses longer than 96/fc [s] are always regarded as signals; when UARTCR2<RXDNC> = “10”, longer than 192/fc [s]; and when UARTCR2<RXDNC> = “11”, longer than 384/fc [s]. Page 128 TMP86CM23AUG UART Status Register UARTSR (0025H) 7 6 5 4 3 2 1 PERR FERR OERR RBFL TEND TBEP 0 (Initial value: 0000 11**) PERR Parity error flag 0: 1: No parity error Parity error FERR Framing error flag 0: 1: No framing error Framing error OERR Overrun error flag 0: 1: No overrun error Overrun error RBFL Receive data buffer full flag 0: 1: Receive data buffer empty Receive data buffer full TEND Transmit end flag 0: 1: On transmitting Transmit end TBEP Transmit data buffer empty flag 0: 1: Transmit data buffer full (Transmit data writing is finished) Transmit data buffer empty Note: When an INTTXD is generated, TBEP flag is set to "1" automatically. UART Receive Data Buffer RDBUF (0F9BH) 7 6 5 4 3 2 1 0 Read only (Initial value: 0000 0000) UART Transmit Data Buffer TDBUF (0F9BH) 7 6 5 4 3 2 1 0 Write only (Initial value: 0000 0000) Page 129 Read only 11. Asynchronous Serial interface (UART ) 11.3 Transfer Data Format TMP86CM23AUG 11.3 Transfer Data Format In UART, an one-bit start bit (Low level), stop bit (Bit length selectable at high level, by UARTCR1<STBT>), and parity (Select parity in UARTCR1<PE>; even- or odd-numbered parity by UARTCR1<EVEN>) are added to the transfer data. The transfer data formats are shown as follows. PE STBT 0 Frame Length 8 1 2 3 9 10 0 Start Bit 0 Bit 1 0 1 Start Bit 0 1 0 Start 1 1 Start 11 Bit 6 Bit 7 Stop 1 Bit 1 Bit 6 Bit 7 Stop 1 Stop 2 Bit 0 Bit 1 Bit 6 Bit 7 Parity Stop 1 Bit 0 Bit 1 Bit 6 Bit 7 Parity Stop 1 12 Stop 2 Figure 11-2 Transfer Data Format Without parity / 1 STOP bit With parity / 1 STOP bit Without parity / 2 STOP bit With parity / 2 STOP bit Figure 11-3 Caution on Changing Transfer Data Format Note: In order to switch the transfer data format, perform transmit operations in the above Figure 11-3 sequence except for the initial setting. Page 130 TMP86CM23AUG 11.4 Transfer Rate The baud rate of UART is set of UARTCR1<BRG>. The example of the baud rate are shown as follows. Table 11-1 Transfer Rate (Example) Source Clock BRG 16 MHz 8 MHz 4 MHz 000 76800 [baud] 38400 [baud] 19200 [baud] 001 38400 19200 9600 010 19200 9600 4800 011 9600 4800 2400 100 4800 2400 1200 101 2400 1200 600 When TC5 is used as the UART transfer rate (when UARTCR1<BRG> = “110”), the transfer clock and transfer rate are determined as follows: Transfer clock [Hz] = TC5 source clock [Hz] / TTREG5 setting value Transfer Rate [baud] = Transfer clock [Hz] / 16 11.5 Data Sampling Method The UART receiver keeps sampling input using the clock selected by UARTCR1<BRG> until a start bit is detected in RXD pin input. RT clock starts detecting “L” level of the RXD pin. Once a start bit is detected, the start bit, data bits, stop bit(s), and parity bit are sampled at three times of RT7, RT8, and RT9 during one receiver clock interval (RT clock). (RT0 is the position where the bit supposedly starts.) Bit is determined according to majority rule (The data are the same twice or more out of three samplings). RXD pin Start bit RT0 1 2 3 Bit 0 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 2 3 4 5 6 7 8 9 10 11 RT clock Start bit Internal receive data Bit 0 (a) Without noise rejection circuit RXD pin Start bit RT0 1 2 3 Bit 0 4 5 6 7 8 9 10 11 12 13 14 15 0 1 RT clock Internal receive data Start bit Bit 0 (b) With noise rejection circuit Figure 11-4 Data Sampling Method Page 131 11. Asynchronous Serial interface (UART ) 11.6 STOP Bit Length TMP86CM23AUG 11.6 STOP Bit Length Select a transmit stop bit length (1 bit or 2 bits) by UARTCR1<STBT>. 11.7 Parity Set parity / no parity by UARTCR1<PE> and set parity type (Odd- or Even-numbered) by UARTCR1<EVEN>. 11.8 Transmit/Receive Operation 11.8.1 Data Transmit Operation Set UARTCR1<TXE> to “1”. Read UARTSR to check UARTSR<TBEP> = “1”, then write data in TDBUF (Transmit data buffer). Writing data in TDBUF zero-clears UARTSR<TBEP>, transfers the data to the transmit shift register and the data are sequentially output from the TXD pin. The data output include a one-bit start bit, stop bits whose number is specified in UARTCR1<STBT> and a parity bit if parity addition is specified. Select the data transfer baud rate using UARTCR1<BRG>. When data transmit starts, transmit buffer empty flag UARTSR<TBEP> is set to “1” and an INTTX interrupt is generated. While UARTCR1<TXE> = “0” and from when “1” is written to UARTCR1<TXE> to when send data are written to TDBUF, the TXD pin is fixed at high level. When transmitting data, first read UARTSR, then write data in TDBUF. Otherwise, UARTSR<TBEP> is not zero-cleared and transmit does not start. 11.8.2 Data Receive Operation Set UARTCR1<RXE> to “1”. When data are received via the RXD pin, the receive data are transferred to RDBUF (Receive data buffer). At this time, the data transmitted includes a start bit and stop bit(s) and a parity bit if parity addition is specified. When stop bit(s) are received, data only are extracted and transferred to RDBUF (Receive data buffer). Then the receive buffer full flag UARTSR<RBFL> is set and an INTRXD interrupt is generated. Select the data transfer baud rate using UARTCR1<BRG>. If an overrun error (OERR) occurs when data are received, the data are not transferred to RDBUF (Receive data buffer) but discarded; data in the RDBUF are not affected. Note:When a receive operation is disabled by setting UARTCR1<RXE> bit to “0”, the setting becomes valid when data receive is completed. However, if a framing error occurs in data receive, the receive-disabling setting may not become valid. If a framing error occurs, be sure to perform a re-receive operation. Page 132 TMP86CM23AUG 11.9 Status Flag 11.9.1 Parity Error When parity determined using the receive data bits differs from the received parity bit, the parity error flag UARTSR<PERR> is set to “1”. The UARTSR<PERR> is cleared to “0” when the RDBUF is read after reading the UARTSR. RXD pin Shift register Parity Stop pxxxx0* xxxx0** 1pxxxx0 UARTSR<PERR> After reading UARTSR then RDBUF clears PERR. INTRXD interrupt Figure 11-5 Generation of Parity Error 11.9.2 Framing Error When “0” is sampled as the stop bit in the receive data, framing error flag UARTSR<FERR> is set to “1”. The UARTSR<FERR> is cleared to “0” when the RDBUF is read after reading the UARTSR. Shift register Stop Final bit RXD pin xxxx0* xxx0** 0xxxx0 After reading UARTSR then RDBUF clears FERR. UARTSR<FERR> INTRXD interrupt Figure 11-6 Generation of Framing Error 11.9.3 Overrun Error When all bits in the next data are received while unread data are still in RDBUF, overrun error flag UARTSR<OERR> is set to “1”. In this case, the receive data is discarded; data in RDBUF are not affected. The UARTSR<OERR> is cleared to “0” when the RDBUF is read after reading the UARTSR. Page 133 11. Asynchronous Serial interface (UART ) 11.9 Status Flag TMP86CM23AUG UARTSR<RBFL> RXD pin Stop Final bit Shift register xxx0** RDBUF yyyy xxxx0* 1xxxx0 UARTSR<OERR> After reading UARTSR then RDBUF clears OERR. INTRXD interrupt Figure 11-7 Generation of Overrun Error Note:Receive operations are disabled until the overrun error flag UARTSR<OERR> is cleared. 11.9.4 Receive Data Buffer Full Loading the received data in RDBUF sets receive data buffer full flag UARTSR<RBFL> to "1". The UARTSR<RBFL> is cleared to “0” when the RDBUF is read after reading the UARTSR. Stop Final bit RXD pin Shift register xxx0** RDBUF yyyy xxxx0* 1xxxx0 xxxx After reading UARTSR then RDBUF clears RBFL. UARTSR<RBFL> INTRXD interrupt Figure 11-8 Generation of Receive Data Buffer Full Note:If the overrun error flag UARTSR<OERR> is set during the period between reading the UARTSR and reading the RDBUF, it cannot be cleared by only reading the RDBUF. Therefore, after reading the RDBUF, read the UARTSR again to check whether or not the overrun error flag which should have been cleared still remains set. 11.9.5 Transmit Data Buffer Empty When no data is in the transmit buffer TDBUF, that is, when data in TDBUF are transferred to the transmit shift register and data transmit starts, transmit data buffer empty flag UARTSR<TBEP> is set to “1”. The UARTSR<TBEP> is cleared to “0” when the TDBUF is written after reading the UARTSR. Page 134 TMP86CM23AUG Data write xxxx TDBUF *****1 Shift register TXD pin Data write zzzz yyyy 1xxxx0 *1xxxx ****1x *****1 Start Bit 0 Final bit Stop 1yyyy0 UARTSR<TBEP> After reading UARTSR writing TDBUF clears TBEP. INTTX interrupt Figure 11-9 Generation of Transmit Data Buffer Empty 11.9.6 Transmit End Flag When data are transmitted and no data is in TDBUF (UARTSR<TBEP> = “1”), transmit end flag UARTSR<TEND> is set to “1”. The UARTSR<TEND> is cleared to “0” when the data transmit is started after writing the TDBUF. Shift register TXD pin ***1xx ****1x *****1 1yyyy0 Stop Start *1yyyy Bit 0 Data write for TDBUF UARTSR<TBEP> UARTSR<TEND> INTTX interrupt Figure 11-10 Generation of Transmit End Flag and Transmit Data Buffer Empty Page 135 11. Asynchronous Serial interface (UART ) 11.9 Status Flag TMP86CM23AUG Page 136 TMP86CM23AUG 12. Synchronous Serial Interface (SIO) The TMP86CM23AUG has a clocked-synchronous 8-bit serial interface. Serial interface has an 8-byte transmit and receive data buffer that can automatically and continuously transfer up to 64 bits of data. Serial interface is connected to outside peripherl devices via SO, SI, SCK port. 12.1 Configuration SIO control / status register SIOSR SIOCR1 SIOCR2 CPU Transmit and receive data buffer (8 bytes in DBR) Buffer control circuit Control circuit Shift register Shift clock 7 6 5 4 3 2 1 0 SO Serial data output 8-bit transfer 4-bit transfer SI Serial data input INTSIO interrupt request Serial clock SCK Serial clock I/O Figure 12-1 Serial Interface Page 137 12. Synchronous Serial Interface (SIO) 12.2 Control TMP86CM23AUG 12.2 Control The serial interface is controlled by SIO control registers (SIOCR1/SIOCR2). The serial interface status can be determined by reading SIO status register (SIOSR). The transmit and receive data buffer is controlled by the SIOCR2<BUF>. The data buffer is assigned to address 0F90H to 0F97H for SIO in the DBR area, and can continuously transfer up to 8 words (bytes or nibbles) at one time. When the specified number of words has been transferred, a buffer empty (in the transmit mode) or a buffer full (in the receive mode or transmit/receive mode) interrupt (INTSIO) is generated. When the internal clock is used as the serial clock in the 8-bit receive mode and the 8-bit transmit/receive mode, a fixed interval wait can be applied to the serial clock for each word transferred. Four different wait times can be selected with SIOCR2<WAIT>. SIO Control Register 1 SIOCR1 7 6 (0F98H) SIOS SIOINH SIOS 5 4 3 2 1 SIOM 0 SCK 0: Stop 1: Start (Initial value: 0000 0000) Indicate transfer start / stop SIOINH 0: Continuously transfer 1: Abort transfer (Automatically cleared after abort) 000: 8-bit transmit mode 010: 4-bit transmit mode 100: 8-bit transmit / receive mode 101: 8-bit receive mode 110: 4-bit receive mode Continue / abort transfer SIOM Write only Transfer mode select Except the above: Reserved NORMAL1/2, IDLE1/2 mode SCK Serial clock select DV7CK = 0 DV7CK = 1 SLOW1/2 SLEEP1/2 mode 000 fc/213 fs/25 fs/25 001 fc/28 fc/28 - 010 fc/27 fc/27 - 011 fc/26 fc/26 - 100 fc/25 fc/25 - 101 fc/24 fc/24 - 110 Reserved 111 External clock ( Input from SCK pin ) Note 1: fc; High-frequency clock [Hz], fs; Low-frequency clock [Hz] Note 2: Set SIOS to "0" and SIOINH to "1" when setting the transfer mode or serial clock. Note 3: SIOCR1 is write-only register, which cannot access any of in read-modify-write instruction such as bit operate, etc. SIO Control Register 2 SIOCR2 (0F99H) 7 6 5 4 3 WAIT Page 138 2 1 BUF 0 (Initial value: ***0 0000) Write only TMP86CM23AUG Always sets "00" except 8-bit transmit / receive mode. WAIT Wait control Number of transfer words (Buffer address in use) BUF 00: Tf = TD(Non wait) 01: Tf = 2TD(Wait) 10: Tf = 4TD(Wait) 11: Tf = 8TD (Wait) 000: 1 word transfer 0F90H 001: 2 words transfer 0F90H ~ 0F91H 010: 3 words transfer 0F90H ~ 0F92H 011: 4 words transfer 0F90H ~ 0F93H 100: 5 words transfer 0F90H ~ 0F94H 101: 6 words transfer 0F90H ~ 0F95H 110: 7 words transfer 0F90H ~ 0F96H 111: 8 words transfer 0F90H ~ 0F97H Write only Note 1: The lower 4 bits of each buffer are used during 4-bit transfers. Zeros (0) are stored to the upper 4bits when receiving. Note 2: Transmitting starts at the lowest address. Received data are also stored starting from the lowest address to the highest address. ( The first buffer address transmitted is 0F90H ). Note 3: The value to be loaded to BUF is held after transfer is completed. Note 4: SIOCR2 must be set when the serial interface is stopped (SIOF = 0). Note 5: *: Don't care Note 6: SIOCR2 is write-only register, which cannot access any of in read-modify-write instruction such as bit operate, etc. SIO Status Register SIOSR 7 6 (0F99H) SIOF SEF SIOF SEF 5 4 3 2 1 Serial transfer operating status monitor 0: 1: Transfer terminated Transfer in process Shift operating status monitor 0: 1: Shift operation terminated Shift operation in process 0 Note 1: Tf; Frame time, TD; Data transfer time Note 2: After SIOS is cleared to "0", SIOF is cleared to "0" at the termination of transfer or the setting of SIOINH to "1". (output) SCK output TD Tf Figure 12-2 Frame time (Tf) and Data transfer time (TD) 12.3 Serial clock 12.3.1 Clock source Internal clock or external clock for the source clock is selected by SIOCR1<SCK>. Page 139 Read only 12. Synchronous Serial Interface (SIO) 12.3 Serial clock TMP86CM23AUG 12.3.1.1 Internal clock Any of six frequencies can be selected. The serial clock is output to the outside on the SCK pin. The SCK pin goes high when transfer starts. When data writing (in the transmit mode) or reading (in the receive mode or the transmit/receive mode) cannot keep up with the serial clock rate, there is a wait function that automatically stops the serial clock and holds the next shift operation until the read/write processing is completed. Table 12-1 Serial Clock Rate NORMAL1/2, IDLE1/2 mode DV7CK = 0 SLOW1/2, SLEEP1/2 mode DV7CK = 1 SCK Clock Baud Rate Clock Baud Rate Clock Baud Rate 000 fc/213 1.91 Kbps fs/25 1024 bps fs/25 1024 bps 001 fc/28 61.04 Kbps fc/28 61.04 Kbps - - 010 fc/27 122.07 Kbps fc/27 122.07 Kbps - - 011 fc/26 244.14 Kbps fc/26 244.14 Kbps - - 100 fc/25 488.28 Kbps fc/25 488.28 Kbps - - 101 fc/24 976.56 Kbps fc/24 976.56 Kbps - - 110 - - - - - - 111 External External External External External External Note: 1 Kbit = 1024 bit (fc = 16 MHz, fs = 32.768 kHz) Automatically wait function SCK pin (output) SO a0 pin (output) Written transmit data a1 a2 a3 a b0 b b1 b2 b3 c0 c1 c Figure 12-3 Automatic Wait Function (at 4-bit transmit mode) 12.3.1.2 External clock An external clock connected to the SCK pin is used as the serial clock. In this case, output latch of this port should be set to "1". To ensure shifting, a pulse width of at least 4 machine cycles is required. This pulse is needed for the shift operation to execute certainly. Actually, there is necessary processing time for interrupting, writing, and reading. The minimum pulse is determined by setting the mode and the program. Therfore, maximum transfer frequency will be 488.3K bit/sec (at fc=16MHz). SCK pin (Output) tcyc = 4/fc (In the NORMAL1/2, IDLE1/2 modes) 4/fs (In the SLOW1/2, SLEEP1/2 modes) tSCKL, tSCKH > 4tcyc tSCKL tSCKH Figure 12-4 External clock pulse width Page 140 TMP86CM23AUG 12.3.2 Shift edge The leading edge is used to transmit, and the trailing edge is used to receive. 12.3.2.1 Leading edge Transmitted data are shifted on the leading edge of the serial clock (falling edge of the SCK pin input/ output). 12.3.2.2 Trailing edge Received data are shifted on the trailing edge of the serial clock (rising edge of the SCK pin input/output). SCK pin SO pin Bit 0 Bit 1 Bit 2 Bit 3 Shift register 3210 *321 **32 ***3 Bit 2 Bit 3 (a) Leading edge SCK pin Bit 0 SI pin Shift register Bit 1 0*** **** 10** 210* 3210 *; Don’t care (b) Trailing edge Figure 12-5 Shift edge 12.4 Number of bits to transfer Either 4-bit or 8-bit serial transfer can be selected. When 4-bit serial transfer is selected, only the lower 4 bits of the transmit/receive data buffer register are used. The upper 4 bits are cleared to “0” when receiving. The data is transferred in sequence starting at the least significant bit (LSB). 12.5 Number of words to transfer Up to 8 words consisting of 4 bits of data (4-bit serial transfer) or 8 bits (8-bit serial transfer) of data can be transferred continuously. The number of words to be transferred can be selected by SIOCR2<BUF>. An INTSIO interrupt is generated when the specified number of words has been transferred. If the number of words is to be changed during transfer, the serial interface must be stopped before making the change. The number of words can be changed during automatic-wait operation of an internal clock. In this case, the serial interface is not required to be stopped. Page 141 12. Synchronous Serial Interface (SIO) 12.6 Transfer Mode TMP86CM23AUG SCK pin SO pin a0 a1 a2 a3 INTSIO interrupt (a) 1 word transmit SCK pin SO pin a0 a1 a2 a3 b0 b1 b2 b3 c0 c1 c2 c3 b3 c0 c1 c2 c3 INTSIO interrupt (b) 3 words transmit SCK pin SI pin a0 a1 a2 a3 b0 b1 b2 INTSIO interrupt (c) 3 words receive Figure 12-6 Number of words to transfer (Example: 1word = 4bit) 12.6 Transfer Mode SIOCR1<SIOM> is used to select the transmit, receive, or transmit/receive mode. 12.6.1 4-bit and 8-bit transfer modes In these modes, firstly set the SIO control register to the transmit mode, and then write first transmit data (number of transfer words to be transferred) to the data buffer registers (DBR). After the data are written, the transmission is started by setting SIOCR1<SIOS> to “1”. The data are then output sequentially to the SO pin in synchronous with the serial clock, starting with the least significant bit (LSB). As soon as the LSB has been output, the data are transferred from the data buffer register to the shift register. When the final data bit has been transferred and the data buffer register is empty, an INTSIO (Buffer empty) interrupt is generated to request the next transmitted data. When the internal clock is used, the serial clock will stop and an automatic-wait will be initiated if the next transmitted data are not loaded to the data buffer register by the time the number of data words specified with the SIOCR2<BUF> has been transmitted. Writing even one word of data cancels the automatic-wait; therefore, when transmitting two or more words, always write the next word before transmission of the previous word is completed. Note:Automatic waits are also canceled by writing to a DBR not being used as a transmit data buffer register; therefore, during SIO do not use such DBR for other applications. For example, when 3 words are transmitted, do not use the DBR of the remained 5 words. When an external clock is used, the data must be written to the data buffer register before shifting next data. Thus, the transfer speed is determined by the maximum delay time from the generation of the interrupt request to writing of the data to the data buffer register by the interrupt service program. The transmission is ended by clearing SIOCR1<SIOS> to “0” or setting SIOCR1<SIOINH> to “1” in buffer empty interrupt service program. Page 142 TMP86CM23AUG SIOCR1<SIOS> is cleared, the operation will end after all bits of words are transmitted. That the transmission has ended can be determined from the status of SIOSR<SIOF> because SIOSR<SIOF> is cleared to “0” when a transfer is completed. When SIOCR1<SIOINH> is set, the transmission is immediately ended and SIOSR<SIOF> is cleared to “0”. When an external clock is used, it is also necessary to clear SIOCR1<SIOS> to “0” before shifting the next data; If SIOCR1<SIOS> is not cleared before shift out, dummy data will be transmitted and the operation will end. If it is necessary to change the number of words, SIOCR1<SIOS> should be cleared to “0”, then SIOCR2<BUF> must be rewritten after confirming that SIOSR<SIOF> has been cleared to “0”. Clear SIOS SIOCR1<SIOS> SIOSR<SIOF> SIOSR<SEF> SCK pin (Output) SO pin a0 a1 a2 a3 a4 a5 a6 a7 b0 b1 b2 b3 b4 b5 b6 b7 INTSIO interrupt a DBR b Write Write (a) (b) Figure 12-7 Transfer Mode (Example: 8bit, 1word transfer, Internal clock) Clear SIOS SIOCR1<SIOS> SIOSR<SIOF> SIOSR<SEF> SCK pin (Input) a0 SO pin a1 a2 a3 a4 a5 a6 a7 b0 b1 b2 b3 b4 b5 b6 b7 INTSIO interrupt DBR a b Write Write (a) (b) Figure 12-8 Transfer Mode (Example: 8bit, 1word transfer, External clock) Page 143 12. Synchronous Serial Interface (SIO) 12.6 Transfer Mode TMP86CM23AUG SCK pin SIOSR<SIOF> MSB of last word SO pin tSODH = min 3.5/fc [s] ( In the NORMAL1/2, IDLE1/2 modes) tSODH = min 3.5/fs [s] (In the SLOW1/2, SLEEP1/2 modes) Figure 12-9 Transmiiied Data Hold Time at End of Transfer 12.6.2 4-bit and 8-bit receive modes After setting the control registers to the receive mode, set SIOCR1<SIOS> to “1” to enable receiving. The data are then transferred to the shift register via the SI pin in synchronous with the serial clock. When one word of data has been received, it is transferred from the shift register to the data buffer register (DBR). When the number of words specified with the SIOCR2<BUF> has been received, an INTSIO (Buffer full) interrupt is generated to request that these data be read out. The data are then read from the data buffer registers by the interrupt service program. When the internal clock is used, and the previous data are not read from the data buffer register before the next data are received, the serial clock will stop and an automatic-wait will be initiated until the data are read. A wait will not be initiated if even one data word has been read. Note:Waits are also canceled by reading a DBR not being used as a received data buffer register is read; therefore, during SIO do not use such DBR for other applications. When an external clock is used, the shift operation is synchronized with the external clock; therefore, the previous data are read before the next data are transferred to the data buffer register. If the previous data have not been read, the next data will not be transferred to the data buffer register and the receiving of any more data will be canceled. When an external clock is used, the maximum transfer speed is determined by the delay between the time when the interrupt request is generated and when the data received have been read. The receiving is ended by clearing SIOCR1<SIOS> to “0” or setting SIOCR1<SIOINH> to “1” in buffer full interrupt service program. When SIOCR1<SIOS> is cleared, the current data are transferred to the buffer. After SIOCR1<SIOS> cleared, the receiving is ended at the time that the final bit of the data has been received. That the receiving has ended can be determined from the status of SIOSR<SIOF>. SIOSR<SIOF> is cleared to “0” when the receiving is ended. After confirmed the receiving termination, the final receiving data is read. When SIOCR1<SIOINH> is set, the receiving is immediately ended and SIOSR<SIOF> is cleared to “0”. (The received data is ignored, and it is not required to be read out.) If it is necessary to change the number of words in external clock operation, SIOCR1<SIOS> should be cleared to “0” then SIOCR2<BUF> must be rewritten after confirming that SIOSR<SIOF> has been cleared to “0”. If it is necessary to change the number of words in internal clock, during automatic-wait operation which occurs after completion of data receiving, SIOCR2<BUF> must be rewritten before the received data is read out. Note:The buffer contents are lost when the transfer mode is switched. If it should become necessary to switch the transfer mode, end receiving by clearing SIOCR1<SIOS> to “0”, read the last data and then switch the transfer mode. Page 144 TMP86CM23AUG Clear SIOS SIOCR1<SIOS> SIOSR<SIOF> SIOSR<SEF> SCK pin (Output) a0 SI pin a1 a2 a3 a4 a5 a6 a7 b0 b1 b2 b3 b4 b5 b6 b7 INTSIO Interrupt DBR a b Read out Read out Figure 12-10 Receive Mode (Example: 8bit, 1word transfer, Internal clock) 12.6.3 8-bit transfer / receive mode After setting the SIO control register to the 8-bit transmit/receive mode, write the data to be transmitted first to the data buffer registers (DBR). After that, enable the transmit/receive by setting SIOCR1<SIOS> to “1”. When transmitting, the data are output from the SO pin at leading edges of the serial clock. When receiving, the data are input to the SI pin at the trailing edges of the serial clock. When the all receive is enabled, 8-bit data are transferred from the shift register to the data buffer register. An INTSIO interrupt is generated when the number of data words specified with the SIOCR2<BUF> has been transferred. Usually, read the receive data from the buffer register in the interrupt service. The data buffer register is used for both transmitting and receiving; therefore, always write the data to be transmitted after reading the all received data. When the internal clock is used, a wait is initiated until the received data are read and the next transfer data are written. A wait will not be initiated if even one transfer data word has been written. When an external clock is used, the shift operation is synchronized with the external clock; therefore, it is necessary to read the received data and write the data to be transmitted next before starting the next shift operation. When an external clock is used, the transfer speed is determined by the maximum delay between generation of an interrupt request and the received data are read and the data to be transmitted next are written. The transmit/receive operation is ended by clearing SIOCR1<SIOS> to “0” or setting SIOCR1<SIOINH> to “1” in INTSIO interrupt service program. When SIOCR1<SIOS> is cleared, the current data are transferred to the buffer. After SIOCR1<SIOS> cleared, the transmitting/receiving is ended at the time that the final bit of the data has been transmitted. That the transmitting/receiving has ended can be determined from the status of SIOSR<SIOF>. SIOSR<SIOF> is cleared to “0” when the transmitting/receiving is ended. When SIOCR1<SIOINH> is set, the transmit/receive operation is immediately ended and SIOSR<SIOF> is cleared to “0”. If it is necessary to change the number of words in external clock operation, SIOCR1<SIOS> should be cleared to “0”, then SIOCR2<BUF> must be rewritten after confirming that SIOSR<SIOF> has been cleared to “0”. If it is necessary to change the number of words in internal clock, during automatic-wait operation which occurs after completion of transmit/receive operation, SIOCR2<BUF> must be rewritten before reading and writing of the receive/transmit data. Page 145 12. Synchronous Serial Interface (SIO) 12.6 Transfer Mode TMP86CM23AUG Note:The buffer contents are lost when the transfer mode is switched. If it should become necessary to switch the transfer mode, end receiving by clearing SIOCR1<SIOS> to “0”, read the last data and then switch the transfer mode. Clear SIOS SIOCR1<SIOS> SIOSR<SIOF> SIOSR<SEF> SCK pin (output) SO pin a0 a1 a2 a3 a4 a5 a6 a7 b0 b1 b2 b3 b4 b5 b6 b7 SI pin c0 c1 c2 c3 c4 c5 c6 c7 d0 d1 d2 d3 d4 d5 d6 d7 INTSIO interrupt c a DBR Write (a) Read out (c) b Write (b) d Read out (d) Figure 12-11 Transfer / Receive Mode (Example: 8bit, 1word transfer, Internal clock) SCK pin SIOSR<SIOF> SO pin Bit 6 Bit 7 of last word tSODH = min 4/fc [s] ( In the NORMAL1/2, IDLE1/2 modes) tSODH = min 4/fs [s] (In the SLOW1/2, SLEEP1/2 modes) Figure 12-12 Transmitted Data Hold Time at End of Transfer / Receive Page 146 TMP86CM23AUG 13. 10-bit AD Converter (ADC) The TMP86CM23AUG have a 10-bit successive approximation type AD converter. 13.1 Configuration The circuit configuration of the 10-bit AD converter is shown in Figure 13-1. It consists of control register ADCCR1 and ADCCR2, converted value register ADCDR1 and ADCDR2, a DA converter, a sample-hold circuit, a comparator, and a successive comparison circuit. DA converter VAREF VSS R/2 R R/2 AVDD Analog input multiplexer AIN0 A Sample hold circuit Reference voltage Y 10 Analog comparator n S EN Successive approximate circuit Shift clock AINDS ADRS SAIN INTADC Control circuit 4 ADCCR1 2 AMD IREFON AIN7 3 ACK ADCCR2 AD converter control register 1, 2 8 ADCDR1 2 EOCF ADBF ADCDR2 AD conversion result register 1, 2 Note: Before using AD converter, set appropriate value to I/O port register conbining a analog input port. For details, see the section on "I/O ports". Figure 13-1 10-bit AD Converter Page 147 13. 10-bit AD Converter (ADC) 13.2 Register configuration TMP86CM23AUG 13.2 Register configuration The AD converter consists of the following four registers: 1. AD converter control register 1 (ADCCR1) This register selects the analog channels and operation mode (Software start or repeat) in which to perform AD conversion and controls the AD converter as it starts operating. 2. AD converter control register 2 (ADCCR2) This register selects the AD conversion time and controls the connection of the DA converter (Ladder resistor network). 3. AD converted value register 1 (ADCDR1) This register used to store the digital value fter being converted by the AD converter. 4. AD converted value register 2 (ADCDR2) This register monitors the operating status of the AD converter. AD Converter Control Register 1 ADCCR1 (000EH) 7 ADRS 6 5 AMD 4 3 2 AINDS 1 SAIN AD conversion start 0: 1: AD conversion start AMD AD operating mode 00: 01: 10: 11: AD operation disable Software start mode Reserved Repeat mode AINDS Analog input control 0: 1: Analog input enable Analog input disable Analog input channel select 0000: 0001: 0010: 0011: 0100: 0101: 0110: 0111: 1000: 1001: 1010: 1011: 1100: 1101: 1110: 1111: AIN0 AIN1 AIN2 AIN3 AIN4 AIN5 AIN6 AIN7 Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved ADRS SAIN 0 (Initial value: 0001 0000) R/W Note 1: Select analog input channel during AD converter stops (ADCDR2<ADBF> = "0"). Note 2: When the analog input channel is all use disabling, the ADCCR1<AINDS> should be set to "1". Note 3: During conversion, Do not perform port output instruction to maintain a precision for all of the pins because analog input port use as general input port. And for port near to analog input, Do not input intense signaling of change. Note 4: The ADCCR1<ADRS> is automatically cleared to "0" after starting conversion. Note 5: Do not set ADCCR1<ADRS> newly again during AD conversion. Before setting ADCCR1<ADRS> newly again, check ADCDR2<EOCF> to see that the conversion is completed or wait until the interrupt signal (INTADC) is generated (e.g., interrupt handling routine). Note 6: After STOP or SLOW/SLEEP mode are started, AD converter control register1 (ADCCR1) is all initialized and no data can be written in this register. Therfore, to use AD converter again, set the ADCCR1 newly after returning to NORMAL1 or NORMAL2 mode. Page 148 TMP86CM23AUG AD Converter Control Register 2 7 ADCCR2 (000FH) 6 IREFON ACK 5 4 3 IREFON "1" 2 1 ACK 0 "0" (Initial value: **0* 000*) DA converter (Ladder resistor) connection control 0: 1: Connected only during AD conversion Always connected AD conversion time select (Refer to the following table about the conversion time) 000: 001: 010: 011: 100: 101: 110: 111: 39/fc Reserved 78/fc 156/fc 312/fc 624/fc 1248/fc Reserved R/W Note 1: Always set bit0 in ADCCR2 to "0" and set bit4 in ADCCR2 to "1". Note 2: When a read instruction for ADCCR2, bit6 to 7 in ADCCR2 read in as undefined data. Note 3: After STOP or SLOW/SLEEP mode are started, AD converter control register2 (ADCCR2) is all initialized and no data can be written in this register. Therfore, to use AD converter again, set the ADCCR2 newly after returning to NORMAL1 or NORMAL2 mode. Table 13-1 ACK setting and Conversion time Condition ACK 000 Conversion time 16 MHz 8 MHz 4 MHz 2 MHz 10 MHz 5 MHz 2.5 MHz 39/fc - - - 19.5 µs - - 15.6 µs 001 Reserved 010 78/fc - - 19.5 µs 39.0 µs - 15.6 µs 31.2 µs 011 156/fc - 19.5 µs 39.0 µs 78.0 µs 15.6 µs 31.2 µs 62.4 µs 100 312/fc 19.5 µs 39.0 µs 78.0 µs 156.0 µs 31.2 µs 62.4 µs 124.8 µs 101 624/fc 39.0 µs 78.0 µs 156.0 µs - 62.4 µs 124.8 µs - 110 1248/fc 78.0 µs 156.0 µs - - 124.8 µs - - 111 Reserved Note 1: Setting for "−" in the above table are inhibited. fc: High Frequency oscillation clock [Hz] Note 2: Set conversion time setting should be kept more than the following time by Analog reference voltage (VAREF) . - VAREF = 4.5 to 5.5 V 15.6 µs and more - VAREF = 2.7 to 5.5 V 31.2 µs and more - VAREF = 1.8 to 5.5 V 124.8 µs and more AD Converted value Register 1 ADCDR1 (0021H) 7 6 5 4 3 2 1 0 AD09 AD08 AD07 AD06 AD05 AD04 AD03 AD02 3 2 1 0 (Initial value: 0000 0000) AD Converted value Register 2 ADCDR2 (0020H) 7 6 5 4 AD01 AD00 EOCF ADBF (Initial value: 0000 ****) Page 149 13. 10-bit AD Converter (ADC) 13.2 Register configuration TMP86CM23AUG EOCF ADBF AD conversion end flag 0: 1: Before or during conversion Conversion completed AD conversion BUSY flag 0: 1: During stop of AD conversion During AD conversion Read only Note 1: The ADCDR2<EOCF> is cleared to "0" when reading the ADCDR1. Therfore, the AD conversion result should be read to ADCDR2 more first than ADCDR1. Note 2: The ADCDR2<ADBF> is set to "1" when AD conversion starts, and cleared to "0" when AD conversion finished. It also is cleared upon entering STOP mode or SLOW mode . Note 3: If a read instruction is executed for ADCDR2, read data of bit3 to bit0 are unstable. Page 150 TMP86CM23AUG 13.3 Function 13.3.1 Software Start Mode After setting ADCCR1<AMD> to “01” (software start mode), set ADCCR1<ADRS> to “1”. AD conversion of the voltage at the analog input pin specified by ADCCR1<SAIN> is thereby started. After completion of the AD conversion, the conversion result is stored in AD converted value registers (ADCDR1, ADCDR2) and at the same time ADCDR2<EOCF> is set to 1, the AD conversion finished interrupt (INTADC) is generated. ADRS is automatically cleared after AD conversion has started. Do not set ADCCR1<ADRS> newly again (Restart) during AD conversion. Before setting ADRS newly again, check ADCDR2<EOCF> to see that the conversion is completed or wait until the interrupt signal (INTADC) is generated (e.g., interrupt handling routine). AD conversion start AD conversion start ADCCR1<ADRS> ADCDR2<ADBF> ADCDR1 status Indeterminate 1st conversion result 2nd conversion result EOCF cleared by reading conversion result ADCDR2<EOCF> INTADC interrupt request ADCDR1 ADCDR2 Conversion result read Conversion result read Conversion result read Conversion result read Figure 13-2 Software Start Mode 13.3.2 Repeat Mode AD conversion of the voltage at the analog input pin specified by ADCCR1<SAIN> is performed repeatedly. In this mode, AD conversion is started by setting ADCCR1<ADRS> to “1” after setting ADCCR1<AMD> to “11” (Repeat mode). After completion of the AD conversion, the conversion result is stored in AD converted value registers (ADCDR1, ADCDR2) and at the same time ADCDR2<EOCF> is set to 1, the AD conversion finished interrupt (INTADC) is generated. In repeat mode, each time one AD conversion is completed, the next AD conversion is started. To stop AD conversion, set ADCCR1<AMD> to “00” (Disable mode) by writing 0s. The AD convert operation is stopped immediately. The converted value at this time is not stored in the AD converted value register. Page 151 13. 10-bit AD Converter (ADC) 13.3 Function TMP86CM23AUG ADCCR1<AMD> “11” “00” AD conversion start ADCCR1<ADRS> 1st conversion result Conversion operation Indeterminate ADCDR1,ADCDR2 2nd conversion result 3rd conversion result 1st conversion result 2nd conversion result AD convert operation suspended. Conversion result is not stored. 3rd conversion result ADCDR2<EOCF> EOCF cleared by reading conversion result INTADC interrupt request ADCDR1 Conversion result read ADCDR2 Conversion result read Conversion result read Conversion result read Conversion result read Conversion result read Figure 13-3 Repeat Mode 13.3.3 Register Setting 1. Set up the AD converter control register 1 (ADCCR1) as follows: • Choose the channel to AD convert using AD input channel select (SAIN). • Specify analog input enable for analog input control (AINDS). • Specify AMD for the AD converter control operation mode (software or repeat mode). 2. Set up the AD converter control register 2 (ADCCR2) as follows: • Set the AD conversion time using AD conversion time (ACK). For details on how to set the conversion time, refer to Figure 13-1 and AD converter control register 2. • Choose IREFON for DA converter control. 3. After setting up (1) and (2) above, set AD conversion start (ADRS) of AD converter control register 1 (ADCCR1) to “1”. If software start mode has been selected, AD conversion starts immediately. 4. After an elapse of the specified AD conversion time, the AD converted value is stored in AD converted value register 1 (ADCDR1) and the AD conversion finished flag (EOCF) of AD converted value register 2 (ADCDR2) is set to “1”, upon which time AD conversion interrupt INTADC is generated. 5. EOCF is cleared to “0” by a read of the conversion result. However, if reconverted before a register read, although EOCF is cleared the previous conversion result is retained until the next conversion is completed. Page 152 TMP86CM23AUG Example :After selecting the conversion time 19.5 µs at 16 MHz and the analog input channel AIN3 pin, perform AD conversion once. After checking EOCF, read the converted value, store the lower 2 bits in address 0009EH nd store the upper 8 bits in address 0009FH in RAM. The operation mode is software start mode. SLOOP : : (port setting) : ;Set port register approrriately before setting AD converter registers. : : (Refer to section I/O port in details) LD (ADCCR1) , 00100011B ; Select AIN3 LD (ADCCR2) , 11011000B ;Select conversion time(312/fc) and operation mode SET (ADCCR1) . 7 ; ADRS = 1(AD conversion start) TEST (ADCDR2) . 5 ; EOCF= 1 ? JRS T, SLOOP LD A , (ADCDR2) LD (9EH) , A LD A , (ADCDR1) LD (9FH), A ; Read result data ; Read result data 13.4 STOP/SLOW Modes during AD Conversion When standby mode (STOP or SLOW mode) is entered forcibly during AD conversion, the AD convert operation is suspended and the AD converter is initialized (ADCCR1 and ADCCR2 are initialized to initial value). Also, the conversion result is indeterminate. (Conversion results up to the previous operation are cleared, so be sure to read the conversion results before entering standby mode (STOP or SLOW mode).) When restored from standby mode (STOP or SLOW mode), AD conversion is not automatically restarted, so it is necessary to restart AD conversion. Note that since the analog reference voltage is automatically disconnected, there is no possibility of current flowing into the analog reference voltage. Page 153 13. 10-bit AD Converter (ADC) 13.5 Analog Input Voltage and AD Conversion Result TMP86CM23AUG 13.5 Analog Input Voltage and AD Conversion Result The analog input voltage is corresponded to the 10-bit digital value converted by the AD as shown in Figure 13-4. 3FFH 3FEH 3FDH AD conversion result 03H 02H 01H VAREF 0 1 2 3 1021 1022 1023 1024 Analog input voltage VSS 1024 Figure 13-4 Analog Input Voltage and AD Conversion Result (Typ.) Page 154 TMP86CM23AUG 13.6 Precautions about AD Converter 13.6.1 Restrictions for AD Conversion interrupt (INTADC) usage When an AD interrupt is used, it may not be processed depending on program composition. For example, if an INTADC interrupt request is generated while an interrupt with priority lower than the interrupt latch IL15 (INTADC) is being accepted, the INTADC interrupt latch may be cleared without the INTADC interrupt being processed. The completion of AD conversion can be detected by the following methods: (1) Method not using the AD conversion end interrupt Whether or not AD conversion is completed can be detected by monitoring the AD conversion end flag (EOCF) by software. This can be done by polling EOCF or monitoring EOCF at regular intervals after start of AD conversion. (2) Method for detecting AD conversion end while a lower-priority interrupt is being processed While an interrupt with priority lower than INTADC is being processed, check the AD conversion end flag (EOCF) and interrupt latch IL15. If IL15 = 0 and EOCF = 1, call the AD conversion end interrupt processing routine with consideration given to PUSH/POP operations. At this time, if an interrupt request with priority higher than INTADC has been set, the AD conversion end interrupt processing routine will be executed first against the specified priority. If necessary, we recommend that the AD conversion end interrupt processing routine be called after checking whether or not an interrupt request with priority higher than INTADC has been set. 13.6.2 Analog input pin voltage range Make sure the analog input pins (AIN0 to AIN7) are used at voltages within VAREF to VSS. If any voltage outside this range is applied to one of the analog input pins, the converted value on that pin becomes uncertain. The other analog input pins also are affected by that. 13.6.3 Analog input shared pins The analog input pins (AIN0 to AIN7) are shared with input/output ports. When using any of the analog inputs to execute AD conversion, do not execute input/output instructions for all other ports. This is necessary to prevent the accuracy of AD conversion from degrading. Not only these analog input shared pins, some other pins may also be affected by noise arising from input/output to and from adjacent pins. 13.6.4 Noise Countermeasure The internal equivalent circuit of the analog input pins is shown in Figure 13-5. The higher the output impedance of the analog input source, more easily they are susceptible to noise. Therefore, make sure the output impedance of the signal source in your design is 5 kΩ or less. Toshiba also recommends attaching a capacitor external to the chip. Internal resistance AINi Permissible signal source impedance 5 kΩ (typ) Analog comparator Internal capacitance C = 12 pF (typ.) 5 kΩ (max) DA converter Note) i = 7 to 0 Figure 13-5 Analog Input Equivalent Circuit and Example of Input Pin Processing Page 155 13. 10-bit AD Converter (ADC) 13.6 Precautions about AD Converter TMP86CM23AUG Page 156 TMP86CM23AUG 14. Key-on Wakeup (KWU) In the TMP86CM23AUG, the STOP mode is released by not only P20(INT5/STOP) pin but also four (STOP2 to STOP5) pins. When the STOP mode is released by STOP2 to STOP5 pins, the STOP pin needs to be used. In details, refer to the following section " 14.2 Control ". 14.1 Configuration INT5 STOP STOP mode release signal (1: Release) STOP2 STOP3 STOP4 STOPCR (0F9AH) STOP5 STOP4 STOP3 STOP2 STOP5 Figure 14-1 Key-on Wakeup Circuit 14.2 Control STOP2 to STOP5 pins can controlled by Key-on Wakeup Control Register (STOPCR). It can be configured as enable/disable in 1-bit unit. When those pins are used for STOP mode release, configure corresponding I/O pins to input mode by I/O port register beforehand. Key-on Wakeup Control Register STOPCR 7 6 5 4 (0F9AH) STOP5 STOP4 STOP3 STOP2 3 2 1 0 (Initial value: 0000 ****) STOP5 STOP mode released by STOP5 0:Disable 1:Enable Write only STOP4 STOP mode released by STOP4 0:Disable 1:Enable Write only STOP3 STOP mode released by STOP3 0:Disable 1:Enable Write only STOP2 STOP mode released by STOP2 0:Disable 1:Enable Write only 14.3 Function Stop mode can be entered by setting up the System Control Register (SYSCR1), and can be exited by detecting the "L" level on STOP2 to STOP5 pins, which are enabled by STOPCR, for releasing STOP mode (Note1). Page 157 14. Key-on Wakeup (KWU) 14.3 Function TMP86CM23AUG Also, each level of the STOP2 to STOP5 pins can be confirmed by reading corresponding I/O port data register, check all STOP2 to STOP5 pins "H" that is enabled by STOPCR before the STOP mode is started (Note2,3). Note 1: When the STOP mode released by the edge release mode (SYSCR1<RELM> = “0”), inhibit input from STOP2 to STOP5 pins by Key-on Wakeup Control Register (STOPCR) or must be set "H" level into STOP2 to STOP5 pins that are available input during STOP mode. Note 2: When the STOP pin input is high or STOP2 to STOP5 pins input which is enabled by STOPCR is low, executing an instruction which starts STOP mode will not place in STOP mode but instead will immediately start the release sequence (Warm up). Note 3: The input circuit of Key-on Wakeup input and Port input is separated, so each input voltage threshold value is different. Therefore, a value comes from port input before STOP mode start may be different from a value which is detected by Key-on Wakeup input (Figure 14-2). Note 4: STOP pin doesn’t have the control register such as STOPCR, so when STOP mode is released by STOP2 to STOP5 pins, STOP pin also should be used as STOP mode release function. Note 5: In STOP mode, Key-on Wakeup pin which is enabled as input mode (for releasing STOP mode) by Key-on Wakeup Control Register (STOPCR) may generate the penetration current, so the said pin must be disabled AD conversion input (analog voltage input). Note 6: When the STOP mode is released by STOP2 to STOP5 pins, the level of STOP pin should hold "L" level (Figure 14-3). External pin Port input Key-on wakeup input Figure 14-2 Key-on Wakeup Input and Port Input b) In case of STOP2 to STOP5 a) STOP STOP pin STOP pin "L" STOP mode Release STOP mode STOP2 pin STOP mode Release STOP mode Figure 14-3 Priority of STOP pin and STOP2 to STOP5 pins Table 14-1 Release level (edge) of STOP mode Release level (edge) Pin name SYSCR1<RELM>="1" (Note2) SYSCR1<RELM>="0" STOP "H" level Rising edge STOP2 "L" level Don’t use (Note1) STOP3 "L" level Don’t use (Note1) STOP4 "L" level Don’t use (Note1) STOP5 "L" level Don’t use (Note1) Page 158 TMP86CM23AUG 18. Input/Output Circuitry 18.1 Control Pins The input/output circuitries of the TMP86CM23AUG control pins are shown below. Control Pin I/O Input/Output Circuitry Remarks Osc. enable fc VDD XIN XOUT VDD Rf Input Output RO Resonator connecting pins (high-frequency) Rf = 1.2 MΩ (typ.) RO = 0.5 kΩ (typ.) XIN XOUT XTEN Osc. enable XTIN XTOUT Input Output fs VDD VDD Rf RO Resonator connecting pins (Low-frequency) Rf = 6 MΩ (typ.) RO = 220 kΩ (typ.) XTIN XTOUT VDD RIN RESET Hysteresis input Pull-up resistor RIN = 220 kΩ (typ.) Input Address-trap-reset Watchdog-timer System-clock-reset VDD D1 R TEST Input RIN Page 183 Pull-down resistor RIN = 70 kΩ (typ.) R = 1 kΩ (typ.) 18. Input/Output Circuitry 18.2 Input/Output Ports TMP86CM23AUG 18.2 Input/Output Ports Port I/O Input/Output Circuitry Remarks P1 I/O Tri-state I/O Hysteresis input R = 100 Ω (typ.) LCD segment output P5 P7 P8 I/O Tri-state I/O R = 100 Ω (typ.) LCD segment output P2 I/O Sink open drain output Hysteresis input R = 100 Ω (typ.) P34 to P30 I/O Sink open drain output or C-MOS output Hysteresis input High current output (Nch) (Only P33, P34 port) R = 100 Ω (typ.) P37 to P35 Sink open drain output High current output (Nch) Output P6 I/O Page 184 Tri-state I/O Hysteresis input AIN input R = 100 Ω (typ.) TMP86CM23AUG 19. Electrical Characteristics 19.1 Absolute Maximum Ratings The absolute maximum ratings are rated values which must not be exceeded during operation, even for an instant. Any one of the ratings must not be exceeded. If any absolute maximum rating is exceeded, a device may break down or its performance may be degraded, causing it to catch fire or explode resulting in injury to the user. Thus, when designing products which include this device, ensure that no absolute maximum rating value will ever be exceeded. (VSS = 0 V) Parameter Symbol Pins Ratings Supply voltage VDD −0.3 to 6.5 Input voltage VIN −0.3 to VDD + 0.3 VOUT −0.3 to VDD + 0.3 Output voltage Output current (Per 1 pin) Output current (Total) Power dissipation [Topr = 85°C] IOUT1 P1, P30 to P34, P5, P6, P7, P8 port −1.8 IOUT2 P1, P2, P30 to P32, P5, P6, P7, P8 port 3.2 IOUT3 P33 to P37 port 30 Σ IOUT1 P1, P30 to P34, P5, P6, P7, P8 port −30 Σ IOUT2 P1, P2, P30 to P32, P5, P6, P7, P8 port 60 Σ IOUT3 P33 to P37 port 80 PD 350 Soldering temperature (Time) Tsld 260 (10 s) Storage temperature Tstg −55 to 125 Operating temperature Topr −40 to 85 Page 185 Unit V mA mW °C 19. Electrical Characteristics 19.2 Operating Condition TMP86CM23AUG 19.2 Operating Condition The Operating Conditions show the conditions under which the device be used in order for it to operate normally while maintaining its quality. If the device is used outside the range of Operating Conditions (power supply voltage, operating temperature range, or AC/DC rated values), it may operate erratically. Therefore, when designing your application equipment, always make sure its intended working conditions will not exceed the range of Operating Conditions. (VSS = 0 V, Topr = −40 to 85°C) Parameter Symbol Pins Condition Min Max Unit NORMAL1, 2 mode fc = 16 MHz 3.5 IDLE0, 1, 2 mode NORMAL1, 2 mode fc = 8 MHz 2.7 IDLE0, 1, 2 mode Supply voltage VDD fc = 4.2 MHz NORMAL1, 2 mode fs = 32.768 kHz SLOW1, 2 mode 5.5 IDLE0, 1, 2 mode 1.8 (Note1) SLEEP0, 1, 2 mode V STOP mode Input high level VIH1 Except hysteresis input VIH2 Hysteresis input VDD < 4.5 V VIH3 Input low level VDD ≥ 4.5 V VIL1 Except hysteresis input VIL2 Hysteresis input VDD × 0.70 VDD × 0.75 VDD × 0.90 VDD × 0.30 VDD ≥ 4.5 V 0 VDD = 1.8 V to 5.5 V fc XIN, XOUT fs XTIN, XTOUT Clock frequency VDD = 2.7 V to 5.5 V 4.2 1.0 VDD = 3.5 V to 5.5 V 8.0 MHz 16.0 30.0 Note 1: When the supply voltage is VDD=1.8 to 2.0V, the operating tempreture is Topr= -20 to 85 °C. Page 186 VDD × 0.25 VDD × 0.10 VDD < 4.5 V VIL3 VDD 34.0 kHz TMP86CM23AUG 19.3 DC Characteristics (VSS = 0 V, Topr = −40 to 85°C) Parameter Symbol Pins Hysteresis voltage VHS Hysteresis input IIN1 TEST Input current IIN2 Sink open drain, Tri-state IIN3 RESET, STOP RIN1 TEST pull-down RIN2 RESET pull-up Condition VDD = 5.5 V, VIN = 5.5 V/0 V Min Typ. Max Unit – 0.9 – V – – ±2 µA – 70 – 100 220 450 – – ±2 kΩ Input resistance Output leakage current ILO Sink open drain, Tri-state VDD = 5.5 V, VOUT = 5.5 V/0 V Output high voltage VOH C-MOS, Tri-st port VDD = 4.5 V, IOH = −0.7 mA 4.1 – – Output low voltage VOL Except XOUT and P3 port VDD = 4.5 V, IOL = 1.6 mA – – 0.4 Output low current IOL High current port (P33 to P37 port) VDD = 4.5 V, VOL = 1.0 V – 20 – VDD = 5.5 V – 10.5 15.0 – 6.5 10.0 – 10.0 21.0 – 7.5 16.0 – 5.0 12.0 – 0.5 10 – 20 – µA V Supply current in NORMAL 1, 2 mode VIN = 5.3/0.2 V fc = 16 MHz fs = 32.768 kHz Supply current in IDLE 0, 1, 2 mode Supply current in SLOW 1 mode Supply current in SLEEP 1 mode mA mA VDD = 3.0 V IDD VIN = 2.8/0.2 V fs = 32.768 kHz LCD drive is not enable. Supply current in SLEEP 0 mode VDD = 5.5 V Supply current in STOP mode VIN = 5.3 V/0.2 V Segment output low resistance ROS1 SEG pin Common output low resistance ROC1 COM pin 20 Segment output high resistance ROS2 SEG pin 200 Common output high resistance ROC2 COM pin 200 µA µA kΩ VO2/3 Segment/common output voltage VO1/2 3.8 SEG/COM pin VDD = 5.0 V VLC = 2.0 V VO1/3 3.3 4.2 – 2.8 Note 1: Typical values show those at Topr = 25°C, VDD = 5 V Note 2: Input current (IIN1, IIN2); The current through pull-up or pull-down resistor is not included. Note 3: IDD does not include IREF current. Note 4: The supply currents of SLOW 2 and SLEEP 2 modes are equivalent to IDLE 0, 1, 2. Note 5: Output resistors ROS and ROC indicate "ON" when switching levels. Note 6: VO2/3 indicates the output voltage at the 2/3 level when operating in the 1/4 or 1/3 duty mode. Note 7: VO1/2 indicates the output voltage at the 1/2 level when operating in the 1/2 duty or static mode. Note 8: VO1/3 indicates the output voltage at the 1/3 level when operating in the 1/4 or 1/3 duty mode. Note 9: When using LCD, it is necessary to consider values of ROS1/2 and ROC1/2. Page 187 3.7 3.2 V 19. Electrical Characteristics 19.4 AD Conversion Characteristics TMP86CM23AUG 19.4 AD Conversion Characteristics (VSS = 0.0 V, 4.5 V ≤ VDD ≤ 5.5 V, Topr = −40 to 85°C) Parameter Symbol Analog reference voltage VAREF Power supply voltage of analog control circuit (Note6) AVDD Analog reference voltage range (Note4) ∆VAREF Analog input voltage Power supply current of analog reference voltage Condition Min Typ. Max AVDD − 1.0 – AVDD Unit VDD V VAIN IREF VDD = AVDD = VAREF = 5.5 V VSS = 0.0 V Non linearity error VDD = AVDD = 5.0 V Zero point error VSS = 0.0 V Full scale error VAREF = 5.0 V Total error 3.5 – – VSS – VAREF – 0.6 1.0 – – ±2 – – ±2 – – ±2 – – ±2 mA LSB (VSS = 0.0 V, 2.7 V ≤ VDD < 4.5 V, Topr = −40 to 85°C) Parameter Symbol Analog reference voltage VAREF Condition Min Power supply voltage of analog control circuit (Note6) AVDD Analog reference voltage range (Note4) ∆VAREF 2.5 – – Analog input voltage VAIN VSS – VAREF Power supply current of analog reference voltage IREF – 0.5 0.8 AVDD − 1.0 Typ. Max – AVDD Unit VDD V VDD = AVDD = VAREF = 4.5 V VSS = 0.0 V Non linearity error VDD = AVDD = 2.7 V Zero point error VSS = 0.0 V Full scale error VAREF = 2.7 V Total error – – ±2 – – ±2 – – ±2 – – ±2 mA LSB (VSS = 0.0 V, 2.0 V ≤ VDD < 2.7 V, Topr = −40 to 85°C) (Note5) (VSS = 0.0 V, 1.8 V ≤ VDD < 2.0 V, Topr = −10 to 85°C) (Note5) Parameter Symbol Analog reference voltage VAREF Power supply voltage of analog control circuit (Note6) AVDD Analog reference voltage range (Note4) ∆VAREF Analog input voltage Power supply current of analog reference voltage Condition Zero point error Max AVDD − 0.9 – AVDD 1.8 V ≤ VDD < 2.0 V 1.8 – – 2.0 V ≤ VDD < 2.7 V 2.0 – – VSS – VAREF – 0.3 0.5 – – ±4 VDD = AVDD = VAREF = 2.7 V VSS = 0.0 V Non linearity error Full scale error Typ. Unit VDD VAIN IREF Min VDD = AVDD = 1.8 V VSS = 0.0 V VAREF = 1.8 V Total error – – ±4 – – ±4 – – ±4 V mA LSB Note 1: The total error includes all errors except a quantization error, and is defined as a maximum deviation from the ideal conversion line. Note 2: Conversion time is different in recommended value by power supply voltage. About conversion time, please refer to “Register Configuration”. Note 3: Please use input voltage to AIN input Pin in limit of VAREF to VSS. When voltage of range outside is input, conversion value becomes unsettled and gives affect to other channel conversion value. Page 188 TMP86CM23AUG Note 4: Analog reference voltage range: ∆VAREF = VAREF − VSS Note 5: When AD is used with VDD < 2.7 V, the guaranteed temperature range varies with the operating voltage. Note 6: The AVDD pin should be fixed on the VDD level even though AD converter is not used. 19.5 AC Characteristics (VSS = 0 V, VDD = 3.5 to 5.5 V, Topr = −40 to 85°C) Parameter Symbol Condition Min Typ. Max Unit 0.25 – 4 117.6 – 133.3 For external clock operation (XIN input) fc = 16 MHz – 31.25 – ns For external clock operation (XTIN input) fs = 32.768 kHz – 15.26 – µs NORMAL1, 2 mode IDLE1, 2 mode Machine cycle time µs tcy SLOW1, 2 mode SLEEP1, 2 mode High level clock pulse width tWCH Low level clock pulse width tWCL High level clock pulse width tWCH Low level clock pulse width tWCL (VSS = 0 V, VDD = 2.7 to 5.5 V, Topr = −40 to 85°C) Parameter Symbol Condition Min Typ. Max Unit 0.5 – 4 117.6 – 133.3 For external clock operation (XIN input) fc = 8 MHz – 62.5 – ns For external clock operation (XTIN input) fs = 32.768 kHz – 15.26 – µs NORMAL1, 2 mode IDLE1, 2 mode Machine cycle time µs tcy SLOW1, 2 mode SLEEP1, 2 mode High level clock pulse width tWCH Low level clock pulse width tWCL High level clock pulse width tWCH Low level clock pulse width tWCL (VSS = 0 V, VDD = 1.8 to 5.5 V, Topr = −40 to 85°C) Parameter Symbol Condition Min Typ. Max 0.95 – 4 Unit NORMAL1, 2 mode IDLE1, 2 mode Machine cycle time µs tcy SLOW1, 2 mode 117.6 – 133.3 For external clock operation (XIN input) fc = 4.2 MHz – 119.05 – ns For external clock operation (XTIN input) fs = 32.768 kHz – 15.26 – µs SLEEP1, 2 mode High level clock pulse width tWCH Low level clock pulse width tWCL High level clock pulse width tWCH Low level clock pulse width tWCL Note 1: When the supply voltage is VDD=1.8 to 2.0V, the operating tempreture is Topr= -20 to 85 °C. Page 189 19. Electrical Characteristics 19.6 Timer Counter 1 input (ECIN) Characteristics TMP86CM23AUG 19.6 Timer Counter 1 input (ECIN) Characteristics (VSS = 0 V, Topr = −40 to 85°C) Parameter TC1 input (ECIN input) Symbol tTC1 Condition Min Typ. Frequency measurement mode VDD = 3.5 to 5.5 V Single edge count – – Both edge count – – Frequency measurement mode VDD = 2.7 to 5.5 V Single edge count – – Both edge count – – Frequency measurement mode VDD = 1.8 to 5.5 V Single edge count – – Both edge count – – Max Unit 16 8 MHz 4.2 19.7 Recommended Oscillating Conditions XIN C1 XOUT XTIN C2 XTOUT C1 (1) High-frequency Oscillation C2 (2) Low-frequency Oscillation Note 1: A quartz resonator can be used for high-frequency oscillation only when VDD is 2.7 V or above. If VDD is below 2.7 V, use a ceramic resonator. Note 2: To ensure stable oscillation, the resonator position, load capacitance, etc. must be appropriate. Because these factors are greatly affected by board patterns, please be sure to evaluate operation on the board on which the device will actually be mounted. Note 3: For the resonators to be used with Toshiba microcontrollers, we recommend ceramic resonators manufactured by Murata Manufacturing Co., Ltd. For details, please visit the website of Murata at the following URL: http://www.murata.com 19.8 Handling Precaution - The solderability test conditions for lead-free products (indicated by the suffix G in product name) are shown below. 1. When using the Sn-37Pb solder bath Solder bath temperature = 230 °C Dipping time = 5 seconds Number of times = once R-type flux used 2. When using the Sn-3.0Ag-0.5Cu solder bath Solder bath temperature = 245 °C Dipping time = 5 seconds Number of times = once R-type flux used Note: The pass criteron of the above test is as follows: Solderability rate until forming ≥ 95 % - When using the device (oscillator) in places exposed to high electric fields such as cathode-ray tubes, we recommend electrically shielding the package in order to maintain normal operating condition. Page 190 TMP86CM23AUG 20. Package Dimensions LQFP64-P-1010-0.50D Rev 01 Unit: mm Page 191 20. Package Dimensions TMP86CM23AUG Page 192 This is a technical document that describes the operating functions and electrical specifications of the 8-bit microcontroller series TLCS-870/C (LSI). Toshiba provides a variety of development tools and basic software to enable efficient software development. These development tools have specifications that support advances in microcomputer hardware (LSI) and can be used extensively. Both the hardware and software are supported continuously with version updates. The recent advances in CMOS LSI production technology have been phenomenal and microcomputer systems for LSI design are constantly being improved. The products described in this document may also be revised in the future. Be sure to check the latest specifications before using. Toshiba is developing highly integrated, high-performance microcomputers using advanced MOS production technology and especially well proven CMOS technology. We are prepared to meet the requests for custom packaging for a variety of application areas. We are confident that our products can satisfy your application needs now and in the future.