PolySwitch® PTC Devices Tyco / Electronics Raychem Circuit Protection 308 Constitution Drive Menlo Park, CA 94025-1164 Phone: 800-227-4856 Fax: 800-227-4866 PRODUCT: TR600-150-RB DOCUMENT: SCD 24064 PCN: 688511 REV LETTER: D REV DATE: OCTOBER 23, 2002 PAGE NO.: 1 OF 1 Overcurrent Protection Device Specification Status: Released Max Electrical Rating at 20°C Operating Voltage: 60VDC Fault Voltage: 600VRMS Interrupt Current: 3ARMS Lead Material : 22 AWG Sn/Pb plated copper Marking: Raychem Logo and Voltage 600 150 Part Identification Lot Identification TABLE I. DIMENSIONS: A mm: in: MIN --- B MAX 13.5 (0.531) MIN --- C MAX 12.6 (0.496) MIN --- D MAX MIN 6.0 4.7 (0.236) (0.185) MAX --- E NOM 5.0 (0.197) F MIN --- MAX 10.0 (0.394) TABLE II. PERFORMANCE RATINGS @ 20° C (unless otherwise noted): IHOLD (A) 20° C 0.150 60° C 0.090 RESISTANCE (Ω) TIME TO TRIP (S) OPERATING @ 1A TEMPERATURE (°C) R MIN R MAX R1 MAX* TYP MIN MAX 9.0 12.0 22.0 4.5 -40 85 * Maximum device resistance at 20°C measured 1 hour post-trip. Storage Temperature: -40° to 85°C Agency Recognition: Reference Documents: Precedence: Effectivity: CAUTION: UL, CSA PS300 This specification takes precedence over documents referenced herein. Reference documents shall be the issue in effect on the date of invitation for bid. Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.