PB16HQ MOUNTING BOARD • Plug-compatible logic connections • Screw terminal barrier block for load connections • 5 amp field-replaceable fuses • Input and output modules accepted interchangeably • Operate with 5, 15 or 24 volt logic supplies • Captive-screw retaining system for Quad-Pack (LITTLEFUSE #251005 or equivalent) modules • All even-numbered logic connections are logic ground MECHANICAL SPECIFICATIONS 6.75 (171,5) DIMENSIONS: INCHES (MILLIMETERS) TOLERANCE: ± 0.20 ± (0,50) 6.0 (152,4) 0.375 (9,5) REPLACEABLE 1A LOGIC SUPPLY FUSE (SEE NOTE 4) +5V GND c c 1 2 3 4 c c 5 6 7 8 c c 9 10 c c 13 14 11 12 15 16 F1A POWER BARRIER STRIPS (SEE NOTE 2,3) TB2 R1 D2 4.5 (114,3) 5.0 (127,0) PWR ON LOGIC SUPPLY BARRIER STRIP J3 F2 F1 NEGATIVE (-) LOGIC SUPPLY BUS TERMINATION F3 F5 F4 F6 REPLACEABLE POWER LINE FUSE (8) (SEE NOTE 5) F8 F7 D1 GORDOS QUAD PACK DIGITAL DIFITAL I/O MODULES SOLD SEPERATELY J1 PIN 5V JUMPERS J2 3.75 (95,3) 0.25 (6,4) F9 JUMPERS CONNECTING LOGIC SUPPLY THROUGH HEADER CONNECTOR SWAGED STANDOFF THRU HOLE 0.15 (3,8) DIA X 0.65 (16,5) LONG (4) 0-3 4-7 CROUZET 57 - 463 PB - 16HO SPARE 5A FUSE PIN 49 SPARE 5A LINE FUSE (SEE NOTE 5) 12 - 15 8 - 11 SIGNAL INPUT/OUTPUT 50 CONDUCTOR MALE PIN CONNETOR (SEE NOTE 1) POSITIVE (+) LOGIC SUPPLY BUS TERMINATION NOTES: 1) CONNECTOR IS BERG 65863-145 OR EQUIVALENT. 2) 6-32 SCREW TERMINAL BARRIER STRIPS ACCEPT WIRE SIZES FROM 24 TO 12 AWG. 3) OPTIONAL JUMPERS AVAILABLE TO INTERCONNECT BARRIER STRIP COMMONS. ORDER 2 EACH JUMPER "JQ4". 4) LITTLE FUSE 251001 OR EQUIVALENT. 5) LITTLE FUSE 251005 OR EQUIVALENT. 1 LOGIC SUPPLY BARRIER STRIP +5V GND (-) 3 C 5 C 7 9 C 11 13 C 15 LOWER BARRIER STRIP 2 C 4 6 C 8 10 C 12 14 C 16 UPPER BARRIER STRIP D1 1A LOGIC FUSE 1 49 SIGNAL INPUT/OUTPUT 50 CONDUCTOR MALE PIN CONNECTOR TO G1 BOARD OR RIBBON CABLE PWR ON J1 EVEN PINS 2-50 LOGIC SUPPLY BUS TERMINATION 5A LINE FUSES (8) 1 8 1 8 1 8 1 2 9 2 9 2 9 2 9 3 10 3 10 3 10 3 10 4 11 4 11 4 11 4 11 5 12 5 12 5 12 5 12 6 13 6 13 6 13 6 13 7 14 7 14 7 14 7 14 8 I/O MODULE PIN SOCKETS 47 45 43 41 39 37 35 33 31 29 27 25 23 21 19 17 + - Rev. 070808 DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. • Disconnect all power before installing or working with this equipment. • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSI ONE. • Spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa apparecchiatu ra • Verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one L'omissione di seguire queste istruz ioni provocherà la morte o di lesioni serie RISCO DE DESCARGA ELÉTTRICA OU EXPLOSÃO • Desconectar o equipamento de toda á energia antes de instalar ou trabalhar com este equipamen to • Verificar todas as conexões e recolocar todas as tampas antes de religar o equipamento O não cumprimento destas instruções pode levar á morte ou lesões sérias. ANNEX - ENVIROMENTAL INFORMATION