P B16HQ

PB-16HQ
MOUNTING BOARD
• Plug-compatible logic connections
• Screw terminal barrier block for load connections
• 5 amp field-replaceable fuses
• Input and output modules accepted interchangeably
• Operate with 5, 15 or 24 volt logic supplies
• Captive-screw retaining system for Quad-Pack
(LITTLEFUSE #251005 or equivalent)
modules
• All even-numbered logic connections are
logic ground
MECHANICAL SPECIFICATIONS
6.75 (171,5)
DIMENSIONS: INCHES (MILLIMETERS)
TOLERANCE: ± 0.20 ± (0,50)
6.0 (152,4)
0.375 (9,5)
REPLACEABLE 1A
LOGIC SUPPLY FUSE
(SEE NOTE 4)
+5V GND
c
c
1
2
3
4
c
c
5
6
7
8
c
c
9
10
c
c
13
14
11
12
15
16
F1A
POWER BARRIER STRIPS
(SEE NOTE 2,3)
TB2
R1
D2
4.5 (114,3)
5.0 (127,0)
PWR
ON
LOGIC SUPPLY
BARRIER STRIP
J3
F2
F1
NEGATIVE (-)
LOGIC SUPPLY
BUS TERMINATION
F3
F5
F4
F6
REPLACEABLE POWER
LINE FUSE (8)
(SEE NOTE 5)
F8
F7
D1
GORDOS QUAD PACK DIGITAL
DIFITAL I/O MODULES
SOLD SEPERATELY
J1
PIN
5V JUMPERS
J2
3.75 (95,3)
0.25 (6,4)
F9
JUMPERS
CONNECTING LOGIC
SUPPLY THROUGH
HEADER CONNECTOR
SWAGED STANDOFF
THRU HOLE
0.15 (3,8) DIA
X 0.65 (16,5) LONG (4)
0-3
4-7
CROUZET
57 - 463
PB - 16HO
SPARE 5A FUSE
PIN 49
SPARE 5A LINE FUSE
(SEE NOTE 5)
12 - 15
8 - 11
SIGNAL INPUT/OUTPUT
50 CONDUCTOR MALE PIN
CONNETOR (SEE NOTE 1)
POSITIVE (+)
LOGIC SUPPLY
BUS TERMINATION
NOTES:
1) CONNECTOR IS BERG 65863-145 OR EQUIVALENT.
2) 6-32 SCREW TERMINAL BARRIER STRIPS ACCEPT WIRE SIZES FROM 24 TO 12 AWG.
3) OPTIONAL JUMPERS AVAILABLE TO INTERCONNECT BARRIER
STRIP COMMONS. ORDER 2 EACH JUMPER "JQ4".
4) LITTLE FUSE 251001 OR EQUIVALENT.
5) LITTLE FUSE 251005 OR EQUIVALENT.
1
LOGIC SUPPLY
BARRIER STRIP
+5V GND (-)
3
C
5
C
7
9
C
11
13
C
15
LOWER BARRIER STRIP
2
C
4
6
C
8
10
C
12
14
C
16
UPPER BARRIER STRIP
D1
1A LOGIC
FUSE
1
49
SIGNAL
INPUT/OUTPUT
50 CONDUCTOR
MALE PIN
CONNECTOR TO
G1 BOARD OR
RIBBON
CABLE
PWR
ON
J1
EVEN 2-50
PINS
LOGIC SUPPLY
BUS TERMINATION
5A LINE FUSES (8)
1
8
1
8
1
8
1
2
9
2
9
2
9
2
9
3
10
3
10
3
10
3
10
4
11
4
11
4
11
4
11
5
12
5
12
5
12
5
12
6
13
6
13
6
13
6
13
7
14
7
14
7
14
7
14
8
I/O MODULE
PIN SOCKETS
47
45
43
41
39
37
35
33
31
29
27
25
23
21
19
17
+
-
Rev. 020410
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
• Disconnect all
power before
installing or
working with
this equipment.
• Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSI
ONE.
• Spenga tutta
l'alimentazion
e che fornisce
questa
apparecchiatu
ra prima del
lavorare a questa
apparecchiatu ra
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima della
rotazione
sull'alimentazi one
L'omissione di
seguire queste
istruz ioni
provocherà la
morte o di
lesioni serie
RISCO DE
DESCARGA
ELÉTTRICA OU
EXPLOSÃO
• Desconectar
o equipamento
de toda á
energia antes
de instalar ou
trabalhar com
este equipamen
to
• Verificar todas
as conexões e
recolocar todas
as tampas
antes de religar
o equipamento
O não cumprimento
destas instruções
pode levar á morte
ou lesões sérias.
ANNEX - ENVIROMENTAL INFORMATION