BEL SS-37000-007

CAT6a Large Diameter Modular Plugs
RoHS
Compliant
Features & Benefits
•
Field installable plug for cable conductors up to 0.048” and overall diameters
up to .295”
•
Suitable for CAT6a and CAT6 applications delivering 10G Base-T and Gigabit
Ethernet
Loadbar and wire aligner system provide for consistent assembly and stable electrical
performance.
•
Low profile design allows for use in high density switches and routers
•
Anti-snag boot prevents plug tab damage during installation
•
Packaging available for both field installation and factory terminations
•
Can be used to terminate both shielded and unshielded cabling
Part Number
Performance
Conductor
Diameter
Cable
Diameter
Packaging
SS-39200-027
CAT6a
.042"-.048"
[1.07 - 1.22]
.270"-.295"
[6.86 - 7.49]
Individually
Bagged
SS-39200-030
CAT6a
.042"-.048"
[1.07 - 1.22]
.270"-.295"
[6.86 - 7.49]
Bulk
Bel Stewart Connector’s new modular plug is designed to terminate directly to CAT6a and CAT6 large diameter
solid conductor cabling. Typical modular plugs are designed for use on patch cable assemblies and therefore are designed to
terminate to stranded conductors of wire sizes from AWG 24 through AWG 28. However, in many direct connect, or consolidation
point applications where link lengths exceed 10 Meters, a horizontal cable type is specified. Horizontal cable is normally made
with solid conductor copper wire in the diameter range of AWG 23 through AWG 24. This larger copper size translates into larger
conductor diameters which make terminating to a traditional modular plug problematic. Bel Stewart’s unique loadbar and contact
design accommodates this large diameter cabling in the form factor of a standard RJ45 plug. To learn more visit www.belstewart.com.
11118 Susquehanna Trail South Glen Rock, PA 17327 Tel: 717.235.7512 Fax: 717.235.4675 Document number US/LIT-CAT6a Large Diav04.13 @2013 Bel connector Inc.
Specification Subject To Change
Bel Stewart Connector Modular Plug Quick Reference Guide
Low Volume Terminations
RoHS
Compliant
High Volume Factory Terminations
Part Number
Performance
Shield
Strain Relief Boot
Cable Diameter
Conductor Diameter
Installation Hand Tool Kit
Production Hand Tool
Production Die Set
Termination Instructions
SS-39100-028
CAT6a
No
Slimline Included
.300” [7.62] Max
.033”-.038” [0.84 - 0.97]
2990003-01
2940231-01
2905014-01
MN390014.PDF
SS-39100-029
CAT6a
No
Not Included
.235” [5.97] Max
.037”-.042” [0.94 - 1.07]
2990003-01
2940231-01
2905014-01
MN390014.PDF
SS-39100-030
CAT6a
No
Not Included
.235” [5.97] Max
.033”-.038” [0.84 - 0.97]
2990003-01
2940231-01
2905014-01
MN390014.PDF
SS-39100-031
CAT6a
No
Slimline Included
.235” [5.97] Max
.037”-.042” [0.94 - 1.07]
2990003-01
2940231-01
2905014-01
SS-39200-020
CAT6a
Yes
Slimline Included
.220”-.240” [5.59 - 6.10]
.037”-.042” [0.94 - 1.07]
N/A
2980070-01*
MN390011.PDF
SS-39200-021
CAT6a
Yes
Not Included
.220”-.240” [5.59 - 6.10]
.037”-.042” [0.94 - 1.07]
N/A
2980070-01*
MN390011.PDF
MN390014.PDF
SS-39200-022
CAT6a
Yes
Slimline Included
.230”-.250” [5.84 - 6.35]
.037”-.042” [0.94 - 1.07]
N/A
2980075-01*
MN390011.PDF
SS-39200-023
CAT6a
Yes
Not Included
.230”-.250” [5.84 - 6.35]
.037”-.042” [0.94 - 1.07]
N/A
2980075-01*
MN390011.PDF
SS-39200-024
CAT6a
Yes
Slimline Included
.230”-.250” [5.84 - 6.35]
.033”-.038” [0.84 - 0.97]
N/A
2980075-01*
MN390011.PDF
SS-39200-027
CAT6a
Yes
Slimline Included
.270”-.295” [6.86 - 7.49]
.042”-.048” [1.07 - 1.22]
N/A
2980078-01*
MN390015.PDF
SS-39100-008
CAT6
No
Slimline Included
.220”- .230” [5.59 - 5.84]
.037”-.042” [0.94 - 1.07]
2990009-01
2940231-01
2905029-01
MN390006.PDF
SS-39100-011
CAT6
No
Slimline Included
.240”-.250” [6.10 - 6.35]
.037”-.042” [0.94 - 1.07]
2990009-01
2940231-01
2905029-01
MN390006.PDF
SS-39100-021
CAT6
No
Not included - See
boot PN: 450-034
.235” [5.97] Max
.037”-.042” [0.94 - 1.07]
2990003-01
2940231-01
2905014-01
MN390010.PDF
SS-39200-010
CAT6
Yes
Not Included
.240”-.260” [6.10 - 6.60]
.037”-.042” [0.94 - 1.07]
N/A
2980075-01*
MN390009.PDF
SS-39200-011
CAT6
Yes
Included
.232”-.248” [5.90 - 6.30]
.037”-.042” [0.94 - 1.07]
N/A
2980075-01*
MN390009.PDF
SS-39200-012
CAT6
Yes
Not Included
.220”-.240” [5.59 - 6.10]
.037”-.042” [0.94 - 1.07]
N/A
2980070-01*
MN390009.PDF
SS-39200-015
CAT6
Yes
Included
.220”-.240” [5.59 - 6.10]
.037”-.042” [0.94 - 1.07]
N/A
2980070-01*
MN390009.PDF
SS-39200-019
CAT6
Yes
Not included - See
boot PN: 39200-883
.270”-.295” [6.86 - 7.49]
.037”-.042” [0.94 - 1.07]
N/A
2980078-01*
MN390009.PDF
SS-37000-007
CAT5E
No
Not included - See
boot PN: 450-034
.235” [5.97] Max
.037”-.042” [0.94 - 1.07]
2990003-01
2940231-01
2905014-01
MN370053.PDF
SS-37000-009
CAT5E
No
Not included - See
boot PN: 450-034
.235” [5.97] Max
.042”-.048” [1.07 - 1.22]
2990003-01
2940231-01
2905014-01
MN370053.PDF
SS-37200-028
CAT5E
Yes
Not included - See
boot PN: 450-011
.235” [5.97] Max
.037”-.042” [0.94 - 1.07]
2990003-01
2940231-01
2905014-01
MN370058.PDF
940-SP-3088R-A133
Cat5 / T1
No
Not included - See
boot PN: 450-011
.235” [5.97] Max
.035”-.040” [0.89 - 1.02]
2990003-01
2940231-01
2905005-01
MN300015.PDF
* Tool kits including Hand Tool and Die Set
Bel Stewart has the widest selection of high performance modular plugs available on the market today,
visit www.belstewart.com for our full product line offering.
11118 Susquehanna Trail South Glen Rock, PA 17327 Tel: 717.235.7512 Fax: 717.235.4675 Document number US/LIT-CAT6a Large Diav04.13 @2013 Bel connector Inc.
Specification Subject To Change