1
2
3
Strip off approx. 1.25” of cable
jacket
Fold shield and drain back over
jacket
Trim insulating film layer
0.5”
4
Untwist and Straighten pairs
7
Slide wires into place. Hold
housing at slight angle to cable as
shown
Page 1 of 1
5
6
Arrange pairs (TIA 568-B
shown) and trim at 0.5”
Insert wires into housing
8
Make sure all wires are visible
through end of plug
9
Crimp contacts and strain relief,
then trim shield and drain wire.