SpectrAlert® Advance Description Selectable Output Notification Appliances ® SpectrAlert Advance selectable-output horns, strobes and horn/strobes are rich with features guaranteed to decrease installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify your installations, with features such as the following: • Plug-in designs. • Instant feedback messages to ensure correct installation of individual devices. • Eleven field-selectable candela settings for wall, ceiling strobes and horn/strobes. More specifically, to install the Advance products, do the following: 1. Attach a universal mounting plate to a four-inch square, four-inch octagon, or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. 2. Connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. 3. To attach the horn, strobe, or horn/strobe to the mounting plate, insert the product’s tabs in the mounting plate’s grooves. 4. Rotate the device into position, locking the product’s pins into the mounting plate’s terminals. 5. The device temporarily holds in place with a catch until you secure it with a captured mounting screw. SpectrAlert Advance products offer the following options: • 12 or 24 volts. • At 24 volts, 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 candela by way of rear-mounted slide switch and front viewing window. • Horn tones and volume by way of rotary switch. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (twowire and four-wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between –40°F and 151°F (–40°C and 66°C) in wet or dry applications. 7087pho2.jpg 7087pho1.jpg Indoor Ceiling Horn/Strobe 7087pho4.jpg Outdoor Ceiling Strobe 7087pho5.jpg Indoor Wall Horn Indoor Ceiling Strobe 7087pho3.jpg Indoor Wall Horn/Strobe 7087pho6.jpg Outdoor Wall Strobe Features • Plug-in design. • Same mounting plate for wall- and ceiling-mount units. • Shorting spring on mounting plate for continuity check before installation. • Captive mounting screw. • Tamper-resistance capability. • Field-selectable candela settings on wall or ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. • Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela. • Outdoor wall and ceiling products. • Outdoor products rated from –40°F and 151°F (–40°C and 66°C). • Minimal intrusion into the backbox. • Horn rated at 88+ dbA at 16 volts. • Rotary switch for tone selection.. • Three horn volume settings • Electrically compatible with SpectrAlert® products. Sync•Circuit™ is a trademark, and SpectrAlert® and System Sensor® are registered trademarks of Honeywell International Inc. ©2006 by ADT. All rights reserved. Unauthorized use of this document is strictly prohibited. An ISO 9000-2000 Company SIGNALING MEA S4011 Approved 452-05-E 7125-1653:188 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com CS-2539 Rev. C page 1 of 4 ©2014 Honeywell International Inc. All rights reserved. Models available: Horn/Strobe Combination (Continued) • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non-Temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. 4-wire horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe. • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe. Outdoor Products Engineering Specifications SpectrAlert Advance horns, strobes, and horn/strobes shall mount on a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0" (10.16 cm) octagonal backbox, or a doublegang backbox. Two-wire products shall also mount on a single-gang 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F (0°C and 49°C) from a regulated DC, or full-wave-rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. SpectrAlert Advance outdoor horns, strobes and horn/ strobes shall be listed for outdoor use by UL and shall operate between –40°F and 151°F (–40°C and 66°C). The products shall be listed for use with a System Sensor outdoor/weatherproof backbox with half-inch and threefourths-inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit _______ Listed to UL STD 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at Temporal 3. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisychaining two or more synchronization modules together will synchronize all the zones the modules control. The module shall not operate on a coded power supply. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ Listed to UL STD 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ Listed to UL Standards 1971 and 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 CS-2539 Rev. C page 2 of 4 www.gamewell-fci.com Operating Specifications Standard operating temperature: 32° F to 120° F (0° C to 49° C) K Series operating temperature: -40° F and 151° F (-40° C and 66° C) Humidity range: 10% to 93% non-condensing (indoor products). Strobe flash rate: 1 flash per second. Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC.FWR. Note: Full Wave Recitified (FWR) voltage is a non-regulated, timevarying power source that is used on some power supply and panel outputs. Operating voltage range: 8 V to 17.5 V (12 V nominal); or 16 V to 33 V (24 V nominal). Note: P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 15/75 cd. Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mm2). Ceiling-mount dimensions (including lens): 6.8” diameter x 2.5” deep (17.3 diameter x 6.4 deep cm) Wall-mount dimensions (including lens): Horn dimensions: 5.6” H x 4.7” W x 2.5” D (14.2 H x 11.9 W x 6.4 D cm) 5.6” H x 4.7” W x 1.3” D (14.2 H x 11.9 W x 3.3 D cm) Standard Candela Range 15 15/75 30 75 95 110 115 8 - 17.5 V DC FWR 123 128 142 148 NA NA NA NA NA NA NA NA NA NA 135 150 177 185 8 - 17.5 V NA NA NA NA NA NA NA NA 16 - 33 V 228 207 246 220 281 251 286 258 Horn Current Draw, UL Maximum (mA RMS) Sound Pattern dB Temporal High Temporal Medium Temporal Low Non-temporal High Non-temporal Medium Non-temporal Low Coded High Coded Medium Coded Low 8 - 17.5 V DC FWR 57 55 44 49 38 44 57 56 42 50 41 44 57 55 44 51 40 46 16 - 33 V DC FWR 69 75 58 69 44 48 69 75 60 69 50 50 69 75 56 69 52 50 Horn and Horn/Strobe Rotary Switch Setting) Setting Repetition Rate dB Level 1 Temporal Horn High 2 Temporal horn Medium 3 Temporal horn Low 4 Normal horn Low 5 Normal horn Medium 6 Normal horn Low 7* Externally coded High 8* Externally coded Medium 9* Externally coded Low *NOTE: Settings 7, 8 and 9 are not available on 2-wire horn/strobe Horn and Horn/Strobe Output (dBA) Strobe Current Draw, UL Maximum (mA RMS) Candela High Candela Range 16 - 33 V DC FWR 66 71 77 81 94 96 158 153 181 176 202 195 210 205 Switch Sound 8 - 17.5 V 16 - 33 V Position Pattern dB DC FWR DC FWR 1 Temporal High 78 78 84 84 2 Temporal Medium 74 74 80 80 3 Temporal Low 71 73 76 76 4 Non-temporal High 82 82 88 88 5 Non-temporal Medium 78 78 85 85 6 Non-temporal Low 75 75 81 81 7* Coded High 82 82 88 88 8* Coded Medium 78 78 85 85 9* Coded Low 75 75 81 81 *NOTE: Settings 7, 8, and 9 are not available on 2-wire horn/strobe. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com CS-2539 Rev. C page 3 of 4 Two-Wire Horn/Strobe, STANDARD Candela Range (15 - 115 cd), UL Maximum Current Draw (mA RMS) 8 - 17.5 V Input, Sound Pattern, dB Level 15 15/75 15 15/75 DC Input, Temporal High DC Input, Temporal, Medium DC Input, Temporal, Low DC Input, Non-temporal, High FWR Input, Non-temporal Medium DC Input, Non-temporal, Low FWR Input, Temporal, High FWR Input, Temporal, Medium FWR Input, Temporal, Low FWR Input, Non-temporal, High FWR Input, Non-temporal, Medium FWR Input, Non-temporal, Low 30 16 - 33 V 75 95 110 115 107 97 93 116 102 96 112 103 101 126 110 105 176 157 154 176 163 156 168 160 160 181 166 161 194 182 179 201 187 182 190 184 184 203 189 184 212 201 198 221 207 201 210 202 194 221 208 202 218 210 207 229 216 210 218 206 201 229 216 211 Two-Wire Horn/Strobe, HIGH Candela Range (135 - 185 cd), UL Maximum Current Draw (mA RMS 16 - 33 V 135 150 177 185 FWR Input DC Input 135 16 - 33 V 150 177 185 DC, Temporal High DC, Temporal Medium DC, Temporal Low DC, Non-temporal, High DC, Non-temporal, Medium DC, Non-temporal, Low 215 209 207 233 219 214 231 224 221 248 232 229 265 258 256 281 267 262 245 235 232 255 242 238 137 132 132 141 133 131 136 129 129 142 134 132 259 253 251 270 259 254 290 288 282 303 293 291 147 144 143 152 145 144 155 152 151 161 155 154 297 297 292 309 299 295 79 69 66 91 75 68 88 78 76 103 85 80 90 80 77 100 85 79 97 88 86 112 95 90 FWR, Temporal, High FWR, Temporal, Medium FWR, Temporal, Low FWR, Non-temporal, High FWR, Non-temporal, Medium FWR, Non-temporal, Low 258 250 248 275 262 256 Ordering Information: Model Description Model Description WALL HORNS/STROBES CEILING HORN/STROBES P2R 2-wire horn/strobe, standard cd, red. PC2R 2-wire horn/strobe, standard cd, red. P2RH 2-wire horn/strobe, high cd, red. PC2RH 2-wire horn/strobe, high cd, red. P2RK 2-wire horn/strobe, standard cd, red, outdoor. PC2RK 2-wire horn/strobe, standard cd, red, outdoor. P2RHK 2-wire horn/strobe, high cd, red, outdoor. PC2RHK 2-wire horn/strobe, high cd, red, outdoor. P2W 2-wire horn/strobe, high cd, white. PC2W 2-wire horn/strobe, standard cd, white. P2WH 2-wire horn/strobe, high cd, white. PC2WH 2-wire horn/strobe, high cd, white. P4R 4-wire horn/strobe, standard cd, red. PC4R 4-wire horn/strobe, standard cd, red. P4RH 4-wire horn/strobe, high cd, red. PC4RH 4-wire horn/strobe, high cd, red. P4RK 4-wire horn/strobe, standard PC4RK 4-wire horn/strobe, standard cd, red, outdoor. P4RHK 4-wire horn/strobe, high cd, red, outdoor. PC4RHK 4-wire horn/strobe, high cd, red, outdoor. P4W 4-wire horn/strobe, standard cd, white. PC4W 4-wire horn/strobe, standard cd, white. P4WH 4-wire horn/strobe, high cd, white PC4WH 4-wire horn/strobe, high cd, white. WALL STROBES CEILING STROBES SR Strobe, standard cd, red. SCR Strobe, standard cd, red. SRH Strobe, high cd, red. SCRH Strobe, high cd, red. SRK Strobe, standard cd, red, outdoor. SCRK Strobe, standard cd, red, outdoor. SRHK Strobe, high cd, red, outdoor. SCRHK Strobe, high cd, red, outdoor. SW Strobe, standard cd, white. SCW Strobe, standard cd, white. SWH Strobe, high cd, white. SCHW Strobe, high cd, white. ACCESSORIES HORNS BBS-2 Backbox skirt, wall, red. HR Horn, red. BBSW-2 Backbox skirt, wall, white. HRK Horn, red, outdoor. BBSC-2 Backbox skirt, ceiling, red. HW Horn, white BBSCW-2 Backbox skirt, ceiling, white. NOTE: “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 CS-2539 Rev. C page 4 of 4 www.gamewell-fci.com