Model 3663 - Honeywell Test and Measurement Sensors

Model 3663
Pedal Pressure Load Cell
DESCRIPTION
The pedal pressure sensor mounts directly to the brake pedal
force measurements by the automotive industry, finds many
with its own mounting clamp. Load applied up to 1/2 inch off
production applications. It adapts to any of the pedal or bar
center, produces less than a 0.5% error. Standard capacity
operated devices used in all production facilities.
is 300 lbs. This load cell, which is used for brake pedal
FEATURES
•
50 lb, 100 lb, 200 lb, and 300 lb load capacity
•
Low off-center loading error
•
Easy mounting
•
Rugged load surface
•
Integral cable
•
Compact size
Model 3663
PERFORMANCE SPECIFICATIONS
RANGE CODES
Characteristic
Measure
Range Codes
Range
Load range
50, 100, 200, 300 lb
BN
50 lb
Non-linearity
±0.25 % of rated output
BR
100 lb
Hysteresis
±0.1 % of rated output
CL
200 lb
Repeatability
±0.1 % of rated output
CP
300 lb
Output @ rated capacity
2 mV/V (nominal)
Operation
Tension/compression
Resolution
Infinite
Standard calibration
Tension (+) and compression (-)
MOUNTING DIMENSIONS
1 3/32
2.0 DIA.
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-54 °C to 93 °C [-65 °F to 200 °F]
Temperature, compensated
21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero
±0.003 % of rated output/°F
Temperature effect, output
±0.003 % of reading/°F
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Foil
Excitation (maximum)
20 Vdc or Vac RMS
Insulation resistance
> 5000 mOhm @ 50 Vdc
Bridge resistance (tolerance)
350 ohm
Zero balance
±2.0 %
Electrical termination
PT06W-12-10P
1 5/8
BRAKE PEDAL
PAD
TWO ADJUSTABLE
CLAMPS
FURNISHED
4 CONDUCTOR CABLE-8 FT.
RECEP.
PT06W-12-10P
TYPICAL SYSTEM DIAGRAM
Output
Amplifier
Universal In-Line Amplifiers
+/-5 VDC
UV
+/-10 VDC
UV-10
0 +/-5 VDC
UBP
4-20mA (3 wire)
U3W
4-20mA (2 wire)
U2W
DIN rail Mount In-Line Amplifiers
0 +/- 5 VDC (3 wire)
DV-05
4-20mA (3 wire)
DA-05
0 +/- 10 VDC (3 wire)
DV10
Measure
Static overload capacity
150 % of nominal capacity
Safe overload rating
150 % of nominal capacity
Power Supply
Honeywell
MECHANICAL SPECIFICATIONS
Characteristic
Customer Supplied
Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
In-Line Amplifiers
(Used with unamplified units only)
In-Line Amplifier
Output
Input
Serial Number
Display Units
MODEL 3663
SC500
SC2001
GM
7541
SC1000
SC3004
NK
7558
SC2000
HH
7561-PSD
2003.1 lb.
L1 L2 L3 L4
VALUE
CLEAR
UP
DOWN
SETUP
Mating Connectors & Cables
023-LW181-023-LF Mating Connector
7220-109-XX** Mating connector & 4 conductor cable
** XX represents length in feet
2 Honeywell • Sensing and Control
20ft maximum
CHAN
TARE
ENTER
EXIT
Model 3663
Pedal Pressure Load Cell
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to [email protected]
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008676-1-EN IL50 GLO May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.