Model 53 - Honeywell Test and Measurement Sensors

Model 53
Low Cost Load Cell
DESCRIPTION
Model 53 load cells are bonded foil strain gage transducers
term stability and reliability under severe operating conditions.
designed for cost efficient production and testing applications
The Model 53 compression-only load cell has an integral load
(i.e. press calibration). Engineered compression force
button machined as part of the load cell. The Model 53 must be
measurements up to 50K lb., this model achieves a maximum
mounted on a smooth flat surface for proper operation. Three
non-linearity of 0.5 % full scale. Precision gaging techniques
tapped holes are provided for mounting.
and a stainless steel construction provides excellent long-
FEATURES
•
5 lb to 50K lb
•
Stainless steel
•
Mini footprint
•
Button-style design
•
mV/V output
Model 53
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Load ranges5
5 lb to 50K lb
Linearity (max.)
±0.5 % full scale
Hysteresis (max.)
±0.3 % full scale
Non-repeatability (max.)
±0.1 % full scale
Output (tolerance)
2 mV/V (nominal)
Operation
Compression
Resolution
Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, compensated
15 °C to 71 °C [60 °F to 160 °F]
Temperature effect, zero
±0.005 % full scale/°F
Temperature effect, span
±0.01 % full scale/°F
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Bonded foil
Excitation (calibration)
5 lb to 100 lb
5 Vdc
RANGE CODES
Range
Code
Available ranges Range
Code
Available ranges
AT
5 lb
DN
3000 lb
AV
10 lb
DP
4000 lb
BL
25 lb
DR
5000 lb
BN
50 lb
DT
7500 lb
BR
100 lb
DV
10K lb
CN
250 lb
EJ
15K lb
CR
500 lb
EL
20K lb
CV
1000 lb
EN
30K lb
DL
2000 lb
EP
50K lb
DEFLECTIONS AND RINGING FREQUENCIES
Capacity
(lb)
Deflection @
full scale (in)
Natural ringing frequency
(Hz)
Weight with
cable g [lb]
5
0.001
2000
59 [0.13]
10
0.001
3000
59 [0.13]
25
0.001
16K
62 [0.136]
50
0.001
21K
63 [0.138]
100
0.001
28K
64 [0.141]
250
0.001
25K
72 [0.158]
500
0.001
32K
72 [0.158]
Excitation (calibration)
250 lb to 50K lb
10 Vdc
1000
0.001
42K
75 [0.165]
Insulation resistance
5000 Mohm @ 50 Vdc
2000
0.001
53K
77 [0.17]
Bridge resistance (tolerance)
350 ohm (nominal)
3000
0.001
27K
137 [0.30]
Zero balance (tolerance)
±3 % full scale
4000
0.001
31K
138 [0.304]
Shunt calibration data
Included
5000
0.001
34K
140 [0.306]
Electrical termination (std)
Teflon cable 1.83 m [5 ft]
7500
0.001
41K
142 [0.313]
10K
0.001
47K
145 [0.32]
15K
0.002
24K
368 [0.811]
20K
0.002
28K
372 [0.820]
30K
0.002
33K
377 [0.831]
50K
0.003
24K
1270 [2.8]
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Weight
See table
Material
17-4 PH stainless steel
Maximum allowable load
150 % full scale1
Deflection full scale
See table
Natural frequency
See table
WIRING CODES
Cable
Unamplified
Red
(+) excitation
Black
(-) excitation
Green
(-) output
White
(+) output
2 Honeywell • Sensing and Control
Low Cost Load Cell
MOUNTING DIMENSIONS
Ranges lb
D1 mm [in]
D2 mm [in]
H mm [in]
L mm [in]
A in
B mm [in]
G mm [in]
5, 10, 25, 50, 100
25,4 [1.00]
5,33 [0.21]
15,75 [0.62]
1,27 [0.05]
#4-40 UNC
5,59 [0.22]
19,05 [0.750]
250, 500, 1000, 2000
31,75 [1.25]
8,13 [0.32]
9,91 [0.39]
1,78 [0.07]
#6-32 UNC
6,35 [0.25]
25,4 [1.000]
3000, 4000, 5000,
7500, 10K
38,1 [1.50]
10,16 [0.40]
16,0 [0.63]
2,03 [0.08]
#6-32 UNC
6,35 [0.25]
31,75 [1.250]
15K, 20K, 30K
50,8 [2.00]
15,24 [0.60]
25,4 [1.00]
3,05 [0.12]
#6-32 UNC
6,35 [0.25]
41,28 [1.625]
50K
76,2 [3.00]
19,81 [0.78]
38,1 [1.50]
4,57 [0.18]
#6-32 UNC
6,35 [0.25]
60,33 [2.375]
OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load
ranges
5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 4000,
5000, 7500, 10K, 15K, 20K, 30K, 50K lb
Temperature compensation
1a. 60 °F to 160 °F
1b. 30 °F to 130 °F
1c. 0 °F to 185 °F
1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f. 70 °F to 250 °F
Internal
amplifiers
2u. Unamplified, mV/V output
Electrical
termination
6d. Microtec DR-4S-4H 4-pin
6e. Integral cable: Teflon
6f. Integral cable: PVC
6g. Integral cable: Neoprene
Special
calibration
9a. 10 point (5 up/5 down) 20 % increments @ 68 °F
9b. 20 point (10 up/10 down) 10 % increments @ 68 °F
Shock and
vibration
44a. Shock and vibration resistance
Interfaces
53e. Signature calibration6
53t. TEDS IEEE 1451.4 module4
1g. 70 °F to 325 °F
1h. 70 °F to 400 °F
1i. -65 °F to 250 °F
1j. 0 °C to 50 °C
1k. -20 °C to 85 °C
1m. -25 °C to 110 °C
6h. Integral cable:
Silicone
6i. Integral underwater cable3
6v. Phoenix connector
on end of cable
Honeywell • Sensing and Control
3
Model 53
Low Cost Load Cell
NOTES
1.
Allowable maximum loads – maximum load to be applied without
damage.2
2. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
3. Dimension “H” may increase with option 6i. Consult factory. Maximum temperature is 180 °F.
4. TEDS available with integral cable units only.
5. This unit calibrated to Imperial (non-Metric) units.
6. Signature calibration only available as inline module.
TYPICAL SYSTEM DIAGRAM
In-line amplifiers (used with unamplified units only)
Amplifier
Output
Universal in-line amplifiers
UV
±5 Vdc
UV-10
±10 Vdc
UBP
0 ±5 Vdc
U3W
4 mA to 20 mA (3-wire)
DIN rail mount in-line amplifiers
DV-05
0 ±5 Vdc (3-wire)
DA-05
4 mA to 20 mA (3-wire)
DV-10
0 ±10 Vdc (3-wire)
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
WARNING
PERSONAL INJURY
Customer supplied
Chart recorder
Alarm panel
Data acquisition
Computer
PLC
Model 53
Find out more
Honeywell serves its customers
through a worldwide network of
sales offices, representatives
and distributors. For application
assistance, current specifica-
Display units
SC500
SC2000
SC2001
SC3004
GM
NK
HH
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•The information presented in this datasheet is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
tions, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
http://measurementsensors.
honeywell.com, or e-mail inquiries to [email protected]
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
008638-4-EN IL50 GLO February 2014
Copyright © 2014 Honeywell International Inc. All rights reserved.