Model 123 - Honeywell Test and Measurement Sensors

Model 123
Load Cell
DESCRIPTION
The Model 123 load cell combines both a compact form and
high precision to offer a superior tension force transducer. The
one-piece S-shaped design achieves a maximum non-linearity of
0.03 % full scale for load ranges from 1000 kg to 20000 kg.
FEATURES
•
1000 kg to 20000 kg range
•
±0.03 % accuracy
•
Built-in overload resistance
•
One-piece, nickel-plated alloy steel construction
•
Integral cable
•
Cost efficient
Model 123
PERFORMANCE SPECIFICATIONS
RANGE CODES
Characteristic
Measure
Range codes
Range
Load ranges
1000 kg to 20000 kg
LQ
1000 kg
Accuracy
±0.03 % full scale
LR
1500 kg
Output
2.0 mV/V
LS
2000 kg
Creep (max.)
±0.03 % full scale (30 minutes)
LT
3000 kg
LU
5000 kg
LV
7500 kg
LW
10000 kg
LY
15000 kg
LZ
20000 kg
4
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-30 °C to 70 °C [-22 °F to 158 °F]
Temperature, compensated
-20 °C to 55 °C [-4 °F to 131 °F]
Temperature effect, zero
±0.03 % full scale/10 °C
Temperature effect, span
±0.03 % full scale/10 °C
Protection class
IP673
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Foil
Excitation (acceptable)
10 Vdc to 12 Vdc
Excitation (max.)
15 Vdc
Insulation resistance
> 5000 mOhm
Bridge resistance (tolerance) - Input resistance
400 ohm ±10 ohm (nominal)
Bridge resistance (tolerance) - Output resistance
352 ohm ±2 ohm (nominal)
Zero balance (tolerance)
±1 % full scale
Electrical termination (std)
6 m [19.69 ft] of 5 mm [0.2 in] diameter
cable
MOUNTING DIMENSIONS
Range (kg)
A
B
C
D
1000, 1500
80 mm
[3.15 in]
70 mm
[2.76 in]
25 mm
[0.98 in]
M12 x 1.75
2000, 3000,
5000
108 mm
[4.25 in]
95 mm
[3.75 in]
25 mm
[0.98 in]
M18 x 1.5
7500, 10000
178 mm
[7.00 in]
130 mm
[5.12 in]
51 mm [2.0
in]
M30 x 2
15000, 20000
190 mm
[7.48 in]
160 mm
[6.3 in]
60 mm
[2.36 in]
M39 x 2
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Maximum allowable load
120 % full scale1
Later load limit
100 % full scale
Material
Nickel plated alloy steel
NOTES
WIRING CODES
1.
Cable
Red
(+) supply
Black
(-) supply
Green
(+) output
White
(-) output
Large Black
Shield
2 Honeywell • Sensing and Control
2.
3.
4.
Allowable maximum loads – maximum load to be applied without
damage.2 Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
IP68 rating for load ranges 7500 kg and greater.
This unit is calibrated to Metric (non-Imperial) units.
Model 123
Load Cell
TYPICAL SYSTEM DIAGRAM
In-line amplifiers (used with unamplified units only)
Amplifier
Output
Universal in-line amplifiers
UV
±5 Vdc
UV-10
±10 Vdc
UBP
0 ±5 Vdc
U3W
4 mA to 20 mA (3-wire)
DIN rail mount in-line amplifiers
DV-05
0 ±5 Vdc (3-wire)
DA-05
4 mA to 20 mA (3-wire)
DV-10
0 ±10 Vdc (3-wire)
Customer supplied
Chart recorder
Alarm panel
Data acquisition
Computer
PLC
Model 123
Display units
SC500
SC2000
SC2001
SC3004
GM
NK
HH
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
Find out more
Honeywell serves its customers
through a worldwide network of
sales offices, representatives
and distributors. For application
assistance, current specifica-
•The information presented in this datasheet is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
tions, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit http://measurementsensors.
honeywell.com, or e-mail inquiries to [email protected]
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com
008663-2-EN IL50 GLO September 2011
Copyright © 2011 Honeywell International Inc. All rights reserved.