Model 355 Flush Diaphragm Pressure Transducer DESCRIPTION Subminiature Model 355 gage pressure transducer is a rugged, ly amplified Model 355 accepts input voltage from 9 Vdc to 32 one-piece, stainless steel unit which features a flush diaphragm Vdc and delivers a high level 4 mA to 20 mA or 0 V to 5 V output. design, making it ideal for operations which involve the spraying The Model 355 is all welded and hermetically sealed for reliable or application of sealants, paints, coatings or other congealable performance in corrosive environments. media which can clog conventional pressure ports. The internal- FEATURES • 0 psig to 500 psig to 0 psig to 5000 psig • Flush diaphragm • High level output • No dead volume • ±0.50 % accuracy • Intrinsically safe available (2N option only)9 • CE approved10 Model 355 PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Pressure ranges 0 psig - 500 psig to 0 psig - 5000 psig CR 500 psi Accuracy ±0.50 %7 CT 750 psi Non-linearity 0.5 % CV 1000 psi Non-repeatability 0.1 % DJ 1500 psi Output 4 mA to 20 mA (std) Infinite DL 2000 psi Resolution DM 2500 psi DN 3000 psi DR 5000 psi ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -29 °C to 85 °C [-20 °F to 185 °F] Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F] Temperature effect, zero 0.01 % full scale/°F Temperature effect, span 0.02 % reading/°F ELECTRICAL SPECIFICATIONS Characteristic Measure Excitation (calibration) 4 mA to 20 mA, two wire (std.) 9 Vdc to 32 Vdc 0 Vdc to 5 Vdc, three wire (opt. 2c) 9 Vdc to 28 Vdc Insulation resistance 50 mOhm @ 50 V Electrical termination (std) PTIH-10-6P Mating connector (not incl.) PT06A-10-6S (AA111) MECHANICAL SPECIFICATIONS Characteristic Measure Media Gases, liquids compatible with 17-4 PH SS Overload, safe 300 % over capacity Overload, burst 500 % over capacity or 20000 psi, whichever is less Pressure port 7/16-20 UNF Wetted parts material 17-4 PH stainless steel Case material Stainless steel OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Pressure ranges 500, 750, 1000, 1500, 2000, 2500, 3000, 5000 psi Temperature compensation 1a. 60 °F to 160 °F 1b. 30 °F to 130 °F 1c. 0 °F to 185 °F Internal amplifiers 2k. 4 mA to 20 mA, two-wire output 2c. 0 Vdc to 5 Vdc 2n. (2N) 4 mA to 20 mA (two wire output), intrinsically safe Pressure ports 5p. M12 x 15 male 5d. 7/16 -20 UNF male Electrical termination 6a. Bendix PTIH-10-6P (orequivalent) 6 pin (max 250 °F) 6e. Integral cable: Teflon (-54 °C to 245 °C) 6f. Integral cable: PVC (-30 °C to 70 °C) 6h. Integral cable: Silicone (-54 °C to 150 °C) Special calibration 9e. CE mark 9a. 10 point (5 up/5 down) 20 % increments @ 20 °C 9b. 20 point (10 up/10 down) 10 % increments @ 20 °C Interfaces 53e. Signature calibration 53t. TEDS IEEE 1451.4 module8 1d. -20 °F to 130 °F 1j. 0 °C to 50 °C 1k. -20 °C to 85 °C 6i. Integral underwater cable, 8m (max 80 °C) 6n. DIN 40050 6q. Molded integral cable: Polyurethane 6v. Phoenix connector on end of cable SPECIAL REQUIREMENTS (CONSULT FACTORY) 2 Honeywell • Sensing and Control Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling +1 614-850-5000 (800-848-6564). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Flush Diaphragm Pressure Transducer INTERNAL AMPLIFIERS Amplifier specifications Vehicle voltage output: Option 2c Current two-wire: Option 2k Intrinsically safe amp: Option 2N (2n)*** Output signal 0 Vdc to 5 Vdc @ 45 mA 4 mA to 20 mA 4 mA to 20 mA Input power (voltage) 11 Vdc to 28 Vdc 9 Vdc to 28 Vdc 9 Vdc to 28 Vdc3 Input power (current) 40 mA 4 mA to 28 mA 4 mA to 24 mA Frequency response 3000 Hz 300 Hz 2000 Hz Power supply rejection 60 db 60 db 60 db Operating temperature -20 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F Reverse voltage protection Yes Yes Yes Short circuit protection Momentary Yes Yes Wiring code: connector A B C D E F A B C D E F A B C D E F Wiring code: cable3,5,6 R (+) Supply Bl Output com* G Supply ret.* W (+) Output B No connection Br No connection (+) Supply Output com.** Supply ret.** (+) Output No connection No connection 3 (+) Supply No connection No connection (+) Output Case ground No connection R (+) Supply Bl (+) Output W Case ground (+) Supply No connection No connection (+) Output Case ground No connection R (+) Supply Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00. INSTALLATION AND MOUNTING MOUNTING DIMENSIONS AND CHARACTERISTICS The Model 355 has straight threads and uses a #12 O-ring for pressure sealing. To get the best seal with the O-ring on the transducer, the tapped hole should have the dimensions shown here. For normal operating temperatures [-65 °F to 250 °F] use the BUNA-N (black) O-rings. For high temperatures [250 °F to 425 °F] use silicone rubber (red). Maximum torque is 50 in.-lb., 17-4 PH stainless steel only. For reference only TYPICAL SYSTEM DIAGRAM Customer supplied Chart recorder Alarm panel Data acquisition Computer PLC Model 355 Mating connectors & cables PT06A-10-6S (4 conductor cable), std. PT06E-10-6S (4 conductor cable) Display units SC500 SC2000 SC2001 SC3004 GM-A Honeywell • Sensing and Control 3 Model 355 Flush Diaphragm Pressure Transducer NOTES 1. Gage pressure units greater than 500 psi are sealed at atmospheric pressure. 2. Input power (voltage) for internal amplifier options 2j, 2k, 2n (2N) depends on load resistance. 3. Interconnecting shunt cal. 1 with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 mA to 20 mA, three wire units), or 80 % (voltage amp. units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2a, 2b, 2c, 2t and 2j. 4. Not available with temperatures below -29 °C [-20 °F] or above 85 °C [185 °F]. 5. G=Green; B=Blue; W=White; Bl=Black; Br=Brown; Y=Yellow; R=Red; O=Orange. Color specifying cable and number or letter specifying connector. 6. No mating connector necessary with cable option. 7. Accuracies stated are expected for best-fit straight line for all errors including linearity, hysteresis & non-repeatability thru zero. 8. Consult factory for TEDS availability with amplified models. 9. Range dependent; consult factory. Termination dependent; consult factory. 10.CE approved only with 2N option. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Find out more WARNING Honeywell serves its customers MISUSE OF DOCUMENTATION through a worldwide network of •The information presented in this datasheet is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. Failure to comply with these instructions could result in death or serious injury. To learn more about Honeywell’s test and measurement products, call +1-614-850-5000, visit http://measurementsensors. honeywell.com, or e-mail inquiries to [email protected] Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA sensing.honeywell.com 008679-2-EN IL50 GLO May 2014 Copyright © 2014 Honeywell International Inc. All rights reserved.