Model 3130-131 - Honeywell Test and Measurement Sensors

Model 3130-131
Tension/Compression Canister Load Cell
DESCRIPTION
The Model 3130-131 fatigue-resistant load cells are extremely
minimizing the primary cause of load cell failure. Dual bridge
resistant to extraneous bending and side loading forces. The
option available for feedback control and redundancy.
structure virtually eliminates bending strains at the strain gage,
FEATURES
•
Optional dual bridge (not shown)
•
Metric threads
•
Resist fatigue failure
•
Multi-beam structure design
•
Capacities to 5000000 N
•
Bending moment resistance up to 6110000 lb inches
•
Up to 180000 lb of shear resistance
•
Flexible mounting configurations
Model 3130-131
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Load range
2M, 3.5M, 5M N
Non-linearity
±0.2 % of rated output
Hysteresis
±0.2 % of rated output
Repeatability
±0.05 % of rated output
Output @ rated capacity
±2 mV/V (nominal)
Operation
Tension/compression
Resolution
Infinite
Standard calibration
Tension (+) and compression (-)
1
TYPICAL SYSTEM DIAGRAM
Output
Amplifier
Universal In-Line Amplifiers
+/-5 VDC
UV
+/-10 VDC
UV-10
0 +/-5 VDC
UBP
4-20mA (3 wire)
U3W
4-20mA (2 wire)
U2W
DIN rail Mount In-Line Amplifiers
0 +/- 5 VDC (3 wire)
DV-05
4-20mA (3 wire)
DA-05
0 +/- 10 VDC (3 wire)
DV10
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-54 °C to 93 °C [-65 °F to 200 °F]
Temperature, compensated
21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero
±0.003 % of rated output/°F
Temperature effect, output
±0.003 % of reading/°F
Customer Supplied
Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
In-Line Amplifiers
(Used with unamplified units only)
Power Supply
Honeywell
In-Line Amplifier
Output
Input
Serial Number
Display Units
MODEL 3130
SC500
SC2001
GM
7541
SC1000
SC3004
NK
7558
SC2000
HH
7561-PSD
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Strain gage type
Foil
Excitation (maximum)
20 Vdc or Vac RMS
Insulation resistance
> 5000 mOhm @ 50 Vdc
Bridge resistance
(tolerance)
700 ohm
Number of bridges
1 or 2
Zero balance
±1.0 %
Electrical termination
MS-3102E-14S-5P
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Static overload capacity
150 % of nominal capacity
Material
Carbon steel
Fatigue life (0 to full fatigue
load)
100 x 106 cycles
Fatigue life (full fatigue tension to compression)
50 x 106 cycles
Natural frequency
See table
WIRING CODES
Wire
Red
(+) excitation
Black
(-) excitation
Green
(+) output
White
(-) output
2 Honeywell • Sensing and Control
2003.1 lb.
L1 L2 L3 L4
OR
VALUE
CLEAR
UP
DOWN
SETUP
CHAN
TARE
ENTER
EXIT
Mating Connectors & Cables
064-LW13621 Mating connector
7200-76-XX* Mating connector and six conductor cable
(unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable
(unamplified sensor without sense leads)
7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable
for connection to 7541
7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable
for connection to 7541
* XX represents length in feet
** XX represents length in feet
100ft maximum
20ft maximum
Tension/Compression Canister Load Cell
NATURAL FREQUENCY
Nominal load limit
capacity Fz
Static extraneous load limits
lb
N
Static
overload
capacity (%
of nominal
capacity)
Fatigue
capacity (%
of nominal
capacity)
Shear FX or
FY (lb)
Bending MX
or MY (lb-in)
Torque MZ
(lb-in)
Deflection
at nominal
load limit
(in)
Ringing
frequency
(Hz)
500K
2M
150
50
94K
4530K
820K
0.006
2500
800K
3.5M
150
50
180K
5450K
1050K
0.006
3100
1000K
5M
150
50
180K
6110K
1100K
0.006
3600
MOUNTING DIMENSIONS
Model
A cm [in]
B cm [in]
C cm [in]
D cm [in]
E cm [in]
F cm [in]
G cm [in]
3130
31,75 [12.50]
3,81 [1.50]
17,78 [7.0]
5,08 [2.0]
1,91 [0.75]
32,29 [12.75]
31,12 [12.25]
H cm [in]
J cm [in]
K cm [in]
L cm [in]
M cm [in]
N cm [in]
P cm [in]
*Q cm [in]
*R cm [in]
15,88 [6.25]
13,34 [5.25]
2,54 [1.0]
19,86 [7.82]
6,35 [2.50]
24,15 [9.50]
8,89 [3.50]
M42-3 [1.75-12]
M125-4 [5-8]
* 3130-131 • Q and R are metric thread measures
* 3130 standard • Q and R are English thread measures
R THD.
P DEEP
BOTH ENDS
1.0
J DIA.
BOTH ENDS
3/8 16 THD. 5/8 DEEP
2 HOLES AT 180 LIFTING
E
D
H
B
C
L
Q THD. 2.0 DEEP
8 HOLES EQUALLY SPACED
ON N DIA. BOTH ENDS
M
RECEP.
MS-3102E-14S-5P
G DIA. BOTH ENDS
F DIA.
A
SPANNER WRENCH HOLES
13/32 DIA. 3/8 DEEP 4 HOLES
EQUALLY SPACED BOTH ENDS
Honeywell • Sensing and Control 3
Model 3130-131
Tension/Compression Canister Load Cell
NOTES
1.This unit calibrated to Imperial (non-Metric) units.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to [email protected]
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008644-1-EN IL50 GLO May 2008