Specification AXIS50 Oscillator type: Low Phase Noise VHF

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 1
AXIS50
Low Phase Noise VHF/UHF VCXO (no PLL)
with LVPECL or Sine Wave Output
Parameter
min.
max.
Unit
Frequency range
Standard frequencies
60
400
60 / 93.333 / 182 / 186.667
213.3 / 311.040 / 400.000
MHz
MHz
Frequency stability
Initial tolerance
vs. operating temperature range
vs. supply voltage variation
vs. load change
Long term (aging) per year
Long term (aging) over 10 years
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Output level (Option 1 = “S”)
Harmonics (Option 1 = “S”)
Sub-harmonics (Note 5)
Output Levels (Option 1 = “L”)
HIGH (VOH)
LOW (VOL)
Supply voltage VS
Current consumption (steady state)
Operating temperature range
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
4.
5.
6.
7.
typ.
±15
0.15
±5
±10
±0.1
±0.1
±2
±10
ppm
ppm
ppm
ppm
ppm
ppm
ppm
3.15
ppm
V
Date: 2014-04-05
Condition
(Note 2)
VS ±5%
Load ±5%
@ 40°C
@ 40°C
(Note 3)
positive
100
kΩ
Sine Wave
LVPECL Complementary
0
-30
-40
2.215
1.470
3.15
4.75
2.345
1.595
3.3
5.0
-20
2.420
1.745
3.45
5.25
40
+70
20.5x20.5x12.5 max.
8
Palette
dBm
dBc
dBc
Option 1 = “S”
Option 1 = “L”
RL = 50 Ω (Note 4)
V
V
V
V
mA
°C
RL = 50 Ω to VS - 2 V
(Note 6)
Option 2 = “33”
Option 2 = “50”
(Note 7)
mm
g
IEC 60679-3 CO 41
IEC 60286-3
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Other stabilities over temperature on request
Wider tuning range on request
Higher output level on request
For frequencies above 100 MHz sub-harmonics may be present. Please consult factory
Output levels vary 1:1 with VS
Current consumption depends on frequency, supply voltage and output option
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIS50 Rev.1
Drawing D0
Page 1(3)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-55
VS + 10%
15
+125
Unit
Condition
V
V
°C
VS to GND
VC to GND
Ordering Code
Option 1
Option 2
[RF output]
[Supply Voltage]
AXIS50
S or L
50
Example: AXIS50-S-50_Rev.1 – 350.000 MHz
Model
Revision
Frequency [MHz]
Rev.1
350.000
Enclosure drawing
Pin connections:
Pin #
1
2
3
4
5
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIS50 Rev.1
Drawing D0
Page 2(3)
Symbol
N.C.
Q
RF OUT
GND
VC
VS
Function
No Connection (Option S)
RF Output ( Q ) (Option L)
RF Output (Q)
Ground
Control Voltage (EFC)
Supply Voltage
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Handling and Testing
Parameter
Procedure
Handling and Testing
Processing
Source
Application Note AXAN-011
Application Note AXAN-012
Parameter
Procedure
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS compliant
IEC60749-26
IEC60749-27
Yes
Yes
www.axtal.com
www.axtal.com
Condition
HBM
MM
No
No
2000 V
200 V
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
1
D0
05.04.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
First issue – Replaces AXIS50-11
AXIS50 Rev.1
Drawing D0
Page 3(3)
Author
Checked
HH
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]