Designed and Manufactured in Germany Specification Oscillator type: Rev.: 3 Date: 2015-02-17 AXIOM210 Ultra-Low Phase Noise OCXO in Vibration-isolated Package Parameter Frequency range Standard frequencies Frequency stability Initial tolerance @+25°C vs. operating temperature range vs. supply voltage variation (pushing) Long term (aging) per day Long term (aging) per year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load RL Output level Harmonics Spurious at rest Phase noise at rest Phase noise under random vibration Warm-up time @ +25°C Supply voltage VS Current consumption (steady state) Current consumption (warm-up) Operating temperature range Enclosure (see drawings) (LxWxH) Weight Notes: 1. 2. 3. 4. min. typ. max. Unit 50 130 100.000 / 120.000 MHz MHz ±300 ±200 ±10 ±2 ±100 ppb ppb ppb ppb ppb 9 ppm V ±100 ±1 1 ±2 5 Positive 100 Condition @ VC = 5V steady state (Note 2) VS ±5% after 30 days operation after 30 days operation kΩ Sine wave 50 +7 -40 -30 -90 Ω dBm dBc dBc See table 1 See table 2 5 12.6 300 500 +85 min V mA mA °C 50.0x50.0x30.0 max. 200 mm g 11.4 12.0 -40 ±5% Option 2 Option 3 ∆ffinal/f0 < ±0.1 ppm (Note 3) @ +25°C (Note 2) Option 1 “H” or “S” (Note 4) Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Other stability and temperature range on request Other supply voltage on request Other enclosure height on request. Please consult factory Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -55 VS + 10% 15 +125 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM210 Rev.3 Drawing D0 Page 1(6) Unit Condition V V °C VS to GND VC to GND www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Phase Noise – Option 2: Offset 10 Hz 100 Hz 1 kHz 10 kHz ≥100 kHz Table 1 A -90 -125 -155 -165 -175 B -95 -130 -158 -168 -175 100 MHz C -97 -132 -160 -170 -175 D -100 -135 -162 -172 -175 E -105 -137 -164 -174 -175 A -85 -118 -148 -160 -175 B -90 -122 -150 -165 -175 120 MHz C -95 -125 -153 -168 -175 D -97 -127 -155 -170 -175 E -100 -130 -157 -172 -175 Unit dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz Vibration sensitivity – Option 3: Option Phase noise @ 1 kHz * 140 145 150 155 Table 2 Unit -140 dBc/Hz -145 dBc/Hz -150 dBc/Hz -155 dBc/Hz * see vibration profile below Vibration profile PSD = 0.02 g²/Hz according to RTCA/DO160E Curve C Functional test: 1 hour each direction Endurance test: 3 hours each direction at 2 times the PSD level of the functional test Notes: - Other vibration profiles on request (max. PSD = 0.04 g²/Hz for fVIBRATION < 15 Hz) - Available enclosure height depends on vibration profile Ordering Code Option 1 Option 2 Option 3 Revision [Package] [Phase noise] [Vibration sensitivity] AXIOM210 “H” or “S” Table 1 Table 2 Rev.3 Example: AXIOM210H-A-140_Rev.3 – 100.000 MHz Model GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM210 Rev.3 Drawing D0 Page 2(6) Frequency [MHz] 100.000 www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Phase noise response under random vibration at 100 MHz Typical phase noise response for vibration sensitivity option “155” Vibration orientation Handling and Testing Parameter Handling and Testing Processing Parameter Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS- Compliant GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Procedure Application Note AXAN-011 Application Note AXAN-012 Procedure IEC60749-26 IEC60749-27 Yes Yes AXIOM210 Rev.3 Drawing D0 Page 3(6) HBM MM No No Source www.axtal.com www.axtal.com Condition 2000 V 200 V www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Enclosure drawings Package Option H “Threaded Holes” Pin connections: Pin # Symbol 1 VS 2 GND 3 VC SMA RF OUT GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM210 Rev.3 Drawing D0 Page 4(6) Function Supply Voltage Ground Control Voltage (EFC) RF Output www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Package Option S “Threaded Studs” Pin connections: Pin # Symbol 1 VS 2 GND 3 VC SMA RF OUT GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM210 Rev.3 Drawing D0 Page 5(6) Function Supply Voltage Ground Control Voltage (EFC) RF Output www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] 1 2 D0 D0 25.11.2013 17.07.2014 3 D0 17.02.2015 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks First issue New enclosure drawing with changed package height, various parameters and environmental conditions updated, editorial changes Package options added (replaces AXIOM200) AXIOM210 Rev.3 Drawing D0 Page 6(6) Author Checked HH HH BN HH HH HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]