Low Phase Noise OCXO in Vibration-isolated Package
Parameter
Frequency range
Nominal frequencies
Frequency stability
Initial tolerance @ +25°C
vs. operating temperature range
vs. supply voltage variation (pushing)
vs. load change (pulling)
Long term (aging) per day
st
Long term (aging) 1 year
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load RL
Output level
Harmonics
Spurious
Warm-up time @+25°C
Phase noise under rest @ 100 MHz
(Note 2)
Phase noise under random vibration
G-sensitivity (Note 4)
Supply voltage VS
Current consumption (steady state)
Current consumption (warm-up)
Operating temperature range
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
4.
min.
60
typ.
max.
125
100.000/120.000
MHz
MHz
±300
±300
±20
±20
±2
±200
ppb
ppb
ppb
ppb
ppb
ppb
10
ppm
V
±1
0
5
Positive
100
+10
11.4
Condition
@ VC = 5V
VS ±5%
RL ±10%
after 30 days operation
after 30 days operation
kΩ
Sine wave
50
-20
Unit
-30
-90
10
-100
-130
-155
-160
-165
Consult factory
0.1
12.0
12.6
400
800
+70
50x48x27
60
Ω
dBm
dBc
dBc
min
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
ppb/g
V
mA
mA
°C
±10%
∆ffinal/f0 < ±0.1 ppm
@ 10 Hz
@ 100 Hz
@ 1 kHz
@ 10 kHz
@ ≥100 kHz
(Note 3)
per axis
@ +25°C
mm
g
Palette
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Better phase noise on request
Phase noise under random vibration depends on the vibration profile and level. Please consult factory
Overall G-sensitivity is a function of vibration frequency. Roll-off above 200 Hz.
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM260 Rev.3
Drawing D0
Page 1(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Storage Temperature
-0.5
-55
VS + 10%
+125
Unit
Condition
V
°C
VS to GND
Ordering Code
Model
Revision
Frequency [MHz]
AXIOM260 Rev.3
100.000
Example: AXIOM260_Rev.3 – 100.000 MHz
Handling and Testing
Parameter
Procedure
Handling and Testing
Processing
Source
Application Note AXAN-011
Application Note AXAN-012
Parameter
Procedure
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS- Compliant
IEC60749-26
IEC60749-27
Yes
Yes
www.axtal.com
www.axtal.com
Condition
HBM
MM
No
No
2000 V
200 V
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM260 Rev.3
Drawing D0
Page 2(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Enclosure drawing
Pin connections
Pin #
1
2
3
4
Symbol
RF OUT
GND
VC
VS
Function
RF Output
Ground
Control Voltage (EFC)
Supply Voltage
* See Application Note AXAN-011
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM260 Rev.3
Drawing D0
Page 3(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
2
3
D0
D0
01.10.2012
26.04.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
Major revision with screening option, editorial changes
Frequency range added, various parameters updated,
environmental conditions updated, editorial changes
AXIOM260 Rev.3
Drawing D0
Page 4(4)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834