Designed and Manufactured in Germany Specification Oscillator type: Rev.: 3 Date: 2014-04-26 AXIOM260 Low Phase Noise OCXO in Vibration-isolated Package Parameter Frequency range Nominal frequencies Frequency stability Initial tolerance @ +25°C vs. operating temperature range vs. supply voltage variation (pushing) vs. load change (pulling) Long term (aging) per day st Long term (aging) 1 year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load RL Output level Harmonics Spurious Warm-up time @+25°C Phase noise under rest @ 100 MHz (Note 2) Phase noise under random vibration G-sensitivity (Note 4) Supply voltage VS Current consumption (steady state) Current consumption (warm-up) Operating temperature range Enclosure (see drawing) (LxWxH) Weight Packing Notes: 1. 2. 3. 4. min. 60 typ. max. 125 100.000/120.000 MHz MHz ±300 ±300 ±20 ±20 ±2 ±200 ppb ppb ppb ppb ppb ppb 10 ppm V ±1 0 5 Positive 100 +10 11.4 Condition @ VC = 5V VS ±5% RL ±10% after 30 days operation after 30 days operation kΩ Sine wave 50 -20 Unit -30 -90 10 -100 -130 -155 -160 -165 Consult factory 0.1 12.0 12.6 400 800 +70 50x48x27 60 Ω dBm dBc dBc min dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz ppb/g V mA mA °C ±10% ∆ffinal/f0 < ±0.1 ppm @ 10 Hz @ 100 Hz @ 1 kHz @ 10 kHz @ ≥100 kHz (Note 3) per axis @ +25°C mm g Palette Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Better phase noise on request Phase noise under random vibration depends on the vibration profile and level. Please consult factory Overall G-sensitivity is a function of vibration frequency. Roll-off above 200 Hz. GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM260 Rev.3 Drawing D0 Page 1(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Storage Temperature -0.5 -55 VS + 10% +125 Unit Condition V °C VS to GND Ordering Code Model Revision Frequency [MHz] AXIOM260 Rev.3 100.000 Example: AXIOM260_Rev.3 – 100.000 MHz Handling and Testing Parameter Procedure Handling and Testing Processing Source Application Note AXAN-011 Application Note AXAN-012 Parameter Procedure Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS- Compliant IEC60749-26 IEC60749-27 Yes Yes www.axtal.com www.axtal.com Condition HBM MM No No 2000 V 200 V Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM260 Rev.3 Drawing D0 Page 2(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Enclosure drawing Pin connections Pin # 1 2 3 4 Symbol RF OUT GND VC VS Function RF Output Ground Control Voltage (EFC) Supply Voltage * See Application Note AXAN-011 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM260 Rev.3 Drawing D0 Page 3(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Revision History Rev. Drawing Date [dd.mm.yyyy] 2 3 D0 D0 01.10.2012 26.04.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Major revision with screening option, editorial changes Frequency range added, various parameters updated, environmental conditions updated, editorial changes AXIOM260 Rev.3 Drawing D0 Page 4(4) Author Checked BN HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]