Designed and Manufactured in Germany Specification Oscillator type: Rev.: 3 Date: 2014-05-08 AXIOM75ULN Ultra-Low Phase Noise OCXO with Sine Wave Output Parameter Frequency Range Standard frequencies Frequency stability Initial tolerance @ +25°C vs. operating temperature range vs. supply voltage variation (pushing) vs. load change (pulling) Long term (aging) per day st Long term (aging) 1 year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load RL Output level (Note 2) Harmonics Spurious Warm-up time Phase noise @ 100 MHz and 120 MHz G-Sensitivity Reference voltage VREF output (Note 3) Supply voltage VS (Note 3) Current consumption (steady state) Current consumption (warm-up) Enclosure (see drawing) (LxWxH) Weight Packing Notes: 1. 2. 3. 4. min. 80 typ. max. Unit Condition 125 100.000/120.000 MHz MHz ±300 Option 2 & 3 See tables 2 & 3 ±10 ±5 ±1 ±2 ±100 ±200 ppb VC @ VREF/2 steady state ppb ppb ppb ppb VS ±5% RL ±5% after 30 days operation after 30 days operation ±1 0 ±2 VREF/2 Positive VREF 100 kΩ Sine wave 50 Ω dBm dBc dBc min +7 3 See table 1 -30 -90 5 1.0 11.4 ppm V 10.0 12.0 ppb/g V V mA mA 12.6 150 350 25.8x25.8x12.7 max. 20 Palette mm g ±5% ∆ffinal/f0 < ±0.1 ppm Option 1 per axis @ +25°C (Note 4) (Note 4) IEC 60679-3 CO 43 Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Other output level on request Other supply and reference voltage on request May be higher for wide operating temperature range Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -55 VS + 10% 15 +125 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM75ULN Rev.3 Drawing D0 Page 1(4) Unit Condition V V °C VS to GND VC to GND www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Phase Noise – Option 1: Offset 10 Hz 100 Hz 1 kHz 10 kHz ≥100 kHz Table 1 A -90 -125 -155 -165 -175 B -95 -130 -158 -168 -175 100 MHz C -97 -132 -160 -170 -175 D -100 -135 -162 -172 -175 E -105 -137 -164 -174 -175 A -85 -118 -148 -160 -175 B -90 -122 -150 -165 -175 120 MHz C -95 -125 -153 -168 -175 D -97 -127 -155 -170 -175 E -100 -130 -157 -172 -175 Unit dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz Frequency stability vs. temperature Option 2 05 10 25 50 100 200 Table 2 Stability [ppb] ±5 ±10 ±25 ±50 ±100 ±200 Temperature range [°C] 05 0 ~ +50 O -10 ~ +60 O -20 ~ +70 O -30 ~ +70 O -40 ~ +75 -40 ~ +85 -55 ~ +85 Table 4 “Availability” Lower Temperature Option 3 T [°C] 0 0 1 -10 2 -20 3 -30 4 -40 5 -55 Table 3 10 X X X O O - Upper Temperature Option 3 T [°C] A +50 B +60 C +70 D +75 E +80 F +85 Standard: “1B” = -10°C to +60°C Frequency stability [Option 2] 25 50 100 X X X X X X X X X X X X X X X O X X O X X 200 X X X X X X X X = available, O = available on request, - not available Ordering Code Option 1 Option 2 Option 3 [Phase noise] [Stability] [Temperature range] AXIOM75ULN Table 1 Table 2 Table 3 Example: AXIOM75ULN-C-25-1B_Rev.3 – 100.000 MHz Model GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM75ULN Rev.3 Drawing D0 Page 2(4) Revision Frequency [MHz] Rev.3 100.000 www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Enclosure drawing Pin connections Pin # 1 2 3 4 5 Symbol RF OUT GND VC VREF VS Function RF Output Ground Control Voltage (EFC) Reference Voltage Supply Voltage * See Application Note AXAN-011 Handling and Testing Parameter Handling and Testing Processing Parameter Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS- Compliant GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Procedure Application Note AXAN-011 Application Note AXAN-012 Procedure IEC60749-26 IEC60749-27 Yes Yes AXIOM75ULN Rev.3 Drawing D0 Page 3(4) HBM MM No No Source www.axtal.com www.axtal.com Condition 2000 V 200 V www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] 2 3 D1 D0 27.12.2013 08.05.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Operating temperature range ordering code added Various parameters updated, G-Sensitivity added, environmental conditions updated, editorial changes AXIOM75ULN Rev.3 Drawing D0 Page 4(4) Author Checked BN HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]