Parameter
Frequency Range
Standard frequencies
Frequency stability
Initial tolerance @ +25°C
vs. operating temperature range
vs. supply voltage variation (pushing)
vs. load change (pulling)
Long term (aging) per day
st
Long term (aging) 1 year
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load RL
Output level (Note 2)
Harmonics
Spurious
Warm-up time
Phase noise @ 100 MHz and 120 MHz
G-Sensitivity
Reference voltage VREF output (Note 3)
Supply voltage VS (Note 3)
Current consumption (steady state)
Current consumption (warm-up)
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
4.
min.
80
typ.
max.
Unit
Condition
125
100.000/120.000
MHz
MHz
±300
Option 2 & 3
See tables 2 & 3
±10
±5
±1
±2
±100
±200
ppb
VC @ VREF/2
steady state
ppb
ppb
ppb
ppb
VS ±5%
RL ±5%
after 30 days operation
after 30 days operation
±1
0
±2
VREF/2
Positive
VREF
100
kΩ
Sine wave
50
Ω
dBm
dBc
dBc
min
+7
3
See table 1
-30
-90
5
1.0
11.4
ppm
V
10.0
12.0
ppb/g
V
V
mA
mA
12.6
150
350
25.8x25.8x12.7 max.
20
Palette
mm
g
±5%
∆ffinal/f0 < ±0.1 ppm
Option 1
per axis
@ +25°C (Note 4)
(Note 4)
IEC 60679-3 CO 43
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Other output level on request
Other supply and reference voltage on request
May be higher for wide operating temperature range
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-55
VS + 10%
15
+125
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM75ULN Rev.3
Drawing D0
Page 1(4)
Unit
Condition
V
V
°C
VS to GND
VC to GND
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Phase Noise – Option 1:
Offset
10 Hz
100 Hz
1 kHz
10 kHz
≥100 kHz
Table 1
A
-90
-125
-155
-165
-175
B
-95
-130
-158
-168
-175
100 MHz
C
-97
-132
-160
-170
-175
D
-100
-135
-162
-172
-175
E
-105
-137
-164
-174
-175
A
-85
-118
-148
-160
-175
B
-90
-122
-150
-165
-175
120 MHz
C
-95
-125
-153
-168
-175
D
-97
-127
-155
-170
-175
E
-100
-130
-157
-172
-175
Unit
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Frequency stability vs. temperature
Option 2
05
10
25
50
100
200
Table 2
Stability
[ppb]
±5
±10
±25
±50
±100
±200
Temperature
range [°C]
05
0 ~ +50
O
-10 ~ +60
O
-20 ~ +70
O
-30 ~ +70
O
-40 ~ +75
-40 ~ +85
-55 ~ +85
Table 4 “Availability”
Lower Temperature
Option 3
T [°C]
0
0
1
-10
2
-20
3
-30
4
-40
5
-55
Table 3
10
X
X
X
O
O
-
Upper Temperature
Option 3
T [°C]
A
+50
B
+60
C
+70
D
+75
E
+80
F
+85
Standard: “1B” = -10°C to +60°C
Frequency stability [Option 2]
25
50
100
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O
X
X
O
X
X
200
X
X
X
X
X
X
X
X = available, O = available on request, - not available
Ordering Code
Option 1
Option 2
Option 3
[Phase noise]
[Stability]
[Temperature range]
AXIOM75ULN
Table 1
Table 2
Table 3
Example: AXIOM75ULN-C-25-1B_Rev.3 – 100.000 MHz
Model
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM75ULN Rev.3
Drawing D0
Page 2(4)
Revision
Frequency [MHz]
Rev.3
100.000
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Enclosure drawing
Pin connections
Pin #
1
2
3
4
5
Symbol
RF OUT
GND
VC
VREF
VS
Function
RF Output
Ground
Control Voltage (EFC)
Reference Voltage
Supply Voltage
* See Application Note AXAN-011
Handling and Testing
Parameter
Handling and Testing
Processing
Parameter
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS- Compliant
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Procedure
Application Note AXAN-011
Application Note AXAN-012
Procedure
IEC60749-26
IEC60749-27
Yes
Yes
AXIOM75ULN Rev.3
Drawing D0
Page 3(4)
HBM
MM
No
No
Source
www.axtal.com
www.axtal.com
Condition
2000 V
200 V
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
2
3
D1
D0
27.12.2013
08.05.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
Operating temperature range ordering code added
Various parameters updated, G-Sensitivity added,
environmental conditions updated, editorial changes
AXIOM75ULN Rev.3
Drawing D0
Page 4(4)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]