H HiTRON UNIVERSAL INPUT AC-DC

H HiTRON
UNIVERSAL INPUT AC-DC INTERNAL OPEN FRAME
SWITCHING POWER SUPPLIES 72 WATTS SINGLE,
DUAL & TRIPLE OUTPUT HVI72 SERIES
FEATURES:
 ACCOMMODATE UNIVERSAL AC INPUT
 OPEN FRAME OR BOX FORMATS
 LOW COST COMMERCIAL GRADE
 MEET UNIVERSAL SAFETY STANDARDS
 EMI MEET CISPR PUB. 22 & FCC CLASS B
 CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Range 90-264Vac.
Rating 100 to 240Vac.
Input Connector: B-S or Molex connector or equivalent.
Input Frequency: 47-63Hz.
Inrush Current: Typical 25A peak at 230Vac.
Input Current: Typical 2.0A at 115Vac, 0.6 A at 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
No Load Operation: No damage.
Overshoot: No voltage spike while power ON/OFF.
Hold-up Time: Typical 20mS at 115Vac,
Typical 80mS at 230Vac.
Earth Leakage Current: Less than 0.5mA at 230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Rating Chart.
Output Connector: B-S or Molex connector or equivalent.
Output Wattage: Typical 72 Watts.
Line Regulation: Typical 0.1%.
Load Regulation: Main VO1 typ. ±1.0%.
Aux. VO2 typ. ±3.0%. (stacked on)
Aux. VO3/VO4 typ. ±2.0%. (P.R.)
Noise & Ripple: Typical 1.0% peak to peak.
OVP: Built-in at main VO1 (Latch).
Adjustability: Available at main VO1.
LED Indicator: Output indicating.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typical 72%. (various with output voltage)
Switching Frequency: Fixed frequency 45KHz.
Circuit Topology: Fixed Frequency Flyback Circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Safety Standard: Meet UL 60950-1/EN 60950-1 Class I.
Operating Temperature: 0 to +50°C.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typical 0.03% /°C.
Cooling: Free air convection cooling.
Construction format: L-Bracket or enclosure box format.
Power Density: 2.0 Watts / Cubic Inch.
NOTE: (1)All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2)Due to requests in market and advances in technology, specifications subject to change without notification.
In application.
-67-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
HVI72-10
HVI72-11
HVI72-12
HVI72-13
HVI72-14
HVI72-15
HVI72-19
MAIN VO1 @
Typ.
Volt.
14.0A
5.0V
6.0A
12.0V
4.8A
15.0V
3.0A
24.0V
2.3A
32.0V
1.6A
48.0V
14.0A
3.3V
TRIPLE OUTPUT
MAIN VO1 @
Typ.
Volt.
7.0A
HVI72-30
+5V
7.0A
HVI72-31
+5V
7.0A
HVI72-32
+5V
7.0A
HVI72-33
+5V
HVI72-050060-BG 6.0A
+5V
MODEL NO.
AUX. +VO2 †
Typ.
Volt.
2.0A
+12V
2.0A
+12V
1.0A
+24V
1.5A
+15V
2.0A
+12V
AUX. ±VO3 ●
Typ.
Volt.
1.0A
12V
1.0A
5V
1.0A
12V
1.0A
15V
1.0A
-12V
QUAD OUTPUT
MODEL NO.
HVI72-40
HVI72-41
HVI72-42
HVI72-43
HVI72-43A
MAIN VO1 @
Typ.
Volt.
6.5A
+5V
6.5A
+5V
6.5A
+5V
6.5A
+5V
5.0A
+5V
AUX. +VO2 †
Typ.
Volt.
2.0A
+12V
2.0A
+12V
1.0A
+24V
1.6A
+15V
1.5A
+15V
AUX. ±VO3 ●
Typ.
Volt.
0.5A
12V
1.0A
5V
0.5A
12V
0.5A
15V
1.0A
-15V
AUX. -VO4 ●
Typ.
Volt.
0.5A
-12V
1.0A
-5V
0.5A
-12V
0.5A
-15V
1.0A
-5V
Symbol: "" OVP built-in. "@" Adjustable. "†" Stacked on main O/P. "●" Installed with Post Regulator (P.R.).
Remark: At least 20% of typical main output current is required to maintain stated regulation.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: L-B 396.0g (13.97 Oz.)
Box 489.0g (1.25 Oz.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT
ASSIGNMENT
AC-LINE AC-NEUTRAL
P1-1
P1-2
B-S CNTR & PIN#
P2-L
P2-N
V-M CNTR & PIN#
Mating connector: P2 Molex 5195 or 5239 series.
AC-GROUND
P1-3
P2-G
SINGLE OUTPUT
VO1
DC-COM
P1-5
P1-4
P3-4,5,6
P3-1,2,3
-68-
VO1
P1-8
P3-7,8
TRIPLE / QUAD OUTPUT
VO2
VO3
VO4
DC-COM
P1-6
P1-5
P1-4
P1-7
P3-3
P3-2
P3-1
P3-4,5