Test and Reliability Data

Test and Reliability Data
Environmental Data
MECHANICAL
Test Number
Test Methods
Requirement
1 Solderability
After steam aging, immerse in
the solder (H63A) of 230 ±5°
for 3 ±0.5 seconds.
Approximately 95% of the
terminal should be covered
with new solder.
2 Terminal Strength
After soldering the parts to a PCB,
perform a pull test with 1Kgf
in any direction for 10 seconds.
No evidence of damage.
∆ C/C within ±1%
∆ R/R within ±1%
3 Vibration
After soldering the parts to a PCB
perform a vibration test with
10Hz to 2KHz at 15 ±1.5gs,
4 hours/plane.
No evidence of damage.
∆ C/C within ±1%
∆ R/R within ±1%
4 Mechanical Shock
1500g 0.5m seconds,
5 times to bath direction.
No evidence of damage.
5 Resistance
to Soldering Heat
Immerse in the solder (H63A)
of 260 ±5°C for 10 ±1 seconds.
No evidence of damage.
∆ C/C within ±1%
∆ R/R within ±1%
6 Resistance to Solvent
Immerse in the IPA (JIS K 8839)
of 23°C for 30 ±5 seconds.
No outstanding damage
and marking can be easily judged.
I
Bolivar Drive, P.O. Box 547, Bradford, PA 16701 USA
■
814-362-5536
I-2
■
Fax: 814-362-8883
■
www.koaspeer.com
Test and Reliability Data
ELECTRICAL
Capacitor Ratings
Test Number
1 Capacitance
Test Methods
Requirement
JIS C 5102 7.8
Measuring Frequency 1KHz
Measuring Frequency 1VRMS
2 Capacitance Tolerance
J: ±5%, K: ±10%, M: ±20%
3 Capacitance
Temperature
Characteristic
JIS C 5102 7.12
0 ±250ppm/°C
4 Voltage Rating
DC Voltage for 10 seconds
across the capacitor.
100V DC
5 Breakdown Voltage
DC Voltage for 1 millisecond
across the capacitor.
500V DC
6 Electrostatic Discharge
MIL-STD-883C method 3015.3
100pF 1.5K Ω
±2KV MIN.
I
Bolivar Drive, P.O. Box 547, Bradford, PA 16701 USA
■
814-362-5536
I-3
■
Fax: 814-362-8883
■
www.koaspeer.com
Test and Reliability Data
ELECTRICAL
Resistor Ratings
Test Number
Test Methods
Requirement
1 Resistance
JIS C 5202 5.1
Method A
2 Resistance Tolerance
Method A
B: ±0.1%, C: ±0.25%, D: ±0.5%
F: ±1%, J: ±5%, K: ±10%, M: ±20%
3 Resistance Temperature
Characteristic
JIS C 5202 5.2
Method B
H: ±100 ppm, E: ±25 ppm
C: ±50 ppm, T: ±10 ppm
4 Insulation Resistance
JIS C 5202 5.6
Measuring Voltage 100V
1000 MΩ (MIN)
5 Power Rating
Resistor
100mW
6 Voltage Rating
Resistors shall have a rated DC or AC (R.M.S.) working voltage
corresponding to the power rating, as determined from the following
equation: In no case shall the rated DC or AC (R.M.S.) working
voltage be greater than 100V.
E: Rated Voltage [V]
P: Rated Power [W]
E=√P•R
R: Resistance [Ω]
I
Bolivar Drive, P.O. Box 547, Bradford, PA 16701 USA
■
814-362-5536
I-4
■
Fax: 814-362-8883
■
www.koaspeer.com
Test and Reliability Data
Environmental Applications
Test Number
Test Methods
Requirement
1 Low Temperature
Characteristics
Store at -40 ±3°C for 1000 hours
No evidence of damage.
∆ C/C within ±1%
∆ R/R within ±1%
2 Resistance of Heat
Store at 125 ±2°C for 1000 hours
No evidence of damage.
∆ C/C within ±1%
∆ R/R within ±1%
3 Moisture Endurance
Temperature: 40 ±2°C
Humidity: 90 ~ 95%
1000 hours
No evidence of damage.
∆ C/C within ±1%
∆ R/R within ±1%
4 Temperature Cycling
100 cycles between
-40°C/30 minutes and
+125°C/30 minutes
No evidence of damage.
∆ C/C within ±1%
∆ R/R within ±1%
5 Pressure Cooker
Temperature: 121°C
Humidity: 100%
Pressure: 2 atm
168 hours
No evidence of damage.
∆ C/C within ±1%
∆ R/R within ±1%
I
Bolivar Drive, P.O. Box 547, Bradford, PA 16701 USA
■
814-362-5536
I-5
■
Fax: 814-362-8883
■
www.koaspeer.com