Test and Reliability Data Environmental Data MECHANICAL Test Number Test Methods Requirement 1 Solderability After steam aging, immerse in the solder (H63A) of 230 ±5° for 3 ±0.5 seconds. Approximately 95% of the terminal should be covered with new solder. 2 Terminal Strength After soldering the parts to a PCB, perform a pull test with 1Kgf in any direction for 10 seconds. No evidence of damage. ∆ C/C within ±1% ∆ R/R within ±1% 3 Vibration After soldering the parts to a PCB perform a vibration test with 10Hz to 2KHz at 15 ±1.5gs, 4 hours/plane. No evidence of damage. ∆ C/C within ±1% ∆ R/R within ±1% 4 Mechanical Shock 1500g 0.5m seconds, 5 times to bath direction. No evidence of damage. 5 Resistance to Soldering Heat Immerse in the solder (H63A) of 260 ±5°C for 10 ±1 seconds. No evidence of damage. ∆ C/C within ±1% ∆ R/R within ±1% 6 Resistance to Solvent Immerse in the IPA (JIS K 8839) of 23°C for 30 ±5 seconds. No outstanding damage and marking can be easily judged. I Bolivar Drive, P.O. Box 547, Bradford, PA 16701 USA ■ 814-362-5536 I-2 ■ Fax: 814-362-8883 ■ www.koaspeer.com Test and Reliability Data ELECTRICAL Capacitor Ratings Test Number 1 Capacitance Test Methods Requirement JIS C 5102 7.8 Measuring Frequency 1KHz Measuring Frequency 1VRMS 2 Capacitance Tolerance J: ±5%, K: ±10%, M: ±20% 3 Capacitance Temperature Characteristic JIS C 5102 7.12 0 ±250ppm/°C 4 Voltage Rating DC Voltage for 10 seconds across the capacitor. 100V DC 5 Breakdown Voltage DC Voltage for 1 millisecond across the capacitor. 500V DC 6 Electrostatic Discharge MIL-STD-883C method 3015.3 100pF 1.5K Ω ±2KV MIN. I Bolivar Drive, P.O. Box 547, Bradford, PA 16701 USA ■ 814-362-5536 I-3 ■ Fax: 814-362-8883 ■ www.koaspeer.com Test and Reliability Data ELECTRICAL Resistor Ratings Test Number Test Methods Requirement 1 Resistance JIS C 5202 5.1 Method A 2 Resistance Tolerance Method A B: ±0.1%, C: ±0.25%, D: ±0.5% F: ±1%, J: ±5%, K: ±10%, M: ±20% 3 Resistance Temperature Characteristic JIS C 5202 5.2 Method B H: ±100 ppm, E: ±25 ppm C: ±50 ppm, T: ±10 ppm 4 Insulation Resistance JIS C 5202 5.6 Measuring Voltage 100V 1000 MΩ (MIN) 5 Power Rating Resistor 100mW 6 Voltage Rating Resistors shall have a rated DC or AC (R.M.S.) working voltage corresponding to the power rating, as determined from the following equation: In no case shall the rated DC or AC (R.M.S.) working voltage be greater than 100V. E: Rated Voltage [V] P: Rated Power [W] E=√P•R R: Resistance [Ω] I Bolivar Drive, P.O. Box 547, Bradford, PA 16701 USA ■ 814-362-5536 I-4 ■ Fax: 814-362-8883 ■ www.koaspeer.com Test and Reliability Data Environmental Applications Test Number Test Methods Requirement 1 Low Temperature Characteristics Store at -40 ±3°C for 1000 hours No evidence of damage. ∆ C/C within ±1% ∆ R/R within ±1% 2 Resistance of Heat Store at 125 ±2°C for 1000 hours No evidence of damage. ∆ C/C within ±1% ∆ R/R within ±1% 3 Moisture Endurance Temperature: 40 ±2°C Humidity: 90 ~ 95% 1000 hours No evidence of damage. ∆ C/C within ±1% ∆ R/R within ±1% 4 Temperature Cycling 100 cycles between -40°C/30 minutes and +125°C/30 minutes No evidence of damage. ∆ C/C within ±1% ∆ R/R within ±1% 5 Pressure Cooker Temperature: 121°C Humidity: 100% Pressure: 2 atm 168 hours No evidence of damage. ∆ C/C within ±1% ∆ R/R within ±1% I Bolivar Drive, P.O. Box 547, Bradford, PA 16701 USA ■ 814-362-5536 I-5 ■ Fax: 814-362-8883 ■ www.koaspeer.com