IXD_609 Series Qual Report Code V3

Reliability Report-IXD_609 Series VIS Foundry Process CU05UMS12010
Qualification No: 2011-001
Reliability Report
Reliability Data for IXD_609 Series VIS Foundry Process
CU05UMS12010
Report Title: Reliability Data for IXD_609 Series VIS Foundry
Process CU05UMS12010
Report Number: 2011-001
Date:
1/7/11
Clare an IXYS Company, 78 Cherry Hill Drive, Beverly, MA 01915, USA
Tel: 1-978-524-6700, Fax: 1-978-524-4700, Toll Free: 1-800-27-CLARE, WWW.CLARE.COM
Page 1 of 6
Reliability Report-IXD_609 Series VIS Foundry Process CU05UMS12010
Qualification No: 2011-001
Introduction:
This report summarizes the Reliability data of Clare’s IXD_609 Series. The Reliability data
presented here were collected during Clare’s product qualification. The purpose of this
qualification was to verify the Clare’s Quality and Reliability requirements as outlined in
Clare’s internal specifications. The IXD_609 Series Gate Driver silicon is foundered at
Vanguard International Semiconductor, Corp. (VIS) and assembled at Atec in the
Philippines. The VIS process is CU05UMS12010.
Reliability Tests:
Table 1 below provides the qualification tests that were performed. The stress tests and
sample size are chosen based on the Clare’s specification P-04-25-WW, “Reliability, Risk
Analysis and Qualification Procedure” and with the approval of the product development
team and quality assurance.
Table 1: Product Family IXD_609 Series Reliability Tests
Stress
Test
HTOL
Applicable Stress
Specs
Conditions
Mil-Std-883 125°C, 80%
HTOL
Mil-Std-883
Latch Up
JESD78
HAST
JESD22,
A110-C
Thermal
Mil-Std-883,
Shock (T/S) M1011
Temp Cycle Mil-Std-883,
(T/C)
N1010, “B”
High Temp JESD22Storage
A103C
MSL
J-STD020D.1
ESD
JESD22,
HBM
A114-E
Product/
Package
IXDD609
SOIC – 8L EP
IXDD609PI
125°C, 80%
8 Pin DIP
Trigger Pulse = 1us, IXDD609
5vpp, VCC = =18V SOIC – 8L EP
IXDD604SIA
130°C, 85%
SOIC – 8L EP
18.8PSI, 96hrs
0 to 100°C, 10/10 IXDD604SIA
dwells, 15 cycles SOIC – 8L EP
-55 to 125°C, 10/10 IXDD604SIA
SOIC – 8L EP
dwells,
300 cycles
IXDD604SIA
125°C, 1000hrs
SOIC – 8L EP
IR Reflow,
IXDD604SIA
Level 1
SOIC – 8L EP
IXDD609
1.5kΩ, 100pF
SOIC – 8L EP
Number Sample Total
of Lots Size (SS) SS
1
77
77
1
90
90
1
2
2
2
76
152
3
55
165
3
55
165
3
50
150
3
50
150
3
25
75
Clare an IXYS Company, 78 Cherry Hill Drive, Beverly, MA 01915, USA
Tel: 1-978-524-6700, Fax: 1-978-524-4700, Toll Free: 1-800-27-CLARE, WWW.CLARE.COM
Page 2 of 6
Reliability Report-IXD_609 Series VIS Foundry Process CU05UMS12010
Qualification No: 2011-001
Reliability Test Results:
The stress tests and associated results for the product family IXD_609 Series qualification
are summarized in Table 2. The devices chosen for the qualification were from standard
material manufactured through normal production test flow and electrically tested to
datasheet limits prior to stressing. Then reliability stresses were conducted and electrically
tested to datasheet limit at each interval and final readpoints.
Table 2: Product Family IXD_609 Series Reliability Test Results
Stress Test
HTOL
HTOL
Latch Up
N-MOS
Product/Kit
Number
IXDD609
S0027
Wafer 002
IXDD609PI
C00039
1023
IXDD609
S0027
Wafer 002
Readpoint
/ (Reject/
SS)
1000 hrs.
Comments
Qual Lot#1 Data
0/77
1000 hrs.
Qual Lot#1 Data
0/90
VNN=10.8V Qual Lot#1 Data
INN=1mA
Current Into
Output=9Amps
0/2
Latch Up
P-MOS
IXDD609
S0027
Wafer 002
VPP=10.6V
Qual Lot#1 Data
IPP=1.1mA
Current Into
Output=9Amps
0/2
HAST
IXDD604SIA
AV0001
0928
IXDD604
C00058
1023
96 hrs.
Qual Lot#1, #2 Data
0/152
Clare an IXYS Company, 78 Cherry Hill Drive, Beverly, MA 01915, USA
Tel: 1-978-524-6700, Fax: 1-978-524-4700, Toll Free: 1-800-27-CLARE, WWW.CLARE.COM
Page 3 of 6
Reliability Report-IXD_609 Series VIS Foundry Process CU05UMS12010
Qualification No: 2011-001
Stress Test
Product/Kit
Number
Thermal Shock IXDD604SIA
AV0001
0928
Thermal Shock IXDD604SIA
AV0002
0929
Thermal Shock IXDD604SIA
AV0005
0944
Temp Cycle
IXDD604SIA
AV0001
0928
Temp Cycle
IXDD604SIA
AV0002
0929
Temp Cycle
IXDD604SIA
AV0005
0944
High Temp
IXDD604SIA
Storage
AV0001
0928
High Temp
Storage
Readpoint
/ (Reject/
SS)
15 Cycles
Comments
Qual Lot#1 Data
0/55
15 Cycles
Qual Lot#2 Data
0/55
15 Cycles
Qual Lot#3 Data
0/55
300 Cycles
Qual Lot#1 Data
0/55
300 Cycles
Qual Lot#2 Data
0/55
300 Cycles
Qual Lot#3 Data
0/55
1000 hrs.
Qual Lot#1 Data
0/50
IXDD604SIA
AV0002
0929
IXDD604SIA
AV0005
0944
IXDD604SIA
AV0001
0928
1000 hrs.
IR Reflow
Level 1
0/50
Qual Lot#1 Data
MSL
IXDD604SIA
AV0002
0929
IR Reflow
Level 1
0/50
Qual Lot#2 Data
MSL
IXDD604SIA
AV0005
0944
IR Reflow
Level 1
0/50
Qual Lot#3 Data
High Temp
Storage
MSL
Qual Lot#2 Data
0/50
1000 hrs.
Qual Lot# 3 Data
0/50
Clare an IXYS Company, 78 Cherry Hill Drive, Beverly, MA 01915, USA
Tel: 1-978-524-6700, Fax: 1-978-524-4700, Toll Free: 1-800-27-CLARE, WWW.CLARE.COM
Page 4 of 6
Reliability Report-IXD_609 Series VIS Foundry Process CU05UMS12010
Qualification No: 2011-001
ESD Testing Results:
As part of this qualification, the product family IXD_609 Series was subjected to Human
Body Model (HBM) ESD Sensitivity Classification testing using a KeyTek Zapmaster
system. The results are summarized in Table 3. All samples were electrically tested to data
sheet limits before and after ESD stressing and they passed after +/-3000V zapping.
Table3: Product Family IXD_609 Series ESD Characterization Results
ESD
Product/Kit Package
ESD Test
RC
Highest
Class
Model Number
Spec
Network Passed
HBM IXDD609
SOIC – 8L EP JESD22,
3000V
2
1.5kΩ,
C00038
A114-E
100pF
FIT (Failure in Time) Rate on the Product Family IXD_609 Series:
Table 4 summarizes the number of devices used for the product family IXD_609 Series
reliability stress with associated failures. Using the HTOL data, FITs were calculated based
on the Acceleration Factor (AF) and equivalent device hours at 0.7eV of activation energy
according to the Clare’s procedure P-04-25-WW for 125°C test temperature and 40°C use
temperatures. The calculated FITs from the reliability stress came out to be 21.57 for
HTOL. Using the HAST data, FITs were calculated based on the Acceleration Factor (AF)
and equivalent device hours at 0.7eV of activation energy according to Clare’s procedure P04-25-WW for 130°C test temperature and 40°C use temperatures. The calculated FITs
from the reliability stress came out to be 44.03 for HAST.
Table 4: Product Family IXD_609 Series FIT Rate Summary
Qual# Stress Product/Kit # of
# of Hours Act.
Acc.
Equivalent FIT Rate
Number
Devices Fails Tested Energy Factor
Dev. Hours @ 60%
CL
1
2
HTOL IXDD609
S0027
Wafer 002
IXDD609PI
C00039
1023
HAST IXDD604SIA
AV0001
0928
IXDD604SIA
C00058
1023
167
0
1000
0.7
152
0
96
0.7
255.41
42,652,796
21.57
20,892,615
44.03
1.4318E
+03
Clare an IXYS Company, 78 Cherry Hill Drive, Beverly, MA 01915, USA
Tel: 1-978-524-6700, Fax: 1-978-524-4700, Toll Free: 1-800-27-CLARE, WWW.CLARE.COM
Page 5 of 6
Reliability Report-IXD_609 Series VIS Foundry Process CU05UMS12010
Qualification No: 2011-001
Conclusion:
The qualification of the product family IXD_609 Series has been successfully completed for
the production release. The reliability and process data for VIS CU05UMS12010 can be
found at S:/REED/Projects/New Process Information/Vanguard.
Clare an IXYS Company, 78 Cherry Hill Drive, Beverly, MA 01915, USA
Tel: 1-978-524-6700, Fax: 1-978-524-4700, Toll Free: 1-800-27-CLARE, WWW.CLARE.COM
Page 6 of 6