MG200xE Series Low Cost, 2W Compact MiniDIP DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 2W Output Power • Compact MiniDIP Case Input Parameter Input Voltage Range • High Efficiency • 1,500 VDC Isolation Input Filter • Single and Dual Outputs Output • >3.5 MHour MTBF Parameter Output Voltage Accuracy Line Regulation Load Regulation, See Note 1 • -40°C to +85°C Operation • LOW COST Ripple & Noise (20 MHz), See Note 2 3.0 kV Isolation Models Available Conditions Min. 3.3 VDC Input 2.97 5 VDC Input 4.50 12 VDC Input 10.80 24 VDC Input 21.60 Internal Capacitor Typ. 3.3 5.0 12.0 24.0 Max. 3.63 5.50 13.20 26.40 Units Conditions Typ. ±2.5 Max. Units % % Min. For VIN Change of 1% See Model Selection Guide Output Voltage <12 VDC 60 15 VDC, 24 VDC Output 75 Temperature Coefficient 5 VDC & 12 VDC Input 3.3 VDC & 24 VDC Input Output Short Circuit ±1.2 VDC mV P - P ±0.03 %/°C Continuous (Autorecovery) Momentary (1.0 Sec.) General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency EMI Characteristics Parameter Conditions 60 Seconds 500 VDC 100 kHz, 0.1V Conditions EMC Compliance, Single Output EMC Compliance, Dual Output Typ. Max. 20 100 300 Units VDC M pF kHz Min. Conducted Radiated EMI Compliance, See Note 4 Min. 1,500 1,000 Electrostatic Discharge (ESD) Typ. Max. Units CISPR22/EN 55022 Level B CISPR22/EN 55022 Level B EN 61000-4-2 Level B Contact ±8 kV EN 61000-4-2 Level B Contact ±6 kV Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Min. Typ. -40 +25 -55 Free Air Convection RH, Non-condensing Ambient Max. +85 +125 Units °C °C 95 % 0.787 x 0.394 x 0.323 Inches (20.0 x 10.0 x 8.2 mm) Non-Conductive Black Plastic (UL-94V0) 0.08 Oz (2.4g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 3.5 Typ. Max. Units MHours Conditions 3.3 VDC Input 5 VDC Input 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. 5.0 9.0 18.0 30.0 300 Units Absolute Maximum Ratings T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Input Voltage Surge (1 Sec) Lead Temperature Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number MG203S-05E MG205S-05E MG205S-12E MG205S-15E MG205D-05E MG205D-09E MG205D-12E MG205D-15E MG212S-05E MG212S-12E MG212S-24E MG212D-05E MG212D-09E MG212D-12E MG212D-15E MG224S-05E MG224S-09E MG224S-12E MG224D-05E MG224D-09E MG224D-15E Output Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 3.3 2.97 - 3.63 757 40 5 4.5 - 5.5 500 25 5 4.5 - 5.5 476 25 5 4.5 - 5.5 476 25 5 4.5 - 5.5 500 25 5 4.5 - 5.5 482 25 5 4.5 - 5.5 476 25 5 4.5 - 5.5 476 25 12 10.8 - 13.2 205 15 12 10.8 - 13.2 198 15 12 10.8 - 13.2 198 15 12 10.8 - 13.2 205 15 12 10.8 - 13.2 198 15 12 10.8 - 13.2 196 15 12 10.8 - 13.2 198 15 24 21.6 - 26.4 101 8 24 21.6 - 26.4 99 8 24 21.6 - 26.4 99 8 24 21.6 - 26.4 101 8 24 21.6 - 26.4 99 8 24 21.6 - 26.4 99 8 Voltage Current (VDC) (mA, Max) 5.0 5.0 12.0 15.0 ±5.0 ±9.0 ±12.0 ±15.0 5.0 12.0 24.0 ±5.0 ±9.0 ±12.0 ±15.0 5.0 9.0 12.0 ±5.0 ±9.0 ±15.0 400 400 167 133 ±200 ±111 ±83 ±67 400 167 83 ±200 ±111 ±83 ±67 400 222 167 ±200 ±111 ±67 Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. When measuring output ripple, it is recommended that an external 1 µF ceramic capacitor & 10 µF electrolytic capacitor be placed in parallel from the +Vout pin to the -Vout pin for single output models, or from each output to common for dual output models. 3. Operation at no load will not damage these units, however, they may not meet all specifications. 4. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple. The simple connection shown below will typically meet EN 55022 Class B. For dual output units, a capacitor should be connected from each output to common. VIN 3.3 VDC 5 VDC 12 VDC 24 VDC C1 4.7 µF/50V 4.7 µF/50V 2.2 µF/50V 1.0 µF/50V L1 6.8 µH 6.8 µH 6.8 µH 6.8 µH VOUT 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC ±5 VDC ±7 VDC ±9 VDC ±12 VDC ±15 VDC Output Load Capacitive Efficiency Fuse Rating Regulation Load Slow-Blow Current (%, Typ) (µF Max) (mA) (mA, Min) % Typ. 40.0 12.0 220 80 1,500 40.0 12.0 220 80 1,000 17.0 8.0 220 84 1,000 13.0 7.0 220 84 1,000 ±20.0 12.0 100 80 1,000 ±11.0 9.0 100 83 1,000 ±8.0 8.0 100 84 1,000 ±7.0 7.0 100 84 1,000 40.0 12.0 220 81 500 17.0 8.0 220 84 500 8.0 6.0 220 84 500 ±20.0 12.0 100 81 500 ±11.0 9.0 100 84 500 ±8.0 8.0 100 85 500 ±7.0 7.0 100 84 500 40.0 12.0 220 82 250 22.0 9.0 220 84 250 17.0 8.0 220 84 250 ±20.0 12.0 100 82 250 ±11.0 9.0 100 84 250 ±7.0 7.0 100 84 250 Derating Curve Mechanical Dimensions C2 10 µF 4.7 µF 2.2 µF 1.0 µF 1.0 µF 4.7 µF 2.2 µF 2.2 µF 1.0 µF 0.47 µF 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin Single Dual Pin Single Dual 1 -VIN -VIN 9 +VOUT +VOUT 7 NC NC 11 No Pin -VOUT 8 -VOUT Common 14 +VIN +VIN NC = No Connection MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Pin 1 is marked by a “dot” or indentation on the unit FAX: (781) 344-8481 • E-Mail: [email protected]