MG200xEI Series High Isolation, 2W Compact MiniDIP DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 2W Output Power • Compact MiniDIP Case Input Parameter Conditions Min. 5 VDC Input 4.50 12 VDC Input 10.80 15 VDC Input 13.50 24 VDC Input 21.60 Internal Capacitor Input Voltage Range • 3,000 VDC Isolation • High Efficiency Input Filter • Single and Dual Outputs Output • >3.5 MHour MTBF Parameter Output Voltage Accuracy Line Regulation Load Regulation, See Note 1 • -40°C to +85°C Operation • LOW COST Ripple & Noise (20 MHz), See Note 2 1.5 kV Isolation Models Available Conditions Min. Max. 5.50 13.20 16.50 26.40 Units Typ. ±2.5 Max. Units % % For VIN Change of 1% See Model Selection Guide Output Voltage <12 VDC 60 15 VDC, 24 VDC Output 75 Temperature Coefficient 5 VDC, 12 VDC & 15 VDC Input 24 VDC Input Output Short Circuit Typ. 5.0 12.0 15.0 24.0 ±1.2 VDC mV P - P ±0.03 %/°C Continuous (Autorecovery) Momentary (1.0 Sec.) General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency EMI Characteristics Parameter Conditions 60 Seconds 500 VDC 100 kHz, 0.1V Conditions EMC Compliance, Single Output EMC Compliance, Dual Output Typ. Max. 20 100 300 Units VDC M pF kHz Min. Conducted Radiated EMI Compliance, See Note 4 Min. 3,000 1,000 Electrostatic Discharge (ESD) Typ. Max. Units CISPR22/EN 55022 Level B CISPR22/EN 55022 Level B EN 61000-4-2 Level B Contact ±8 kV EN 61000-4-2 Level B Contact ±6 kV Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Min. Typ. -40 +25 -55 Free Air Convection RH, Non-condensing Ambient Max. +85 +125 Units °C °C 95 % 0.787 x 0.394 x 0.323 Inches (20.0 x 10.0 x 8.2 mm) Non-Conductive Black Plastic (UL-94V0) 0.08 Oz (2.4g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 3.5 Typ. Max. Units MHours Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. 9.0 18.0 21.0 30.0 300 Units Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature 5 VDC Input 12 VDC Input 15 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number Voltage (VDC) Output Load Capacitive Efficiency Fuse Rating Load Regulation Slow-Blow (µF Max) (%, Typ) Output Current (mA) Voltage Current Current Full-Load No-Load (VDC) (mA, Max) (mA, Min) (mA) Nominal Range MG205S-05EI 5 4.5 - 5.5 500 25 5.0 400 40.0 12.0 220 80 1,000 MG205S-12EI 5 4.5 - 5.5 476 25 12.0 167 17.0 8.0 220 84 1,000 MG205S-15EI 5 4.5 - 5.5 476 25 15.0 133 13.0 7.0 220 84 1,000 MG205D-05EI 5 4.5 - 5.5 500 25 ±5.0 ±200 ±20.0 12.0 100 80 1,000 MG205D-12EI 5 4.5 - 5.5 476 25 ±12.0 ±83 ±8.0 8.0 100 84 1,000 MG205D-15EI 5 4.5 - 5.5 476 25 ±15.0 ±67 ±7.0 7.0 100 84 1,000 MG212S-05EI 12 10.8 - 13.2 205 15 5.0 400 40.0 12.0 220 81 500 MG212S-15EI 12 10.8 - 13.2 198 15 15.0 133 13.0 7.0 220 84 500 MG212D-15EI 12 10.8 - 13.2 198 15 ±15.0 ±67 ±7.0 7.0 100 84 500 MG215D-15EI 15 13.5 - 16.5 157 10 ±15.0 ±67 ±7.0 7.0 100 85 300 MG224S-05EI 24 21.6 - 26.4 101 8 5.0 400 40.0 12.0 220 82 250 MG224S-09EI 24 21.6 - 26.4 99 8 9.0 222 22.0 9.0 220 84 250 MG224S-15EI 24 21.6 - 26.4 99 8 15.0 133 13.0 7.0 220 84 250 MG224D-12EI 24 21.6 - 26.4 99 8 ±12.0 ±83 ±8.0 8.0 100 84 250 MG224D-15EI 24 21.6 - 26.4 99 8 ±15.0 ±67 ±7.0 7.0 100 84 250 Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. When measuring output ripple, it is recommended that an external 1 µF ceramic capacitor & 10 µF electrolytic capacitor be placed in parallel from the +Vout pin to the -Vout pin for single output models, or from each output to common for dual output models. 3. Operation at no load will not damage these units, however, they may not meet all specifications. 4. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple. The simple connection shown below will typically meet EN 55022 Class B. For dual output units, a capacitor should be connected from each output to common. VIN 5 VDC 12 VDC 15 VDC 24 VDC C1 4.7 µF/50V 2.2 µF/50V 2.2 µF/50V 1.0 µF/50V C2 --470 pF/3 kV 470 pF/3 kV 470 pF/3 kV L1 6.8 µH 6.8 µH 6.8 µH 6.8 µH VOUT 5 VDC 9 VDC 12 VDC 15 VDC ±5 VDC ±12 VDC ±15 VDC C3 10 µF 4.7 µF 2.2 µF 1.0 µF 4.7 µF 1.0 µF 0.47 µF % Typ. Derating Curve Mechanical Dimensions 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin Single Dual Pin Single Dual 1 -VIN -VIN 9 No Pin Common 7 NC NC 10 -VOUT -VOUT 8 +VOUT +VOUT 14 +VIN +VIN NC = No Connection MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Pin 1 is marked by a “dot” or indentation on the unit FAX: (781) 344-8481 • E-Mail: [email protected]