MPM-07PB Series Compact 1 x 2 Inch 7W, Single Output AC/DC Power Supplies Electrical Specifications Key Features: • 7W Output Power • Compact 1 x 2 Inch Case • Universal 85-264 VAC Input • EN 60950 Approved (UL) • ErP Directive Compliant • Meets EN 55022 B • Meets IEC Safety Class II • >330 kHour MTBF Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 230 VAC Input Voltage Range Input Frequency Input Current Inrush Current No Load Power Consumption Max. 264 370 440 10.0 20.0 0.3 Units VAC VDC Hz A Pk W Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz), See Note 1 Hold-Up Time Temperature Coefficient Over Voltage Protection Over Temperature Protection Short Circuit Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide ±1.0 ±0.5 VIN = Min to Max IOUT = 0% to 100% ±0.5 3.3V and 5V Models 1.5 12V, 15V, and 24V Models 0.8 115 VAC 20 230 VAC 60 ±0.01 Zener Diode Clamp 120 Autorecovery (at 67 °C) 90 Continuous (Autorecovery) Foldback, Autorecovery 105 Max. Units ±2.0 ±1.0 ±1.0 1.8 1.0 % % % ±0.02 % V P-P of VOUT mSec %/°C %VOUT °C %W General Parameter Isolation Voltage Isolation Resistance Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFM Voltage Dips MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Conditions Input to Output 500 VDC Min. 3,000 100 Typ. Max. 100 Standard Min. EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 Units VAC M kHz Typ. Max. Units Class B Class B Criteria B; ±8 kV Air/±4 kV Contact Criteria A; 10V/m Criteria B; ±2 kV Criteria B; ±1 kV Criteria B; 10 Vrms Criteria A; 30A/m Criteria B; 10 mS Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +70 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % Physical Case Size Case Material Weight 2.00 x 1.00 x 0.76 Inches (50.8 x 25.4 x 19.3 mm) Non-Conductive Black Plastic (UL94-V0) 1.55 Oz (44g) Reliability Specifications Parameter MTBF Safety Standards Safety Class ECO Design Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 EN 60950 IEC 60536 Class II ErP Directive 2009/125/EC www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Model Number Input Current (A) Output 1 (Vout 1) Current (A) Voltage (VDC) 115 VAC 230 VAC Max. Min. Fuse Efficiency Capacitive Rating Load (%, Typ) (µF Max) Slow-Blow (mA) MPM-07S-03PB 0.96 0.051 3.3 1.400 0.140 70 2,200 1,500 MPM-07S-05PB 0.139 0.051 5.0 1.400 0.140 73 2,200 1,500 MPM-07S-12PB 0.130 0.051 12.0 0.583 0.058 78 1,000 1,500 MPM-07S-15PB 0.130 0.051 15.0 0.466 0.047 78 1,000 1,500 MPM-07S-24PB 0.130 0.051 24.0 0.291 0.029 78 680 1,500 Other outputs may be available Contact the factory for details at: [email protected] Derating Curve Notes: 1. Load regulation is measured for an output change of 0% to 100% at nominal input line. 2. Operation at no-load will not damage these units. However, they may not meet all specifications. 3. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit. 5. It is recommended that an external slow blow fuse also be used on the input for protection. See the table above for the correct rating. Mechanical Dimensions Pin Connections MicroPower Direct Pin Function 1 2 3 4 AC-Neutral AC-Line +Vout -Vout Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]