MPM-08MB Series Single & Dual Output, 8W Miniature “Power Brick” AC/DC Power Supplies Key Features: Electrical Specifications • 8W Output Power • Miniature Case • Wide 90-305 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Meets EN 55022 B • Eight Standard Models • >350 kHour MTBF Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Min. Typ. 90 120 47 See Model Selection Guide 115 VAC 25.0 230 VAC 45.0 Input Voltage Range Input Frequency Input Current Inrush Current Leakage Current EMI EMC Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation, See Note 2 Load Regulation, See Note 3 Ripple (20 MHz), See Note 4 Noise Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, See Note 5 Overload Protection General Parameter Isolation Voltage Isolation Resistance EMI/RFI EMC Compliance MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Switching Frequency Environmental Parameter Operating Temperature Range, Ambient Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Vibration Safety Approvals Safety Class Max. 305 430 440 Units VAC VDC Hz A Pk 0.25 mA Max. Units Meets CISPR Pub. 22/FCC Class B Meets EN 55024 Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Note 1 ±2.0 VIN = Min to Max ±0.2 See Model Selection Guide 3.3, 5, 9 12, 15 Vout Models 24 Vout Models Dual Output Models 3.3, 5, 9 12, 15 Vout Models 24 Vout Models Dual Output Models 115 VAC 10 230 VAC 75 ±0.02 Zener Diode Clamp 120 Continuous (Autorecovery) 115 150 Conditions Input to Output 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 100 Typ. % % 100 150 100 150 200 150 mV P - P mV P - P mSec %/°C % of VO % of IO Units VAC M⍀ EN 55022 Level B EN 61000-4-2 Level B EN 61000-4-3 EN 61000-4-4 Level 3 2 kV EN 61000-4-5 Level 3 1kV/2 kV 132 kHz Conditions 5.0/3.3 Vout Model All Other Models Max. Min. Typ. Max. -25 +25 +70 -40 +25 +70 -40 +125 Free Air Convection (See Derating Curves) RH, Non-condensing 95 Units °C °C % 1.44 x 1.06 x 1.04 Inches (36.5 x 27.0 x 26.4 mm) Non-Conductive Plastic & Fiberglass (UL94-V0) 1.58 Oz (45g) Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 350 kHours 10~55 Hz, 20G 1 min/1 Cycle. Period of 3 min each along X, Y &Z Axis UL, cUL; File No. E245422 IEC 61140 Class II www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Input Model Number Current (A) 115 VAC 0.190 0.190 0.190 0.190 0.190 0.190 230 VAC 0.120 0.120 0.120 0.120 0.120 0.120 MPM-08D-0503MB 0.200 0.125 MPM-08D-1205MB 0.200 0.125 MPM-08S-03MB MPM-08S-05MB MPM-08S-09MB MPM-08S-12MB MPM-08S-15MB MPM-08S-24MB Output Voltage (VDC) 3.3 5.0 9.0 12.0 15.0 24.0 5.0 3.3 12.0 5.0 Load Regulation Current Max. (A) 2.000 1.600 0.888 0.666 0.533 0.335 1.600 0.310 0.666 0.100 Min. (%) 0.0 0.0 0.0 0.0 0.0 0.0 25.0 25.0 25.0 25.0 Notes: 1. The output voltage accuracy of the V2 output (pin 5) on dual outputs is ±15% for the MPM-08D0503MB, and ±10% for the MPM-08D-1205MB. 2. The line regulation of the dual output models is ±2.0% for the V1 output (pin 4), and ±3% for the V2 output (pin 5). 3. Load regulation is measured from 10% load to 100% load. 4. Ripple and noise are measured at 20 Mhz bandwidth with a 0.1µF and a 47 µF capacitor connected in parallel as close to the unit output terminals as possible. 5. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 6. Operation under no load conditions will not damage single output units. For dual output units, minimum load requirements are given in the table above. 7. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-08MB series, a 2A/250 VAC slow blow should be used. (% Max) Maximum Capacitive Load (µF) ±3.0 ±2.0 ±0.5 ±0.5 ±0.5 ±0.5 ±0.5 ±5.0 ±0.5 ±5.0 26,000 6,000 2,300 1,050 440 180 4,500 3,800 260 3,800 Maximum Efficiency Output Power (%, Typ) (W) 6.60 8.00 8.00 8.00 8.00 8.00 72 78 79 79 80 81 9.00 76 8.50 79 Mechanical Dimensions Derating Curve - Single Output Models Derating Curve - Dual Output Models Pin Connections Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Pin Single Dual 1 AC-Line 2 AC-Neutral 3 -Vout Common 4 +Vout Vout1 5 NC Vout2 NC = No Connection MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]