MPD MPM-15CM

MPM-15CM Series
Ch
Chassis
i M
Mount,
t 15W
Single, Dual & Triple Out
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 15W Output Power
• Universal 85-265 VAC Input
• EN60950 Approved
• Single, Dual & Triple Outputs
• Meets EN55022 B
• Meets IEC Safety Class II
• Chassis Mount Case
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
DIN Rail Mounting
Kit Available!
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
EMI
Safety Ground Leakage Current
Conditions
Min.
Typ.
Max.
85
265
47
440
See Model Selection Guide
115 VAC
15.0
230 VAC
30.0
Meets CISPR Pub. 22/FCC Class B
115 VAC
0.1
230 VAC
0.3
Units
VAC
Hz
Conditions
Min.
Typ.
Max.
See Model Selection Guide
See Model Selection Guide
±1.0
±2.0
VIN = Min to Max
±0.2
±1.0
IO = Min to Max
±0.5
±1.0
IO = Min to Max
±2.5
±5.0
5.0 VDC Output
1.5
1.8
All Other Outputs
0.8
1.0
115 VAC, 60 Hz
20
±0.02
Zener Diode Clamp
120
Continuous (Autorecovery)
Typ. 120% to 180% of Output Power
Units
A Pk
mA
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual, Triple Aux Output
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, Note 3
Overload Protection, Note 4
%
%
%
%
%VP-P of VO
mSec
%/°C
% of VO
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
EMC Compliance
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Input to Output
Input to Output, Flash Tested For 60S
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Switching Frequency
Min.
3,000
4,700
100
Typ.
Max.
Units
VAC
VAC
MΩ
EN 55022 Level B
IEC/EN 61000-4-2 Level B
IEC/EN61000-4-3
IEC/EN 61000-4-4 Level 3 2 kV
IEC/EN 61000-4-5 Level 3 1kV/2 kV
100
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
Max.
-25
+25
+71
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
Physical
Case Size, Chassis Mount
Case Size, DIN Rail Option
Case Material
Weight
3.81 x 2.13 x 0.92 Inches (96.7 x 54.0 x 23.3 mm)
3.81 x 2.13 x 1.35 Inches (96.7 x 54.0 x 34.3 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
5.69 Oz (162g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
280
IEN 60950, IEC 60950
IEN 60950, IEC 60950
IEC 61140 Class II
Max.
Units
kHours
Model Selection Guide
Model
Number
MPM-15S-05CM
MPM-15S-12CM
MPM-15S-15CM
MPM-15S-24CM
MPM-15S-48CM
MPM-15D-12CM
MPM-15D-15CM
MPM-15T-0512CM
MPM-15T-0515CM
Output 2 (Vout 2)
Current (A)
Voltage
(VDC)
Max.
Min.
Input
Current (A)
Output 1 (Vout 1)
Current (A)
Voltage
115 VAC 230 VAC (VDC)
Max.
Min.
0.290
0.275
0.275
0.275
0.273
0.275
0.275
0.290
0.284
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
5.0
12.0
15.0
24.0
48.0
+12.0
+15.0
5.0
5.0
3.000
1.250
1.000
0.625
0.310
+0.625
+0.500
2.000
1.80
Other output combinations are available
Contact the factory for details at:
[email protected]
0.300
0.125
0.100
0.063
0.030
+0.063
+0.050
+0.200
+0.200
-12.0
-15.0
+12.0
+15.0
-0.625
-0.500
+0.200
+0.150
-0.063
-0.050
+0.020
+0.015
Output 3 (Vout 3)
Current (A)
Voltage
(VDC)
Max.
Min.
-12.0
-15.0
-0.200
-0.150
-0.020
-0.015
Capacitive
Efficiency
Load
(%, Typ)
(µF, Max)
3,900
2,200
2,200
2,200
1,000
±1,500
±1,500
Note 5
Note 5
75
79
79
79
79
79
79
74
74
Derating Curve
Notes:
1. Load regulation is measured for an output change of 0% to 100%
at nominal input line. For multiple output models, the loads are
balanced.
2. Operation at no-load will not damage these units. However, they
may not meet all specifications.
3. Output short circuit protection is provided by a “hiccup mode”
circuit. The unit recovers automatically when the fault condition
is removed.
4. Output overload protection is provided by a fold back current
limiting circuit.
5. For triple output models, the maximum capacitive load for 5 VDC
outputs is 2,200 µF. For all other outputs it is ±1,500 µF.
6. The MPM-15CM series includes a built-in 2.0A/250 VAC fuse. It is
recommended that an external 1.5A slow blow fuse also be used
on the input for protection.
Mechanical Dimensions, Chassis Mount
Pin Connections
Pin
Single
Dual
Triple
1
AC-Neutral
2
AC-Line
3
+Vo
+Vo
+Vo 2
4
NC
NC
+Vo 1
5
-Vo
Common
Common 2/3
6
NC
NC
-Vo 1
7
NC
-Vo
+Vo 3
NC = No Connection
A DIN Rail mounting kit is available
Contact the factory for details at:
[email protected]
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.
x.xx = ±0.01 (±0.25)
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•