MPO-75S Datasheet - Micropower Direct

MPO-75S Series
Single Output, 75W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 75W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
• Universal 90-264 AC Input
Input Voltage Range
• EN 60950 Approved
Input Frequency
Input Filter
Input Current
• Low Leakage Current
• Four Single Output Models
• Meets EN 55022 B
• >50 kHour MTBF
• Compact 4.1 x 2.05 x 1.2”
Conditions
Min.
Typ.
Max.
90
264
120
370
47
63
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
20.0
Cold Start, 230 VAC
40.0
264 VAC
3.5
Universal
Inrush Current
Safety Ground Leakage Current
Units
VAC
VDC
Hz
A Pk
mA
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz), See Note 1
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
±2.0
Vin = Min to Max
±1.0
Iout = 5% to 100%
±1.0
5V Output
12V Output
15V Output
24V Output
115 VAC
18
±0.02
Continuous (Autorecovery)
See Model Selection Guide
See Note 2 130
Max.
Units
150
%
Conditions
Input to Output
Input to Ground
Output to Ground
500 VDC
Max.
Units
%
%
%
100
150
200
300
mV P-P
mSec
%/°C
General
Parameter
Isolation Voltage
Isolation resistance
Isolation Capacitance
EMI/RFI
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
EMC Compliance
Switching Frequency
MicroPower Direct
Environmental
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
3,000
1,500
500
Typ.
VAC
100
M⍀
4,700
pF
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
133
kHz
Conditions
Min.
Typ.
Max.
-25
+25
+70
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
4.1 x 2.05 x 1.2 Inches (103.9 x 52.1 x 30.0 mm)
6.77 Oz (0.195 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
50
kHours
UL 1950, EN 60950, IEC 60950
10~500 Hz, 5G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPO-75S-05T
MPO-75S-12T
MPO-75S-15T
MPO-75S-24T
Input
Current (A)
115 VAC
230 VAC
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
Voltage
(VDC)
5.0
12.0
15.0
24.0
Output
Current (A)
Rated
% Min.
10.00
6.25
5.00
3.13
1.00
1.00
1.00
1.00
Max
Output
Power
Over
Voltage
Protection
(W)
(VDC)
50
75
75
75
6.2
15.0
18.0
28.0
Efficiency
(%, Typ)
73
80
80
80
Derating Curve
For U-channel and enclosed models, see MPU-75S Datasheet
Notes:
1. Output ripple and noise is measured at 20 MHz bandwidth using a 0.1 µF and
47 µF capacitor connected in parallel as close to the power supply terminals
as possible.
2. Overload protection is provided by a “hiccup mode” circuit. The unit recovers
automatically when the fault condition is removed.
3. Over voltage protection is provided by a zener diode clamp.
4. These units will operate at no load without damage, however, MPD recommends that a minimum 1% load always be used .
5. Each unit includes an input fuse. Since this fuse is not field replaceable, it is
recommended that an external fuse be used on the input of the power supply
for protection. For these units, a 15A/250V slow blow fuse is recommended.
Mechanical Dimensions
Pin Connections
Pin
1
2
3
MicroPower Direct
Function
Pin
Function
AC-Neutral
AC-Line
AC-Ground
4
5
+VOUT
-VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•