MEANWELL LPC-35-1400

LPC-35 series
35W Single Output Switching Power Supply
MODEL:LPC-35-1400
OUTPUT FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RIPPLE & NOISE
V1: 200
I/P: 230VAC
mVp-p (Max )
RESULT
V1:
VERDICT
70
mVp-p (Max )
O/P:FULL LOAD
Ta:25℃
2
OUTPUT VOLTAGE
CH1: 9 V~ 24 V
RANGE
P
I/P: 230 VAC
0
V~
24.1
V/ 230 VAC
I/P: 115 VAC
0
V~
24.1
V/ 115 VAC
V1:
0.2
%~
-0.2
P
O/P:MIN LOAD
Ta:25℃
3
OUTPUT VOLTAGE
V1: 5 %~ -5 % (Max)
TOLERANCE
4
LINE REGULATION
I/P: 100 VAC / 264 VAC
O/P:FULL/ MIN
Ta:25℃
V1: 1 %~ -1 % (Max)
%
LOAD
I/P: 100VAC ~ 264 VAC
P
V1:
0
%~
0
%
O/P:FULL LOAD
Ta:25℃
5
LOAD REGULATION
V1: 2 %~ 2 % (Max)
I/P: 230 VAC
P
V1:
0.2
%~
-0.2
%
O/P:FULL ~MIN LOAD
Ta:25℃
6
SET UP TIME
P
230VAC:
500
ms (Max)
I/P: 230 VAC
230VAC/
139
ms
115 VAC:
500
ms (Max)
I/P: 115 VAC
115VAC/
1.03
ms
O/P:FULL LOAD
Ta:25℃
7
RISE TIME
230VAC:
115VAC:
120
120
ms (Max)
I/P: 230 VAC
230VAC/
18
ms
ms (Max)
I/P: 115 VAC
115VAC/
16
ms
O/P:FULL LOAD
Ta:25℃
8
HOLD UP TIME
230VAC:
50
ms (TYP)
I/P: 230 VAC
230VAC/
138
ms
115VAC:
16
ms (TYP)
I/P: 115 VAC
115VAC/
30
ms
TEST:
<5
%
O/P:FULL LOAD
Ta:25℃
9
OVER/UNDERSHOOT TEST
I/P: 230 VAC
< +5%
O/P:FULL LOAD
Ta:25℃
10
DYNAMIC LOAD
V1:
2400
mVp-p
I/P: 230 VAC
P
P
P
P
299
mVp-p
O/P:FULL /Min LOAD
P
90%DUTY/1KHZ
Ta:25℃
Model: LPC-35-1400
Test Report
1 / 5
LPC-35 series
35W Single Output Switching Power Supply
INPUT FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
INPUT VOLTAGE RANGE
90VAC~264 VAC
I/P:TESTING
RESULT
VERDICT
52 V~264V
O/P:FULL LOAD
Ta:25℃
I/P:
TEST: OK
LOW-LINE-3V= 87 V
P
HIGH-LINE+15%=300 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
( AC POWER ON/OFF NO DAMAGE )
2
INPUT FREQUENCY RANGE
47HZ ~63 HZ
I/P:100 VAC ~ 264 VAC
NO DAMAGE OSC
3
85% (TYP)
EFFICIENCY
TEST: OK
O/P:FULL~MIN LOAD
Ta:25℃
P
I/P: 230 VAC
86.2%
O/P:FULL LOAD
Ta:25℃
4
INPUT CURRENT
P
230V/
0.7
A (TYP)
I/P: 230 VAC
I=
0.3
A/ 230 VAC
115V/
1.1
A (TYP)
I/P: 115 VAC
I=
0.5
A/ 115 VAC
P
O/P:FULL LOAD
Ta:25℃
5
INRUSH CURRENT
230V/
60
A (TYP)
I/P: 230 VAC
I=
48
A/ 230 VAC
115V/
30
A(TYP)
I/P: 115 VAC
I=
24
A/ 115 VAC
I/P: 264 VAC
L-FG:
0.01
mA
O/P:Min LOAD
Ta:25℃
N-FG:
0.01
mA
COLD START
6
LEAKAGE CURRENT
<
0.25
P
O/P:FULL LOAD
Ta:25℃
mA / 240 VAC
P
PROTECTION FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
CURRENT LIMIT
95 %~ 105 %
I/P: 230 VAC
I/P: 115 VAC
O/P:TESTING
Ta:25℃
2
OVER VOLTAGE PROTECTION
CH1:27.6 V~ 32.4 V
I/P: 230 VAC
I/P: 115 VAC
3
SHORT PROTECTION
RESULT
VERDICT
100 %/ 230 VAC
100%/ 115 VAC
Constant Current Limiting
P
30V/ 230 VAC
30V/ 115 VAC
O/P:MIN LOAD
Ta:25℃
Shut down Re- power ON
SHORT EVERY OUTPUT
I/P: 264 VAC
NO DAMAGE
1 HOUR NO DAMAGE
O/P:FULL LOAD
Ta:25℃
Constant Current Limiting
P
P
Model: LPC-35-1400
Test Report
2 / 5
LPC-35 series
35W Single Output Switching Power Supply
ENVIRONMENT TEST
NO
1
TEST ITEM
SPECIFICATION
TEMPERATURE RISE TEST
MODEL: LPC-35-1400
TEST CONDITION
RESULT
VERDICT
1. ROOM AMBIENT BURN-IN:3 HRS
I/P: 230VAC O/P: FULL LOAD Ta=29 ℃
2. HIGH AMBIENT BURN-IN: 1 HRS
I/P: 230VAC O/P: FULL LOAD Ta=62.9 ℃
NO
2
OVER LOAD BURN-IN TEST
Position
ROOM AMBIENT HIGH AMBIENT
Ta=29 ℃
Ta=62.9 ℃
50.2℃
77.2℃
P/N
1
LF1
2
BD1
53.9℃
80.3℃
3
C5
100u/400V 105℃
KMG
54.8℃
81.2℃
4
D1
SFRD EGP20J 2A/600V
65.9℃
91.1℃
5
T1
TF1797
65.7℃
89.8℃
67.3℃
93.0℃
58.1℃
83.8℃
1A/100V 1N4002
63.1℃
88.7℃
98.4℃
6
Q1
7
C40
8
D40
LF158
2A/800V
KBP208G
STF6NM60N :600 V/ 4.6A
47u/50V UL10Kh
YXM
9
D100
FMX-12SL 10A/200V
75.3℃
10
D200
HER102 1A/100V
69.0℃
92.7℃
11
U1
NCP1200D60R2G
54.2℃
80.4℃
12
C105
470u/35V L7Kh 10*20 YXG
62.1℃
85.6℃
13
LF100
TR574-R1
53.9℃
77.9℃
14
C200
22u/50V L5Kh 5*11 KY
63.4℃
87.0℃
NO DAMAGE
I/P: 230 VAC
O/P:101 ﹪LOAD
1 HOUR ( MIN )
P
TEST:OKO
P
Ta:29.1℃
3
LOW TEMPERATURE
TURN ON AFTER
2 HOUR
TURN ON TEST
I/P: 230 VAC
O/P: 95 ﹪LOAD
TEST:OK
P
Ta= -35 ℃
4
HIGH HUMIDITY
AFTER 12 HOURS
HIGH TEMPERATURE
IN CHAMBER ON
CONTROL 65℃
HIGH VOLTAGE
TURN ON TEST
5
TEMPERATURE
NO DAMAGE
+ 0.03 %(0~50℃)
VIBRATION TEST
Ta= 65
TEST:OK
P
℃
HUMIDITY=
95 %R.H
I/P: 230 VAC
+ 0.002 %(0~50℃)
P
O/P:FULL LOAD
COEFFICIENT
6
I/P: 272 VAC
O/P:95% LOAD
1 Carton & 1 Set
TEST:OK
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:10min/sweep cycle
P
(4) Acceleration:2G
(5) Test Time:1 hour in each axis (X.Y.Z)
(6) Ta:25℃
Model: LPC-35-1400
Test Report
3 / 5
LPC-35 series
35W Single Output Switching Power Supply
SAFETY TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
WITHSTAND VOLTAGE
I/P-O/P: 3 KVAC/min
I/P-O/P: 3.6 KVAC/min
I/P-O/P:
VERDICT
1.940
mA
P
NO DAMAGE
2
ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-O/P: 500
VDC
I/P-O/P:
10.21
GΩ
Ta:25℃/70%RH
P
NO DAMAGE
3
APPROVAL
TUV: Certificate NO :
N/A
UL: File NO :
E.M.C TEST
NO
1
2
3
4
5
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
I/P: 230/240/220 VAC/50HZ
O/P:100/75/50/25% LOAD
PASS
CLASS A
CLASS C
Ta:25℃
EN55022
I/P: 230 VAC (50HZ)/115V(60HZ)
PASS
CLASS B
O/P:FULL/50% LOAD
Ta:25℃
Test by certified Lab
CONDUCTION
RADIATION
E.S.D
E.F.T
6
SURGE
EN55022
I/P: 230 VAC (50HZ)/115V(60HZ)
PASS
O/P:FULL LOAD
Ta:25℃
Test by certified Lab
EN61000-4-2
I/P: 230 VAC/50HZ
CRITERIA A
LIGHT INDUSTRY
AIR:8KV / Contact:4KV
O/P:FULL LOAD
Ta:25℃
EN61000-4-4
I/P: 230 VAC/50HZ
LIGHT INDUSTRY
O/P:FULL LOAD
Ta:25℃
IEC61000-4-5
I/P: 230 VAC/50HZ
LIGHT INDUSTRY
O/P:FULL LOAD
Ta:25℃
L-N :1KV
7
P
CLASS B
INPUT: 1KV
VERDICT
P
P
P
CRITERIA A
P
CRITERIA A
P
Test by certified Lab & Test Report Prepare
M.T.B.F & LIFE CYCLE CALCULATION
NO
1
TEST ITEM
SPECIFICATION
CAPACITOR
LPC-35-1400:SUPPOSE C105
IS THE MOST CRITICAL COMPONENT
I/P: 230VAC O/P:FULL LOAD Ta=25 ℃ LIFE TIME= 212352 HRS
LIFE CYCLE
I/P: 230VAC
2
3
TEST CONDITION
O/P:FULL LOAD Ta=65 ℃
LIFE TIME=
MTBF
MIL-HDBK-217F NOTICES2 PARTS COUNT
DMTBF/Accelerated Life Test
TOTAL FAILURE RATE: 743.5 K HRS
Demonstration Mean Time Between Failure(Expected Life) :
20,000 hours @ Tcase 80℃; 50,000 hours @ Tcase 65℃
27888
RESULT
VERDICT
P
HRS
P
P
Model: LPC-35-1400
Test Report
4 / 5
LPC-35 series
35W Single Output Switching Power Supply
COMPONENT STRESS TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
Power Transistor
Q1 Rated
I/P:High-Line +3V = 267 V
(1)
586
V
VERDICT
( D to S) or (C to E) Peak Voltage
STF6NM60N :600 V/ 4.6A
O/P: (1)Full Load Turn on
(2)
456
V
I/P:High-Line +3V = 267 V
(1)
190
V
O/P: (1)Full Load Turn on
(2)
180
V
(1)
496
V
P
(2) Output Short
Ta:25℃
2
Diode Peak Voltage
D100Rated
FMX-12SL 10A/200V
P
(2)Output Short
Ta:25℃
3
Clamp Diode Peak Voltage
D1 Rated
EGP20J:2A/600V
I/P:High-Line +3V = 267 V
O/P: (1) Dynamic Load
90%Duty/1KHz
P
Ta:25℃
4
Input Capacitor Voltage
C5 Rated
120u/400V 105℃ KMG
I/P:High-Line +3V = 267 V
(1)
370
V
O/P: (1)Full Load Turn on /Off
(2)
378
V
(2) Min load Turn on /Off
(3)
378
V
(3)Full Load /Min load Change
Ta:25℃
5
Control IC Voltage Test
P
U1
I/P:High-Line +3V = 267 V
(1)
11.36
V
NCP1200/ 18V
O/P: (1)Full Load Turn on /Off
(2)
10.24
V
(2) Min load Turn on /Off
(3)
11.36
V
P
(3)Full Load /Min load Change
Ta:25℃
DATE
2008/5/5
2008/9/4
2008/11/10
SAMPLE
TEST RESULT
TESTER
APPROVAL
RD SAMPLE
PASS
SANFORD SU
VINCENT TSENG
PASS
SANFORD SU
VINCENT TSENG
PASS
SANFORD SU
VINCENT TSENG
PRODUCT SAMPLE
W0806C09
PRODUCT SAMPLE
W0809E05
2003/12/12
Model: LPC-35-1400
A50-F023
Test Report
5 / 5