RPT-75 series 75W Triple Output Medical Type MODEL:RPT-7503 OUTPUT FUNCTION TEST NO 1 2 3 4 5 TEST ITEM SPECICATION TEST CONDITION RIPPLE & NOISE V1: 80 mVp-p (Max ) I/P: 230VAC RESULT V1: 10 mVp-p (Max ) VERDICT V2: 120 mVp-p (Max ) 29 mVp-p (Max ) mVp-p (Max ) O/P:FULL LOAD Ta:25℃ V2: V3: 120 V3: 35 mVp-p (Max ) OUTPUT VOLTAGE V1: 4 %~ -4 % (Max) I/P: 100 VAC / 264 VAC V1: 2.5 %~ % TOLERANCE V2: 6 %~ -6 % (Max) V2: 3 %~ % V3: 10 %~ -6 % (Max) O/P:FULL/ MIN Ta:25℃ V3: 5.5 %~ % V1: 1 %~ -1 % (Max) I/P: 100 VAC ~ 264 VAC V1: 0.36 %~ % V2: 1 %~ -1 % (Max) V2: 0.36 %~ % V3: 1.5 %~ -1.5 % (Max) O/P:FULL LOAD Ta:25℃ V3: 1 %~ % V1: 3 %~ -4 % (Max) I/P: 230 VAC V1: 1.7 %~ % V2: 5 %~ -4 % (Max) V2: 2.7 %~ % V3: 6 %~ -6 % (Max) O/P:FULL ~MIN LOAD Ta:25℃ V3: 2 %~ % V1: 3 %~ -4 % (Max) I/P: 230 VAC V1: 1.6 %~ % V2: 5 %~ -4 % (Max) O/P: Testing O/P 60%LOAD V2: 2.9 %~ % V3: 4.3 %~ % LINE REGULATION LOAD REGULATION CROSS REGULATION V3: 6 %~ -6 % (Max) LOAD Other O/P 40%LOAD P P P P P Change Ta:25℃ 6 SET UP TIME 230VAC: 500 ms (Max) I/P: 230 VAC 230VAC/ 146 ms 115 VAC: 500 ms (Max) I/P: 115 VAC 115VAC/ 130 ms O/P:FULL LOAD Ta:25℃ 7 RISE TIME 230VAC: 30 ms (Max) I/P: 230 VAC 230VAC/ 4 ms 115VAC: 30 ms (Max) I/P: 115 VAC 115VAC/ 4 ms O/P:FULL LOAD Ta:25℃ 8 HOLD UP TIME 230VAC: 90 ms (TYP) I/P: 230 VAC 230VAC/ 115 ms 115VAC: 20 ms (TYP) I/P: 115 VAC 115VAC/ 23.4 ms <5 % O/P:FULL LOAD Ta:25℃ 9 OVER/UNDERSHOOT TEST I/P: 230 VAC < +5% TEST: O/P:FULL LOAD Ta:25℃ 10 DYNAMIC LOAD V1: 660 mVp-p I/P: 230 VAC P P P P 246 mVp-p O/P:FULL /Min LOAD P 90%DUTY/1KHZ Ta:25℃ Model: RPT-7503 Test Report 1 / 5 RPT-75 series 75W Triple Output Medical Type INPUT FUNCTION TEST NO 1 TEST ITEM SPECICATION TEST CONDITION RESULT INPUT VOLTAGE RANGE 90VAC~264 VAC I/P:TESTING 52V~264V VERDICT O/P:FULL LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V= 87V P HIGH-LINE+15%=300 V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 3 INPUT FREQUENCY RANGE 47HZ ~63 HZ I/P: 90VAC ~ 264 VAC NO DAMAGE OSC O/P:FULL~MIN LOAD Ta:25℃ 74% (TYP) EFFICIENCY I/P: 230 VAC TEST: OK P 73.6% O/P:FULL LOAD Ta:25℃ 4 INPUT CURRENT P 230V/ 1 A (TYP) I/P: 230 VAC I= 0.75 A/ 230 VAC 115V/ 1.5 A (TYP) I/P: 115 VAC I= 1.25 A/ 115 VAC P O/P:FULL LOAD Ta:25℃ 5 INRUSH CURRENT 230V/ 50 A (TYP) I/P: 230 VAC I= 37 A/ 230 VAC 115V/ 25 A(TYP) I/P: 115 VAC I= 18 A/ 115 VAC COLD START 6 LEAKAGE CURRENT < < 150 100 P O/P:FULL LOAD Ta:25℃ uA/ 264 VAC I/P: 264 VAC L-FG: 119 uA for N-FG: 119 uA leakage current O/P:Min LOAD Ta:25℃ uA/264 VAC I/P: 264 VAC L-V+ : 84 uA for O/P:Min LOAD Ta:25℃ L-V-: 84 uA N-V+: 84 uA N-V-: 84 uA earth touch leakage current P P PROTECTION FUNCTION TEST NO 1 2 3 TEST ITEM SPECICATION TEST CONDITION RESULT OVER LOAD PROTECTION 140 %~ 180 % I/P: 230 VAC 158 %/ 230 VAC I/P: 115 VAC 155 %/ 115 VAC O/P:TESTING Ta:25℃ Hiccup Mode OVER VOLTAGE PROTECTION SHORT PROTECTION CH1: 3.8V~ 4.45V I/P: 230 VAC 4.3 V/ 230 VAC I/P: 115 VAC 4.3 V/ 115 VAC O/P:MIN LOAD Ta:25℃ Shunt down Re- power ON SHORT EVERY OUTPUT I/P: 264 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P:FULL LOAD Ta:25℃ Hiccup Mode Model: RPT-7503 VERDICT P P P Test Report 2 / 5 RPT-75 series 75W Triple Output Medical Type ENVIRONMENT TEST NO 1 TEST ITEM SPECICATION TEMPERATURE RISE TEST MODEL: RPT-75A WITH FAN TEST CONDITION RESULT VERDICT 1. ROOM AMBIENT BURN-IN:1HRS I/P: 230VAC O/P: FULL LOAD Ta=31.3℃ 2. HIGH AMBIENT BURN-IN:1.5HRS I/P: 230VAC O/P: FULL LOAD Ta=52.5℃ Position P/N 1 2 BD1 LF2 US4K80 4A/800V SHI TR-719 52.8℃ 70.7℃ 3 C6 100U/400V NCC 105℃ 38.6℃ 59.9℃ 4 C36 47U/50V RUB 105℃ YXF 42.8℃ 64.0℃ 5 T1COIL TF-1524 JSI 66.6℃ 89.9℃ 6 D1 HER308 3A/1KV REC 55.7℃ 78.6℃ 7 ZD1 P6KE250A LT 39.4℃ 63.9℃ 8 Q1 STP9NK70ZFP 7.5A/700V 55.2℃ 78.8℃ 83.0℃ 9 D100 STPS2045CT 20A/45V ST 58.5℃ 10 D200 SF10SC6 10A/60V SHI 66.6℃ 90.4℃ 11 RG1 AN7905T 69.5℃ 93.0℃ 12 D300 SR360 3A/60V 61.9℃ 82.7℃ 13 C105 22000U/16V RUB 105℃ 41.1℃ 64.4℃ 14 C205 1000U/16V RUB 105℃ ZLH 52.6℃ 75.6℃ 15 C305 470U/25V NCC 105℃ KY 56.6℃ 78.4℃ 16 R3 68KΩ/2W R/MO 57.4℃ 78.4℃ NCP1230D165R2 ON 39.2℃ 60.4℃ 17 2 OVER LOAD BURN-IN TEST ROOM AMBIENT HIGH AMBIENT Ta=31.3 ℃ Ta=52.5 ℃ 50.6℃ 70.3℃ NO U1 NO DAMAGE I/P: 230 VAC O/P:V1=10A V2=5A V3=1A 1 HOUR ( MIN ) P TEST:OK P Ta:25℃ 3 LOW TEMPERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/P: 230 VAC O/P: 100﹪LOAD TEST:OK P Ta= -20℃ 4 AFTER 12 HOURS I/P: 272 VAC HIGH TEMPERATURE IN CHAMBER ON CONTROL 50 ℃ O/P:FULL LOAD Ta= 50 ℃ NO DAMAGE + 0.03 %(0~50℃) I/P: 230 VAC HIGH VOLTAGE TURN ON TEST 5 TEMPERATURE VIBRATION TEST HUMIDITY= P 95 %R.H + 0.019 %(0~50℃) P O/P:FULL LOAD COEFFICIENT 6 TEST:OK HIGH HUMIDITY 1 Carton & 1 Set TEST:OK (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle P (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) Ta:25℃ Model: RPT-7503 Test Report 3 / 5 RPT-75 series 75W Triple Output Medical Type SAFETY TEST NO 1 2 3 TEST ITEM SPECICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 4 KVAC/min I/P-O/P: 4.2 KVAC/min I/P-O/P: 2.14 mA I/P-FG: 1.5 KVAC/min I/P-FG: 1.8 KVAC/min I/P-FG: 1.36 mA O/P-FG: 1.5 KVAC/min O/P-FG: 1.8 KVAC/min Ta:25℃ O/P-FG: 1.57 mA I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: 9 GΩ I/P-FG: 500VDC>100MΩ I/P-FG: 500 VDC O/P-FG:500VDC>100MΩ O/P-FG: 500 Ta:25℃ VDC I/P-FG: 9 GΩ O/P-FG: 18 GΩ ISOLATION RESISTANCE APPROVAL VERDICT P NO DAMAGE P NO DAMAGE TUV: Certificate NO : TA 50096088 P UL: File NO :E227340 E.M.C TEST NO 1 2 3 4 TEST ITEM SPECICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P: 230 VAC/50HZ PASS CLASS A O/P:FULL LOAD Ta:25℃ EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL/50% LOAD Ta:25℃ Test by certified Lab CONDUCTION RADIATION E.S.D 5 E.F.T EN55022 I/P: 230 VAC (50HZ) PASS O/P:FULL LOAD Ta:25℃ Test by certified Lab EN61000-4-2 MEDICAL I/P: 230 VAC/50HZ CRITERIA A EN61000-4-4 MEDICAL SURGE P P O/P:FULL LOAD Ta:25℃ I/P: 230 VAC/50HZ P CRITERIA A O/P:FULL LOAD Ta:25℃ INPUT: 2KV 6 P CLASS B AIR:8KV / Contact:6KV VERDICT IEC61000-4-5 MEDICAL I/P: 230 VAC/50HZ P CRITERIA A O/P:FULL LOAD Ta:25℃ L-N :1KV P L,N-PE:2KV 7 Test by certified Lab & Test Report Prepare M.T.B.F & LIFE CYCLE CALCULATION NO 1 TEST ITEM SPECICATION CAPACITOR RPT-75A WITH FAN : SUPPOSE C105 IS THE MOST CRITICAL COMPONENT I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 1419902 HRS LIFE CYCLE I/P: 230VAC 2 MTBF TEST CONDITION O/P:FULL LOAD Ta= 50 ℃ RESULT VERDICT P LIFE TIME= 217049 HRS MIL-HDBK-217F NOTICES2 PARTS COUNT P TOTAL FAILURE RATE: 521.2K HRS Model: RPT-7503 Test Report 4 / 5 RPT-75 series 75W Triple Output Medical Type COMPONENT STRESS TEST NO 1 TEST ITEM SPECICATION TEST CONDITION RESULT Power Transistor Q1 Rated I/P:High-Line +3V = 267 V (1) 646 V VERDICT ( D to S) or (C to E) Peak Voltage STP9NK70ZFP : 700V 7.5A O/P: (1)Full Load Turn on (2) 648 V P (2) Output Short Ta:25℃ 2 Diode Peak Voltage D100 Rated I/P:High-Line +3V = 267 V (1) 26 V STPS3045CT : 45V 30A O/P: (1)Full Load Turn on (2) 25 V D200 Rated (1) 37 V STP2045CT : 45V 20 A (2) 37 V D300 Rated (1) 108 V HER306 : 600V 3A (2) 111 V (1) 596 V (2)Output Short Ta:25℃ 3 Clamp Diode Peak Voltage D1 Rated I/P:High-Line +3V = 267 V HER308 : 1000V 3A O/P: (1) Dynamic Load P 90%Duty/1KHz P Ta:25℃ 4 Input Capacitor Voltage C5 Rated : 100u / 400V/ 105℃ I/P:High-Line +3V = 267 V (1) 368 V O/P: (1)Full Load Turn on /Off (2) 372 V (2) Min load Turn on /Off (3) 372 V P (3)Full Load /Min load Change Ta:25℃ 5 Control IC Voltage Test U1 Rated I/P:High-Line +3V = 267 V (1) 12.66 V 1230D165R2G : 18V O/P: (1)Full Load Turn on /Off (2) 10.75 V (2) Min load Turn on /Off (3) 12.66 V P (3)Full Load /Min load Change Ta:25℃ DATE 2006/9/5 2006/11/14 2007/5/9 SAMPLE TEST RESULT TESTER APPROVAL RD SAMPLE PASS VINCENT TSENG MAX LIN PASS VINCENT TSENG MAX LIN PASS VINCENT TSENG MAX LIN PRODUCT SAMPLE W0610A20 PRODUCT SAMPLE W073A31 2003/12/12 A50-F023 Model: RPT-7503 Test Report 5 / 5