200W Medical series

200W Medical series
1~4 Output Medical Type
MODEL: MPT-200B
OUTPUT FUNCTION TEST
NO
1
2
TEST ITEM
SPECICATION
TEST CONDITION
RIPPLE & NOISE
V1: 80
mVp-p (Max )
I/P: 230VAC
V1:
26
mVp-p (Max )
V2: 120
mVp-p (Max )
48
mVp-p (Max )
mVp-p (Max )
O/P:FULL LOAD
Ta:25℃
V2:
V3: 80
V3:
28
mVp-p (Max )
OUTPUT VOLTAGE
CH1: 4.75 V~ 5.5 V
ADJUST RANGE
RESULT
VERDICT
I/P: 230 VAC
4.51
V~
5.62
V/ 230 VAC
I/P: 115 VAC
4.51
V~
5.62
V/ 115 VAC
P
O/P:MIN LOAD
Ta:25℃
3
4
5
6
OUTPUT VOLTAGE
V1: 2 %~ -2 % (Max)
I/P: 115 VAC / 264 VAC
V1:
0.4
%~
-0.4
%
TOLERANCE
V2: 8 %~ -8 % (Max)
V2:
4
%~
-4
%
V3: 5 %~ -5 % (Max)
O/P:FULL/ MIN
Ta:25℃
V3:
0.3
%~
-0.3
%
V1: 0.5 %~ -0.5 % (Max)
I/P: 115 VAC ~ 264 VAC
V1:
0
%~
0
%
V2: 1 %~ -1 % (Max)
V2:
0.05
%~
-0.05
%
V3: 0.5 %~ -0.5 % (Max)
O/P:FULL LOAD
Ta:25℃
V3:
0.1
%~
-0.1
%
V1: 1 %~ -1 % (Max)
I/P: 230 VAC
V1:
0.24
%~
-0.24
%
V2: 5 %~ -5 % (Max)
V2:
1.4
%~
-1.4
%
V3: 1 %~ -1 % (Max)
O/P:FULL ~MIN LOAD
Ta:25℃
V3:
0.3
%~
-0.3
%
V1: 1 %~ -1 % (Max)
I/P: 230 VAC
V1:
0.12
%~
-0.12
%
V2: 5 %~ -5 % (Max)
O/P: Testing O/P 60%LOAD
V2:
2.7
%~
-2.7
%
V3:
0.05
%~
-0.05
%
LINE REGULATION
LOAD REGULATION
CROSS REGULATION
V3: 1 %~ -1 % (Max)
LOAD
Other O/P 40%LOAD
P
P
P
P
P
Change
Ta:25℃
7
SET UP TIME
230VAC:
1000
ms (Max)
I/P: 230 VAC
230VAC/
664
ms
115 VAC:
3000
ms (Max)
I/P: 115 VAC
115VAC/
1929
ms
O/P:FULL LOAD
Ta:25℃
8
RISE TIME
230VAC:
20
ms (Max)
I/P: 230 VAC
230VAC/
16
ms
115VAC:
20
ms (Max)
I/P: 115 VAC
115VAC/
14
ms
O/P:FULL LOAD
Ta:25℃
9
HOLD UP TIME
230VAC:
16
ms(TYP)
I/P: 230 VAC
230VAC/
18
ms
115VAC:
16
ms (TYP)
I/P: 115 VAC
115VAC/
18
ms
TEST:
<5
%
O/P:FULL LOAD
Ta:25℃
10
OVER/UNDERSHOOT TEST
I/P: 230 VAC
< +5%
O/P:FULL LOAD
Ta:25℃
11
DYNAMIC LOAD
V1:
1000
mVp-p
I/P: 230 VAC
P
P
P
P
328
mVp-p
O/P:FULL /Min LOAD
P
90%DUTY/1KHZ
Ta:25℃
Model: MPT-200B
Test Report
1 / 6
200W Medical series
1~4 Output Medical Type
INPUT FUNCTION TEST
NO
1
TEST ITEM
SPECICATION
TEST CONDITION
RESULT
INPUT VOLTAGE RANGE
90VAC~264 VAC)
I/P:TESTING
73 V~264V
VERDICT
O/P:FULL LOAD
Ta:25℃
I/P:
TEST: OK
LOW-LINE-3V= 87 V
P
HIGH-LINE+15%=300 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
( AC POWER ON/OFF NO DAMAGE )
2
3
INPUT FREQUENCY RANGE
POWER FACTOR
47HZ ~440HZ
I/P: 90 VAC ~ 264 VAC
NO DAMAGE OSC
O/P:FULL~MIN LOAD
Ta:25℃
TEST: OK
0.95/ 230 VAC(TYP)
I/P: 230 VAC
PF= 0.97 /230 VAC.
0.98/1150 VAC(TYP)
I/P: 115 VAC
PF= 0.99 /115 VAC
P
P
O/P:FULL LOAD
Ta:25℃
4
80% (TYP)
EFFICIENCY
I/P: 230 VAC
80.7 %
O/P:FULL LOAD
Ta:25℃
5
INPUT CURRENT
P
230V/
1.6
A (TYP)
I/P: 230 VAC
I=
1.1
A/ 230 VAC
115V/
3.5
A (TYP)
I/P: 115 VAC
I=
2.3
A/ 115 VAC
O/P:FULL LOAD
Ta:25℃
6
INRUSH CURRENT
230V/
40
A(TYP)
I/P: 230 VAC
I=
26
A/ 230 VAC
115V/
25
A (TYP)
I/P: 115 VAC
I=
13
A/ 115 VAC
O/P:FULL LOAD
Ta:25℃
COLD START
7
LEAKAGE CURRENT
a. For earth leakage current
b. For patient leakage current
a.
<180
uA / 264 VAC
I/P: 264 VAC
a.
74
uA
b.
<100
uA / 264 VAC
O/P:Min LOAD
Ta:25℃
b.
38
uA
Model: MPT-200B
P
P
P
Test Report
2 / 6
200W Medical series
1~4 Output Medical Type
PROTECTION FUNCTION TEST
NO
1
2
3
TEST ITEM
OVER LOAD PROTECTION
OVER VOLTAGE PROTECTION
OVER TEMPERATURE ROTECTION
SPECICATION
120 %~ 160 %
CH1: 5.75 V~ 6.75 V
SPEC:
TSW1: 95 + 5℃ O.T.P.
TEST CONDITION
RESULT
VERDICT
I/P: 230 VAC
137 %/ 230 VAC
I/P: 115 VAC
136 %/ 115 VAC
O/P:TESTING
Ta:25℃
Hiccup Mode
P
I/P: 230 VAC
6.1 V/ 230 VAC
I/P: 115 VAC
6.1 V/ 115 VAC
O/P:MIN LOAD
Ta:25℃
Shunt down Re- power ON
I/P: 230 VAC
O.T.P. Active
Shut down o/p voltage,recovers
O/P:FULL LOAD
NO DAMAGE
automatically
after
P
P
temperature
goes down
4
SHORT PROTECTION
SHORT EVERY OUTPUT
I/P: 264 VAC
NO DAMAGE
1 HOUR NO DAMAGE
O/P:FULL LOAD
Ta:25℃
Hiccup Mode
P
CONTROL FUNCTION TEST
NO
1
2
TEST ITEM
SPECICATION
TEST CONDITION
RESULT
REMOTE CONTROL
Rc+ / Rc-
I/P: 230 VAC
0V ~ 2.5 V
0V~ 0.8V POWER ON
O/P:FULL LOAD
Ta:25℃
2.6 V ~ 10 V
4V~ 10V POWER OFF
DELAY 10ms ~ 500ms
I/P: 230 VAC
292 ms/ 230 VAC
I/P: 115 VAC
291 ms/ 115 VAC
POWER GOOD SIGNAL
VERDICT
POWER ON
POWER OFF
P
P
O/P:FULL LOAD
Ta:25℃
3
POWER FAIL SIGNAL
>
1ms
I/P: 230 VAC
6 ms/ 230 VAC
I/P: 115 VAC
5 ms/ 115 VAC
P
O/P:FULL LOAD
Ta:25℃
4
REMOTE SENSE
>0.25V
I/P: 230 VAC
>0.25V
O/P:FULL LOAD
Ta:25℃
P
Model: MPT-200B
Test Report
3 / 6
200W Medical series
1~4 Output Medical Type
ENVIRONMENT TEST
NO
1
TEST ITEM
SPECICATION
TEMPERATURE RISE TEST
MODEL:MPQ-200B WITH FAN
TEST CONDITION
RESULT
VERDICT
1. ROOM AMBIENT BURN-IN:2HRS
I/P: 230VAC O/P: FULL LOAD Ta= 28.8 ℃
2. HIGH AMBIENT BURN-IN:2HRS
I/P: 230VAC O/P: FULL LOAD Ta= 50.7 ℃
NO
2
OVER LOAD BURN-IN TEST
Position
ROOM AMBIENT HIGH AMBIENT
Ta= 28.8℃
Ta= 50.7 ℃
52.5℃
74.5℃
P/N
1
LF2
LF-104
2
D23
31DF6 3A/600V
38.2℃
60.1℃
IRFP450 14A/500V
45.7℃
68.0℃
3
Q20
4
T1 COIL
TF-1171
45.3℃
66.3℃
5
D100
SBL3040PT 30A/40V LT
80.3℃
100.6℃
6
D200
S20LC20U 20A/200V SHI
57.9℃
79.1℃
7
D300
F10SC6 10A/60V SHI
57.9℃
78.8℃
8
RG70
R05PI 3A/35V KEC
58.6℃
79.3℃
9
BD1
D3SB60 4A/600V SHI
48.4℃
71.8℃
10
C5
150U/400V RUB 105℃
40.6℃
60.2℃
84.8℃
11
L2
TR-570
66.3℃
12
Q1
IRFP460A 20A/500V
63.6℃
84.4℃
13
U1
ML4800CP
45.2℃
66.7℃
14
L100
TR-523
69.3℃
91.7℃
15
C110
2200U/6.3V RUB 105℃
47.0℃
69.9℃
NO DAMAGE
I/P: 230 VAC
1 HOUR ( MIN )
O/P: V1@20A
P
TEST:OK
V2@9A
P
[email protected]
[email protected]
Ta:25℃
3
LOW TEMPERATURE
TURN ON AFTER
2 HOUR
TURN ON TEST
I/P: 230 VAC
O/P: 80 ﹪LOAD
TEST:OK
P
Ta= -20 ℃
4
AFTER 12 HOURS
I/P: 272 VAC
HIGH TEMPERATURE
IN CHAMBER ON
CONTROL 50 ℃
O/P:FULL LOAD
Ta= 50 ℃
NO DAMAGE
+ 0.04 %(0~50℃)
I/P: 230 VAC
HIGH VOLTAGE
TURN ON TEST
5
TEMPERATURE
VIBRATION TEST
HUMIDITY=
P
95 %R.H
+ 0.02 %(0~50℃)
P
O/P:FULL LOAD
COEFFICIENT
6
TEST:OK
HIGH HUMIDITY
1 Carton & 1 Set Operating
TEST:OK
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:10min/sweep cycle
P
(4) Acceleration:2G
(5) Test Time:1 hour in each axis (X.Y.Z)
(6) Ta:25℃
Model: MPT-200B
Test Report
4 / 6
200W Medical series
1~4 Output Medical Type
SAFETY TEST
NO
1
2
3
4
TEST ITEM
SPECICATION
TEST CONDITION
RESULT
WITHSTAND VOLTAGE
I/P-O/P: 4 KVAC/min
I/P-O/P: 4.2 KVAC/min
I/P-O/P:
1.98
mA
I/P-FG: 1.5 KVAC/min
I/P-FG: 1.8 KVAC/min
I/P-FG:
1.18
mA
O/P-FG: 1.5 KVAC/min
O/P-FG: 1.8 KVAC/min
Ta:25℃
O/P-FG:
1.57
mA
I/P-O/P:500VDC>100MΩ
I/P-O/P: 500
VDC
I/P-O/P:
22
GΩ
I/P-FG: 500VDC>100MΩ
I/P-FG:
500
VDC
O/P-FG:500VDC>100MΩ
O/P-FG: 500
Ta:25℃
VDC
I/P-FG:
30
GΩ
O/P-FG:
30
GΩ
ISOLATION RESISTANCE
GROUNDING CONTINUITY
FG(PE) TO CHASSIS
APPROVAL
OR TRACE < 100 mΩ
TUV: Certificate NO :TA50069957
VERDICT
P
NO DAMAGE
P
NO DAMAGE
40 A / 2min
Ta:25℃
18
mΩ
P
P
UL: File NO :E227340
E.M.C TEST
NO
1
2
3
4
5
TEST ITEM
SPECICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
I/P: 230 VAC/50HZ
PASS
CLASS A
O/P:FULL LOAD
Ta:25℃
EN55022
I/P: 230 VAC (50HZ)
PASS
CLASS B
O/P:FULL/50% LOAD
Ta:25℃
Test by certified Lab
CONDUCTION
RADIATION
E.S.D
E.F.T
6
SURGE
P
EN55022
I/P: 230 VAC (50HZ)
PASS
CLASS B
O/P:FULL LOAD
Ta:25℃
Test by certified Lab
EN61000-4-2
I/P: 230 VAC/50HZ
CRITERIA A
INDUSTRY
AIR:8KV / Contact:4KV
O/P:FULL LOAD
Ta:25℃
EN61000-4-4
I/P: 230 VAC/50HZ
INDUSTRY
O/P:FULL LOAD
Ta:25℃
INPUT: 2KV
IEC61000-4-5
I/P: 230 VAC/50HZ
INDUSTRY
O/P:FULL LOAD
Ta:25℃
L-N :2KV
VERDICT
P
P
P
CRITERIA A
P
CRITERIA A
P
L,N-PE:4KV
7
Test by certified Lab & Test Report Prepare
M.T.B.F & LIFE CYCLE CALCULATION
NO
1
TEST ITEM
SPECICATION
CAPACITOR
SUPPOSE C110 IS THE MOST CRITICAL COMPONENT
I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 437900 HRS
LIFE CYCLE
I/P: 230VAC
2
MTBF
TEST CONDITION
O/P:FULL LOAD Ta= 50 ℃
RESULT
VERDICT
P
LIFE TIME= 72238 HRS
MIL-HDBK-217F NOTICES2 PARTS COUNT
P
TOTAL FAILURE RATE: 262.1k HRS
Model: MPT-200B
Test Report
5 / 6
200W Medical series
1~4 Output Medical Type
COMPONENT STRESS TEST
NO
1
TEST ITEM
SPECICATION
TEST CONDITION
RESULT
Power Transistor
Q20 Rated
I/P:High-Line +3V = 267 V
(1)
390
V
( D to S) or (C to E) Peak Voltage
IRFP450 : 500 V 14A
O/P: (1)Full Load Turn on
(2)
390
V
(3)
390
V
I/P:High-Line +3V = 267 V
(1)
21.7
V
O/P: (1) Full Load Turn on
(2)
18.8
V
(3)
22
V
(1)
50.6
V
(2)
41
V
(3)
50.6
V
(1)
62.2
V
(2)
53.2
V
(3)
63.4
V
I/P:High-Line +3V = 267 V
(1)
388
V
O/P: (1)Full Load Turn on /Off
(2)
388
V
(2) Min load Turn on /Off
(3)
394
V
(3)Full Load /Min load Change
Ta:25℃
(4)
390
V
(2) Full Load
VERDICT
P
(3)Output Short
Ta:25℃
2
Diode Peak Voltage
D100 Rated
SBL3040PT : 40 V
30 A
(2) Full Load
(3)Output Short
Ta:25℃
D200 Rated
S20LC20U : 200 V
20 A
D300 Rated
FMX-12S :
3
Input Capacitor Voltage
200 V 10 A
C 5 Rated
: 150u / 400V/ 105℃
P
P
(4)Burn in 1hr
4
Control IC Voltage Test
U1 Rated
I/P:High-Line +3V = 267 V
(1)
14.8
V
ML4800 : 18 V
O/P: (1)Full Load Turn on /Off
(2)
14.8
V
(2) Min load Turn on /Off
(3)
15.1
V
P
(3)Full Load /Min load Change
Ta:25℃
5
Power Transistor
Q1 Rated
I/P:High-Line +3V = 267 V
(1)
390
V
( D to S) or (C to E) Peak Voltage
IRFP460A : 500 V 20A
O/P: (1)Full Load Turn on
(2)
408
V
(3)
388
V
(2) Full Load
P
(3)Output Short
Ta:25℃
DATE
SAMPLE
TEST RESULT
TESTER
APPROVAL
2005/5/17
RD SAMPLE
PASS
VINCENT TSENG
MAX LIN
PASS
VINCENT TSENG
MAX LIN
PASS
VINCENT TSENG
MAX LIN
2005/9/3
2006/4/11
PRODUCT SAMPLE
W0507B20
PRODUCT SAMPLE
W0603C35
2003/12/12
Model: MPT-200B
A50-F023
Test Report
6 / 6